1. Rain Master Irrigation Systems DX2 User Manual Chapter 2 System Basics The Evolution DX2 Controller contains a comprehensive feature set to support virtually any conceivable irrigation system configuration In addition to the more traditional irrigation features the controller supports multiple sensor inputs central communications control extensive fault diagnostics and specialized electronics to insure that product reliability is not compromised Through use of selected setup options the controller can be adapted to a specific irrigation application Although the controller provides numerous features and options the user interface remains extremely simple Consequently the operation of the controller remains user friendly Hd Ge a3 o D E S og 7 Chapter 2 System Basics Page 9 Rain Master Irrigation Systems DX2 User Manual Evolution DX2 Controller Front Panel The Evolution DX2 Controller Touch Key Front Panel provides all the necessary functions and control to operate and program the Evolution DX2 Controller Figure 2 1 Evolution DX2 Controller Front Panel identifies the location of all touch keys and features SAT 09 15 11AM VALID PGM NONE REMOTE 05 01 93 WK1 F1 MAIN MENU CONTROL PROGRAM ON OFF LANGUAGE DRAIN MASTER Figure 2 Evolution DX2 Controller Face Panel The Evolution DX2 Controller Front Panel provides the following features e The display cont
2. ains 2 lines each line capable of displaying 40 characters e Combination Day Numeric Key Pad e Enter Key Executes all keypad entries e Six Function keys used to select all program menus e Full Range Display Contrast Control Page 10 Chapter 2 System Basics Rain Master Irrigation Systems DX2 User Manual Program On Off Executes or stops any program Ability to select English or Spanish language Up Down Arrow Keys allow advancement through menus Immediate return to the base screen using the Quit key Distinctive beep validates each key entry Touch Tone Built in Remote Control Connector The display screen changes accordingly to the activity being performed Chapter 2 System Basics Page 11 Rain Master Irrigation Systems DX2 User Manual Base Screen After controller initialization see Chapter 3 the base screen depicted in Figure 2 2 is displayed SAT 09 15 11AM VALID PGM NONE 06 18 96 WK1 F1 MAIN MENU Figure 3 Base Screen e To alter the contrast of the display use the Contrast keys e The base screen displays the day time date and additional information depending upon how the controller is configured e The VALID PGM section of the screen alternates every seven seconds displaying either the program number s or the satellite address All existing programs will be listed Dashed program numbers such as 2 5 indicate a range of programs which includes all num
3. base screen The QUIT key bypasses any previous screens and displays the base screen Press LANGUAGE to change from English to Espanol or from Espanol to English Press the PROGRAM ON OFF key to immediately turn a program on or off Page 16 Chapter 2 System Basics Rain Master Irrigation Systems DX2 User Manual Beep Responses To provide user feedback for keyboard entry two different beeps or tones are omitted A single beep indicates a valid or correct entry Rapid successive beeps indicate an invalid entry For example from the base screen select F1 and a single beep is heard This indicates F1 is a valid selection However from the base screen select the down arrow and multiple beeps are heard System Configuration The DX2 Evolution Controller is housed in an all weather enclosure containing the following assemblies e Keyboard Main Panel Assembly e Main Power Switch Box Assembly e Master Valve Pump Power Board Assembly e Station Output Board Assembly Quantity varies depending on station configuration e Communication Board Assembly Optional e Sensor Terminal Board Assembly Optional Keyboard Main Panel The Keyboard Main Panel assembly consists of a main microprocessor control board and an optional sensor control board which would attached to the main board Four cables from this assembly provide the connections to the additional internal assemblies which include the Master Valve Pump Po
4. bers within the range Numbers separated by commas such as 2 4 and 6 indicate individual program numbers e When the Evolution DX2 controller displays the base screen information the controller functions in the automatic mode meaning that any valid program s will automatically start at established program start time s e The manual function see Chapter 8 disables the automatic mode The controller has a built in time out function 2 hour time out which returns the controller to the base screen automatic mode if the user inadvertently leaves the controller in some other screen Page 12 Chapter 2 System Basics Rain Master Irrigation Systems DX2 User Manual e User prompts for valid keystroke entry are designated by vertical bars with the key name appearing between the bars e The ene F1 MAIN MENU prompts the user to press the F1 key to access the Main Menu e From the base screen pressing F1 will display the main menu Chapter 2 System Basics Page 13 Rain Master Irrigation Systems DX2 User Manual Main Menu The main menu indicates five of the function keys used to access different functions F Keys Up Arrow Figure 4 Main Menu Note The F1 key which was previously used to select the main menu is now used to select the Program option The use of the function keys changes depending upon the contents of the screen display I This symbol in the main menu indicates you pre
5. n Figure 2 4 1 Keyboard Main Panel 2 Main Power Switch Box 3 MV Pump Power Bd 4 Station Output Bd 5 Communications Bd 6 Sensor Terminal Bd Figure 5 Pedestal Controller Assembly Layout Page 20 Chapter 2 System Basics Rain Master Irrigation Systems DX2 User Manual NEUTRAL WHITE y ol BAWG UNE PLACK d GROUND GROUND GREEN o UG 45 CONNECT USING PROPER S CONDUITTO CODE EEEN CONNECT 1204 50 40HZ SUPPLY UNE TO TRANSFORMER WIRES WITHIN THE CONDULET CONNECT GRO UND WIRE TO GROUND LUG INSIDE OO NTROL CABINET AND OTHER END TO 5 8 x 8 COPPER CIAD GROUND ROD DEG Om Figure 6 AC Power Supply Wiring Diagram Chapter 2 System Basics Page 21 Rain Master Irrigation Systems DX2 User Manual MASTER VALVE ZONE2 VALVE PCDX2 MV 66 9 6 Dp Ovo PCDX2 0T12 1234567 8 9101112 5 9209009000000 O o KEE STATION 2 MVI MV2 N O PUMP COM o TO MASTER VALVE TO ZONE 2 VALVE DAGOKWIOA Figure 7 Master Valve and Station Connection Page 22 Chapter 2 System Basics
6. s security systems etc A Station Output board may be configured with six stations or 12 stations The controller enclosure will accept a maximum of four output boards providing control for a total of up to 48 stations Each board is equipped with two common terminals used for circuit ground return All common terminals of a multiple station configuration are essentially identical and may be interchanged among the boards for wiring convenience Page 18 Chapter 2 System Basics Rain Master Irrigation Systems DX2 User Manual Communication Board optional The Communication Board provides the means for communication among controllers and or the Central Computer The available communication options are Hardwire Radio or Phone communication provides the capability for any number of configurations Sensor Terminal Board optional The Sensor Terminal board provides the direct link between the flow sensors and or weather station devices and the controller The flow and weather sensing option provides four sets of terminal connections two inputs for flow sensors or one flow and one ET one input for a rain sensor and one input for a wind sensor All inputs are dedicated and calibrated to their respective weather devices Chapter 2 System Basics Page 19 Rain Master Irrigation Systems DX2 User Manual DX2 Pedestal Controller Assembly Layout The assembly layout location within the controller enclosure is depicted i
7. ss the up arrow key on the controller to return to the previous display In this case the previous display is the base screen The previous screen would change depending upon which menu options function keys you had previously chosen Page 14 Chapter 2 System Basics Rain Master Irrigation Systems DX2 User Manual Using the Controller Keys Throughout this manual the following symbols are used to represent the controller keys you use to move through the menu options and to view or change the settings of your Evolution DX2 controller H F Press the associated function key F1 to F6 to select the option shown on the display screen Press the up arrow key to move to the previous screen Press the down arrow key to move to the next screen D Il la La Use the numeric keypad section to enter numbers Alco SAT Use the keypad section to enter days of the week sus won Tue Chapter 2 System Basics Page 15 Rain Master Irrigation Systems DX2 User Manual Function Keys continued LIGHT ENTER QUIT LANGUAGE PROGRAM ON OFF Press the DARK key to increase display contrast and the LIGHT key to decrease display contrast Note Maximum LIGHT setting will appear as a blank display The ENTER key is used to complete entry of a number or day of the week For example to ENTER the number 1 press the 1 key and then press the ENTER key Press the QUIT key to immediately go to the
8. wer board the Communications board optional the Sensor Terminal optional and the Station Output board s Chapter 2 System Basics Page 17 Rain Master Irrigation Systems DX2 User Manual Main Power Switch Box The Main Power Switch Box assembly contains the controller main power switch a dual ground fault interrupter receptacle and a step down transformer delivering 12 VAC and 24 VAC The ground fault interrupter GFI provides an exclusive safety feature against electrical power hazards The GFI can sense and detect any degree of power line shorts and will immediately shut down the power preventing electrical damage or injury The GFI includes a Test switch and a Reset switch When the Test switch is pressed all power will shut down indicating proper operation of the internal control circuitry Pressing the Reset switch will restore power operation The diagram of Figure 2 5 identifies the Main Power Switch Box and associated wiring Master Valve Pump Power Board The Master Valve Pump Power board provides the four outputs for Master Valve 1 Master Valve 2 Normally Open Valve and Pump Additionally the assembly distributes the 12 VAC and 24 VAC through their respective fuses to the associated controller assemblies Figure 2 6 illustrates typical connections for Master Valve and Station connections Station Output Board The Station Output board delivers the 24 VAC required operating valve solenoids lighting system
Download Pdf Manuals
Related Search
Related Contents
PXL33 Reference & Maintenance Manual Polk Audio RTi Series User's Manual Fujitsu ESPRIMO P900 Samsung RW33 Wine Cellar with Lock & Key, 148 L User Manual RISCOS FÍSICOS Page 1 Page 2 (Page) 懸 安全上の注意事項 はじめに 標準セッ ト ー manual de instalación de polar fis+ para skoda octavia - Auto Manual - Tramontina wifi_disk_user_manual_(Full Version). Copyright © All rights reserved.