Home

InnohomeMarch 2014 SGK500

image

Contents

1. INNOHOME Stove Guard SGK500 user manual PASSED Test 3 2012 NBLF12102 SINTEF www innohome com Congratulations You now own one of the most intelligent cooker safety products in the world ee Colour options for additional covers Control Unit SGC500 3 1 Innohome Stove Guard and how to use it 1 1 A quick guide 1 2 Structure of the Stove Guard 1 3 Stove Guard use and features 1 4 Meaning of alarm signals 1 5 Sensor Dislocation Alarm 1 6 Automatic fault diagnosis 1 7 Additional devices 2 Monthly Maintenance 3 Low battery alarm 4 Intelligent Heat Sensor Installation 5 Control Unit Installation and Setup 6 Testing after Installation 6 1 Intelligent Heat Sensor test 6 2 Alarm Signal Detection test 6 3 Safety Lock test if activated during the installation 7 Changing the hob type setting 8 Checking the Control Unit settings 9 Setting the sensitivity level of the Intelligent Heat Sensor 10 Alarm output 11 Troubleshooting 12 Technical Information 13 Warranty 14 EU Declaration of Conformity 15 17 18 18 18 STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it 1 1 A quick guide When the Stove Guard is signalling press the Intelligent Heat Sensor cover once Also note that When the Stove Guard is emitting a pre alarm signal a short sound followed by a long break ____ ___ it has identified a hazardous situation I
2. are operated by touch just press the Intelligent Heat Sensor cover once Control Unit a short beep every few sec onds This is the Control Unit pre alarm signal that sounds for one minute before the Intelligent Timer turns the cooker off By pressing the Intelligent Heat Sensor cov er once during the pre alarm signal the cooker shutdown can be prevented Press the Intelligent Heat Sensor cover once during the pre alarm signal Control Unit a short signal at approx imately 5 second intervals The cooker has been turned off due to the Intelligent Timer function detect ing an alarm signal of an external fire carbon monoxide or gas alarm or the Overheating Monitor detecting a dan gerously high temperature or a steep temperature rise First turn all cooker knobs to 0 then press the Intelligent Heat Sensor cover once In cookers that are operated by touch just press the Intelligent Heat Sensor cover once STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it cont Meaning Course of Action Control Unit a short signal followed by a long signal be beep at approx imately 5 second intervals O The cooker has been turned off due to the automatic fault diagnosis detecting a temporary error in the Intelligent Heat Sensor s connection to the Control Unit or in the functioning of a part of the sys tem The
3. hob type setting see section 7 e Return the Intelligent Heat Sensor to its factory settings see section 4 If it is installed higher than 65cm 26 for cookers with electric burners or 70cm 28 for gas burners set the sensitivity level manually see section 9 What to do when replacing the Intelligent Heat Sensor or the Control Unit with a new one See www innohome com for device pairing instructions STOVE GUARD SGK500 USER MANUAL 12 Technical Information Certification CE Casing IP20 Patent FI 117526 Fl 117878 PCT pending Voltage power Connection Features Control Unit 1 3 phase SGC500 2 230VAC 05 3h Alarm Signal Detection SGC500 1 phase and star Intelligent Intelligent Timer connection 1 x 32A Timer Safety Lock only SGC500 2 or 2x 16A Automatic fault diagnosis SGC500 3 400VAC Alarm output delta connection 3 x Connection for powering 16A without N external units 1W Overheating and overload protection Intelligent Wireless Solar powered with 3 25min Intelligent Heat Sensor Heat Sensor 433MHz a battery back up Overheat Max sensing distance 1 2 m SGS500 10mW X10 or external power ing 3 9 ft A1 NO supply 5V Working Monitor Adjustable sensitivity Alarm 80 dB life over 15 years Manual and automatic alarm at 100 cm reset Sensor Dislocation Alarm 13 Warranty This product has a 5 year warranty that covers defects in material or workmanship starting from
4. one Turn the Safety Lock off by pushing the Intelligent Heat Sensor cover once or turn one of the cooker knobs on and off three times at one second intervals turn on turn off wait 1 sec turn on turn off wait 1 sec turn on turn off The Control Unit will emit two signals after a short pause indicating that the electricity has been reconnected and the cooker can be used normally 12 STOVE GUARD SGK500 USER MANUAL 7 Changing the hob type setting The Intelligent Heat Sensor uses different settings for gas and electric burners Changing the hob type setting may be required if the gas burners setting was not successfully implemented during the Intelligent Heat Sensor setup or if you later change your cooker to a different type Changing the setting Detach the Intelligent Heat Sensor if it is attached with screws see detaching instructions from section 4 Mark the Sensor s original installation location if necessary it is important to ensure that after procedures the Sensor is returned back to its original installation location Take the Intelligent Heat Sensor to your hand holding it from the top and the bottom Press the cover towards the bottom so that the green light alights and hold it down Whilst press ing the cover use a screwdriver to push a push button located inside a hole on the bottom surface of the Sensor see image 7 on page 20 Wait until the Sensor emits one or two signals then release the push bu
5. the Stove Guard will sound another alarm and turn the cooker off 1 6 Automatic fault diagnosis Electric cookers The automatic fault diagnosis ensures that the Stove Guard is working per fectly each time the cooker is used for cooking the diagnosis will not start if the cooker is only used for a short period of time eg to boil water The diagnostic tool analyses the function of the Intelligent Heat Sensor and the Control Unit and the radio communication link between the devices The automatic fault diagnosis alarm can also be triggerd by the Intelligent Heat Cm STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it cont Sensor not being in its original installation location or if the Sensor has not been installed correctly If the fault diagnosis detects something abnormal in the functioning of the system the Control Unit will emit a fault signal a short signal followed by a long signal be beep at approximately 5 second intervals and after a minute s time it will turn the cooker off If the fault diagnosis is signalling press the Intelligent Heat Sensor cover once during the first minute of the alarm If the fault diagnosis alarm was triggered by a temporary glitch or by the Intelligent Heat Sensor not being in its original installation location the cooker shutdown will be prevented and cooking can be continued normally If the fault diagnosis alarm was caused by an actual fault situation the alarm
6. the date of purchase The warranty does not cover any indirect damage caused by a mal functioning appliance damage caused by negligence or damage caused by failure to follow the instructions properly 14 EU Declaration of Conformity See www innohome com EUdeclaration IMAGES IMAGES Innohome Ltd www innohome com info innohome com www facebook com innohome Linnoitustie 4B FI 02600 Espoo Finland inno SGK500 000UU1
7. to your hand holding it from the top and the bottom Press the cover towards the bottom so that the green light alights and hold it down Whilst pressing the cover STOVE GUARD SGK500 USER MANUAL 4 Intelligent Heat Sensor Installation cont press the battery disconnection piece downwards so that the Sensor light turns off then remove the battery disconnection piece Wait that the Sensor emits two signals then release the cover The Intelligent Heat Sensor has now been initialized and set to gas burners setting Save the battery disconnec 7 tion piece for possible later use i If the Intelligent Heat Sensor only emits one signal the gas burn ers setting was not implemented successfully In this case see Changing the hob type setting section 7 3 Attach the Intelligent Heat Sensor underneath the cooker hood with magnets as close to the central point of the cooker as possible If the cooker hood has lights make sure there is at least 10 cm 4 distance between the lights and the Intelli gent Heat Sensor If the magnets do not stick to the hood the Intelligent Heat Sensor can be attached using the self attaching installation plate 1 If using the installation plate first make sure that the attaching surface is cleaned and dry With gas cookers the Intelligent Heat Sen sor needs to be installed at the minimum height of 65 cm 26 If the cooker has no cooker hood the Intelligent Heat Sensor can be ins
8. TOVE GUARD SGK500 USER MANUAL 4 Intelligent Heat Sensor Installation cont Detaching an Intelligent Heat Sensor attached with screws see images 4 5 page 20 1 Open the cover by pressing it from holes on its both ends using paperclips for example 1 image 4 Lift the cover up one end at a time image 5 2 Undo the screws Place the cover back as described in Opening and closing the Intelligent Heat Sensor cover on previous page Additional features Detach the Intelligent Heat Sensor from its location if attached with screws see Detach ing an Intelligent Heat Sensor attached with screws above Mark the Sensor s original installation location if necessary it is important to ensure that after procedures the Sensor is returned back to its original installation location Silent alarm Open the cover see Opening and closing the Intelligent Heat Sensor cover on previous page Turn the DIP switch 2 to off position see image 6 on page 20 the image shows the switch in on position Place the cover back according to instructions Turning off the red alarm light flashes during an alarm Open the cover see Opening and closing the Intelligent Heat Sensor cover on previous page Turn the DIP switch 1 to off position see image 6 on page 20 the image shows the switch in on position Place the cover back according to instructions Disabling the Alarm Signal Detection fe
9. ard operation every time the cooker is used for cooking only the Alarm Signal Detection feature needs to be test ed on a monthly basis For the Alarm Signal Detection test refer to the section 6 2 Gas dual fuel cookers Refer to the gas kit manual Clean the Intelligent Heat Sensor by wiping it with a cloth dampened with a mixture of house hold detergent and water Only use a cloth that does not leave fibres STOVE GUARD SGK500 USER MANUAL 2 Monthly Maintenance cont Ensure that all other alarms being used with the Stove Guard are cleaned and their batteries changed according to their instructions 3 Low battery alarm The Intelligent Heat Sensor is powered by solar panels using a battery for back up power The working life of the Sensor is at least 15 years but in practice will be longer if the solar panels receive enough light A low battery in the Intelligent Heat Sensor causes both the Intelligent Heat Sensor and the Control Unit to emit a signal once a minute The battery is fixed and can not be changed When the Sensor is at the end of its working life please take care to recycle the old Sensor appropriately The low battery alarm can be postponed for 12 hours by pushing the Intelligent Heat Sensor cover once The Control Unit will carry on emitting the battery alarm signal after the Intelligent Heat Sensor has been removed or its battery has run out Reset the Control Unit battery signal by turning the electricity
10. ature 1 Press the Intelligent Heat Sensor cover so that the light alights 2 Place the battery disconnection piece into the hole underneath the Sensor 2 see image on previous page Place the Intelligent Heat Sensor on a metallic surface ie a cooker for five seconds bottom surface downwards 3 Lift the Sensor up and put it back on top of a metallic surface for another five seconds 4 Remove the battery disconnection piece Save it for possible later use 5 Press the cover once Put the Intelligent Heat Sensor back to its installation location The Alarm Signal Detection feature has now been disabled Using external power supply Connect the cable to the connection on the bottom of the alarm 1 see image 7 on page 20 Establishing communication with the Innohome Smart Socket The communication link between the Intelligent Heat Sensor and the Smart Socket starts au tomatically Occasionally devices that use X10 transmission may interact with the Smart Sock et In this case change the house address of the Smart Socket manually see the Smart Socket user manual STOVE GUARD SGK500 USER MANUAL 4 Intelligent Heat Sensor Installation cont Return to factory settings This may be required if you change your cooker to a new one Press the push button located inside a hole on the bottom surface of the Sensor and hold it down for a couple of seconds using a screwdriver see image 7 on page 20 Then press the Sensor cover do
11. automatic fault diagnosis alarm can also be triggered by the Intelligent Heat Sensor not being in its original installation location or if the Sensor has not been installed correctly First turn all cooker knobs to 0 then turn off the electricity for around 15 seconds using the main switch Ensure that the Intel ligent Heat Sensor is in its original installation location If the prob lem persists contact the product retailer Control Unit two short beeps after turning the Safety Lock off The Safety Lock has been turned off and the electricity reconnected to the cooker The cooker can now be used Control Unit a signal every hour or half hour There has been an error in the identifica tion of the cooker Repeat the setup procedure as described in section 11 under the heading the Control Unit signals every hour or half hour 1 5 Sensor Dislocation Alarm The Sensor Dislocation Alarm ensures that the Intelligent Heat Sensor is not accidentally re moved from its location If the Sensor is removed it will sound an alarm and the Control Unit will turn the cooker off To restore normal operation of the cooker return the Sensor back to its place and press the cover once If the Sensor cannot be returned back to its place the alarm can be reset by switching the Con trol Unit power off for a moment using the main switch After this the cooker can be used for 30 45 minutes when
12. cannot be reset and the cooker is turned off If the cooker has been turned off by the fault diagnosis the Control Unit carries on signalling the fault alarm signal it can be turned back on by first turning all cooker knobs to 0 then by turning the electricity supply off for 15 seconds using the main switch If the fault diagnosis has detected a problem first make sure that the Intelligent Heat Sensor is in its original instal lation location If the automatic fault diagnosis carries on detecting a problem contact the product retailer For gas dual fuel cookers Refer to the gas kit manual 1 7 Additional devices With the Innohome Smart Sockets additional signalling devices can be joined to the system or the Stove Guard can be set to automatically operate the extractor fan Several additional signalling devices such as flashing light or vibrating alarms can be linked and placed around the house The extractor fan can be set to automatically turn on when the cooker is used and to turn off if the Stove Guard alarm is triggered The Control Unit has an external alarm output that enables the alarms to be transferred to social alarm systems such as Telecare The Intelligent Heat Sensor outlook can be changed with optional colour covers See more detailed information about using and installing additional devices from www innohome com 2 Monthly Maintenance Electric cookers Since the automatic fault diagnosis tests the Stove Gu
13. e Intelligent Timer will turn the cooker off after one minute s time By pressing the Intelligent Heat Sensor cover once you will get more time to use the cooker If the Safety Lock has locked the cooker you can get it back in use by pressing the Intelli gent Heat Sensor cover once Stove Guard features a Overheating Monitor The Intelligent Heat Sensor installed above the cooker reacts to a dangerously high temper ature or steep temperature rise Several sensors with self adjusting programming detect tem perature and its change The Sensor learns the users cooking styles making hazard recogni tion precise with no false alarms The rate of temperature increase alarm is based on the steep temperature rise that happens when the cooking vessel s liquid has dried out Reacting to the temperature rise allows for an early detection and prevention of fire risk situations The Intelligent Heat Sensor will first sound a one minute long pre alarm signal see Intelligent Heat Sensor pre alarm signal on previous page after which the cooker is turned off Reset ting the pre alarm signal causes the Intelligent Heat Sensor to become less sensitive The Intelligent Heat Sensor alarm is also reset automatically in about two minutes after the cooker has been turned off and the temperature starts to drop After automatic alarm reset the cooker is turned back on normally first turn all cooker knobs to 0 then press the Intellig
14. e sound still triggers a false alarm When a false alarm is no longer triggered then make sure that the Stove Guard still responds to the alarm signals of external alarms by re testing the Alarm Signal Detection feature as advised in section 6 2 e Itis also possible to disable the Alarm Signal Detection feature see section 4 Disabling the Alarm Signal Detection feature Sometimes when a burner is on a low heat setting the cooker lights shut down for a cou ple of seconds e This is a normal function of the Stove Guard In electric cookers with mechanical knobs except cookers with a clock when a burner is turned on a very low heat the Stove Guard performs a check every 15 minutes to see if the cooker is still being used STOVE GUARD SGK500 USER MANUAL 11 Troubleshooting cont The Safety Lock did not activate within 20 minutes Check the setting of the Control Unit as advised in section 8 If the Safety Lock was not activated redo the setup process as described in section 5 Intelligent Timer did not cut off the electricity supply in 3 hours In some cookers that are operated by touch or that have a clock and with the SGK500 3 model in all electric cookers the Intelligent Timer will not start when a hotplate is on a very low setting What to do when changing the cooker to a new one e lf your hob type has changed ie you used to have an electric cooker and now you have a dual fu el cooker with gas burners change the
15. el in all electric cookers the Intelligent Timer does not necessarily start if the burner is on a very low heat setting Gas and dual fuel cookers timer The timer has a fixed time and starts when the hob tempera ture starts to rise The cooker is turned off after two hours in some dual fuel cookers the oven is not turned off Before the cooker is turned off The Control Unit will emit a one minute long pre alarm signal see Control Unit pre alarm signal on previous page Resetting the pre alarm signal will give two hours more time c Alarm Signal Detection fire carbon monoxide and gas alarms The Stove Guard identifies external fire carbon monoxide and gas alarm signals using sound detection An alarm signal emitted by an external alarm triggers the Stove Guard to turn the cooker off in some cookers the oven is not turned off d Cooker knob Safety Lock The Safety Lock can only be used with the SGK500 2 model and only on electric cookers with mechanical knobs excluding cookers with a clock The Safety Lock locks the cooker so that it cannot be turned on accidentally for example by a child a person with memory disorders or a pet To use the cooker press the Intelligent Heat Sensor cover once or turn one of the cooker knobs on and off three times at one second intervals on off wait one second on off wait one second on off The Control Unit emits two signals as the cooker is ready for use The cooker is
16. ent Heat Sensor cover once In cookers that are operated by touch the electricity supply is returned automatically burners are off after the electricity cut off STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it cont N B The Overheating Monitor alarm is not triggered if the hob s temperature is too low for a hazardous situation to be identified or if the cooker automatically limits a temperature in crease When the alarm has been reset manually it cannot be triggered by the rate of temper ature change for 30 minutes but can still be triggered by the heat level The Stove Guard is an additional safety device that does not necessarily cover all possible hazardous situations but does significantly improve cooker safety b Intelligent Timer Electric cookers The Intelligent Timer identifies a burner that has been accidentally left on by monitoring burner heat adjustments If a burner has been left on the cooker is turned off within a time period between 30 minutes and 3 hours depending on the burner setting the higher the setting the sooner the cooker is turned off in some cookers the oven is not turned off Before the cooker is turned off the Control Unit will emit a one minute long pre alarm signal see Control Unit pre alarm signal on previous page Resetting the pre alarm signal will restart the Timer Note that in some cookers that are operated by touch or have a clock and with the SGK500 3 mod
17. f the situation is not haz ardous press the Intelligent Heat Sensor cover once during the pre alarm signal The Stove Guard will learn that this kind of situation is a normal cooking situation When the cooker has been turned off and the Stove Guard is signalling first turn all cooker knobs to 0 then press the Intelligent Heat Sensor cover once In cookers that are operated by touch just press the Intelligent Heat Sensor cover once STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it cont 1 2 Structure of the Stove Guard The Stove Guard is composed of an Intelligent Heat Sensor attached underneath the cook er hood on the wall or on the cooker panel and a Control Unit connected to the cooker With the additional Innohome Smart Socket various distance alarms like flashing lights or vibrating alarms can be linked to the system or the Stove Guard can be set to automatically operate the extractor fan The Intelligent Heat Sensor the Control Unit and the Smart Socket communicate using a radio connection The Stove Guard can also be used with gas and dual fuel cookers with the additional gas in stallation kit including an electric valve fitted into the cooker gas supply The Control Unit has an alarm output that enables the Stove Guard to be linked to social alarm systems such as Telecare The Intelligent Heat Sensor outlook can be changed using optional colour covers The whole Intelli
18. gent Heat Sensor cover during the Intelligent Heat Sensor pre alarm signal see section 1 3 If the Intelligent Heat Sensor is installed to a cooker hood that is higher than 65 cm 26 for electric burn ers or higher than 70 cm 28 for gas burners or if one wants to pre adjust the sensitivity to a certain level when used in supported housing for example set the sensitivity level manually Electric bun ers see recommended sensitivity level from the table below Gas burners see the table in the gas installation kit manual Note that when the Intelligent Heat Sensor is installed on the wall it needs to be attached at the height of approx 40 cm 16 for electric burners 65cm 26 for gas burners cm 120 90 80 70 60 50 40 30 inch 39 35 32 28 24 20 16 11 level 1 2 3 4 5 6 8 16 Electric burners sensitivity level The grey area indicated in the table 30 65 cm 11 26 shows where manual setting of the sensitivity level is not required unless it is pre adjusted to a certain lev el The level is indicated by the numbers 1 to 16 where 1 represents the most sensitive level and 16 the least sensitive The factory setting is 5 Setting the sensitivity level manually 1 Detach the Intelligent Heat Sensor if attached with screws see Detaching an Intelligent Heat Sen sor attached with screws in section 4 Mark the Sensor original installation location if necessary Press the Intelligent Heat Sensor cover
19. gent Heat Sensor cover works as a push button but it is recommendable to press it at the point of the round light 1 Pressing the cover resets the alarm reconnects the gas electricity supply to the cook er and turns off the Safety Lock Green light 2 lights up at one minute intervals and when the Sensor is being pressed During an alarm a red light flashes Solar panels 3 power the Sensor Distinguishing the Stove Guard type Stove Guard SGK500 2 includes a Control Unit SGC500 2 with one blue connector SGK500 3 includes a Control Unit SGC500 3 with two white connectors STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it cont 1 3 Stove Guard use and features Stove Guard use When the cooker has been turned off and the Stove Guard is signalling first turn all cook er knobs to 0 then press the Intelligent Heat Sensor cover once In cookers that are operated by touch just press the Intelligent Heat Sensor cover once An Intelligent Heat Sensor pre alarm signal that has a short sound and a long break ___ ___ sounds one minute before turning the cooker off If the situation is not hazard ous press the Intelligent Heat Sensor cover once during the pre alarm signal The Intelligent Heat Sensor will learn that the situation was not hazardous A Control Unit pre alarm signal sounds from behind the cooker that has a short sound and along break ___ ____ indicates that th
20. ing styles of the user s If you are not certain whether the level was pre set set the level again see section 9 Ifthe Intelligent Heat Sensor still does not work contact the product retailer The Control Unit emits a short signal followed by a long signal be beep at approxi mately 5 second intervals e The automatic fault diagnosis has detected that the Intelligent Heat Sensor is not in its original installation location or that there is a problem in the connection between the Intelligent Heat Sensor and the Control Unit or in the functioning of some part of the system The fault diagnosis alarm can also be triggered by the Intelligent Heat Sensor not being installed correctly To turn the cooker back on first turn all cooker knobs to 0 then turn the electricity off for about 15 seconds using the main switch STOVE GUARD SGK500 USER MANUAL 11 Troubleshooting cont e Ensure that the Intelligent Heat Sensor is in its original installation location Ifthe automatic fault diagnosis carries on finding a problem contact the product retailer The Control Unit signals every hour or half hour e There has been an error in the identification of the cooker Repeat the setup procedure in the following manner 1 Turn the electricity off for 15 seconds using the main switch 2 Let the elec tricity be on for 5 seconds 3 Turn the main switch off again for another 15 seconds After turning the electricity back on the C
21. l smoke carbon monoxide and gas alarms need to be installed within 5 metres distance of the Stove Guard Control Unit After installation test alarm signal detection as ad vised in section 6 2 6 Testing after Installation 6 1 Intelligent Heat Sensor test Turn a burner on Press the Intelligent Heat Sensor cover and hold it down until you hear a signal The Control Unit will turn the cooker off by cutting its gas electricity supply and start to emit a signal To turn the cooker back on first turn the burner off not required in cookers that are operated by touch then press the Intelligent Heat Sensor cover once 6 2 Alarm Signal Detection test Turn the smallest burner to medium heat and test the fire carbon monoxide and gas alarms one at a time When the Control Unit detects an alarm signal it turns the cooker off and starts to emit a signal To turn the cooker back on first turn the burner off not required in cookers that are operated by touch then press the Intelligent Heat Sensor cover once The Stove Guard is factory set to identify most alarm signals If the Stove Guard does not react to the external alarm signal adjust the signal recognition frequency as advised in Troubleshooting section 11 6 3 Safety Lock test if activated during the installation Make sure the hob is turned off In approximately 20 minutes the Safety Lock locks the cook er Test the Safety Lock by trying to turn the burners on one by
22. locked 20 minutes after last use The Safety Lock feature can be activated or deacti vated by carrying out the Control Unit setup see section 5 STOVE GUARD SGK500 USER MANUAL 1 Innohome Stove Guard and how to use it cont 1 4 Meaning of alarm signals The Intelligent Heat Sensor signal has a higher tone than the Control Unit signal The Intelligent Heat Sensor is attached above the cooker the Control Unit signal sounds from behind the cooker Sound Intelligent Heat Sensor a short beep every few seconds e e e e Meaning The Intelligent Heat Sensor has identified a high temperature or a steep tempera ture rise above the cooker Overheating Monitor This is the Intelligent Heat Sensor pre alarm signal that is emitted one minute before the cooker is turned off Reset the pre alarm signal if it was triggered by a normal cooking situation this will cause the Intelligent Heat Sen sor to reduce its sensitivity automatically and will prevent the cooker shutdown Course of Action Press the Intelligent Heat Sensor cover once during the pre alarm signal Intelligent Heat Sen sor repetitive fast beep beep beep The Intelligent Heat Sensor has identified a high temperature or a steep tempera ture rise above the cooker Overheating Monitor alarm the cooker has been turned off First turn all cooker knobs to 0 then press the Intelligent Heat Sensor cover once In cookers that
23. off and then back on using the main switch An empty battery in the Intelligent Heat Sensor does not affect the safety features of the Control Unit 4 Intelligent Heat Sensor Installation 1 Remove the Intelligent Heat Sensor from its packaging and allow about 15 minutes for it to reach room temperature 2 The Intelligent Heat Sensor uses different settings for electric and gas burners Carry out initialization as described below depending on hob type If later you wish to change the hob type setting see Changing the hob type setting section 7 Electric burners Remove the installation plate 1 see image on next page that covers the bottom of the Intelligent Heat Sensor by lifting it up Lifting up the installation plate will also bring up the battery disconnection piece 2 see image on next page connecting the battery The Intelligent Heat Sensor will emit a signal signifying that the battery is connected Initialize the Intelligent Heat Sensor by pressing the cover once Save the battery disconnection piece for possible later use Gas burners Remove the installation plate 1 see image on next page that covers the bot tom of the Intelligent Heat Sensor by lifting it up Lifting up the installation plate will also bring up the battery disconnection piece 2 see image on next page connecting the battery The Intelligent Heat Sensor will emit a signal signifying that the battery is connected Take the Intelligent Heat Sensor
24. once 2 Put the battery disconnection piece into the hole on the bottom surface of the Sensor 2 see im age on page 9 Place the Sensor on top of a metallic surface eg a cooker bottom downwards for about five seconds 3 Remove the battery disconnection piece The Intelligent Heat Sensor will emit one or two signals one if the Sensor has electric burners setting two if gas burners setting Save the battery discon nection piece for possible later use 4 Put the Sensor back to its original installation place unless it is attached with screws in which case put it on a metallic surface eg a cooker 5 Press the Intelligent Heat Sensor cover for about five seconds until you hear a signal 6 Release the cover and press it again until you hear a signal 7 Press the cover as many times as is the sensitivity level you want to adjust the Sensor to Wait that the Sensor light turns off before pressing again 8 The Intelligent Heat Sensor will now emit twice as many signals as is the sensitivity level it has been set to and a third signal X that gives information to Innohome technical staff The signals are given in three lots 2 2 X for level 2 3 3 X for level 3 4 4 X for level 4 and so on STOVE GUARD SGK500 USER MANUAL 10 Alarm output The alarm output is a 3 5 mm stereo jack found on the Control CN1 Unit The alarm output is potential free and normally open y Alarm opto It closes for one second when the Control Unit cut
25. ontrol Unit will emit a signal signifying that the setup has been com pleted Then carry out the Safety Lock activation deactivation if applicable only SGK500 2 in electric cookers with mechanical knobs excluding cookers with a clock Activation Turn any of the hot plates on for 5 seconds then turn it off Wait until you hear a signal Deactivation Turn a hotplate on wait until you hear a beep from the Control Unit then turn it off The Control Unit did not identify the alarm signal of the fire CO gas alarm e Clean the alarm with a vacuum cleaner e Change the batteries in the alarm if necessary e Check that the alarm is not located too far from the Control Unit The alarms should be located at a maximum distance of 16 5ft 5 metres Frequency adjustment e Adjust the signal recognition frequency by turning the trimmer on the Control Unit using a screwdriver frequency adjustment see the picture Turn the trimmer slowly between tests until the Control Unit identifies the signal The Control Unit responds to other sounds e g a telephone ringing or noise from a tele vision Change the telephone ring tone or turn down the volume on the television If the signal that causes the false alarm cannot be disabled adjust the signal recognition frequency by turning the trimmer on the Control Unit using a screwdriver frequency adjustment see picture above turn the trimmer slowly approx 0 5mm at any one time then see if th
26. s the out NO cooker s gas or electricity supply If the alarm output does not work properly change the polarity of the cable connecting to the alarm output 11 Troubleshooting The cooker has been turned off and no signal sounds e The Control Unit overheating protection has turned the Control Unit and the cooker off This has probably happened due to a wrong installation place that becomes apparent when the cooker is used on a high power setting The cooker can be turned back on by turning the electricity off for a moment using the main switch If the overheating protection turns the cooker off again change the Control Unit installation location to a cooler one or to one that has better ventilation The Intelligent Heat Sensor alarm sounds in a non hazardous situation When the Intelligent Heat Sensor is first installed it needs to adjust to the kitchen environment and learn the users cooking styles If the Intelligent Heat Sensor starts to signal in a normal cook ing situation press the Sensor cover during the pre alarm signal This will cause the Intelligent Heat Sensor to reduce its sensitivity automatically The Intelligent Heat Sensor does not signal when it should If the Intelligent Heat Sensor is installed higher than 65 cm for electric burners or higher than 70 cm for gas burners the sensitivity level needs to initially be set to a more sensitive level after which it will sef adjust to the environment and to the cook
27. talled on the wall or if the cooker has a panel on the back on the cooker panel Install the Sensor on the wall using screws see instructions be low at the height of approx 40 cm 16 above the cooker for electric burners 65 cm for gas burners The Sensor is installed on the cooker panel using a bracket available separately 4 The sensitivity level is factory set to suit most installations However if the Intelligent Heat Sensor is installed higher than 65 cm 26 for electric burners or higher than 70 cm 28 for gas burners or if one wants to pre adjust the sensitivity level to a certain level when used in supported housing for example set the sensitivity level manually section 9 Opening and closing the Intelligent Heat Sensor cover see images 1 2 page 19 1 Detach the cover using a screwdriver carefully lifting from both ends one end at a time so that the cover gets unlocked image 1 2 Push the screwdriver a little bit further and open the cover using it as a lever image 2 To put the cover back put both ends in at the same time Make sure that the black round sen sor fits into the opening on the cover Attaching the Intelligent Heat Sensor using screws see images 1 3 page 19 1 Open the Intelligent Heat Sensor cover according to instructions see above 2 Attach the Sensor to the wall with screws as shown in the image image 3 3 Close the cover according to instructions see above S
28. the Control Unit setup button 1 until you hear a signal then release the button and press it again until you hear a signal After a short moment the Control Unit will emit another signal which signifies that the Stove Guard setup has been completed Electric cookers with mechanical knobs when you want to activate the Safety Lock Press the Control Unit setup button 1 until you hear a signal then release the button and press it again until you hear a signal If you hear two signals when releasing the button the Safety Lock has al ready been activated and you can finish here Turn any of the hotplates on for 5 seconds then turn it off Wait until you hear a signal to signify the end of setup time D STOVE GUARD SGK500 USER MANUAL 5 Control Unit Installation and Setup cont Electric cookers with mechanical knobs when you want to deactivate the Safety Lock Press the Control Unit setup button 1 until you hear a signal then release the button and press it again until you hear a signal or sometimes two signals depending on the previous setting Turn a hotplate on wait until you hear a beep from the Control Unit then turn it off External safety systems Telecare The Stove Guard is connected to an external system via the alarm output 2 see image above on the previous page More detailed instructions can be found from www innohome com External smoke carbon monoxide and gas alarms All externa
29. tton after which you can also release the cover The push button can also be pressed by putting the battery disconnection piece in to the hole and pressing it down The signals tell about the new hob type setting one signal signifies electric burners set ting two signals signifies gas burners setting 8 Checking the Control Unit settings The Control Unit settings can be checked by turning the power of the cooker off using the cooker switch the main switch and turning it back on after 15 seconds In gas cookers turn the power of the Control Unit off using the main switch or the socket switch The Control Unit will then emit signals to inform you about its settings SGK500 3 or BEEP 20 seconds break BEEP BEEP SGK500 2 in a cooker that has a clock or that is oper ated by touch BEEP BEEP 20 seconds break BEEP SGK500 2 in a cooker with mechanical knobs Safety Lock activated BEEP 20 seconds break BEEP SGK500 2 in a cooker with mechanical knobs Safety Lock deactivated BEEP 20 seconds break BEEP BEEP BEEP SGK500 2 in a gas cooker STOVE GUARD SGK500 USER MANUAL 9 Setting the sensitivity level of the Intelligent Heat Sensor The sensitivity level determines the level of heat and the rate of temperature change required to trigger an alarm The Intelligent Heat Sensor reduces its sensitivity automatically when the user presses the Intelli
30. wn and hold it until you hear three separate alarm signals Release the cover The Intelligent Heat Sensor has now been returned to its factory settings 5 Control Unit Installation and Setup If the cooker is connected to the mains electricity via a plug and a socket the Control Unit can be installed by the user In any other case the installation needs to be carried out by a qualified electrician Turn the electricity off at the main switch Attach the Control Unit to the wall using screws or adhesive tape near the electricity outlet and as close to the floor level as possible Attach the Control Unit so that the connectors are facing downwards Installation by the user connect the Control Unit between the cooker s plug and the socket Installation by an electrician connect the Control Unit to the cooker using an Innohome Junc tion Box or an Innohome Connection Cable Turn the electricity back on at the main switch The connection between the Intelligent Heat Sensor and the Control Unit will start automatically After approximately 5 seconds carry out the setup procedure described below note start the procedure within 30 seconds Cook ers that are operated by touch cookers that have a clock or when using the SGK500 3 model no setup procedure is needed The Control Unit will emit two signals after a moment meaning that the Stove Guard is ready for use Setup procedure and programming the Safety Lock Gas cookers Press

Download Pdf Manuals

image

Related Search

Related Contents

Powermate PM0545007 User's Manual  Philips Network Adaper User's Manual  Sony Psvac Usb Cable 22035 User's Manual  VPU3400 SOFTWARE USER`S MANUAL  Disappear - Dustbane  BassCube 8S/10S Manual  イオン照射研究施設等利用管理支援業務 民間競争入札実施要項(案)  EPSON PM-G700 プリンタ補足説明書  MANUEL D`ENTRETIEN PROFESSIONNEL  Toshiba Tecra R850-S8511  