Home
AN 0E
Contents
1. AEQ PHOENIX AUDIOCODECS APPLICATION NOTE 0 E AEQ Phoenix Studio units through Internet Complex scenario configuration Through LOCAL network s DHCP not used manual NAT Using SIP Direct mode The most convenient and reliable way to connect an IP codec to a remote one through Internet is by means of a dedicated exclusive Internet access DSL cable modem In this application note a way to achieve the same result will be proposed when this is not possible as Internet access is shared with other equipments connected within a managed LOCAL LAN and DHCP is not available or convenient This application note describes the recommended procedure when AEQ SIP Proxy is not reachable or we don t want to use it and SIP signaling is used from end to end with no servers involved As we need to get access to Internet a shared resource in this case it is mandatory to contact the network administrator in order to have the required resources enabled and gather all the necessary information This document shows the specific steps to make this connection possible in the most general way possible although some verification procedures have been omitted in order to ease the reading and some particular situations may be easier to solve that the presented one For a detailed explanation of every step and for details on how to configure other options that may be more convenient for other cases the reading of the rest of application notes as well as
2. the status call status and the different phases it steps through CALLING CONNECTING SYNCHRONIZING and finally CONNECTED Verify that the SYNC LED situated under the CALL key is lit in green color as an indication that the communication has been correctly established and synchronized You should hear audio from Phoenix Master in the headphones Established connection detail Be sure that ON AIR is activated for that communications channel in order to allow the full duplex audio transmission from to the associated XLR connectors Once the connection is well established it can be repeated as many times as necessary varying the audio coding algorithm until the best possible quality is reached given the network conditions Menu CH1 STATUS gt CODING List The audio coding algorithm lists are created by entering MAIN STATUS gt SYSTEM gt 10 SIP CODEC PROFILES 5 MAKING A CALL TO OTHER PHOENIX CODEC OR TO A N ACIP COMPLIANT CODEC The calls to Phoenix Master or Phoenix Master 2 have been automatically answered To make a manual call to other codec it is necessary to configure the second one the same way if it is connected to a managed local network or in a simpler way if it is connected to Internet directly through an ADSL router or cable modem with DHCP server as explained in the corresponding application notes ANOA or ANOB Once the reporter unit can connect properly to Phoenix Master 2 you can create in the phone boo
3. A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU Verify that the green LED in the connected Ethernet port at the back of the equipment blinks indicating that there is traffic in the IP connection Configuring the ETH1 port Go to menu MAIN STATUS gt SYSTEM gt 8 SETTINGS gt ETHERNET SETTINGS ETHERNET MODULE 1 where we will set up the following parameters DHCP OFF IP type the LOCAL IP from paragraph 1 1 for example 172 26 5 59 MASK type the network mask from paragraph 1 2 in for example 255 255 0 0 GWAY fill with the Gateway IP address for Internet access from paragraph 1 4 for example 172 26 1 1 DNS type the IP address of the DNS server paragraph 1 3 for example 172 26 1 1 Ethernet 1 port configuration screen Select the PROXY SIP operating mode from the menu MAIN STATUS gt SYSTEM gt 5 INTERFACES gt NET 1 gt MODE 3 OTHER POINTS TO CHECK We are now going to quickly overview the rest of configuration menus where it is recommended to check that every parameter is correctly configured At MAIN STATUS Chn1 Net 1 ONLY G722 OK Press the encoder button SEL to modify the parameters this channel s parameters INTERFACE Net 1 IP CODING List ONLY_G722 for a start we can test other modes with better quality afterwards If the coding lists need to be edited select option 10 from SYSTEM menu AUDIO IN SOURCE ANALOG for analog X
4. 70 180 170 SIP PUBLIC PORT here you must type the value provided by the network administrator in paragraph 1 7 for example 8000 RTP LOCAL IP can t be modified here Must match the value assigned by the network administrator according to paragraph 1 1 for example 172 26 5 59 RTP LOCAL PORT can t be modified here Must match the value provider by the network administrator according to paragraph 1 6 for example 5004 RTP PUBLIC IP here you must type the PUBLIC_IP value provided by the network administrator in paragraph 1 5 for example 212 170 180 170 RTP PUBLIC PORT here you must type the value assigned by the administrator in paragraph 1 7 for example 8002 APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU 4 MAKING A TEST CALL TO PHOENIX MASTER Finally we are going to revise the adequate configuration of the equipment and prepare it to make a test call to an unit called phoenixMaster sip aeg es that AEQ maintains at the disposal of its customers continuously transmitting audio and with reachable in the public IP 212 170 163 189 at the time of writing this document We recommend that a pair of headphones is plugged to the front outlet or a couple of monitor speakers are connected to the back side XLR outputs It is also advisable that the PHOENIX MASTER and PHOENIX MASTER 2 are added to the phone book for future tests Go t
5. CTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU
6. LR inputs APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU BACK UP Set it up afterwards only if backup on other physical interface is needed RX BUFFER MODE ADAPTATIVE RX BUFFER MAX 1000 in milliseconds It should be reduced dynamically if no dropouts are detected Rest of parameters set them up after reading the manual and according to each particular need Net 1 DIRECT SIP OK Press the encoder button SEL to modify the parameters this logical interface s parameters MODE DIRECT SIP If this is not the set mode press the encoder button to change it to MODE DIRECT SIP Press ADVANCED soft key to gain access to the logical interface configuration Go to USER and type a user name Access AUDIO menu and check that LOCAL INTERFACE is ETH1 LOCAL PORT is the same that the network administrator has opened for audio paragraph 1 6 5004 by default SYMMETRICAL RTP is ON Access NAT TRAVERSAL check that MODE MANUAL ROUTER CONFIG SIP LOCAL IP must match with the value assigned to LOCAL IP paragraph 1 1 for example can t be modified here SIP LOCAL PORT must match the value provided by the network administrator paragraph 1 6 for example 5061 can t be modified here SIP PUBLIC IP here you must type the PUBLIC_IP value provided by the network administrator according to paragraph 1 5 for example 212 1
7. User Manual s chapter 4 is recommended 1 NETWORK ADMINISTRATION INVOLVEMENT We will need that the Network Administrator 1 Provides us with a valid internal IP within the local network for example 172 26 5 59 for sending SIP signaling as well as audio using RTP protocol Both IP will be the same in both cases and we will refer to it as LOCAL IP 2 Indicates us the Network Mask for example 255 255 0 0 3 Tell us the DNS server IP address for example 172 26 1 1 or a valid external DNS server for the country we are working at If it is not provided we will still be able to operate provided that we know the IP address of the SIP Proxy although it is always recommended to specify it by its DNS name 4 Provides the Gateway IP address as an example 172 26 1 1 5 Indicates us the network Public IP address In most cases there will be a single public IP for SIP signaling and RTP traffic We will refer to it as PUBLIC IP for example 212 170 180 170 APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aeq eu 6 Opens the required ports for audio and signaling These ports are by default e SIP signaling PORT SIP LOCAL PORT we will obtain it from the equipment which will assign port number 5061 by default when in the NAT TRAVERSAL MANUAL mode It is recommended that port 5062 is also opened just in case we want to use both channels of the unit
8. k a contact with the name and URI of the other unit as explained for the Phoenix Master contact in the previous chapter and the call can be directly made You can also send the call without having previously created a contact in the Phone Book Just select the Chn 1 line in the MAIN STATUS screen press the CALL corresponding to CH1 the leftmost one and you will reach CH1 CALL MENU Then select the URI line and edit it in order to type the other equipment s URI Now just validate by pressing the encoder button and press the DIAL soft key APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU The other equipment CALL LED will blink and the buzzer will sound if it is configured to do so When you press the blinking CALL key the communication should be established and the SYNC LED should become green in both ends of the communication If you press the ON AIR key the audio from the XLR input will be sent and the audio from the opposite unit should be received in the headphones In order to set the buzzer go to MAIN STATUS gt SYSTEM gt 8 SETTINGS and select BUZZER ON For more information and other configuration options please read the User Manual and Application Notes corresponding to other scenarios If you still have doubts please don t hesitate to contact one of our assistance services sat aeq es support aeaqbroadcast com APLICACIONES ELE
9. o MAIN STATUS gt SYSTEM 2 CONTACTS screen PHONE BOOK Press the soft key INSERT Following the guidelines in chapter 3 1 2 of the User Manual fill a name and URI for Phoenix Master have in mind that key switches between upper case lower case and numbers and that the space is inserted with key 0 NAME PHOENIX MASTER TEL lt leave this field blank gt TEL2 lt leave this field blank gt URI phoenixMaster2 212 170 163 189 5061 case sensitive NAME PHOENIX MASTER2 TEL lt leave this field blank gt TEL2 lt leave this field blank gt URI phoenixMaster2 212 170 163 189 Note that PHOENIX MASTER URI has a port number preceded by the symbol after the IP address In the case of PHOENIX MASTER 2 the port used for SIP is 5060 the standard one so we don t need to add 5060 at the end Return to MAIN STATUS screen and place the cursor over Chn1 Press the CALL key associated to the first channel of the audiocodec which is the leftmost one of two keys at the front panel of AEQ Phoenix Studio This will present the connection configuration menu CH1 CALL MENU Press PHONE BOOK place the cursor over PHOENIX MASTER or PHOENIX MASTER entries that we previously created and press DIAL soft key to initiate the call APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU The OLED screen sometimes fast
10. using two different SIP proxy servers e Ports for audio transmission and control RTP and RTCP protocols 5004 and 5005 respectively e STUN ports 3478 amp 3479 7 Assigns public ports for SIP RTP and RTCP for example 8000 8002 and 8003 respectively and do a port forwarding that translates the PUBLIC IP public port pairs to each LOCAL IP Phoenix configured port pair e SIP PUBLIC PORT to SIP LOCAL PORT for example PUBLIC_IP 8000 to LOCAL_IP 5061 e RTP PUBLIC PORT to RTP LOCAL PORT for example PUBLIC_IP 8002 to LOCAL_IP 5004 e RTCP PUBLIC PORT to RTCP LOCAL PORT for example PUBLIC_IP 8003 to LOCAL_IP 5005 Note that public port numbers can be the same as local ones 5061 5004 5005 unless the administrator decides the opposite because they are already in use or there are other IP codecs or SIP equipment in that local area network 2 CONNECTING AND CONFIGURING THE UNITS The physical connection will be done to a LAN port e Connect the network cable to the LAN1 port at the back of the AEQ Phoenix Studio Connect the other end to the Ethernet port we have been assigned within the LAN e Connect the analog or digital audio inputs and outputs to the connectors at the back of the AEQ Phoenix Studio e Connect the IEC mains cable to the back of the AEQ Phoenix Studio e Turn the power switch ON and verify that the front display shows the AEQ logo after some seconds APLICACIONES ELECTRONICAS QUASAR S
Download Pdf Manuals
Related Search
Related Contents
DS6878 Sony PCG-GRT100 Replacement Instructions Muvit MUSLI0623 mobile phone case Operating Instructions - VEGASON 62 FSP065-REB 取扱説明書 [PDF:274KB] Toshiba X500 Personal Computer User Manual Installation manual & user guide (平成26年5月)(PDF:189KB) La garantie paratuberculose au cheptel Copyright © All rights reserved.