Home
ETG30 Freeze Fat Dissolving Instrument
Contents
1. 7 N N p gt J 8 polar RF revolving work head Service brake jack Transportation amp Installation Before transportation The coolant should be cleared before transportation Method Open the coolant discharge valve 13 as the picture shows turn anticlockwise and fasten the pull out the stopper discharge the coolant move the machine to help the coolant get out completely Notice While discharging the coolant the cooling handle should be placed at the handle support Installation steps 1 Aim the screen at the screen module fixing pedestal fasten with three M4 hexagonal screws tightly and then the installation of the screen module is completed 2 Aim the support discreteness at the support discreteness fixing pedestal fasten with a M4 hexagonal screw tightly and then the installation of the support module is completed 3 Put the accessory bracket above the accessory bracket support block aim the screw hole at the fixing hole of the accessory bracket support block fasten with four M8 hexagonal screws tightly and then the installation of the accessory bracket is completed 4 Place the handle as the picture shows finish installation Y Support discreteness M8 hexagonal screw Support discreteness fixing pedestal Accessory bracket 200000 200001 700001 a L Coolant discharge va
2. Insert F1 freeze fat dissolving board to 8 6 Insert cooling work head to 9 3 Insert power line to 11 turn on the General power switch 10 4 In interface as Fig 1 shows input default Fig 1 password 000000 to enter interface Fig 2 5 Click any place of the screen to enter interface Freezefat Fig 5 some Freeze fat dissolving function An innovative weight loss method which in contrast with the traditional heat therapy freeze fat dissolving method is a revolutionary new concept of weight loss It is very suitable for removing local fat particularly aim at difficult to getrid of waist and belly fat As triglyceride in fats will be converted into solid in particular low temperatures It uses Freezefat advanced cooling technology to selectively LURE SYSTEM ETG30 target fat bulges and dissolve fat cells througha gradual process that does not harm the Surrounding tissues reduce unwanted fat When fat cells are exposed to precise cooling they trigger a process of natural removal that gradually reduces the thickness of the fat layer And The fat cells in the treated area are gently dissolved through the body s normal metabolism process to dissolve unwanted fat Freeze operation steps Please checking whether the numerical value of the cooling fluid display window is above 4 5 before open the machine If itless than 4 5 please add coolant to avoid the bad effect on the cooli
3. X Indicates that the content of toxic or hazardous substance in at least one of the homogeneous materials for this part exceeding the SJ T11363 2006 limit requirement 1363 2006 Technical note Hardware structure of the machine parts injection molded parts and the majority of electronic components connectors meet the requirements of the EU and China RoHS directives Only a few parts as the global technology limitations that may affect product reliability and not find a substitute for the toxic and hazardous substances please be assured to use use under normal conditions will not cause health effects on users Products to be discarded after use Please treat in accordance with electronic and information products recovery re use legal regulations 11 Treatment table Name Sex Age NO Height Weight Heart rate Ask before treatment 1 Have liver disease or not Yes Nol 2 Have Raynaud s disease or not Yes Nol 3 Have severe diabetes or not Yes Nol 4 Have cold hyperfibrinogenemia or not Yes Nol 5 Have cryoglobulinemia or not Yes Nol 6 Have serious cold urticaria or not Yes Nol 7 Have surgery during the year or not Yes Nol 8 Have done more than 2 parts of cryotherapy in a month Yes Nol If any answer is yes please do not accept this therapy Customer Signature Part 1 Treatment start date D M Y Treatment time min Temperature C Mark
4. insert earphone to 15 if use the function 2 Click basic setting enter interface as Fig 12 1 Select language 2 Regulate date and time 3 Regulate brightness of the screen 4 Click calibration enter interface as fig13 for calibrating the screen 5 keys recovery back Notes advanced setting is for manufacturer only Maintenance 1 Appliances and medical equipment close to the equipment may be resulting in operational failure due to Interference 2 Prohibit use of the equipment in the following environment Hot and humid environment Dusty environment Environmental with much smoke or stream 3 lf there comes a failure please shut down the power immediately and send it to the distributor or manufacturer for maintenance Do not repair by yourself 4 The cooling fluid is pure water or special cooling fluid keep it clean during transportation or long time no use And should be filled properly before use 5 Exclusion of liability The Company is not responsible for the following circumstances 1 If fire earthquake war occurred 2 The fault of the user operator error 3 Damage caused by using other method not included in the use manual 4 Operate without the manual s guide 6 After using the machine for over 40 hours please take off the dust filter 12 and clean it 7 Do not make the machine close to the wall keeping a 30CM space around for cooling Simple Troubleshooting When the instrument ap
5. is over 10 Clean the leftovers with hot towel use warm towel to clean the ultrasound head Caution D zi 1 There should be enough gel when using fat cavitation explosion head 2 Fat cavitation explode head should not stay still at one a K Cs F i part for too long time and do not use It on bones SP 3 Please step on service brake then there will be sound wave exist when using fat cavitation explode head 4 Fat cavitation explode head can not be used on the back avoid on the bones and daily care should be within 30 n P RA RA eS 1B El Fig 11 3 2045 18 00 Bi TPP RF amp fat cavitation headF orbidden group Nm E l l A A A A t 1 People who has fever infectious diseases acute A Hir De diseases 2 People with heart disease or configured cardiac pacemaker 4 C omen ik HEEZE 3 Patients with severe high blood pressure tumor 5 disease asthma deep vein thrombosis varix thyroid Fig 12 cancer falling sickness 4 People with hemorrhagic disease trauma vascular rupture skin inflammation skin disease 5 Pregnant women 6 Do not use at the abdomen during menstrual period 7 Medical Plastic parts or parts with metal inside 8 People with an abnormal immune system CE ip Click set in the left corner in interface as Fig 2 shows to enter interface Fig 3 1 Click mMultimedia to enter interface as Fig 11 insert USB disk to 14
6. the treatment area and assign a number L Mark the treatment area and assign a number right Countercheck 2 months after treatment Good effect Ordinary The second course start date D M Y Treatment time min Temperature C Countercheck 3 6 months after treatment Good effect Ordinary Please take photos before and after treatment Part 2 Treatment start date D M Y Treatment time min Temperature C Countercheck 2 months after treatment Good effect Ordinary The second course start date D M Y Treatment time min Temperature C Countercheck 3 6 months after treatment Good effect Ordinary Please take photos before and after treatment Use this form please copy
7. ETG30 Freeze Fat Dissolving Instrument User manual CE No AGC05E110301 2E Warning Dear user Thanks for using our company s products in order to fully make use of the products we sincerely suggests follow Please read the instruction in detail and keep it well for further reading and consulting Please follow the instruction to fit and operate the machine correctly Please do not remove and change any accessories of the machine It forbids others to open and remove the mainframe except the authorized people in the company it forbids others to change and maintain the machine except the professional people Please contact us if there is any trouble during operation This product does not belong to medical please don t use for disease treatment Parts Introduction N p F1 freeze fat dissolving board x 40K Fat cavitation head CONDO OF WN gt Coolant inlet Overflow Coolant level window 40K Fat cavitation head jack Service brake jack 8 polar RF revolving work head jack F1 freeze fat dissolving board jack F2 freeze fat dissolving board jack 9 10 General power switch 11 Power supply line jack 12 Dust filter 13 Coolant discharge valve 14 USB outlet for multimedia function 15 Earphone jack Cooling work head jack N s N J F2 freeze fat dissolving board Cooling work head
8. call the Customer Service Department Technical Parameters 1 Input 220V 50Hz O 110V 60Hz O 2 Power lt 350 VA 3 Cryo 5 Cto 5C 4 Cooling liquid Pure water or special coolant 5 Volume 65cmX55cmX150cm 6 Fuse T3 15AL250V 7 Ambient temperature 5 C 40 C 8 Relative Humidity lt 80 Accessories List 1 Host 2 Power supply line 3 User manual 4 8 polar RF revolving work head 5 40K fat cavitation work head 6 F1 freeze fat dissolving board 7 F2 freeze fat dissolving board 8 Cooling work head 9 Service brake 10 Accessory bracket 11 Support pipe 12 Two pieces of liguid addition accessory 13 Band ties 14 White fast connection sealing ring 15 M7 hexagonal screw driven 16 M3 hexagonal screw driven 17 M8 hexagonal screw 18 M4 hexagonal screw 1set 1pc 1copy 1pc 1pc 1pc 1pc 1pc 1pc 1pc 1pc 1set 4pcs 20pc 1pc 1pc 4pcs 4pcs 10 Safety and Environmental Considerations Names and contents of Toxic and hazardous substances or elements Hazardous Substances Part Name NOTE Pb Hg Cd Cr VI PBB PBDE Plastic parts O O O X x Metal structures decorations x O O O O O Circuit board Components x O O O O O Power Line X O O O O O Power cord X O O O O O Relay O O X O Buzzer xX O O O O O Remarks said that the content of hazardous substance in all materials in the parts below the standard of SJ T11363 2006 limit reguirement
9. e skin 13 Clean the leftovers with warm towel on the freeze fat dissolving board 5C a 2 UA KAA Cool operation steps 1 Clean treatment area 2 Click Cool in interface as Fig 5 shows to enter Fig 6 interface 3 Set temperature the range is 5 C to 5 C Must use the antifreeze if the setting temperature is below 2 4 Click Time to enter interface Fig 7 press numbers setting work time click OK button after input numbers Each part operating time about 45 minutes do not overrun 60 minutes every time If you put wrong number please press the number above the clock picture the wrong number will be deleted 5 Click Cool in interface Fig 7 it will return to interface Fig 6 Click start the machine began to work 6 Beautician hold the cooling work head to move slowly on skin in circle repeatedly or location frozen 7 The machine will pause automatically if the setting time is over 8 If you use the machine continuously please click the screen according to hint click needed Function button in interface Fig 7 Freeze fat dissolving Treatment Setting 1 30 60 minutes for each part every treatment depending on thickness of fat and health status 2 You can only treat cellulite one or two parts every treatment for example to dissolve cellulite of the entire waist you need to complete several courses Please do not treat more than two parts of body in the same cause of treatme
10. high frequency current bring along Electronic fast moving in body tissues resulting in heat and to make deep tissue warming and enhanced cell active function improve lymphatic circulation which can effectively burn fat eliminate cellulite to attain with lifting and tightening skin slimming and shaping effect 1 Click RF in interface as Fig 5 shows to enter Fig 9 interface 2 Regulate output intensity of RF 1 weak 10 strong 3 Set work time 20 minutes every part 4 Click start the machine began to work 5 Applied gel on treatment part beautician hold the 8 polar RF revolving work head to move slowly on skin in circle or beeline repeatedly Eight electrode probes must be fully in contact with skin Do not stay on any part without moving 6 The machine will pause automatically if the setting time is over 7 Clean the leftovers with hot towel use warm towel to clean the RF work head Caution 1 Beautician should wear insulated gloves during operation 2 Do not wear any aglet both for the beautician and the users 3 The electrode probe must be fully in contact with skin 4 Do not make the RF electrode stay on any part without moving keep it moving on skin slowly 5 8 polar RF work head only apply for body treatment Do not use for facial 40K fat cavitation head 40K ultrasound fat cavitation work head applies the cavitation theory uses the 40KHz ultrasound to make intense vibration which causes a inne
11. lve 3 Before installation Installation finished Add Coolant Steps 1 Use purified water or special coolant 2 Make sure the coolant discharge valve is closed 3 Use special funnel to connect to coolant entrance 1 4 Add purified water or special coolant from the funnel 5 Add liquid until there is overflow from 2 6 Check from the window 3 whether the liquid is full 7 Add cooling fluid successfully first time 8 Connect power supply line 11 turn on general power switch 10 input password 000000 in interface as Fig 1 shows enter interface as Fig 2 click P at the left lower corner enter interface as Fig 3 Click Liquid setting enter interface as Fig 4 shows click Start to become counter down 9 When stopped please observe the status of liguid coolant window if it doesn t arrive at level 4 5 please add cooling fluid again until the level is above 4 5 then take off the funnel NOTE Add about 1L pure water or special cooling fluid change the water after 3 months BEA s JEUDSI WIJS eA U I E Wegue Inod Fig 4 Basal Operation 1 Please take out the bracket and accessories shelf install them to mainframe 2 Connect the accessories to the host Insert 40K fat cavitation head to 4 2 Insert service brake to 5 3 Insert 8 polar RF revolving work head to 6 insert F1 freeze fat dissolving board to 7
12. ng system 1 Check the thickness of the fat with the help of fat pliers testing 2 Clean treatment area 3 Mark the size of treatment area gt 4 Open antifreeze and paste antifreeze membrane F1 indicator light on treatment area Fig 5 F2 indicator light 5 According treatment part to select suitable bind ties and binding it well 6 In interface as Fig 5 shows the indicator light of F1 F2 freeze fat dissolving board is blue It means A that the state is standby N A When using F1 and F2 in the same time setting the temperatures and time separately y then click the start button B When only using F1 click the indicator light of F2 and the light turns red It means closed Then click the start button the picture of F1 is blue C When only using F2 click the indicator light of F1 and the light turns red It means closed Then click the start button the picture of F2 Is blue 7 Put fat dissolving board F1 or F2 in bind ties that binding well 8 Click A Y to set temperature the range is 5 C to 2 C 9 Click A Y to set work time the range is a E m a 1 00 60 00 minute Each part should be within 60 Tim minutes every time L hed a 10 Click start the machine began to work 11 The machine will pause automatically if the Fig 7 setting time is over Beautician take the freeze fat dissolving board out first and put it well then loose the bind ties 12 Cleaning th
13. nt 3 Take another cooling procedure at the same position 2 months after the first course which can reduce the extra fat layer thickness twice treatment can enhance the effect of cryolipolysis but not recommended to accept treatment repeatedly at random 4 The cryolipolysis treatment designed for localized hypertrophic fat accumulation area physical healthy people but not suitable for overall obesity Treatment mainly for a particular part such as waist fat belly and back and other local cellulite Treatment is not omnipotent and can not cure obesity it can not replace liposuction or other invasive therapies A Substantial weight loss should be through a balanced diet and do regular exercise cryoli polysis treatment can only be carried out for extra fat 5 Qualified antifreeze should be used during the treatment that avoid frostbite when temperature lower to The O to 40 degree Consumables purchase on your own After Treatment Damage minor frostbite skin pigment may occur at the treatment area care properly 1 The equipment must be operated by professionals 2 Observe the status of cooling fluid display window before operating everyday the level can tless than 4 5 3 Banned in no case of anti freeze membrane treatment during the course of treatment must ensure anti freezing film completely cover the rapeutic part otherwise can appear frostbite etc 4 Cautions especially The same people please do not treat a large area
14. of body or treat the adjacent part of the body that have been treated in the same course of treatment in 1 2 months As Fig 8 shows if you operate of part O you can not operate the part or part 4 so you can only operate part If you against this regulation Light will cause the metabolic disorders Heavy then cause metabolic acidosis and the toxins from the body doesn t stranded 5 Patients using the following medical electrical equipment can not use the equipment Implanted cardiac pacemakers or other implanted electronic devices Life sustaining artificial heart lung machines and other equipment Portable ECG measurement equipment 6 The following patients should be agreed by the professional doctors before using the equipment Patients with acute disease Malignancy Patients with Infectious diseases Pregnant women ap Patients with heart diseases Patients with fever Patients are receiving treatment or those with abnormal body phenomenon 7 The following patients using this device should be taken care of Sensory or physically impaired persons Left Right Contraindications Liver problems The Raynaud s disease Severe cold urticaria Cryoglobulinemia Cold fiber hypoproteinemia Severe frostbite Severe diabetes and the elderly young children frail and so intolerant of cryotherapy 8 polar RF revolving function Via the constantly changing
15. pears fault during the operation the user could diagnose and rule out some simple questions through the following guides If still not resolved please call our Customer Service Department for consulting as soon as possible 1 Nothing happens when turning on the general power switch 1 Ensure that the AC power is normal or not 2 Ensure that the power supply line is broken or not 3 Ensure that the power plug is plugged in tight or not 4 Ensure that the fuse is normal or not 2 The touch screen failure 1 Touch screen click on invalid May be the touch screen is pressed please gently press the four corners and the center of The screen then turn off the instrument wait for one minute then restarts it 2 Positioning error of touch screen Turn on the instrument enter interface of calibration If the problem still exists please call the Customer Service Department 3 lf the touch screen is broken please call the Customer Service Department 3 Touch screen display error Please turn the power off wait one minute after a reboot If the problem still exists please call the Customer Service Department 4 After starting ten seconds the screen shows that Flow sensor fault To add water or not 1 Check wether the connection of the equipment to handle is being pressed or folded please 2 Check the level window display 3 of the instrument back panel if lower than 4 5 add water please 3 If the problem still exists please
16. r explosion in the fat tissues thus get rid of lipocyte It can effectively break down stubborn and deep fat decrease lipocyte quantity and its size The diathermal can promote lipocyte and tissues liquid flow which help drainage of fatty acid waste and toxin through lymph system The vacuum function will promote liquid flow of f lipocyte and fat tissues then speed up excretion of toxins and waste achieve effect of fat elimination slimming skin tightening and enhancing muscle flexibility 1 Click 40K in interface as Fig 5 shows to enter Fig 10 interface 2 Applied gel on fleshy parts eg abdomen hip thigh The amount depends on moving flexibility of the fat cavitation work head 3 Regulate output intensity CSW 15W 30W 40W 50W 4 Set work time 15 minutes every part 5 Click start put the service brake under your feet step on to start working move away for pause mmm T a EN CA CA CE K L UA UI Fig 10 6 Beautician hold the fat cavitation work head to move slowly on skin in circle or beeline Repeatedly the other hand push the fat towards the ultrasound head 7 Do not use on back avoid using on bones 8 Do not use on uterus part when women do abdomen care Abdomen treatment during menstruate should be avoided Enough gel are needed you may feel painful if medium is not enough The total treatment time for daily care should be within 30 min 9 The machine will pause automatically if the setting time
Download Pdf Manuals
Related Search
Related Contents
Francais Manuale d`istruzioni Termocamera PCE-TC-31 manual de instrucciones nevera nv Philips Softone Energy saving bulb 8718291682646 「資料2」 (ファイル名:26-02-6_shiryou2 サイズ:2.21MB) owner`s instructions manual de instrucciones manuel d`utilisation Frigidaire FFQG5000QW Wiring diagram Sony XS-S1300 User's Manual TM-850 - Providing Marketing Solutions for Over 30 Years! Copyright © All rights reserved.