1. 21 A If ERROR is displayed during testing refer to the Trouble Shooting section for more information A Ifthe readings obtained on your ACE blood glucose meter does not confirm with your symptoms or the way you feel review proper testing procedure and repeat test with a new strip new pack of strips If the reading that appears still does not confirm with your symptoms seek your doctors advice When the Blood Glucose test is over 1 Ifyou wish to do another test insert a new strip into the monitor and press the NEXT Button The monitor restarts for you to do anothertest 2 The monitor automatically switches OFF after 1 minute after the test is over or after 10 seconds after the used strip is removed 3 To manually switch OFF your monitor press the POWER Button for 2 seconds A The results obtained are saved in memory and are not lost when the monitor is switched off automatically 22 12 Memory Function ACE Glucose Meter has a memory capacity to automatically store your last 75 Blood Glucose test results along with smarttags You can review these readings in order from the most recent reading to the oldest reading or vice versa The Smart tag Date and Time of the test result is also displayed enabling you to know when those readings were taken ACE also displays the average of the all Random values saved followed by the Before Meal Average and After Meal average of the values saved in its memory While calculatin
2. 4 NOW Wipe the test area with sterile dry cotton 5 Take your Auto Lancet Device and Comfylets lancet and follow instructions given in Section 10 to draw a sample of blood A If you are using any other lancet device or other method of obtaining blood follow manufacturers instruction for the same A Ensure puncture site is cleaned as indicated above Failure to clean puncture site as indicated above may result in wrong results 16 10 Obtaining a Blood sample for Glucose Testing 1 Unscrew the Auto Lancettip 2 Insert a new lancet firmly into the carrier and pinch the lancet to twist off the cover 3 Replace the threaded tip 4 The comfort tip offers five different levels of skin penetration Select best depth as follows 1 2 for soft or thin skin 3 for average skin thickness A 4 5forthick or calloused skin ge u 6 A To select a desired depth move the number to match the arrow For an even finer adjustment the arrow may be placedbetween any two numbers 17 5 Next hold the tip in one hand and pull on the sliding barrel with the other hand The device will be cocked when a click is felt as the ends are pulled apart Release the sleeve It will automatically move back to its original position near the trigger Button 6 Warm your fingers slightly to improve blood flow to your fingertips 7 Hold the loaded device against the side of your finger Next press the trigger and lift up the device
3. f aah 8 Set aside the Auto Lancet Wait for a few Lx seconds till a droplet of blood is formed Do not press hard or milk your fingers to draw the blood You may press your finger gently A For safety reasons and to prevent cross contamination discard the used lancet into an appropriate scrap or bio hazard container Never allow another person to use a lancetthathas already been used 18 11 Checking your Blood Glucose 1 Remove atest strip from its pack 2 Insert the strip into the ACE Blood Glucose Meter with the two electrodes pointing towards the monitor and facing upwards 3 Press the POWER Button to turn on the monitor It displays initial message followed by CODE currently seton the monitor wer PA A For best results the test strip must be used immediately after removing from its pack A Ensure that the calibration code displayed matches the calibration code of strips being used If not change the calibrationcode ofyour monitoras explained earlier 4 The monitor now displays the Blood Drop Symbol which indicates that it is ready to acceptthe blood sample 5 If instead of the test symbol ERROR is 19 DAY MONTH YEAR 6 displayed as shown here refer to the trouble shooting section for more information When the meter displays the blood drop symbol press the NEXT key to select the smart tag BEFORE MEAL or AFTER MEAL or none to tag your reading wi
4. other assistance please contact customer care 26 15 Specifications Product Application Size Weight Operating Conditions Battery Life Display Measuringrange Measuringtime Test strip Storage Memory Capacity ACE Blood Glucose Meter To determine blood glucose in whole blood by amperometricmethod 90 mm x 55 mm x 22 mm 72 grams including batteries Temperature 0 C to 40 C Humidity lt 98 Approx 20 000 minutes Large Display with 12 mm characters for results 20 mg dl to 600 mg dl 20 seconds Between 10 C to 30 C 75 Blood Glucose Test Results with Time Date and Smart Tag for Random or Before or After Meal It also displays average for each tag 27 16 Warranty Information This monitor is covered by a PRODUCT LIFE TIME WARRANTY against any defect due to defective materials or workmanship for a period ofthree years from the date of purchase LIFE TIME is defined as the period as long as the product is in production and 1 year afterthe production ofthe product has ceased If during this period the monitor does not work properly because ofa defect in material or workmanship Pulsatom Healthcare Pvt Ltd will repair the monitor or replace the monitor with another monitor or an equivalent product free of charge The Warranty of the repaired or replacement monitor will expire on the date of expiration of the original Warranty or ninety 90 days after shipment of a replacement system
5. time Even if the date and time are incorrect test results are not affected You can reset the date and time on your ACE Glucose Meter When you press the POWER Button the monitor switches ON and displays the initial screen in which all the segments of the display are shown Press the POWER button once again on your monitor when the initial display as shown in the picture is shown to enter the time and date setting mode Your monitor now displays the current time and date set on your monitor and the hour is blinking Press NEXT or POWER Button to increase or decrease the hour setting till it displays the desired hour value 10 AVG PAY MONTH YEAR y 8918 88 cone Qi 88 88 SHE ERROR BEFORE MEAL AFTER MEAL DAY MONTH YEAR eb ier te id 4 Wait for 2 seconds to save the hour setting Setia and to go to the minutes set mode The HEN minutes now Start to blink E 5 Press the NEXT or POWER Button to increase or decrease the minutes setting till it displays the desired minutes value 6 Waitfor 2 seconds to save the minutes setting Gate io and to go to the set day mode The day now 71 36 startsto blink 7 Press the NEXT or POWER Button to increase or decrease the day setting till it displays the desired date value 8 Wait for 2 seconds to save the day setting and Ati an to go to the set month mode The month now A startsto blink 9 Press the NEXT or POWER Button to incre
6. whichever period is longer This Warranty applies only to the original purchaser of the monitor who has registered with Pulsatom Healthcare Pvt Ltd as a user of this monitor by sending the customers registration card duly filled in Pulsatom Healthcare Pvt Ltd undertakes to repair or replace the instrument at its discretion subject to the following conditions 28 1 The purchase Memo Bill Invoice must be preserved and produced along with the defective unit 2 In an event of any complaint the unit must be returned to the nearestservice center or to us freight paid for examination 3 This Warranty is not valid for damages resulting from accident mishandling negligence improper repair tampering loss of components or accessories or if the instrument is not used according to the manual 4 The purchaser s exclusive remedy with respect to the ACE Blood Glucose meter shall be repair or replacement at the option of Pulsatom Healthcare Pvt Ltd 5 In no event shall Pulsatom Healthcare Pvt Ltd be liable to the purchaser or any other person for any direct incidental consequential special or punitive damages arising from or in any way connected with the purchaser or operation of the monitor or its 29 6 7 8 9 lt parts even if Pulsatom Healthcare Pvt Ltd has been advised of the possibility of such damages No Warranty of merchantability or fitness for a particular purpose if any is
7. ACE Accurate Compact amp Economical Blood Glucose Meter User Guide NOTICE A The essential features of the type described and illustrations herein remaining unaltered Pulsatom Healthcare Pvt Ltd reserves the right to carry out modifications at any moment on the monitor strips or any other accessories as may be convenient and necessary without being obliged to bring this booklet up to date The descriptions and illustrations in this booklet are not to be taken binding on the manufacturers A Any text that appears in bold italics and with these symbols is important information that should be read carefully and CONTENTS 1 Introduction 2 ACE Blood Glucose Meter 3 ACE Blood Glucose Test Strips 4 Batteries 5 Switching ON 6 Date and Time Settings 7 Coding your Meter before use 8 Supplies for Blood Glucose Testing 9 Preparingthe Puncture Site 10 Obtaining a Blood sample for Glucose Testing 11 Checking your Blood Glucose 12 Memory Function 13 Important Do s amp Don t s 14 Trouble Shooting 15 Specifications 16 Warranty Information 17 Service Instructions on oO A 13 15 16 17 19 23 25 26 27 28 31 1 Introduction ACE Blood Glucose Meter is the latest Glucometer coming from Pulsatom Healthcare Pvt Ltd manufacturers of India s first indigenous Blood Glucose Meter Please read this users manual thoroughly before you begin using the ACE Blood Glucose Meter as it provides all
8. ase or decrease the month setting till it displaysthe desired month value 11 10 Wait for 2 seconds to save the month setting ts and to go to the set year mode The year now Pr 3 starts to blink 11 Press the NEXT or POWER Button to increase or decrease the year setting till it displaysthe desired year value 12 Wait for 2 seconds to save the year setting and returnto using yourACE Glucose Meter A The displayed Date amp Time is saved and your monitor automaticallyexits the time setting mode 12 7 Coding your Meter Before you use your ACE Glucose Meter for the first time and thereafter every time you open a new box of test strips you need to setthe Ace Glucose Meter to match the strip being used This is called Coding ofthe monitor A Incorrectly coded monitors will give false results Coding needs to be done every time you use a different or new pack of strips 1 Code of the ACE Gm3 Blood Glucose Test strips can be found printed on the vial of strips as shown in the figure For example let us code your monitor to use a packet of strips with Code C11 2 When your press the POWER Button the ae meter switches ON and displays initial screen eb ie ie in which all the segment s of the display are CODE 11 36 shown Then the code number currently set i h on your ACE monitor is displayed identified by the CODE indicator on the display 13 3 Press both the b
9. displays the battery low symbol as shown in in ES the figure lt also displays for 2 seconds the approximate tests left before complete p C failure 3 The approximate life left when the power level displayed along with battery low symbol is as follows P3 180 minutes or 100 tests P2 120 minutes or 50 tests P1 60 minutes or 25 tests A Your monitor comes with a Product Lifetime Warranty when the Battery Low symbol is displayed you can get a FREE replacement from the company or your nearest support center Please see warranty section for details 5 Switching ON 1 When you press the POWER Button the monitor switches ON and displays the initial screen in which all the segments of the display areshown 2 It next displays the current Code set on your Ace Blood Glucose Meter This is indicated by thetag CODE displayedon the monitor 3 It then displays the blood drop symbol indicating it is ready to accept a sample for a test 5 Ifno sample is applied within 60 seconds the monitor switches OFF automatically 6 Press the POWER Button for 2 seconds to manually switch OFF the monitor 9 AVG PAY MONTH YEAR 88 18 88 HOUR MIN CODE E 88 88 Doo OOo g dl mmol L mg dl ERROR BEFORE MEAL AFTER MEAL DAY MONTH YEAR Be 1i coE 11 36 un L th 65 12 12 6 Date and Time Settings 1 2 3 Your ACE Blood Glucose Meter is preset with IST date and
10. g the average it ignores all results under 20 mg dl and above 600mg dl A Ifthe memory is full with 75 glucose results and a new result is added then the oldest result is automatically deleted A Ifthere is no Button input for 4 seconds the program automatically exits the memory mode and returns to test mode 23 Reviewing Average of Stored Values 1 When in the test mode press the POWER Button once till AVG symbol is displayed to review the average memory values 2 The monitor shows your average readings with Smart tags 3 Pressthe NEXT or POWER Button to review other averages sequentially Reviewing Stored Values 1 Inthe test mode press the POWER Button till the MEM symbol is displayed on the monitor to begin using the memory function 2 The meter shows your latest reading with Smart tag Press the NEXT or POWER Button to review stored values sequentially 3 Continue to press NEXT or POWER Button continuously to scroll through all memory values with their Smart tags 24 BEFORE MEAL MEM gt L DAY MONTH YEAR Tbes de HOUR MIN 11 35 Cc l mg dl BEFORE MEAL 13 Important Do s amp Don t s 1 Use strips before the expiry date marked on the test strip pack 2 Storethe stripsin a cool and dry place below 30 C 3 DO NOT use strips which have incorrectly stored or have been left open for a long time Remove the strip at the time of testing only 4 Ensure that C
11. implied from the sale of the monitor shall extend for longer duration than product lifetime as defined earlier While the company will make every effort to repair or replace the unit under this Warranty as soon as possible it is expressly made clear that the company shall not be liable to do so within any specified time or period All warranties covering ACE blood glucose monitoring systems are valid only when ACE is used with ACE GM3 Blood Glucose Strips All warranties covering the ACE meter are voided by use of any other strips otherthan ACE GM3 Strips Claims if any to this Warranty shall be made only before the courts having jurisdiction in Bengaluru 30 17 Service Instructions Customers experiencing difficulties should review the troubleshooting guide of their user manual For your service requirements and any other enquires please contact us You can contact us by any ofthe following means Online http www pulsatom com E mail info pulsatom com Tel 91 80 2357 9166 91 990 003 1600 Mail to Pulsatom Healthcare Pvt Ltd 86D2 A Industrial Suburb Yeshwanthpur Bengaluru 560 022 Karnataka INDIA 31 lala Healthcare Pvt Ltd 86D2 A Industrial Suburb Yeshwanthpur Bengaluru 560 022 INDIA Tel 91 80 23579166 Fax 91 80 23579170 Email info pulsatom com Web www pulsatom com
12. ode on the meter matches the code on the strips pack 5 Ensure that your hands are clean at the time of obtaining a sample 6 Ifusing spiritor alcohol swab before pricking your finger wait for 3 4 minutes for the finger to dry completely before pricking 7 Use only freshly obtained capillary or venous blood for testing DO NOT use stored blood fortesting 8 Avery small drop of blood is reguired for the test Do not flood the test strip with excessive blood Gently touch the drop of blood to the test area and the blood will fill up the test area by itself 9 Care should be taken to avoid extremes in temperature variations humidity shock dust and exposure to direct sunlight A Your ACE Monitor is an invaluable tool to monitor your Diabetes Ensure that you handle the meterwith care 25 14 Trouble Shooting 1 Displays ERROR Remove and reinserttest strip Ifthe problem persists repeat test with a new test strip Ensure sample is applied after apply sample symbol is displayed 2 In case of Incorrect Blood Glucose Values Check Was the correct code set on the monitor Was the strip used before its expiry date Was the strip stored under 30 C in a cool and dry place Was the puncture site cleaned amp dried well before the test Was alcohol or spirit used to clean the puncture site If yes did you wait for 3 4 minutes for it to dry Did you apply too less or excess quantity of blood sample A Forany
13. th yourtesting status With the strip inserted in the ACE Glucose Meter apply the drop of blood to the test area You may lift the monitor in your hand and move itto come in contactwith the blood drop The blood droplet automatically fills up the test area Remove your finger as soon as you see blood flowing into the test area A very small droplet of blood approx 211 is required forthetest 7 As soon as the sample is applied the 20 DAY MONTH YEAR Bid ig HOUR MIN 11 36 ERROR DAY MONTH YEAR ebd BEFORE MEAL machine begins a countdown of 20 seconds and displays the time remaining for test to complete as 20 19 18 17 a 9 Atthe end of 20 seconds your blood glucose value is displayed in mg dl units on the ACE monitor This is also saved in the memory along with the time and date of the test 10 If the blood glucose result is higher than 26 12 10 600mg dl Hi is displayed and if the blood 11 36 glucose result is lesser than 20mg al Lo is I I Cc displayed L l mg dl BEFORE MEAL A ACE can store the last 75 test results in its memory fo maintain a permanentlog record the glucose values in your health log 11 Remove the test strip from the meter and discard it safely Unscrew the Auto Lancet tip Carefully stick the protective disk cover back on the used lancet Grip the holder firmly and pull the lancet safely out of the holder Dispose the lancet safely
14. the information you need to use it correctly It consists of ACE Blood Glucose Meter ACE Compatible Gm3 Test Strips Lancing Device Lancets Carry case User Manual This is a comprehensive list of items that form a part of the ACE Blood Glucose Meter Kit Actual contents of the package purchased by you may vary according to the package 2 Know your ACE Blood Glucose Meter Strip Slot Display Increase Button Front View ACE Blood Glucose Meter Memory Symbol DAY MONTH YEAR Date Code Symbol Error Symbol Low Battery AVG 88 18 85 eu HOUR MEN Mme cone Y sg Apply Sample HIN Symbol ar Result Code 2 meta Units mg dl ERROR BEFORE MEAL Smart Tags Symbol TTS AFTER MEAL Display Panel ACE Blood Glucose Meter 3 ACE Blood Glucose Test Strips Ei 22 O Strips for Ace Blood Glucose Meter and GM3 Blood Glucose meter are compatible for each other 1 Contact Area Indicated by the arrow mark Insert this end of the test strip into the ACE Blood Glucose Meter with the arrow facing upwards and towards the monitor 2 Test Area Blood Sample is applied to this area ofthis test strip for testing 4 Batteries Your monitor comes with batteries pre installed There is no need to install batteries prior to use Just press the power button and the ACE Glucometer is ready to test 1 When batteries become weak the monitor DAY MONTH YEAR
15. uttons on your meter CODE simultaneously to change the calibration code The CODE symbol begins to blink i C3 4 Now press the NEXT or POWER Button to DAY MONTH YEAR increase or decrease the code setting till it 26 12 12 displays the desired code For example C11 CODE Pee 35 to use a pack of strips with code C11 m _ 11 5 DO NOT press any key for 2 seconds and the code will be saved and the monitor will return tothe operational mode A Ifno Button is pressed for 2 seconds the displayed code is saved and your monitor automatically exits the code setting mode 14 8 Supplies for Blood Glucose Testing Gather all your testing supplies before you begin to test You will need the following items 1 ACE Blood Glucose Monitor 2 ACE Gm3 Blood Glucose Test Strips 3 Comfylets Lancets Super Fine Lancets to ensure easy flow of blood with maximum comfort 4 Safecare Lancing Device To help you prick your fingerfor a blood sample with ease 5 Sterile Cotton Swab A Items packed with your Kit is marked on your ACE Blood Glucose Meter Carton Box Package contents vary according to the package purchased 15 9 Preparing the Puncture Site 1 Wash your hands with soap and water Wipe dry 2 If you use an alcohol wipe or medicated spirit E to clean the puncture site ensure that you let your finger dry completely before testing AI 3 Wait for at least for 3 to 4 minutes before PA testing a