Contents
1. Type Target Target Target Target 3 InstrumentModel GER 1500 GER 1500 GER 1500 GER 1500 4 InstrumentManufacturer Spectra Vista Corporation Spectra Spectra Spectra 5 InstrumentSerialNumber 2039 2039 2039 2039 P 6 DateTime 11 Jun 2010 12 52 34 11 Jun 11 Jun 11 Jun 7 DateTimeSource Unknown Unknown Unknown Unknown 8 MemorySlot 2 4 6 8 9 Averaging 16 16 16 16 10 IntegrationTime 40 40 160 160 11 IntegrationTimeUnits ms ms ms ms 12 ForeOptic Standard 4 field of view Standard Standard Standard 13 Comments r g i P 14 y 15 Ia y re Figure 3 Use the headers function to combine all headers into a single table 3 2 3 Comma separated lists A specific field of a structure array can be accessed as a comma separated list For example if s is a structure array of spectra typing s name produces a comma separated list of the names of all the spectra ans gr061110_000_reference ans gr061110_001_reference Comma separated lists can easily be assigned to variables To store the above list in a variable called allnames type allnames s name The curly brackets in concatenate the list into a cell array Using comma separated lists provides a way to rearrange imported data in any format or structure that may be required It is particularly useful when dealing with a
2. 11 Jun 2010 12 52 44 11 Jun 2010 12 53 39 11 Jun 2010 12 53 56 127 11 Jun 2010 12 54 56 11 Jun 2010 12 55 08 10 11 Jun 2010 12 55 33 Intensity a u 200 300 400 500 600 700 800 900 1000 1100 Wavelength nm Figure 5 Plot of seven target spectra from a SVC GER 1500 spectroradiometer plot s wavelength s data This plots the data values vertically against their corresponding wavelengths To plot a structure array of multiple spectra type plot s wavelength s data The square bracekts in this expression concatenate the wavelength and data fields into two separate matricies To plot an individual spectrum say the sixth from a structure array s type plot s 6 wavelength s 6 data To plot a range of spectra say the fourth to the sixth inclusive type plot s 4 6 wavelength s 4 6 data When plotting reflectance data it may be preferable to multiply the data values by 100 to produce a reflectance plot in per cent plot s wavelength 100 s data ylabel Reflectance The wavelength values are usually in nanometres nm To produce a plot in micrometres um type plot 0 001 s wavelength s data A legend can be added to the graph using MATLAB s legend function For example to add a legend showing the name of each spectrum type legend s name Axis labels ranges and titles can be added using MATLAB s bu
3. a selection of useful utilities and tools for the handling and processing of field spectra We welcome all contributions whether based around MATLAB or other platforms Please contat us if you have any questions or would like to contribute a resource 1 2 Further information An overview of field spectroscopy can be found in the recent review article by Milton 1 A broad list of references is available from the Field Spectroscopy Facility s web site A description of MATLAB is available from The MathWorks 2 Installing the toolbox This section describes how to install the toolbox on a system running MATLAB 2 1 Check requirements The toolbox requires MATLAB 7 8 R2009a or later although some functions may work with earlier versions The Savitzky Golay smooth function sgsmooth additionally re quires the Signal Processing Toolbox For handling files from Analytical Spectral Devices ASD instruments ViewSpec Pro is recommended to convert ASD s binary format to the more easily readible text format Calculation of absolute reflectance requires calibration data for the reference panel which was used in the field Calculation of radiometric spectra radiance or irradiance requires calibration data for the specific instrument and configuration which was used Calibration data for the Field Spectroscopy Facility s reference panels and instruments is available Convolution of field spectra to the spectral respo
4. be opened from the FILE menu as shown in Figure 1 Click Add folder then locate the FSFPostProcessing1 3 6 folder In order to have MATLAB remember this new path click SAVE before closing the SET PATH tool Once the toolbox is added to the search path the toolbox documentation will appear in the HELP BROWSER under FSF Post Processing Toolbox as shown in Figure 1 Further infor mation about MATLAB s file locations and the search path is available in the MATLAB documentation 3 Importing examining and plotting Once installed spectra acquired on field portable spectroradiometers can easily be imported from the data file into the workspace This section describes how to import the files and how to examine and plot the data in the MATLAB environment Reliable metadata is critical for field spectroscopy All instrument data files contain im portant information in the file s header This includes details such as the date and time the spectrum was recorded the location it was recorded for instruments with GPS and the instrument settings The toolbox imports this information into a MATLAB structure along with the data itself A few example data files are provided with the toolbox to test these functions These can be found in the examples folder which is located within the folder where the toolbox was installed FSFPostProcessing1 3 0 examples 2012 07 18 3 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING 3 1 Importin
5. be paired by creating a logsheet file tar ref importsvc filename where filename is the name of the file to be imported Multiple files can be imported at once using wildcards For example if the current directory contains several SVC text files with the sig extension they can be imported by typing tar ref importsvc sig The imported spectrum or spectra will be stored in two separate structure arrays in the workspace one of target spectra tar and one of reference spectra ref If output is not suppressed with a terminal semi colon the structures will be shown tar 1x7 struct array with fields name datetime header pair wavelength data ref 1x7 struct array with fields name datetime header wavelength data Note that the structure array of reference spectra ref may contain duplicates This is because signature files always contain the previously recorded reference spectrum for each target spectrum Additionally the structure array of target spectra tar contains a field called pair The value of the pair field gives the name of its corresponding reference spec trum This pairing information which matches target spectra to their reference spectra is required for calculating reflectance 2012 07 18 5 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING When importing spectra from SVC instrument models with multiple detectors such as the HR 1024 there may be overlapped data in the spectra T
6. into two broad classes multispectral imagers and imaging spectrometers The convolution process is different for the two instrument types and will be described in separate subsections 6 2 Multispectral instruments The spectral response function of an instrument describes the spectrum produced by the detector in response to a purely monochromatic light source at a wavelength Asource 7 Multispectral sensors make measurements of light intensity in a number different bands The spectral response function of each band therefore describes the response of the band s detector to monochromatic light at wavelength Agource For an instrument with N bands the response of band n to a monochromatic light source at wavelength Asource is given by a function fn Asource AS each band has its own spectral response function there will be a set of such functions Fi Aasieoa f2lAsource oes N Asource In general it is not important to know the absolute spectral response of an instrument and the relative spectral response is sufficient The functions are therefore normalized to unit area f fn d 1 for all n 0 If the source spectrum Syource A were known which it generally isn t the total response in band n could be found by integrating the product of the source spectrum and the spectral response function over the full range of wavelengths A Sn Ssource A fn A da Often it is required to calculate the relative band respons
7. large number of spectra as described in the following subsections Further information about and examples of comma separated lists are available in the MATLAB documentation 3 2 4 Creating a table of header information When a large number of spectra have been imported it may be convenient to summarize all header information in a single table as shown in Figure 3 The headers function provides a convenient way to produce a cell array containg the values of all the header fields To create a cell array of header information H from a structure array s type 2012 07 18 8 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING AAA S File Edit View Graphics Debug Desktop Window Help F AAA gt Novalid plots for s 1 S lt 256x8 double gt EE 2 3 4 5 287 8500 1 4200 1 3900 0 1100 0 1100 T 291 5600 5 5800 5 6600 2 4300 2 3700 295 2500 7 4500 7 6700 3 2700 3 1900 298 9200 amp 9 6100 9 3600 4 1100 4 0200 302 5700 21 0400 21 0400 9 3000 9 0300 306 2100 36 5500 35 6500 15 9100 15 8000 309 8200 49 9100 51 8100 22 7400 22 1100 313 4100 69 1200 69 1200 31 3200 30 8900 r a 932 1200 R7 7700 40 3600 3R 7400 SON Dw Biwi 4 gt Figure 4 Data can be copied into a single matrix if required H headers s This table can then be viewed variable editor by typing openvar H or selecting the variable H in the WORKSPACE BROWSER The header information is pre sented in columns with the first colum
8. limited import functionality in basic mode This warning may be safely ignored The panel calibration spectrum can be plotted by typing plot p wavelength 100 p data xlabel Wavelength nm ylabel Panel reflectance 2012 07 18 14 version 1 3 6 4 PROCESSING FUNCTIONS 1 Panel calibration file for FSF Post Processing Toolbox 2 Name SRT 011 3 Date and time of calibration 2011 05 26 10 00 4 350 0 980 5 351 0 980 6 352 0 981 7 353 0 981 8 354 0 981 9 355 0 981 10 356 0 981 11 357 0 981 12 358 0 981 13 359 0 982 14 360 0 982 15 361 0 982 16 362 0 982 17 363 0 982 18 364 0 982 19 365 0 982 Line 3 Column 41 Plain Text v Tab Size 3 Figure 7 A example of a CSV file containing a reference panel calibration spectrum A copy of this file can be found in the examples folder It can be imported into MATLAB with the importpanelcal function The data consist of wavelengths in nm and the corresponding panel reflectance as a number in the range 0 1 2012 07 18 15 version 1 3 6 4 PROCESSING FUNCTIONS The reflectance values were multiplied by 100 to convert them to per cent A structure array of absolute reflectance spectra can be calculated from a structure array of relative reflectance spectra R_rel and a structure containg the panel calibration data by typing R_abs absolutereflectance R_rel P If the panel calibration spectrum was recorded with t
9. radiance S C_L Similarly if S is a structure array of reference field spectra and C_E is the system response to irradiance then irradiance can be calculated by typing E irradiance S C_E Although the radiance and irradiance functions perform exactly the same calculation they should be applied to different types of spectra and give results in different units 6 Comparison with airborne and satellite instruments This section describes the convolve function which can be used to reduce the spectral resolution of field spectra to match the bands of a airborne or satellite instrument A Band class is also introduced which provides a convenient way to load store and plot the spectral response functions of these instruments in MATLAB 2012 07 18 19 version 1 3 6 6 COMPARISON WITH AIRBORNE AND SATELLITE INSTRUMENTS 6 1 Introduction The need often arises to compare field spectra with spectra recorded by airborne or satellite spectroscopic instruments such as imaging spectrometers These instruments typically have poorer or much poorer spectral resolution than field spectrometers and will therefore provide less detailed spectra In order to make a sensible comparison the spectral resolution of the field spectra must be reduced to match the spectral response functions bands of the airborne or satellite instruments This is done by convolving the field spectra with the response functions The types of instruments fall
10. separated values CSV format An example is shown in Figure 2 and included in the examples folder Each line of the text file gives the name of one target spectrum followed by the name of its corresponding reference spectrum Logsheets for all of the Field Spectroscopy Facility s instruments can be downloaded as PDF files To pair up target and reference spectra first import all the spectra into MATLAB by typing s importasd txt Then use the pair function to separate and pair target and reference spectra For example if the logsheeet is in a file in the current folder called logsheet csv type tar ref pair s logsheet csv If output is not suppressed this displays tar 1x17 struct array with fields name datetime header wavelength data pair 2012 07 18 11 version 1 3 6 4 PROCESSING FUNCTIONS x 10 x 10 5 A 5 B D 2O z 45 4 5 S m 4 4 940 960 980 1000 1020 940 960 980 1000 1020 Wavelength nm Wavelength nm os AvNIR _ 1 aN e As wine e Aisin Figure 6 A small region of a spectrum recorded on an SVC HR 1024 spectroradiometer showing overlapped data A The VNIR detector records wavelengths up to 1005nm whilst the SWIR1 detector starts at 962nm When the spectra are joined B at 980nm a sharp jump in the intensity occurs ref 1x4 struct array with fields name datetime header wavelength data This separ
11. target spectra with corresponding reference spectra using a logsheet file Calculate a relative reflectance spectrum from paired target and reference spectra Calculate an absolute reflectance spectrum using calibration data for a reflectance panel e Remove erroneous spectral data caused by high absorption in the water bands e Smooth spectra with a Savitzky Golay filter e Convolve spectra to the spectral response function bands of airborne and satellite instruments This document exlpains how to install the toolbox how to handle and plot spectral data using MATLAB structures and how to use the provided processing functions 2 INSTALLING THE TOOLBOX 1 1 Contributor information and the User Group This toolbox was developed by Iain Robinson and Alasdair Mac Arthur at the Field Spec troscopy Facility in Edinburgh This work was supported by the Natural Environment Research Council Some features of the function to read ASD binary files were based on code contributed by Andreas Hueni from University of Z rich Spectral response functions for a number of satellite sensors was provided by Tim Malthus Guillaume Drolet Julia McMorrow Elizabeth Lowe and Reno Choi provided useful discus sion about the convolution of spectral data with the spectral response functions of airborne instruments Appendix B on using ViewSpec Pro was written by Peter Walker and Chris MacLellan The Field Spectroscopy Facility s User Group provides
12. where the toolbox was installed A template for Microsoft Excel is also provided to read and write files in this format The template can be found in the excel folder 2012 07 18 18 version 1 3 6 6 COMPARISON WITH AIRBORNE AND SATELLITE INSTRUMENTS Radiometric calibration data for calibrations performed at the Field Spectroscopy Facility are available in an Excel spreadsheet MATLAB cannot import this spreadsheet directly The data set for the instrument used must exported to an XML file using the provided Excel template To import a radiometric calibration XML file C_L importradcalfadcalexample xml The data file is imported into a structure array If output is not suppressed with a semi colon at the end of the line then the structure is displayed C_L name FSF radiance calibration example datetime 27 Oct 2009 12 00 00 header 1x1 struct wavelength 2151x1 double data 2151x1 double The wavelength and data fields give the system response measurement at each wavelength The header field provides additional information imported from the XML file about the calibration such as the instrument s serial number and the calibration standard which was used to measure the system response 5 5 Calculating radiance and irradiance If S is a structure array of target field spectra and C_L is the system response imported with the importradcal function then radiance can be calculated by typing L
13. ARISON WITH AIRBORNE AND SATELLITE INSTRUMENTS Unfortunately the source spectrum is not usually known However if the HR instrument has a spectral resolution significantly higher than the LR instrument its spectral response funciton may be sufficiently narrow that the source spectrum can be approximated by the HR spectrum Srr A x Ssourcel A Substituting into the above equation Str A J SHR Asource fLR _ Asource dAsource 0 If fur is known or modelled then this convolution can be performed numerically 6 5 In MATLAB The function convolve provides a means to convolve a spectrum or spectra with the spectral response functions of a specific airborne or satellite instruments The first step in this processing function is to download the spectral response functions bands for the specific instrument A MATLAB class called Band is provided to facilitate handling these data A class works in a very similar way to a structure array however classes can also contain methods An introduction to classes is given in the MATLAB documentation A selction of band data for various instruments is available from the Field Spectroscopy Facility s web site These data are provided as XML files and are listed on the Field Spectroscopy Facility s web site The class Band can be used to load response data into MATLAB For example to load spectral response data for the POLDER instrument type POLDER Band http fsf
14. THE UNIVERSITY of EDINBURGH Edinburgh Research Explorer The Field Spectroscopy Facility Post Processing Toolbox User Guide Citation for published version Robinson amp MacArthur A The Field Spectroscopy Facility Post Processing Toolbox User Guide Post processing spectral data in MATLAB Link Link to publication record in Edinburgh Research Explorer Document Version Peer reviewed version General rights Copyright for the publications made accessible via the Edinburgh Research Explorer is retained by the author s and or other copyright owners and it is a condition of accessing these publications that users recognise and abide by the legal requirements associated with these rights Take down policy The University of Edinburgh has made every reasonable effort to ensure that Edinburgh Research Explorer content complies with UK legislation If you believe that the public display of this file breaches copyright please contact openaccess ed ac uk providing details and we will remove access to the work immediately and investigate your claim OPEN ACCESS Download date 16 Dec 2015 The FSF Post Processing Toolbox User Guide Post processing spectral data in MATLAB Robinson and A Mac Arthur Field Spectroscopy Facility Natural Environment Research Council 1 Introduction The Field Spectroscopy Facility FSF Post Processing Toolbox is a MATLAB toolbox containing functions for importing optical spectra from fiel
15. ates the target and reference spectra into two separate structure arrays called tar and ref Note that the tar structure array has a field called pair which gives the name of the paired spectrum This field is used by the relativereflectance function to calculate reflectance spectra see Section 4 3 4 2 Removing overlapped data Spectroradiometers that cover both the visible near infared VNIR and short wave infared SWIR spectral regions have multiple detectors For example the SVC HR 1024 has a silicon Si array detector for the VNIR spectral region and two indium gallium arsenide InGaAs array detectors for the SWIR region There is a small area of overlap around the long wave edge of the Si VNIR detector and the short wave edge of the first InGaAs SWIR detector SWIR1 This overlap region is typically in the range 960 1050 nm Figure 6 A shows the overlap region in a field spectrum The overlapped data can cause problems for processing and must usually be removed prior to any further processing On ASD spectroradiometers the overlapped region is removed automatically by the oper ating software therefore ASD spectra will never contain overlapped data On the SVC HR1024 the overlapped data may be removed or preserved depending on the OVER LAP MATCHING settings chosen in the SVC operating software accessed through the 2012 07 18 12 version 1 3 6 4 PROCESSING FUNCTIONS SETUP menu The Facility recommends setting this optio
16. d portable specroradiometers and processing them MATLAB is a computer environment and high level programming language which provides a flexible environment for processing spectra as well as a good set of built in data structures functions and plotting tools This toolbox is designed as an add on to MATLAB which will make it easier to import examine and process data related to field spectroscopy Spectra acquired in the field must be post processed to plot and examine spectra remove invalid data and apply equipment calibrations MATLAB provides an ideal environment for all these functions as it provides a flexible environment and set of tools for importing plotting analysing and processing data This toolbox is designed to make the handling of field spectra easier It provides a number of functions to import the data file formats used by various instrument manufacturers including e FieldSpec spectroradiometers manufactured by Analytical Spectral Devices ASD e The GER 1500 GER 3700 and HR 1024 manufactured by Spectra Vista Corporation SVC e The OOI binary file format used by Ocean Optics SpectraSuite software e The V SWIR data file format used by the Field Spectroscopy Facility FSF Once imported into MATLAB these data can readily be plotted or further processed This toolbox provides the following convenient processing functions to e Remove overlapped spectral data occuring at the join between different detectors e Sort and pair
17. e high absorption of water results in a very low irradiance E A at ground As reflection is divided by irradiance Rapbs A aa the errors transmitted to the absolute reflectance can become very large This manifests as noisy regions in spectra These regions are often ommited from plots The function removewater deletes the data points in the above water band regions Type 2012 07 18 16 version 1 3 6 5 RADIOMETRIC CALIBRATION 30 r 30 25 25 2 20 20 Q QO C S 15 15 O 2 10 10 D 5 5 S 0 0 500 1000 1500 2000 2500 500 1000 1500 2000 2500 Wavelength nm Wavelength nm Figure 8 Example of post processing The original spectrum A contains overlapped data which were removed with the removeoverlap function The join wavelength was 980nm The spectrum was then smoothed with the sgsmooth function The water bands were removed with removewater resulting in the output spectrum B S_nowater removewater s to delete the water bands regions from the structure array s returning a new structure array s_nowater The data points are removed by replacing them with the special value Not a Number NaN This value is commonly used for undefined or unrepresentable numbers A more detailed description of NaN is given in the MATLAB documentation Figure 8 shows an example of water band removal 5 Radiometric calibration For instruments that have been calibrated this section describes how to apply the ca
18. e spectra The information about which target spectrum should be paired with which reference spectrum is contained in the pair field of the target spectra Section 4 1 describes how to pair spectra Note that the number of reflectance spectra will equal the number of target spectra 4 4 Absolute reflectance Absolute spectral reflectance Raps A as a function of wavelength is the ratio of the target spectrum L A to the spectral irradiance A x E Raabs amp Generally in field spectroscopy F A is not measured directly but instead a spectrum of the irradiance reflected from a reference panel is recorded What is measured therefore The software used to record spectra on a handheld device PDA does not have overlap matching settings and preserves overlap by default 2012 07 18 13 version 1 3 6 4 PROCESSING FUNCTIONS is the relative irradiance Ey i A This is the spectral irradiance E A multiplied by the spectral reflectance of the panel Rpanei A Exei Ropanel A E A If Rpanel A is known then absolute reflectance can be calculated from the measured rela tive reflectance Ras Boy Bat Ryant d Real Therefore to convert a measurement of relative reflectance to absolute reflectance the spec trum must be multiplied by the reflectance of the panel that was used to record it The panel s reflectance spectrum Rpanel A can be measured in the laboratory as a calibration procedu
19. es that would be generated if a known field spectrum were detected by a multiband detector In this scenario the high resolution field spectrum can be assumed to be identical with the source spectrum and substituted for it in the above equation to give Sa f S pieta fa A d Imaging spectrometers are also known as hyperspectral instruments 2012 07 18 20 version 1 3 6 6 COMPARISON WITH AIRBORNE AND SATELLITE INSTRUMENTS The set of spectral response functions f Asource is typically measured as part of the in strument s calibration Armed with this measurement and the field spectrum Sgeiq A the above integral can be calculated The discrete measurements are multiplied interpolating if necessary and the integral is performed with an approximation method such as the trapezoidal rule It is common to label the bands not by their index n but by their centre wavelengths Ae 6 3 Spectrometers A spectrometer has a set of closely spaced spectral response functions which depend on the source wavelength Asource The response of the instrument at detector wavelength A to a purely monochromatic light source at wavelength Asource has the functional form f FlAs Asource It is common to assume and usually the case 7 that the shape of f changes only slightly with source wavelength It can therefore be expressed as a single function shifted to the source wavelength J f A Asource Again the spectral response func
20. ever the configuration is changed 5 2 Radiance Spectral radiance can be calculated by multiplying a measured field spectrum A in digital numbers DN by the system response to radiance Cg A L A CLAS A If C A is measured in a calibration procedure then any spectrum subsequently recorded on the same spectroradiometer in the same configuration can be expressed as absolute radiance L A in SI units To find Cz A a calibration spectrum Seal is recorded in a carefully controlled laboratory setup using a calibrated standard of known radiance Lstandara as the light source Lstandard A C A Seal A This equation can be rearranged to find the system repsonse to radiance Cz A Lstandard A CL E Seal A 5 3 Irradiance Similarly for irradiance a spectrum can be converted to radiometric units by multiplying it by the system response to irradiance E X Ca A S A Using a known source of irradiance Estandara the system response to irradiance can be found Estandard A CRIA 7 Scal A 5 4 Importing the system response into MATLAB Before calculating radiometric spectra the appropriate system response measurements must be imported into MATLAB using the importradcal function The importradcal function reads calibration data in an XML file format An example file in this XML format is provided in the examples folder This folder is located in the FSFPostProcessing1 3 6 folder at the location
21. g of the spectra such as dark subtraction automatically The field processing contains the raw unprocessed data For the V SWIR instrument radiometric calibration data are avail able from the FSF These should should be applied before calcu lating reflectance 2012 07 18 6 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING 3 2 Examining headers and data Imported data are stored in MATLAB structure arrays This ensures that header infor mation metadata is kept together with the spectrum itself wavelength and data The structure of the data and the ways to examine it are described in the following subsections 3 2 1 Structure arrays The spectra are stored in a MATLAB data type called a structure array A single spectrum is a single structure whereas multiple spectra are grouped together and numbered in a structure array The structure is divided into fields which contain individual pieces of data A spectrum structure typically contains the following fields e name is the name of the spectrum usually taken from the filename during importing e datetime is the date and time the spectrum was recorded e header is a structure containing all the header information metadata from the original file pair appears only in target spectra and gives the name of the corresponding reference spectrum e wavelength is a column vector of wavelengths in nanometres e data is a column vector of the corresponding val
22. g spectral data files Each instrument manufacturer uses a different data file format for field spectra A separate import function is provided for each and they are described in the following subsections 3 1 1 Analytical Spectral Devices ASD Files from ASD FieldSpec 3 and FieldSpec Pro spectroradiometers use a binary format which must first be converted to text files using ViewSpec Pro This tool is available from ASD s Support Central web site At the time of writing the latest version was 5 6 10 The procedure to convert binary files to ASCII text is described in Appendix B An ASD text file can be imported into MATLAB by typing s importasd filename where filename is the name of the file to be imported Multiple files can be imported at once using wildcards For example if the current directory contains several ASD text files with the txt extension they can be imported by typing s importasd txt The imported spectrum or spectra will be stored in a structure array in the workspace If output is not suppressed with a terminal semi colon a struct array will be shown s 96x1 struct array with fields name datetime header wavelength data The type of data imported into s data depends on the operating mode of the ASD spectroradiometer If the spectra were recorded in white reference mode the data values will be reflectances in the range 0 1 and further processing can continue If the data were recorded in ra
23. ght each file in the list From the Process menu select ASCII Export e Ensure the boxes buttons circled in red are selected e NOTE The new ASD ViewSpec Pro software allows different data formats and derivatives to be selected if required see the dialogue box below DN and derivative none are recommended e Click OK to convert the files to ASCII and save them in the Output directory e Close the ViewSpec Pro application ASCII Export If using the old version of Data Format for asd files only ViewS pec Pro 4 0 5 the C Reflectance C Radiance lrradiance additional data formats are not S Bae Ease available and the box will look like Log 1 T C Transmittance this Derivative one C 1st C 2nd Set Derivative Gap Data Organization columns Print ONLY Header Information C Rows ASCII Export Headers Data Organization ar Header Information Cous Print ONLY Header Information Rows Axis Field Seperator Qa favelength ey Channel ele Axis Print X Axis Field Seperator pwavetenath Channel je Column Title Column Title int Column Title rint Column Title prin FileName s at Top of Column Print Collect Timefs at Top of Column pain FileName s at Top of Column Print Collect Time s at Top of Column Print Description Note Print Description Note
24. he same spectrometer as the field spec trum then both will have the same the set of wavelength values A If they were recorded on different instruments the panel spectrum will be interpolated to the wavelengths of the relative reflectance spectrum Once calculated the absolute reflectance spectra can be plotted by typing plot R_abs wavelength 100 R_abs data legend R_abs name xlabel Wavelength num ylabel Absolute reflectance title Reflectance spectra recorded on SVC GER 1500 4 5 Smoothing Spectra can be smoothed with a Savitzky Golay filter 6 by typing s_smoothed sgsmooth s This smooths all spectra in the structure array s returning a structure array of smoothed spectra s_smoothed Note that the smoothing operation reduces the wavelength range of the spectra The smoothed spectra will therefore have a different set of wavelength values than the original The function sgsmooth makes use of MATLAB s sgolay function to design the filter This function is part of MATLAB s Signal Processing Toolbox Further information can be found in the documentation for sgolay 4 6 Removing water bands The solar irradiance reaching the ground can be very low in some spectral regions due to water absorption The table below gives two spectral regions where water absorption is particularly high Start wavelength End wavelength Water band 1 1350 nm 1460 nm Water band 2 1790 nm 1960 nm Th
25. his occurs at the joins between the different detectors The removeoverlap function described in Section 4 2 can remove these data 3 1 3 Field Spectroscopy Facility FSF The FSF has developed a portable spectroradiometer called the Visible Short wave Infrared V SWIR Spectroradiometer 3 4 The function importvswir imports data files in the format 5 used by the instrument V SWIR data files usually have a DTA extension A V SWIR data file can be imported by typing upwelling downwelling importvswir filename where filename is the name of the file to be imported Multiple files can be imported at once using wildcards For example if the current directory contains several V SWIR data files with the DTA extension they can be imported by typing upwelling downwelling importvswir DTA The imported structure arrays contain upwelling and their corresponding downwelling spec tra If output is not suppressed with a terminal semi colon then the structure arrays will be displayed upweling 1x100 struct array with fields name datetime header pair processing wavelength data downwelling 1x100 struct array with fields name datetime header processing wavelength data The V SWIR instrument records a downwelling reference spectrum for every upwelling target sectrum There will therefore always be the same number of upwelling and down welling spectra The importvswir function does some basic processin
26. ilt in comands or in the PLOT EDITOR For example the plot of target spectra shown in Figure 5 was produced by typing 2012 07 18 10 version 1 3 6 4 PROCESSING FUNCTIONS plot tar wavelength tar data legend tar name xlabel Wavelength num ylabel Counts DN title Target spectra recorded on SVC GER 1500 See overview of plotting in the MATLAB documentation for more ways to customize plots 4 Processing functions This section describes some of the processing functions in the toolbox required to process the imported data and produce reflectance spectra 4 1 Pairing target and reference spectra This process is usually only required when data have been recorded in raw mode on an ASD spectroradiometer In order to calculate reflectance spectra the raw target and reference spectra must be paired so that each target spectrum has a corresponding reference spectrum Once this is done reflectance can be calculated by dividing the two spectra using the relativereflectance function described in Section 4 3 For SVC spectroradiometers the pair function as the instrument keeps track of target and reference spectra using the target reference button s The information required to pair target and reference spectra is usually recorded in the field on a logsheet This information must be imported into MATLAB to pair up the spectra To do this the names of the spectra are copied into a text file in the comma
27. ined in the function ASDFieldSpec Reflectance spectra recorded in white reference mode are not normalized The ASD FieldSpec 3 and FieldSpec Pro spectroradiometers have three separate detectors for three different spectral regions A silicon photodiode array detects light in the visible near infrared VNIR region Two InGaAs photodiodes cover two short wave infrared spectral regions labelled SWIR1 and SWIR2 2012 07 18 23 version 1 3 6 A NORMALIZATION OF ASD SPECTRA IN RAW MODE l VNIR SWIR1 SWIR2 A 1 2 A and A2 are the join wavelengths These may be different for different instruments but the values are saved in ASD spectrum files They can be found in the header structure in fields named Join1Wavelength and Join2Wavelength The pixel values DN are normalized differently in each spectral region DN A yey oo DN A ae DNnorm A STS Ay lt lt AQ G DN A seus 2 lt A where Tynqp is the integration time of the VNIR photodiode array Ggwyiri is the gain of the SWIR1 photodiode and Ggwyrz is the gain of the SWIR2 photodiode These values are saved in ASD spectrum files and are imported into the MATLAB workspace as fields in the header structure called VNIRIntegrationTime SWIR1Gain and SWIR2Gain respectively 2012 07 18 24 version 1 3 6 B Using ViewSpec Pro to Convert ASD Binary Files to ASCII The application ViewSpec Pro from ASD includes many useful features such as graphing scaling 1 deriva
28. libra tion data to convert reference and target spectra to radiometric SI units 5 1 Introduction Absolute spectral measurements are those expressed in SI derived units A calibrated field spectroradiometer can make measure two key radiometric quantities spectral radiance and spectral irradiance As spectral quantities both are functions of wavelength A The conventional SI units for these quantities are given in the table below Quantity Symbol Units Calibration standard typical Radiance L A Wsr tm 2nm FEL lamp Irradiance A Wm nm Integrating sphere lamp To make absolute measurements the spectroradiometer must first be calibrated a process usually performed in the laboratory using a calibrated light source All spectrometers measure a spectrum in digital numbers DN which must then be con verted to the appropriate radiometric quantity by multiplying the spectrum by the system response for that radiometric quantity The system response measures the signal level 5The system response is also known as the calibration gain 2012 07 18 17 version 1 3 6 5 RADIOMETRIC CALIBRATION at each wavelength to a known source of radiance or irradiance It depends on many aspects of the spectroradiometer the elements in the optical pathway the properties of the detectors and the choice fore optic For this reason each calibration is specific to a certain configuration of the spectroradiometer It must be performed again when
29. n displaying the header field names as illustrated in Figure 3 3 2 5 Formatting data as a single numeric array Spectrum data readily be copied into a single matrix by typing A s data The square brackets in this expression concatenate the numeric values in the data field into a single matrix A The matrix will contain all the spectral data arranged in columns Usually all spectra in a structure array will have the same wavelength scale If this is the case the vector of wavelengths can be copied into a separate variable say w by typing w s 1 wavelength Alternatively it is often convenient to arrange both wavelength values and the spectrum data in a single matrix with wavelengths in the first column and data in subsequent columns as illustrated in Figure 4 This can be done by typing B s 1 wavelength s data The matrix can then be opened in the variable editor by typing openvar B Or selecting the variable B in the WORKSPACE BROWSER Note that when arranging the data in this way the data for first spectrum will be in column 2 the data for the second will be in column 3 etc 3 3 Plotting MATLAB provides all the functions required to produce publication quality plots of field spectra A single spectrum stored in a structure e g s can be plotted by typing 2012 07 18 9 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING i x 10 Target spectra recorded on SVC GER 1500 11 Jun 2010 12 52 34 1454
30. n to preserve and removing the overlap during post processing A function called removeoverlap is provided in the toolbox to join the VNIR and SWIR1 regions at a specified join wavelength For example to remove overlap from target and reference spectra type by joining the two regions at 980 nm type tar_joined removeoverlap tar 980 ref_joined removeoverlap ref 980 After joining the spectra there is usually a sharp jump in the spectral data value either side of the join wavelength Figure 6 B shows an example of a spectrum with overlap removed This toolbox does not at present provide any matching algorithms to remove this feature Note that removing overlapped data changes the set of wavelength values in the spectrum The joined spectra will therefore have a different wavelength scale 4 3 Relative reflectance Spectral relative reflectance Rre as a function of wavelength A is defined as the ratio of the target spectrum L A to the corresponding relative reference spectrum E 1 A The relative reflectance spectrum is usually measured in the field by recording a spectrum of the light reflected from a reference panel The function relativereflectance calculates relative reflectance spectra by dividing each target spectrum by its corresponding reference spectrum If tar and ref are structure arrays of paired target and reference spectra typing R_rel relativereflectance tar ref calculates relative reflectanc
31. nerc ac uk user_group bands POLDER xml This loads the data into MATLAB and stores it in an object called POLDER To plot the bands type POLDER plot By default the spectral response functions are are normalized to unit area The normalizeHeight method can be used to normalize such that the height of each response function is 1 POLDER normalizeHeight plot To convolve a field spectrum in a structure array S with the spectral bands type t convolve s POLDER If the spectrum S and the bands POLDER are defined on different wavelength scales the bands will be interpolated The colvolved spectra will be output in a structure array t If the band centre wavelengths have been defined the output spectrum can be plotted by typing plot t wavelength t data 2012 07 18 22 version 1 3 6 A NORMALIZATION OF ASD SPECTRA IN RAW MODE 6 6 Feature depth estimation The depth of an absorption feature in a spectrum can be estimated using the method described by Clark and Roush 9 The function featuredepth provides an illustration of the method If s is a spectrum the depth of an absorption feature between wavelengths wi and w2 can be estimated by typing wf depth featuredepth s wi w2 The output wf gives the wavelength of the feature The funciton also plots an illustration of the process used to estimate the depth References 1 Milton Edward J Progress in field spectroscopy Remote Sensing of Environment
32. nse functions of airborne or satellite instru ments requires the band data for the specific instrument Data for a range of instruments are available from the User Group 2012 07 18 2 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING E E MAILAK 929 MATLAB amp Communications Toolbox Ga Edit Debug _ Parallel Dest E FSF Fost Processing Toolbox New gt ry Getting Started Open 0 g Example Close Command Window 38W ts H 6 Function reference ec B Class reference Import Data T User Guide PDF Save Workspace As S y Image Processing Toolbox gs Ee H Mapping Toolbox set Path S Preferences p Neural Network Toolbox h M Cinan Menanee inn Taalhas Figure 1 Add the directory containing the toolbox to the MATLAB search path Addi tional documentation for the toolbox will appear in the help broswer 2 2 Download and install To install the toolbox first download and unzip the file then add it to the MATLAB search path 1 Download FSFPostProcessing1 3 6 zip This zip file contains a folder called FSFPostProcessing1 3 6 which contains all the func tions documentation and examples in the toolbox 2 Unzip the file in a folder which is accessible to MATLAB If MATLAB is running on a server the toolbox files may need to be located on the server 3 In MATLAB add the FSFPostProcessing1 3 6 folder to the search path This can be done using the SET PATH tool which can
33. re and the calibration data then applied to field spectra in post processing Calibration data for the all Field Spectroscopy Facility s reference panels are available in an Excel spreadsheet A reference panel calibration spectrum Rpanel A can be imported into MATLAB using the importpanelcal function Two file types are supported 1 A comma separated values CSV file with a header which gives information about the panel s calibration 2 An Excel spreadsheet provided by the Field Spectroscopy Facility An example of a panel calibration file in CSV format is shown in Figure 7 This file can be used as a template for panel calibration data if required The header must contain the panel s name This should be a unique name or serial number which identifies which panel the calibration refers to The date and time at which the calibration was performed must also be included in the header To import a panel calibration file in CSV format into MATLAB type p importpanelcal panel csv Alternatively panel calibration data may be imported from an Excel spreadsheet provided by the Field Spectroscopy Facility As the spreadsheet contains data for all the Facility s panels the serial number of the panel to be imported must be specified P importpanelcal FSF Ref Panel Cal Data 2010_1 xls SRT 008 MATLAB will issue a warning when importing data from the FSF s Excel spreadsheet to indicate that the xlsread function has
34. tion is generally normalized such that co f Jansi Co The detected spectrum is the response at detector wavelength A due to light from all parts of the source spectrum is found by integrating over all the source wavelengths S A f Ssource Asource f a Asource dAsource 0 This integral is the convolution of the source spectrum with the spectral response function The result is the detected spectrum as a function of wavelength S A Ideally the spectral response function of every instrument would be measured In practice this may not be possible and a variety of methods have been developed to approximate it 8 These generally involve approximating the spectral response functions as a series of Gaussian functions whose widths and centre wavelengths are set up to match the instru ment s specifications 6 4 Reducing the spectral resolution For comparing spectra of high resolution HR ground based field spectrometers with the comparitavely lower resolution LR airborne or satellite instruments the HR data must be reduced in resolution to the LR instrument In other words we wish to know how a particular spectrum acquired on the ground would appear if it had been detected with a lower resolution instrument This question can be answered by convolving the source spectrum with the spectral response function of the LR instrument SLR A f Ssource Aso tce LR A Asource dAsource 0 2012 07 18 21 version 1 3 6 6 COMP
35. tive and conversion of the spectrometer s binary files into ASCII text files For the purpose of this guideline we will only use the ASCII Export function The application is installed on each of the facility s computers and is also available for the Analytical Spectral Device s website ftp ftp asdi com Software contact FSF for further details e Start the ViewSpec Pro application Configuring ViewSpec Pro The application can save the path directory to your ASD spectrum files and the converted text files e From the Setup menu click on the Input Directory to select a New Directory Path to your ASD binary data files Please Select a Directory OK Cancel J Test Data BVer 02 aE FRC a OSA aR Opa Pa cP FRSA a FO Sm 39 EMO oT Ons Srmusrene9 5 veossem adic trason After selecting the default Input Directory you are offered the opportunity to make the Output Directory match the Input Directory Alternatively you can select a different path directory using the Setup Output Directory menu Open ASD Spectrum Binary Files ViewSpec Pro can open and process large numbers of files although graphing is limited to 14 spectra e From the File menu select Open and highlight the ASD White Ref or radiometric binary files for importation e Click Open to bring the files into ViewSpec Pro Converting ASD Binary Files to ASCII text The file list is shown in the application window e Highli
36. ues These will generally be uncal ibrated digital numbers For ASD spectrometers running in white reflectance mode these values will be reflectances in the range 0 1 It is straightforward to add additional information to existing structures if desired For example to add a light reading in lux to an existing structure s lux 15000 A new field called lux would then be automatically added Further information on structure arrays is available in the MATLAB documentation 3 2 2 Workspace browser Once imported the spectra can be examined in the workspace browser This can be opened by selecting WORKSPACE from the DESKTOP menu or type the command workspace The spectra will be visible as structure arrays with the names given when imported Double click an array to browse its contents If the strucure contains multiple spectra they will be listed as a row vector Double click again examine a specific spectrum More information on using the workspace browser is available in the MATLAB documen tation 3The source of this data may be the spectrometer s internal clock or may be the clock of the computer or PDA used to record the spectrum 2012 07 18 7 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING H File Edit View Graphics Debug Desktop Window Help Mm 83 B amp A W Stack Base QD select data to plot X H lt 13x8 cell gt 2 3 4 5 ae N faro6ti 70 000 gr06111 gr06111 gr06111 F 2
37. volume 113 pp 92 S109 2009 2 Spectra Vista Corporation HR 1024 User Manual 1 5 edition 2008 3 MacLellan Chris J and Malthus Tim J High performance dual field of view spec troradiometer with novel input optics for autonomous reflectance measurements over an extended spectral range IGARSS 2009 4 Robinson Iain and MacLellan Chris J A dual field of view spectroradiometer for near simultaneous measurement of irradiance and reflected radiance 2011 5 MacLellan C V SWIR data file format and remote control command set Field Spec troscopy Facility 7 edition 2010 6 Savitzky Abraham and Golay M J E Smoothing and Differentiation of Data by Simplified Least Squares Procedures Analytical Chemistry volume 36 no 8 pp 1627 1639 1964 7 James J F Spectrograph Design Fundamentals Cambridge University Press 2007 8 Milton E J and Choi K Y Estimating the spectral response function of the CASI 2 Proceedings of the Annual Conference of the Remote Sensing and Photogrammetry Society 2004 9 Clark R N and Roush T L Reflectance spectroscopy quantitative analysis techniques for remote sensing applications J Geophys Res volume 89 p 6329 1984 A Normalization of ASD spectra in raw mode ASD spectra recorded in raw mode must be normalized to account for the different re sponses of the detectors The normalization is performed during import and the code is conta
38. w mode the spectra must be sorted into reference and target spectra before reflectance can be calculated This process is described later 3 1 2 Spectra Vista Corporation SVC Files from SVC spectroradiometers GER 1500 GER 3700 and HR 1024 are stored in the signature text file format 2 These files usually have a sig extension Each file contains a header followed by a pair of spectra one target spectrum and its corresponding reference spectrum A SVC signature file can be imported by typing This toolbox has very limited support for ASD s binary file format so conversion from binary to ASCII text is recommended The importasd function automatically normalizes data recorded in raw mode to account different in tegration time settings on different detectors The normalization method is described in detail in Appendix A 2012 07 18 4 version 1 3 6 3 IMPORTING EXAMINING AND PLOTTING OO _ logsheet log Example logsheet file Each line is a target reference pair Dn1 01 Dn1 000 Dn1 0 2 Dn1 000 Dn1 03 Dn1 000 Dn1 0 4 Dn1 000 Dn1 07 Dn1 006 Dn1 8 Dn1 006 9 Dn1 0 9 Dn1 006 10 Dn1 10 Dn1 006 11 Dn1 12 Dn1 011 h 12 Dn1 13 Dn1 011 13 Dn1 014 Dn1 011 14 Dn1 15 Dn1 011 15 Dn1 017 Dn1 016 16 Dn1 18 Dn1 016 17 Dn1 019 Dn1 016 18 Dn1 020 Dn1 016 OurWNP on Line 6 Column 17 Plain Text v TabSize 2 gt Figure 2 Spectral data recorded in raw mode can