1. SIRIO PLUS Lung ventilator for emergency transport and intensive care code 09439 rev 9 1 01 06 2012 Dimensions W x H x D 360 x 250 x 220mm with handle Weight 6 5 Kg without accessories Relative humidity use 30 95 RH Temperature From 10 to 40 C Protection level IP 54 Air navigability According to UNI EN 794 3 Automatic compensation of atmospheric pressure on measured pressure Present max 5000 mt TECHNICAL DETAILS Functioning principles Time cycled and constant volume Pressure cycled Microprocessor controlled flow Spontaneous breathing with integrated valve Ventilation modes IPPV IPPV AST SIMV CPAP PSV PCV APNOEA Back Up manual breathing CPR mode Pressure limited ventilation and non constant volume the airways pressure is limited but the volume is delivered during all the inspiration time Sirio PLUS_te_rev9 1 Breathing frequency From 5 to 140 bpm SIMV Breathing frequency From 0 to 139 bpm Tidal volume From 0 05 to 2 0 L min I E ratio From 1 4 to 3 1 Inspiratory pause From 0 to 50 of the inspiratory time Inspiratory pressure limit From 2 to 80 cmH20 PEEP From 0 to 20 cmH20 Minute volume with 1 2 I E ratio From 1 to 25 L min O2 concentration Settings from 21 to 99 with O2 only source from 50 to 99 Trigger sensibility Adjustable from off 1 to 9 cmH2O
2. under set PEEP level Max inspiratory flow About 90 L min Flow measuration range From 1 to 120 L min Pneumatic supply O2 and Air pressure included between 280 kPa and 600 kPa 2 8 6 bar Patient circuit Non Rebreathing Flow sensor By magnetic disturbance sterilizable for several uses Atmospheric compensation Automatic GAS CONSUMPTION Control About 1 L min er Volume with 50 O2 40 of the minute volume set mixer Minute Volume without air mixer 100 of the minute volume set MONITORING The measured parameters are Flow Max Pressure Mean PEEP Insp Time Exp Time displayed on back illuminated LCD Breathing Frequency Exp Minute Volume Exp Tidal monitor and divided into 4 pages Volume Sirio PLUS_te_rev9 1 2 4 ALARMS Low gas supply The alarm occurs when the supply gas pressure is under 2 bar High PAW The alarm occurs when the pressure limit set is joined the inspiratory flow is interrupted Low PAW The alarm occurs if the low limit is not joined High Low expired Tidal Volume The alarm occurs if the expired volume is higher lower than the set one High Low expired Minute Volume The alarm occurs if the expired volume is higher lower than the set one Apnoea The alarm occurs in absence of breathing activity the Apnoea back up safety system intervenes High Low frequency The alarm occurs if the measured frequency is higher lower than the set
3. one Power failure Electric power failure alarm Low battery The alarm occurs if the battery voltage is lower than 10 5Vdc POWER SUPPLY Electric power From 11 to 14 Vdc when supplied with a vehicle source or 230Vac if used with the supplied feeder Power 40 W 230Vac with the supplied feeder Internal electric power 12Vdc battery Autonomy 3 hours max 9 hours with the optional Long Life Pack module Charging time About 10 hours CONFORMITY TO NORMS IEC 601 1 IEC 601 1 2 IEC 601 1 4 EN 1281 1 EN 794 3 UNI EN 475 UNI EN 4135 DIR 93 42 EEC Class and type according to IEC Class 1 Type B 601 1 Class according to 93 42 EEC Class IIb Directive Sirio PLUS_te_rev9 1 3 4 ACCESSORIES Supplied Accessories e O2 tube AIR tube e Feeder 100 240Vac 50 60Hz 13 8Vdc e Power cable e Power supply cable 12 Vdc e Disposable coaxial patient circuit e User s manual Optional Accessories See on Export Price List SIARE applies the EN ISO 13485 2004 Quality System and the 93 42 EEC Medical Devices Directive SIARE ENGINEERING INTERNATIONAL GROUP s r l Via Pastore 18 40056 Crespellano Bologna ITALY Tel 39 051 969802 Fax 39 969366 Email mail siare it http www siare it Sirio PLUS_te_rev9 1 4 4

Download Pdf Manuals

image

Related Search

Related Contents

基準表(PDF形式:67KB)  取扱説明書 保証書付  User`s Manual  Handleiding - Wehkamp.nl    mode d`emploi - Labo  Philips PT710  Hama 00106668 mobile headset  Philips HR1774 Blender    

Copyright © All rights reserved.
Failed to retrieve file