1. else be sure that they also receive this User Guide e ALWAYS make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture e This product is intended for indoor use only e To prevent risk of fire or shock do not expose fixture to rain or moisture e Make sure there are no flammable materials close to the unit while operating e The unit must be installed in a location with adeguate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked e ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type e ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles e DO NOT operate at ambient temperatures higher than 104 F 40 C e In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts e Make sure the power cord is never crimped or damaged e Never disconnect the power cord by pulling or tugging on the cord e Avoid direct eye exposure to the light source while it is on Caution There are no user serviceable parts in
2. HUSHPAR Theatrik LIGHTING Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2013 1 GETTING STARTED What s In The Box e 1 x HushPar Theatrik LED PAR Fixture e This Lovely User Manual Getting It Out Of The Box Congratulations on purchasing one of the coolest LED Par fixtures anywhere Now that you re the proud owner of a HushPar Theatrik or hopefully MORE you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition If anything looks as if it has been damaged in transit notify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to ma
3. ge which occurs in transit to us is the customer s responsibility so pack it well Shipping Issues Damage incurred in shipping is the responsibility of the shipper and must be reported to the carrier immediately upon receipt of the items Claims must be made within seven 7 days of receipt Page 6 HushPAR Theatrik Manual Rev A 2013 Blizzard Lighting LLC Tech Specs Weight amp Dimensions Light Source 36 3 watt white LEDs 100 000 hours Beam Angle 25 degree optics standard Luminous Intensity 27 600 Lux 1m 8 400 Lux 2m Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Other Information 3 9 of all women do not wear underwear 2 year limited warranty does not cover Warranty malfunction caused by damage to LED s Page 7 HushPAR Theatrik Manual Rev A 2013 Blizzard Lighting LLC Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting
4. ke sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit matches the line voltage applied Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch All fixtures must be connected to circuits with a suitable Ground Earthing Getting A Hold Of Us If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting N16 W23390 Stoneridge Dr Ste E Waukesha WI 53118 USA www blizzardlighting com 414 395 8365 Email support blizzardlighting com Disclaimer The information and specifications contained in this document are subject to change without notice Blizzard Lighting assumes no responsibility or liability for any errors or omissions that may appear in this user manual Blizzard Lighting reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time You can download the latest version of this document from www blizzardlighting com Page 2 HushPAR Theatrik Manual Rev A 2013 Blizzard Lighting LLC SAFETY INSTRUCTIONS Please read these instructions carefully They include important information about the installation usage and maintenance of this product e Please keep this User Guide for future use If you sell the unit to someone
5. nit for service Beam is Dim Check optical system and clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable No Power Power Check fuse AC cord and circuit for malfunction sd Check fuse AC cord and circuit for malfunction sd AC cord and circuit for malfunction Fixture Not Make sure all connectors are seated properly and securely Responding Check all cables for defects Responding Er Reset fixture s raticly Page 5 HushPAR Theatrik Manual Rev A 2013 Blizzard Lighting LLC Keeping Your HushPar Theatrik As Good As New The fixture you ve received is a rugged tough piece of pro lighting equipment and as long as you take care of it it will take care of you That said like anything you ll need to take care of it if you want it to operate as designed You should absolutely keep the fixture clean especially if you are using it in an environment with a lot of dust fog haze wild animals wild teenagers or spilled drinks Cleaning the optics routinely with a suitable glass cleaner will greatly improve the quality of light output Keeping the cooling vents free of dust and debris will keep the fixture running cool and prevent damage from overheating In transit keep the fixtures in cases You wouldn t throw a prized guitar drumset or other piece of expensive gear into a gear trailer without a case and similarly you shouldn t even think about doing it
6. side the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact Blizzard Lighting at support blizzardlighting com Page 3 HushPAR Theatrik Manual Rev A 2013 Blizzard Lighting LLC 2 MEET THE HUSHPAR THEATRIK LED PAR MAIN FEATURES 36x 3 watt Cool White 6500K daylight LED s Efficient convection cooling for zero fan noise Dual mounting yoke allows flexibility in positioning Rugged die cast aluminum enclosure Use with or without optional barn doors 100 000 hour life span Perfect Color Distribution SDC lt 0 006 OPTICAL e Installed optics 25 degree e 27 600 Lux 1m 8 400 Lux 2m e 100 flicker free dimming via conventional AC dimmer packs e PWM Frequency gt 7 8KHz COOLING ACOUSTIC e High performance fanless convection cooling e ZERO operating noise DIMENSIONS 11 46 inches 291 mm 12 76 inches 324 mm ae E E N Luni N x Ww o O n S 00 Q 15 28 inches 388 mm Page 4 HushPAR Theatrik Manual Rev A 2013 Blizzard Lighting LLC 3 SETUP Before replacing a fuse disconnect power cord ALWAYS replace with the same type and rating of fuse Fuse Replacement CAUTION The HushPar Theatrik utilizes a high output switch mode power supply with an internal fuse Under normal operating conditions the fuse should not require replacement The fuse is field replaceable however it is an ad
7. vanced procedure suited to qualified individuals Should your HushPar Theatrik fuse require replacement please contact Blizzard Lighting for instructions or to return your unit for service Mounting amp Rigging e Slide the barn door assembly into the grooves on the front of the fixture optional e Securely connect the power cable to a power socket Dimming can be achieved via the use of a conventional AC dimmer pack e This fixture may be mounted in any SAFE position provided there is enough room for ventilation e It is important never to obstruct cooling vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixture s weight to ensure structural stability Do not mount to surfaces with unknown strength and ensure properly rated rigging is used when mounting fixutres overhead e Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs e Safety cables MUST ALWAYS be used e Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Troubleshooting Symptom Solution Fixture Auto If it light output has stopped the unit may have shut itself off due to Shut Off high heat This is to protect the fixture from overheating Clear the cooling vents of obstructions or return the u
8. with your shiny new light fixtures Common sense and taking care of your fixtures will be the single biggest thing you can do to keep them running at peak performance and let you worry about designing a great light show putting on a great concert or maximizing your client s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once ina while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fixture should you ll need to obtain a Return Authorization RA Don t worry this is easy Just send an email to support blizzardlighting com and we ll issue you an RA Then you ll need to send the unit to us using a trackable pre paid freight method We suggest using USPS Priority or UPS Make sure you carefully pack the fixture for transit and whenever possible use the original box amp packing for shipping When returning your fixture for service be sure to include the following 1 Your contact information Name Address Phone Number Email address 2 The RA issued to you 3 A brief description of the problem symptoms We will at our discretion repair or replace the fixture Please remember that any shipping dama