Home

Model #: SU7500RT3U - Digi-Key

image

Contents

1. e Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection Common applications include any mix of servers workstations hubs routers concentrators IP telephony and traditional PBX switching systems Package Includes e 3U power module with detachable hot swap PDU input output panel and bypass switch e 3U external battery pack e Two sets of 4 post rackmount rails one for each of the 3U components e One set of tower stands for upright tower configuration e PowerAlert software complete data cabling user manual with warranty information Features e 7 500 VA 7 5kVA on line double conversion UPS system High voltage input High voltage output e Detachable input output PDU module with manual bypass switch enables hot swap UPS replacement without powering off connected equipment e Installs in only 6 rack spaces 3U power module 3U battery pack with a maximum installed depth of 32 5 inches e Offers 9 min runtime at full load 7500VA 6000W and 20 min at half load 3750VA 3000W Runtime is expandable with any number of optional BP240V10RT3U external battery packs e Full time sine wave 200 208 220 230 or 240V 2 output user selectable e Actively converts raw incoming AC power to DC then re converts output back to completely regulated filtered AC output e Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V e S
2. 5 x 23 Shipping Dimensions HWD cm Unit weight Ibs Unit weight kg Material of construction Form factors supported ENVIRONMENTAL Relative Humidity Line mode BTU hr Max COMMUNICATIONS WatchDog compatibility Network monitoring port EPO port SNMP compatibility Software and cabling included 101 x 80 x 58 4 Power Module 55 Ibs Battery Pack 136 5 Ibs Power Module 25 kg Battery Pack 62 kg Steel Rack 6U 0 to 95 non condensing 2025 btu hr 91 efficiency line mode Yes compatible with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipment ideal for unattended kiosk applications Includes 2 built in DB9 monitoring ports 1 RS232 1 contact closure Includes dedicated EPO emergency power off interface and cabling Built in accessory slot accommodates internal SNMP Web card and other network accessories Includes PowerAlert UPS monitoring software for all common network and standalone operating systems Cabling included LINE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES Appearance Cold Start CERTIFICATIONS Certifications WARRANTY Product Warranty Period U S Canada amp Puerto Rico Connected Equipment Insurance U S
3. Canada amp Puerto Rico Optional Coverage Zero online UPS continuously converts incoming AC to DC then back to AC When line power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 156VAC Below this point output is maintained utilizing battery reserves Maintains continuous operation during overvoltages to 276V AC Above this point output is maintained utilizing battery reserves Attractive all black color scheme Yes inverter can be cold started to enable temporary AC output during a power failure Tested to UL1778 USA CSA C22 2 No 107 3 Canada CE European Union NOM Mexico Class A Emissions 2 year limited warranty 250 000 Ultimate Lifetime Insurance 3 year 5 year next day and on site warranty coverage available for select opportunities contact Tripp Lite More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 3207 Copyright 2011 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
4. 30 240 compatibility VAC OUTPUT Frequency 50 60 Hz compatibility Output VA 7500 Output watts 6000 Output nominal 208V AC 200 208 220 230 240V voltage Output voltage Maintains pure sine wave output at all times regulated within 2 of selected nominal output voltage less than 3 regulation total harmonic distortion when used with computer loads Output frequency Regulates line frequency to 50 60Hz 0 05Hz regulation Outlet quantity type 4 x NEMA L6 20R 2 x NEMA L6 30R INPUT Maximum Input 200V 35A 208V 33 7A 220V 31 8A 230V 30 4A 240vV 29 2A Amps A Input connection Hardwire type BATTERY Expandable battery runtime DC system voltage VDC Battery Access Full load runtime Half load runtime Battery Pack Accessory optional Connects to UPS via Typical battery lifespan Battery recharge rate Runtime is expandable with optional BP240V10RT3U and BP240V32 external battery packs 240 User replaceable hot swappable external battery pack 9 min 7500VA 6000W 20 min 3750VA 3000W BP240V10RT3U BP240V32 Included 3 wire DC cable 4 6 years Less than 8 hours to 90 included battery set only VOLTAGE REGULATION Voltage regulation description Overvoltage correction Brownout correction On line double conversion process give this UPS the ability to maintain output voltage within 2 of selected nominal voltage at all times Maintains continuous operation
5. Tripp Lite M 1111 West 35th Street z Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SU7500RT3U SmartOnline Expandable Rack Tower UPS System On line double conversion protection for mission critical applications Highlights e 7500VA on line 6U rack tower UPS with expandable runtime 3U power module 3U battery pack e Detachable PDU with manual bypass switch enables hot swap UPS replacement without powering off connected loads e 200 208 230 240V selectable input output voltage e 2 output voltage regulation over an input voltage range of 156V to 276V e Enhanced serial communications ports SNMP Web Card Slot and EPO interfaces e 250 000 Ultimate LIfetime Insurance USA amp Canada only Description 7 500 VA 7 5kVA on line double conversion UPS system for critical server network and telecommunications equipment Installs in only 6 rack spaces 3U power module and 3U battery pack Maximum installed rack depth of 32 5 in Expandable battery runtime with optional BP240V10RT3U and BP240V32 external battery packs Full time sine wave 200 208 220 230 or 240V 2 output Actively converts raw incoming AC power to DC then re converts output back to completely regulated filtered AC output Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V Standard 3 wire 208V hardwire input connection NEMA L6 30R and L6 20R output r
6. eceptacles Detachable input output PDU module with manual bypass switch enables hot swap UPS replacement without disrupting power to connected equipment Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support communications via RS 232 contact closure port and optional SNMPWEBCARD slot Supports detailed monitoring of equipment load levels self test data and utility power conditions via network interfaces Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Front panel LEDs offer at a glance confirmation of line power status battery power status AC to DC conversion DC to AC conversion bypass mode and output power status LCD panel with scroll buttons offers detailed diagnostic test information at startup and during self tests plus real time data on input and output voltage frequency Hz load percentage and battery charge level LED LCD display panel easily rotates for viewing in rackmount or tower configurations Audible alarm Self test Fault tolerant auto bypass mode 4 post rackmount accessories and 2 9USTAND tower kit included 2POSTRMKITWM 2 post rackmount hardware accessories available Field replaceable hot swappable power module and external battery packs Attractive all black color scheme 2 year warranty and 250 000 connected equipment insurance extended warranty and service contracts available Applications
7. tandard 3 wire 208V hardwire input connection e 2 x NEMA L6 30R and 4 x L6 20R output receptacles e Detailed LCD panel with scroll buttons offers detailed diagnostic test information on startup and during self tests plus real time data on input and output voltage frequency Hz load percentage battery charge level and more e Network grade AC surge and noise suppression e Zero transfer time between AC and battery operation e Network management interfaces support communications via RS 232 contact closure port and optional SNMPWEBCARD slot e Supports detailed monitoring of equipment load levels self test data and mains power conditions via network interfaces Includes PowerAlert monitoring software and complete cabling e Emergency Power Off EPO interface e Front panel LEDs offer at a glance confirmation of line power status battery power status AC to DC amp DC to AC conversion bypass mode and output power status e Fault tolerant auto bypass mode prevents loss of output during UPS fault conditions or excessive UPS loading e 4 post rackmount and upright tower installation accessories included 2POSTRMKITWM two post rackmount hardware accessories available e Field replaceable hot swappable power module and external battery packs e Attractive all black color scheme e 2 year warranty 250 000 connected equipment insurance e Extended warranty and service contracts available Specifications SYSTEM OVERVIEW Voltage 200 208 220 2
8. without using battery power during overvoltages to 276V AC regulating output within 2 of selected nominal Maintains continuous operation without using battery power during brownout undervoltage conditions to 156V AC regulating output within 2 of selected nominal LEDS ALARMS amp SWITCHES Alarms Switches Front panel LEDs Multi function audible alarm offers notification of UPS start backup operation low battery overload UPS fault inverter fault DC bus fault overtemperature remote shutdown shutdown imminent and shutdown complete Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions 6 LED DISPLAY line power bypass inverter charger output AC and battery operation LED LCD display panel easily rotates for viewing in rackmount or tower configurations SURGE NOISE SUPPRESSION EMI RFI AC noise suppression AC suppression response time PHYSICAL Shipping weight Ibs Shipping weight kg Cooling method Unit Dimensions HWD in Unit Dimensions HWD cm Shipping Dimensions HWD in Yes Instantaneous 331 150 3 Fan Power Module 5 14 x 17 5 x 25 Battery Pack 5 16 x 17 5 x 25 Installed depth of power module extends to 32 5 inches once detachable PDU backplate is installed Power Module 13 3 x 44 4 x 63 5 Battery Pack 13 4 x 40 6 x 63 5 Installed depth of power module extends to 82 6 cm once detachable PDU backplate is installed 39 75 x 31

Download Pdf Manuals

image

Related Search

Model models model mayhem model 3 model y tesla model number of this laptop modelo beer model context protocol model homes near me modelscope modelsim modeling 3d model y 2025 model s plaid model o software modelo negra model cars modelling model trains model resume model number for my pc modelo especial model risk models resource model name of my laptop model roundup