1. For Climat 50 min 1 5 square feet For Climat 130 min 6 5 square feet WARNING FAILURE TO PROVIDE PROPER FRESH AIR VENTILATION CAN RESULT TO SERIOUS MALFUNCTION OF THE BURNER AND LACK OF OXYGEN IN THE WORKING AREA PROVIDE VENTILATION BEFORE RUNNING HEATER AND DURING THE WHOLE HEATING PERIOD DUCTING CAUTION USE ONLY DUCT MADE OF METAL OR MINERAL MATERIALS NOT SUBJECT TO DETERIORATION FROM MILDEW OR MOISTURE MATERIAL SHALL COMPLY WITH THE REQUIREMENTS OF UL STANDARD UL 214 Use steel or canvas ducting capable to withstand max temperatures of 250 F Max length of duct 25 feet min diameter 12 inches Avoid sharp bends and corners to allow maximum air flow Using insulated duct helps to minimize heat losses in duct Patron Climat 4 08 OPERATION REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL THEY ARE ESSENTIAL FOR SAFE USE OF THE HEATER FOLLOW ALL LOCAL CODES WARNING DO NOT START HEATER IF EXCESS OIL HAS ACCUMULATED IN THE COMBUSTION CHAMBER DO NOT FILL OIL TANK OR SWITCH DRUMS WHILE HEATER IS RUNNING DO NOT SHUT OFF HEATER BY DISCONNECTING POWER SUPPLY CORD READ SEPARATE BURNER MANUAL FOR BURNER INSTRUCTIONS TO START HEATING 1 Make sure you have read understood and followed all installation ventilation and safety instructions in this manual 2 Place the heater on a stable and level surface Make sure that no explosive or com bustible fumes or dust are present Protect heater fr
2. IF IN TROUBLE CALL A COMPETENT OIL BURNER SERVICEMAN Patron Climat 4 08 9 PART LIST OF PATRON CLIMAT 40A amp 50A Item Part no Description Item Part no Part no Description Climat Climat 40A 50A 1 bottom plate 24 14024 15024 front handle 2 side plate left amp right 25 14025 15025 bracket fan motor 3 shield right 26 14026 15026 fan guard 4 shield left 27 14027 15027 fan blade 5 shield bottom rear 28 14028 15028 fan motor 6 shield bottom middle 14029 14029 bracket control box 7 shield bottom front 14030 14030 control box empty 8 front panel YSM 14031 14031 main switch 9 air outlet adapter 51 14032 14032 bypass switch 0 fan panel TB 14033TB 14033TB thermostat burner amp TO 14033TO 14033TO overheat cover plate TF 14034 14034 thermostat fan control shield top H1 14035 14035 indicator light flue collar TRS 14036 14036 room thermostat socket hoist eye TR 14037 14037 remote room thermo stat with cable amp plug wheel 2 ea 14038 15038 power cord amp plug locking washer 2 ea 14039 15039 burner cover 14040 14040 glass eye gasket flame detection wheel shaft 20 mm 14041 14041 oil wand support leg 14042 14042 oil hose 2 ea burner chamber assem 14043 14043 oil wand holder bly baffle heat exchanger 14044 14044 motor box 2 ea lid h
3. THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PROD UCTS INC FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNEC TION WITH THE USE OR PERFORMANCE OF THE PRODUCT OR OTHER INDIRECT DAMAGES WITH RESPECT TO LOSS OF PROPERTY REVENUES OR PROFIT OR COST OF REMOVAL INSTALLATION OR REINSTALLATION THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER OF EQUIPMENT SOLD BY THE MANUFACTURER AND ITS DEALERS AND DIS TRIBUTORS AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED During the warranty period Patron Products Inc will at its sole option repair or replace any defective parts or products returned freight prepaid to Patron Products Inc or such other location as Patron Products Inc may designate Returned products must be packaged carefully and Patron Products Inc shall not be re sponsible for damage in transit When returning parts the owner must provide the model number of the product and the nature of difficulty being experienced This warranty does not oblige Patron Products Inc to bear the cost of labour in replacing any assembly unit or component or part thereof nor does the company assume any liability for secondary charges expenses of removal or installing freight or damages There will be charges ren dered for product repair after our warranty period has expired Proof of purchase including date must accompany request for in warranty service All specifications in this manual are su
4. THIS WILL CAUSE THE WHOLE HEATER TO 1 THERMOSTAT SHUT DOWN INCLUDING THE FAN IN CASE OF OVER SOCKET HEATING IN MODELS 40A amp 50A THE HEATER WILL RE QUIRE A PERIOD OF APPROX 20 MIN TO COOL DOWN ENOUGH FOR A RE START MODEL 130A WILL IN CASE OF OVERHEATING TO COOL DOWN THE HEATER AUTOMATICALLY CHECK AND REMOVE CAUSE FOR OVERHEATING BEFORE RE STARTING Patron Climat 4 08 TROUBLESHOOTING gt NOTHING HAPPENS WHEN MAIN SWITCH IS TURNED TO HEAT OR VENT e Check power supply cord and fuses e Push the burner reset button red button on burner relay control box e Push the reset button on fan motor gt FAN STARTS WHEN MAIN SWITCH IS TURNED TO VENT BUT NOTHING HAPPENS IN POSITION HEAT e Check remote thermostat setting e Check remote thermostat cord e Push the burner reset button WITH MAIN SWITCH IN POSITION HEAT BURNER FIRES BUT STOPS AFTER A WHILE WITHOUT FAN MOTOR STARTING e Push the reset button on fan motor OIL BURNER STARTS BUT THERE IS NO FLAME e Check oil level in drum tank e Check for possible water in oil e Check for leaks in oil hoses or couplings e Check that the burner igniter tips give spark when turned on e Clean the photocell sensor of burner CAUTION FOLLOW INSTRUCTIONS IN BURNER MANUAL WHEN CHECKING BURNER Refer to burner manual for additional troubleshooting instructions WARNING DO NOT TAMPER WITH BURNER ADJUSTMENT OR SAFETY EQUIPMENT
5. ADE WITH A SMOKE SAMPLER TESTER TO ENSURE PROPER ATMOSPHERIC AND DRAFT PERFORMANCE OF THE HEATER Patron Climat 4 08 1 HEAT EXCHANGER CLEAN WARM 4 den 5 AIR COOL OUT AIR OIL BURNER OUTER HOUSING BURNER FLAME CHAMBER SEQUENCE OF OPERATION After the main switch has been turned to position HEAT and if the ambient thermostat is set to a temperature higher than ambient the heater will operate automatically as fol lows 1 The burner starts After a short pre purge period the flame will ignite and start heating the combustion chamber 2 When sufficient amount of heat has accumulated in the W esos heater the fan will start by automatic thermostat control and oe clean warm air will be blown out If the incoming air is cool SWITCH enough the burner will stay on continuously but with higher ambient temperatures the burner will shut off occasionally to allow the fan to cool the heater avoiding overheating 3 When the ambient temperature set by the ambient thermo stat has been reached the burner will stop and the fan will run to cool down the heater aw 4 After the room has cooled down below the set temperature the cycle begins again from 1 b 5 The heater is shut off by setting the main switch to position ROOM Note that the fan will run until the heater has cooled down to avoid damage to burner THE HEATER IS PROTECTED BY AN OVERHEAT LIMIT SWITCH
6. L OR DIESEL FUEL ONLY DO NOT USE GASOLINE ALL OIL CONNECTION MUST BE CHECKED FOR LEAKS AFTER INSTALLATION OR SERVICING ALL LEAKS MUST BE CORRECTED AT ONCE THE OIL CONTAINER MUST BE LOCATED AT A MINIMUM DISTANCE OF 6 FEET AWAY FROM THE HEATER 1 Provide oil supply The oil wand supplied is intended for 55 gallon drum but other con tainers may also be used Always use drums in an upright position Never place oil container so that oil level is above burner pump Keep drums out of rain See applica ble standards for Storage and Handling of Fuels 2 Make sure there is no water or other impurities in the fuel 3 Open the drum plug and insert the oil wand in drum Make sure the oil hoses are pro tected from traffic or other sources of damage FLUE PIPE e WHEN USING THE HEATER INDOORS ALWAYS INSTALL A FLUE TO EXHAUST GASES OUT A MINIMUM TWO FEET VERTICAL SECTION IS REQUIRED AS TERMINATION OF FLUE A RAIN CAP IS RECOMMENDED e WHEN USED OUTDOORS WITH HEAT DUCTED IN THE USE OF A MIN 2 FEET FLUE WITH A RAIN CAP IS HIGHLY RECOMMENDED ISOLATE THE FLUE WELL FROM ALL COMBUSTIBLE MATERIALS FLUE DIMENSIONS RAIN CAP RAIN CAP 2FT MIN RISE MIN 1 INCH PER FOOT THE MANUFAC HEATER TURER RECOM MENDS A MINI MUM CHIMNEY Patron Climat 4 08 3 VENTILATION If the heater is located indoors provide a fresh air opening for the burner combustion air of the following sizes For Climat 40 min 1 0 square feet
7. NCE Carbon monoxide poisoning starts with symptoms similar to a common flu with ache nausea or dizziness If you notice these signs get fresh air at once This may be caused by non sufficient ventilation to provide combustion air for the burner or the heater may not operate properly Have heater serviced immediately and provide proper ventilation Make sure you read and understand all warnings This heater is intended to be used for temporary heating of buildings tents etc The heater can be placed outdoors and the heat ducted in or the heater may be placed indoors and the exhaust fumes ducted out Never use heater indoors without exhaust ducting Do not use heater where gasoline paint thinner or other highly flammable vapors or combustible dust are present Check heater for damages before each use Never use damaged heater Do not block air inlet or outlet of heater Keep children and animals away from heater Use only in well vented areas Note this heater is thermostat controlled When plugged heater may start any time Never move handle or service an operating plugged in or hot heater In handling storing or using fuel follow all instructions given in this manual and all lo cal and other applicable safety codes Only plug heater to a three hole electric outlet Unplug heater when not in use Patron Climat 4 08 2 INSTALLATION OF FUEL SUPPLY WARNING USE NO 1 FUEL OI
8. PATRON CLIMAT OIL FIRED CONSTRUCTION HEATERS MODELS 40 50 AND 130 OWNER S MANUAL HEATER SIZES 135 000 and 195 000 and 570 000 BTU Hr CERTIFIED GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PRO VIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY IN JURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EX PLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRI CAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE DISTRIBUTOR WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIR BORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THIN NER DUST PARTICLES OR UNKNOWN CHEMICALS PATRON PRODUCTS INC USA 60 Clyde Avenue Suite 4 Buffalo NY 14215 Canada 12 110 Ironside Crescent Scarborough Ontario M1X 1M2 SAFETY INFORMATION IMPORTANT Read this manual completely and carefully before assembling operating or servicing this heater Improper use can cause serious injury or death from fire explosion electrical shock or carbon monoxide poisoning KEEP THIS MANUAL FOR FURTHER REFERE
9. TION DIAGRAMS Patron Climat 4 08 1 LADDER WIRING DIAGRAM 40A amp 50A c FO lt a 1 0 1 SM 0 2 0 7 off 1 heat 2 7 fan only 5 2 Es 26 c L o z S 2 d gt a o Burner N 120 V 60 Hz E 5 2 o 2 gt N Overheat indicator light Fan motor room thermostat bypass switch lever type main switch 0 off 1 heat 2 fan only lever type Patron Climat 4 08 12 CONNECTION DIAGRAM 40A amp 50A MAIN CONTROL BOX Cable to burner i black L2 5 I thermostat control continuous heat white i S 0 1 S o i green G Power cord 120 V 60 Hz FAN MOTOR BOX only in 40A amp 50A Cable to fan motor Cable from main control box WARNING RISK OF ELECTRIC SHOCK DO NOT TAMPER WITH ELECTRIC WIRING HAVE A QUALIFIED ELECTRICIAN MAKE AND TEST ALL ELECTRIC WIRINGS BEFORE USING OR STARTING HEATER Patron Climat 4 08 13 LADDER WIRING DIAGRAM 130A 0 off 1 heat 2 fan only Patron Climat 4 08 i TR i 1 i TRS TO TB TF H1 S1 0 1 C N LA e __ 28 8 5 e gt s sS E oz a 5 B 120 V 60 Hz Power supply 1 ph 120 V 60 Hz LEGEND Overheat indicator light Fan motor room thermostat bypass switch lever type e UE m s ISM main switch 0
10. bject to change We are not responsible for errors or omissions in this manual PATRON PRODUCTS USA INC PATRON PRODUCTS INC USA 60 Clyde Avenue Suite 4 Buffalo NY 14215 Canada 12 110 Ironside Crescent Scarborough Ontario M1X 1M2 Patron Climat 4 08 16
11. eat exchanger 2 ea gasket heat exchanger 2 ea LETTERS REFER TO ELECTRIC CONNECTION DIAGRAMS Patron Climat 4 08 10 PART LIST OF PATRON CLIMAT 130A Description Description Climat 130A 1 16001 cover plate wheel shaft 20 mm 2 16002 shield top 3 16003 side plate right locking pin washer 2 ea 4 16004 shield right wheel 2 ea 5 16005 front panel shield rear 16006 latch 2 ea outlet adapter fan panel 7 16007 air outlet adapter 8 16008 front handle fan guard 16009 burner cover incl knob latch rear handle fan motor 14030 control box empty fan blade 14029 bracket control box 14031 main switch bracket fan motor 14032 bypass switch side plate left 14033TB thermostat burner shield left 14034 thermostat fan control shield bottom rear 14033TO thermostat overheat burner chamber assembly 14035 indicator light gasket flue pipe 14036 room thermostat socket flue pipe 14037 remote room thermostat with lid heat exchanger cable amp plug 22950 contactor gasket heat exchanger 16018 power cord amp plug baffle heat exchanger 15 ea 16019 shield front flue collar 16020 flame cap hoist eye 16021 support leg oil wand 16022 shield bottom front oil hose L 4 m 2 ea 16023 shield bottom middle oil wand holder 16024 bottom plate LETTERS REFER TO ELECTRIC CONNEC
12. hildren and unqualified per 5 ons MAINTENANCE WARNING NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN CONNECTED TO OIL SUPPLY RUNNING OR HOT SEVERE BODILY INJURE OR ELECTRIC SHOCK MAY OCCUR ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERVICE AND PROVIDE OIL BURNER MAINTENANCE AND REPAIRS Keep heater clean Use pressurized air to blow fan blades clean Note Use moderate pressure to avoid damage to fan blades Inspect heater before and after each use The fan motor is sealed and has permanently lubricated bearings No additional lubri cation is needed Check hose wand assembly before each use Replace worn or damaged hose immedi ately Replace with original PATRON CLIMAT hose assembly only Have the oil burner inspected yearly by a qualified service person Always use original spare parts obtained from your local PATRON dealer CLEANING THE COMBUSTION CHAMBER amp HEAT EXCHANGER Remove the warm air outlet and the end covers of the heat exchanger boxes Pull out baffle plates Clean boxes and plates with a stiff brush 2 Remove the oil burner Clean the combustion chamber through the burner opening with a stiff brush Use vacuum cleaner to remove soot 3 Replace baffles exchanger end covers and air outlet 4 Replace burner HAVE THE BURNER CHECKED REGULARLY TO AVOID SMOKE AND SOOT BUILD UP IN EXCHANGER AREAS NOTE IT IS RECOMMENDED THAT AT THE FINAL JOBSITE LOCATION A BURNER COMBUSTION CHECK BE M
13. off 1 heat 2 me LN To mmo TRS fan only lever type thermostat burner control thermostat fan control thermostat overheating control remote thermostat with plug amp cable room ambient room thermostat socket female M1 CONNECTION DIAGRAM 130A MAIN CONTROL BOX Cable to burner 2 i i i i E 0 off 1 heat i 2 fan only Tu 0 1 1 1 5 BE He B i EH Els S S SIE 10909 1 igs oh Se i i 8 i i S S 5 p ____ zer E Cable to fan motor box Power cord 120 V 60 Hz WARNING RISK OF ELECTRIC SHOCK DO NOT TAMPER WITH ELECTRIC WIRING HAVE A QUALIFIED ELECTRICIAN MAKE AND TEST ALL ELECTRIC WIRINGS BEFORE USING OR STARTING HEATER Patron Climat 4 08 15 PATRON CLIMAT HEATERS LIMITED WARRANTY PATRON CLIMAT heater products are professional construction heaters They are war ranted for twelve 12 months from original date of purchase The warranty does not cover products modified outside our factory damage or failure caused by acts of God abuse misuse use on other than rated voltage abnormal usage faulty or improper in stallation failure to provide recommended maintenance or any repairs other than those provided by a professional licensed service person or facility to the oil burner and electri cal systems of the heater
14. om strong drafts or wind See that the heater is not exposed to water spray rain or dripping water MINIMUM CLEARANCES FROM COMBUSTIBLE MATERIALS OUTLET 36 in SIDES 36 in TOP 12 in FRONT REAR 36 in FLOOR COMBUSTIBLE Connect power cord of heater into a three hole grounded 110 120 V 60 Hz outlet See paragraph Technical specifications in this manual for correct amperage rating If an extension cord is used it must be a listed type Up to 50 feet long the extension cord must be rated 14 AWG 130A 12 AWG 50 to 100 feet long 12 AWG 130A 10 AWG 4 Plug the remote thermostat cable into the thermostat socket under the electric control box of the heater 5 Set the remote thermostat to a temperature above the ambient room temperature by turning the knob Note The heater will start only if the thermostat calls for heat mean ing that it is set to higher than prevailing ambient temperature If an remote thermostat is not used set the thermostat bypass switch to position Continuous Heat 6 Set the main switch into position The burner fan will now start to provide pre purge air After approx 10 seconds the burner will ignite and start heating NOTE If the burner fails to ignite push the red lighted reset button on the burner this is liable to happen when starting the heater after a longer storage period because the hoses are empty and it takes them a few seconds
15. to fill 7 After the heater has warmed up enough the main fan will start automatically 8 The heater will now operate automatically controlled by the ambient thermostat Make sure there is enough oil in the tank for continuous use Patron Climat 4 08 5 TO STOP HEATING 1 Turn the main switch into 0 OFF position ALLOW FAN TO RUN UNTIL IT STOPS AUTOMATICALLY DO NOT UNPLUG THE HEATER 2 Disconnect the power supply plug after the fan has stopped cooling the heater TO STOP HEATING WITH INTENT TO MOVE THE HEATER 1 Lift the wand above the oil level inside drum Allow oil hose to drain into the drum 2 Wait until the burner stops after using all oil left in supply hose 3 Turn the main switch into 0 OFF position ALLOW FAN TO RUN UNTIL IT STOPS AUTOMATICALLY DO NOT UNPLUG THE HEATER 4 Disconnect the power supply plug after the fan has stopped cooling the heater TO USE AS A VENTILATOR ONLY 1 Do not connect to oil supply 2 Plug heater to 110 120 V 60 Hz mains 3 Turn the main switch into FAN ONLY position 4 Unplug heater after use TECHNICAL SPECIFICATIONS HEATER MODEL GLIMATAOA CUMAT 1308 Dum 3 6 3 035760785 140760 55 4001607755 p Xd TS Patron Climat 4 08 6 STORAGE Close drum plug and coil the oil hoses Place oil wand in it s holder on the side of the heater Store heater in a dry clean and safe place out of reach of c
Download Pdf Manuals
Related Search
Related Contents
Téléchargement - Boehringer Ingelheim Sony MEX-BT2500 Operating Instructions small eq - Henry Schein Avaya 3456 UC Client - Communication Server 1000 User Guide Hy-PEM XP Series Installation and user manual user manual - An error occurred. READER SUITE USER MANUAL - Beta-eSTORE Dell X1 User's Manual Copyright © All rights reserved.