Home

KoiAir™ Product Manual

image

Contents

1. Always use parts that are supplied or approved by Airmax Use of other parts may result in poor performance and could create a hazardous situation Always unplug the system from the outlet and refer servicing to a qualified electrician under the following conditions 1 When the power cord is damaged or frayed 2 If the compressor is producing unusual noises or odors Your KoiAir compressor will need a maintenance kit KoiAir KA20 Item 510145 KoiAir KA40 Item 510146 every 12 36 months depending on operating depth air quality and operating temperature If your compressor is operating but there is no air coming out of the diffusers you will generally find that it is time to replace your diaphragm No maintenance required Replace membrane sticks 510168 if visibly damaged or if system has poor performance Unscrew the cover on the back of the compressor to expose the air filter Remove the air filter and brush away any dust particles Air filter should be replaced every 6 months KoiAir 1 510153 KoiAir 2 510149 The KoiAir Aeration Kit comes with a 3 Year Limited Warranty This limited warranty is extended exclusively to the original purchaser and begins from the date of original purchase receipt Membrane sticks airline and diaphragms are considered wear items and are not covered by this warranty Abuse or misuse of this product voids all warranty Any sign of water damage inside the unit voids all warra
2. Adjust three way air manifold to balance airflow between diffusers if desired It is not necessary to have even airflow between diffusers nor will equally throughout the water garden Do it have any effect on the life expectancy of the compressor Valve positions not exceed the max depth rating of 4 when are as follows placing your diffusers Depths in excess of fae this rating will greatly reduce airflow to the diffuser and cause excess strain on the i compressor reducing its life expectancy In case of extreme temperatures hot or cold j it is recommended to relocate plates from Q the deepest points of your pond O High Efficiency Compressor Control Valve O EasySet Weighted Airline KoiAir Weighted Diffuser O Spring Clamps Step 3 Place Your Diffuser s Find a location in your water garden to place the diffuser If you have two diffusers distribute them c A Valve Pointing Down Air Flow comes up from bottom and goes left B Valve Pointing Between Bottom and Right Air Flow comes up from bottom and goes left and right C Valve Pointing Right Air Flow comes up from bottom and goes right
3. es sor and that there is plenty of ventilation 2 Step 2 Connect The Airline Single Diffuser Systems Connect the weighted airline to the outlet on the compressor using the 214 rubber connector and included spring clamps Connect the other end of the airline to the diffuser No clamp is needed on the diffuser end Multiple Diffuser Systems Connect the included 214 rubber connector to the compressor and use one of the clamps to keep it in place Connect the bottom of the three way air manifold to the rubber connector and clamp it in place Next using the weighted airline measure the distance from the compressor to the approximate location of your diffuser Ensure to add a few feet to compensate for the depth of the pond Cut the weighted airline to the appropriate lengths and connect them to the three way air manifold as well as the diffusers No clamps are needed for airline GETTING TO KNOW YOUR KoiAir AERATION SYSTEM KoiAir 2 shown above KoiAir 1 KoiAir 2 for ponds up to 8 000 gallons for ponds 8 000 16 000 gallons KA20 KA40 17 Watts 115 Volts 35 Watts 115 Volts Includes control valve N A to balance airflow between both diffusers Includes 25 of Includes 50 of weighted airline weighted airline 2 1 KoiAir Diffuser KoiAir Diffusers 4 Max Depth 4 Max Depth 2 Spring Clamps 2 Spring Clamps Step 4 Adjust Your Valves Systems with Multiple Diffusers Only
4. nty For warranty claims product must be returned to the original place of purchase with original receipt Airmax Inc Natural Clear Water Guaranteed WWwW airmaxeco com 014_13 Important Information Winter Operations Getting to Know Your KoiAir Aeration Kit Installing Your KoiAir Aeration Kit 2 Maintenance Safety 2 Regular Maintenance 3 Warranty Information IMPORTANT INFORMATION Never connect to an extension cord This may result in equipment failure e Do not allow anything to rest on the power cord e Do not place the unit where people may step on the power cord e Never override electrical or mechanical interlock devices e Never attempt maintenance functions that are not specified in the user manual Never operate the system if unusual noises or odors are detected Disconnect the power cord from the outlet and call for service A DANGER A e Read the operating instructions carefully To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle e THIS UNIT IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER e This unit has not been investigated for use in swimming pool areas e Disconnect unit from power source before handling e Repair and exchange of cable must be carried through by the supplier manufacturer WINTER OPERATION A DANGER A Operating in freezing condition
5. s on an ice covered water garden will cause open water areas even in freezing conditions Also the ice thickness around these open areas will be much thinner than the ice over the remainder of the pond Injury or fatality may result from falling through the ice Airmax strongly recommends that this danger of thin ice around the diffuser site be clearly posted at frequent intervals Owner assumes all responsibility for operating KoiAir Aeration Kit during winter months If you choose to turn off your system for the winter do the following e Unplug the system and remove the diffuser s airline s and compressor e Store in a dry area protected from the elements such as a garage or basement climate control recommended INSTALLING YOUR KoiAir AERATION SYSTEM Step 1 Decide on a Location Decide on a location for the compressor It s important to elevate the compressor a few inches above ground level making sure the compressor is above the pond s water surface If power is not available at the pond s edge the compressor may be located at the power source and extra airline can be added up to 100 to reach your desired diffuser location NOTE It is recommended that the compressor be covered and not exposed directly to the elements This can be accomplished by purchasing a small TrueRock cover Item 510330 If you decide to use your own cover make sure it will keep water from coming in direct contact with the compr

Download Pdf Manuals

image

Related Search

Related Contents

Graphic Data Manager RSG40 Memograph M  Fagor FQ-8925X  Video/Display Problems - Service & Support  Perle Systems DS1 Network Card User Manual  Toshiba 1TB STOR.E TV+  OS-C160 - 防犯カメラ、監視カメラ  

Copyright © All rights reserved.
Failed to retrieve file