Contents
1. lisse 5 Chiller Location 0 0 2 ee ee eens 5 Ventilation voor a LRA oY earn ed Dee Po EE Be ee 5 Before Operating llli 5 POWSIRGOIO sodes poca a tuse doi edu wes de edt 5 SI Pr is E pe es a woe ese ee 6 Bottom Shelves 0 0 cc ccc eee eee eee 6 Wire Shelves acces rama anata a Seen oe ce Lee ed nae 6 2 Operation Automatic Start Up asnasan cts 7 Loading Product reg rues ere ET Rue rare 7 EMS Controller Operations 0000 c cence eee 8 INTOQUCUIO EE 8 Self Learning 00 cee eee nen 8 Motion Sensor amp Reed Switch liliis 8 Faceplate sive se ibv be ie Eee xen br dese ados e died 9 Temperature Setpoint ooococcoococcco lees 10 Perishable Mode 0 0 cece ee eee een 10 Messages and Alarms 0 00 e eee eee 11 3 Servicing SKOPE B1200 2 B1200G 2 Isolating Electrics 0 0 eee 12 Cleaning 4 ied eed baw Ea ean ghee e x WER eee bey 12 Cabinet a Mek be nd d ex RO RR eG De e Pee 12 Condenser Coil 0 00 cece tees 12 LINO ees xe we A AA Rv 13 Interior Light soci T OE dd rr ad rcr KR o e SR 13 SIGN Eight 222 rre enr beau eter ren ee deriva deed 14 Troubleshooting es srra kE 000 ee eee tee eee eee 15 User Manual SKOPE B1200 2 B1200G 2 1 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference When the a
2. has been positioned in a suitable place plug it in and check the following activity Item Activity Condenser Fan The condenser fan starts and reverses temporarily The lights that illuminate the top sign and cabinet interior Lighting will come on when the chiller is turned on An electronic controller runs the chiller and is visible Electronic behind the front panel The display panel first flashes start Controller up messages before stabilising on the cabinet temperature The compressor starts about three minutes after the lights go on To verify listen for the compressor and check that the COMPRESSOR light is green on the EMS Advanced Compressor controller The compressor turns off when the product temperature reaches around 2 C and turns on again when it reaches about 4 C Evaporator Fan The evaporator fan starts about 30 seconds after the compressor To verify check that the FAN light is green on the EMS Advanced controller After initial start up the EMS Advanced electronic controller starts its self learning process and the cabinet will operate without any assistance Refer to Self Learning on page 8 for more information Loading Product Let the chiller run 30 minutes before loading it with product the first time When loading the chiller o Allow adequate air space around each item to ensure even cooling and efficient operation of the chiller Do not exceed a maximum lo
3. User Manual MAN10364 Rev 2 0 Mar 2012 B1200 2 B1200G 2 SKOPE Two Door Vertical Chiller B1200 2 no sign G12EV X5621 B1200G 2 lit sign G12EV B1200G 2 Refrigeration B1200 2 B1200G 2 SKOPE Two Door Vertical Chiller Type G12EV X5621 G12EV User Manual MAN10364 Rev 2 0 Mar 2012 2011 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SEXE is a registered trademark of SKOPE Industries Limited SKOPE INDUSTRIES LIMITED Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applies any other trade mark to the product Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to Successors or assignees of the buyer Future owners of the product CONTENTS 1 Installation Safety First sceana dr rea ded eoe UP a a ORG RS 4 Positioning the Cabinet
4. ad of 20kg per shelf Remove some product if the shelves are flexing Do not let anything overhang the shelves because this might stop the doors from shutting or even break something User Manual SKOPE B1200 2 B1200G 2 Introduction Self Learning Motion Sensor amp Reed Switch EMS Controller Operations The Energy Management System EMS Advanced controller faceplate is located inside the refrigeration unit compartment with the faceplate visible behind the front panel The EMS Advanced controller detects variable business hours and switches the chiller to active mode approximately two hours prior to opening and then changes to stand by mode at close of business While in the economical stand by mode the temperature inside the chiller is moderated and the cabinet lights turn off CAUTI ON The EMS Advanced controller must only be adjusted by an authorised service agent After initial start up the EMS Advanced controller goes into learning mode for 24 hours to establish the density of shopper traffic and the business s opening closing pattern It s always gathering data about shopping activity and updating itself A service agent is not required if the store hours change or you disconnect the power to move the chiller The EMS Advanced controller continuously collects data from two sources o amotion sensor n reed switches IMPORTANT Disconnecting the refrigeration unit from the power supply does
5. cessary air gap atthe rear of the cabinet for correct operation Back of Chiller Power Cord Power Cord Thechiller has a flexible power cord fitted with a 3 pin plug which exits the rear of the cabinet at floor level Pull the power cord around so that it s not trapped before you position the cabinet Installation 5 User Manual SKOPE B1200 2 B1200G 2 Bottom Shelves Wire Shelves Shelves The chiller is supplied with eight wire shelves and two solid bottom stainless steel shelves The two solid bottom shelves are fixed into place on the floor of the chiller It is important that these shelves are always in place as they direct the interior air circulation IMPORTANT For correct chiller operation the two bottom shelves must always be in the bottom of the chiller The wire shelves may be fitted at different heights to suit various products Each shelf is held in place with four shelf clips which engage in the shelf support strips The support strips are numbered for easy location of shelf clips To fit the wire shelves 1 Unpack the shelves and shelf clips from inside the cabinet 2 Establish the desired position for the shelves and securely engage a shelf clip in each of the shelf support strips 3 Sitthe shelves onto the shelf support strips Installation User Manual 2 Operation SKOPE B1200 2 B1200G 2 Operation Automatic Start Up After the cabinet
6. de see page 10 Warm cabinet temperatures Compressor operating for long periods more than 1 hour Blocked condenser Poor ventilation around refrigeration unit Clean the condenser coil see page 12 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 Servicing 15 User Manual SKOPE Contacts SKOPE INDUSTRIES LIMITED NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au
7. enu PS will show on the display 8 Push the set button to enter the parameter menu N S c RON 9 Push and hold the set button to scroll through the parameter menu 10 Release the set button when PEr appears on the display 11 Push the up and down button to change the value 12 Once the desired mode setting is flashing on the display leave the controller for 20 30 seconds to save the setting Perishable The B1200G 2 chiller has the ability to operate in either perishable mode or Mode non perishable mode When in perishable mode the symbol on the electronic controller faceplate is lit red when in non perishable mode the symbol is not lit Perishable mode is for use with perishable products such as dairy or food products When in perishable mode the chiller temperature is kept constantly cool at all times During standby periods the lights switch off and the fans cycle on and off Perishable mode must be used when perishable product is being stored inside the chiller I MPORTANT Ensure perishable mode is used when perishable product is being stored inside the chiller Non perishable mode is for use with non perishable products such as carbonated drinks and water When in non perishable mode the chiller temperature is moderated the lights switch off and the fans cycle on and off during standby periods resulting in maximum energy savings Follow the steps below to change between pe
8. h can be replaced by removing the front sign panel To replace the sign light 1 Remove the front panel and isolate the chiller from the mains power supply see page 12 Remove the sign assembly Lift the assembly up and off the sign sides and unplug it from the cabinet o gt Screw driver e Remove the sign top cover by undoing the fixing screws from the top of the sign assembly Sign Assembly Slide the clear front panel and artwork if present up and out of the sign Assembly Screw driver Undo the two inner lampholder fixing screws from the rear of the sign assembly Outer screw loosen Inner screw remove Loosen the two outside screws vertical slot screws and slide the lampholder brackets and gt LED tube to the bottom of As assembly bad the vertical slots Vertical slot Rotate and remove the Lamp holder Lamp holder bracket failed LED tube Fit the new LED tube LED tube Slide the lampholder brackets and LED tube to the top of the vertical slots and tighten the outside screws vertical slots screws 10 Screw the two inner screws back into the assembly to fix the lampholder brackets and LED tube in place 11 Refit the clear front panel and artwork if present and screw the sign top cover back onto the top of the sign assembly 12 Plug the sign assembly back into the cabinet and slot the assembly back ont
9. not reset the self learning module Only an authorised service agent can adjust the program The motion sensor detects activity in front of the chiller and feeds data to the EMS Advanced controller The motion sensor is located on the faceplate of the EMS Advanced controller visible on the front panel The chiller is fitted with reed switches one below each door The reed switches tell the EMS Advanced controller how often the doors are opened A small magnet in teh door frameactivates each switch 4 on Reed Switch Motion Sensor Front Panel EMS Controller Operation User Manual SKOPE B1200 2 B1200G 2 Faceplate Because the EMS Advanced controller plays such an important role it s helpful to know the parts of the faceplate you will use Ae elstat No Item Description DEFROST button Manually activates an additional defrost cycle and used to program 1 the controller The first automatic defrost occurs six hours after the first off cycle 2 E SET button Used to program the controller 3 Eye of the infrared motion sensor lt detects activity within five metres around the front of the chiller and feeds the data to the EMS advanced controller 4 ix LED for the compressor light green when on 5 e s LED for the evaporator fan green when on LED indicating perishable mode red when on Normal condition should be unlit because the chiller is not intended for use with pe
10. o the sign sides Servicing User Manual Troubleshooting SKOPE B1200 2 B1200G 2 For questions about the EMS advanced controller see Messages and Alarms on page 11 For problems with the cabinet and refrigeration cassette use the following table Problem Possible Cause Suggestions Cabinet not operating No controller display Loss of power supply Isolating switch turned off Check mains power supply Check isolating switch see page 12 Interior light not on Failed LED tube Controller is in stand by mode Blown cabinet fuse Replace LED tube see page 13 Movement in front of the motion sensor will reactivate it Contact an authorised service agent to replace it Power consumption is higher than expected Unit operating too hot Cabinet doors are opened excessively Clean the condenser coil see page 12 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 Ensure the cabinet is in a cool spot Ensure doors are closed more often Product is too warm Restricted airflow to cabinet Controller is in stand by mode Controller is in non perishable mode Ensure product is not blocking airflow slots Ensure there is space around individual product pieces Movement in front of the motion sensor will reactivate it Change the controller to perishable mo
11. onitors the voltage level and restores power as Soon as the voltage returns to an appropriate level Operation 11 User Manual SKOPE B1200 2 B1200G 2 3 Servicing 12 Cabinet Condenser Coil Isolating Electrics You should isolate the cabinet from the power supply before attempting any maintenance Use the isolating switch to turn off electrics to the cabinet and refrigeration unit without unplugging the cabinet from the wall The isolating switch is located on the right hand side of the refrigeration unit compartment To isolate the power supply 1 Fully open the cabinet doors and unscrew the front panel 2 Remove the front panel from the cabinet 3 Turn off the power to the cabinet 0 at the isolating switch Cleaning Periodically wipe the inside and outside of the cabinet with a damp cloth taking care to keep moisture away from electrical parts As with any maintenance ensure the cabinet is isolated from the power supply before cleaning To ensure trouble free performance we strongly urge monthly cleaning with a soft brush to remove dust and fluff A more thorough cleaning is recommended every six months by qualified service personnel The condenser coil must be kept clean for efficient and reliable operation WARNING Isolate the cabinet from the power supply before cleaning the condenser coil To clean the condenser coil 1 Remove the front panel and isolate
12. ppliance is used by or near young children or infirm persons close supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration cassette Do not probe any opening Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Only use this appliance with the voltage specified on the cabinet rating label affixed to the refrigeration cassette Ensure the chiller has adequate ventilation as this is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard Ensure all necessary safety precautions are observed during installation or removal of the refrigeration cassette This appliance is not designed to be stable while in motion Use extreme caution when moving or transporting the appliance This appliance is not intended for use with perishable product which are high risk foods likely to support the growth of harmful bacteria Perishable product requires continuously cold temperatures WARNING Alway
13. rishable and non perishable mode To change between perishable and non perishable mode 1 Push and hold the set button PAS Set Up appears on the display 2 Release the set button 3 Push the set button four times 4 Push the up button once Heelstat 5 Push the down button twice 6 Push the defrost button twice Pert oon Continued over page Operation User Manual SKOPE B1200 2 B1200G 2 7 Push the down button to nagivate to the parameter menu PS will show on the display 8 Push the set button to enter the parameter menu 9 Push and hold the set button to scroll through the parameter menu 10 Release the set button when PEr appears on the display 11 Push the down button to change between perishable and non perishable mode 0 Non perishable mode Non perishable mode Perishable mode 1 Perishable mode 12 Once the desired mode setting is flashing on the display leave the controller for 20 30 seconds to save the setting Messages and The following table explains messages that the EMS Advanced controller Alarms displays and related alarms Alarms signal unexpected operational changes in the chiller and stop when you disconnect the chiller from the power supply at the isolating switch Display Description When the chiller is in stand by mode the controller displays three bars This should not be displayed during normal business hour
14. rishable product which are high risk foods likely to support the growth of harmful bacteria Perishable mode requires more energy LED linked to the motion sensor and flashes red when there is activity around the chiller but otherwise off 8 A UP button Used to program the controller 9 v DOWN button Used to program the controller Digital display of cabinet temperature or messages see next page for details The temperature is what the sensor inside the chiller detects and not necessarily the 10 Bnrm product temperature However they may be very close depending on how the controller is set to sense temperature When the chiller is in stand by mode the controller displays three bars This should not be displayed during normal business hours Operation User Manual SKOPE B1200 2 B1200G 2 10 Temperature The chiller temperature setpoint is factory set at 1 C If necessary the Setpoint standard setting can be adjusted between 0 C and 4 0 C SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a time To adjust the setpoint 1 Push and hold the set button PAS Set Up appears on the display Release the set button Push the set button four times Push the up button once Push the down button twice Push the defrost button twice Derrost Down Push the down button to nagivate to the parameter m
15. s When the chiller becomes operational the display changes to the temperature see previous page dEF Defrost cycle in progress Door Open The controller detects an open door through a reed switch in the door and has found one open If it stays open over two minutes an alarm sounds but stops when the door closes dO again If the door remains open five minutes such as when loading product then the alarm stops and the controller turns off the compressor The compressor starts again when the door closes High Temperature The refrigeration system has overheated and Ht an alarm sounds The controller turns off the system to avoid damage Contact a service agent Probe Failure A temperature sensor in the cabinet or condenser HFEOREEE has failed and an alarm sounds Contact a service agent Refrigeration System Failure There is a refrigeration system SF failure and the controller turns it off to avoid damage An alarm sounds when the system does not reach the preset temperature within 72 hours Contact a service agent Supply High The voltage from the main supply is too high and an SHI alarm sounds The controller turns off the electrical motors continuously monitors the voltage level and restores power as Soon as the voltage returns to a safe level Supply Low The voltage from the main supply is too low and an SLO alarm sounds The controller turns off the electrical motors continuously m
16. s isolate the chiller from the mains power supply before attempting any maintenance CAUTION Never overload the power supply which could damage the chiller and product See the rating label inside the cabinet for the safe power supply and current draw Installation User Manual SKOPE B1200 2 B1200G 2 Positioning the Cabinet Chiller The location of the chiller may be the single most important decision that will Location extend its life and ensure economical high performance We recommend that you put the chiller in the coolest place possible because it will use less power and last longer Allow adequate space for doors to open and close properly Self closing doors have internal torsion bars pretensioned at the factory and must be unobstructed Ensure the cabinet sits on a level surface so that the doors shut and correctly seal Level footing also prevents the condensate tray from overflowing Ventilation Ensure there is always at least a 50mm gap around the back top and underside of the cabinet Keep the ventilation slots in the front panel clear at all times never store cardboard cartons or other objects in front of the chiller CAUTI ON To prevent over heating and conserve energy ensure air flows freely all around the chiller including front back top and underside minimum 50mm gap Before Ensure both rear spacers are rotated outwards and fully tightened This will Operating provide the ne
17. the chiller from the mains power supply see above 2 Clean the condenser coil with a soft brush 3 Reconnect the chiller to the power supply and refit the front panel Servicing User Manual SKOPE B1200 2 B1200G 2 Lighting This chiller is designed for use with LED tubes and is not compatible with fluorescent tubes I MPORTANT DO NOT use fluorescent tubes Interior Light The cabinet interior is lit by two 19 Watt T8 LED tubes 26mm x 1200mm which can be replaced without moving shelves or removing product Servicing To replace the cabinet interior light 1 Remove the front panel and isolate the chiller from the mains power supply see previous page 2 Remove the diffuser by squeezing it until it is released from the aluminium housing and then push the diffuser out of the way 3 Rotate the LED tube until LED Tube Pins Lamp Holder the pins on the ends ofthe partially removed tube align with the slots then slide it out 4 Fita new LED tube Note the pointer at each end of the tube should be set to the 0 position 5 Refit the diffuser by slipping the back section into the housing then squeezing and snapping the front section of the diffuser into place as you work down the length of the light 13 User Manual SKOPE B1200 2 B1200G 2 14 Sign Light B1200G 2 only The sign unit is lit by one 22 Watt T8 LED tube 26mm x 1200mm whic