1. CROW ELECTRONIC ENGINEERING LTD CSB 200 DIGILON Microwave barrier Outdoor Detector 200m Range INSTALLATION INSTRUCTIONS amp USER MANUAL P N 7111201 Rev C Y S A Y The CSB 200 is a bi station microwave detector for outdoor applications It comprise a transmitter T and receiver R which when mounted facing each other create a protected area with length up to 200m Width of the protected area vary according the distance between the two units and the selected system sensitivity The Microwave barrier CSB 200 is an advanced detector utilizing state of the art Microwave technology eliminating false alarms while maintaining high security standards for the detection of human intruders into a protected area The CSB 200 is designed to protect large part of protected perimeter and can easily be installed on any type of fence or pole in order to provide a solid barrier protection and block all perimeter activities this barrier rejects alarms from birds and small animals like a cat due to its original method of false alarm elimination Several CSB 200 systems can be combined in order to provide a complete perimeter protection with unlimited space or shape The CSB 200 is designed for continuous round the clock operation and keeps its characteristics within a wide temperature range of 40 C up to 65 C and a relative humidity of up to 98 Features e Detection Range Up to 200m e Operating Temperature 40 C to 65 C
2. The resulted installations and also thresholds of detection can be changed by means of the device of the control TIK PM 150 Manual regulation of the alarm signaler allows to provide functioning of the alarm signaler at some deviations of conditions of operation from requirements of the present management and also to lead updating of the alarm signaler characteristics proceeding from tactics of protection of concrete object THE CONTROL OF FUNCTIONING At inclusion of a feed in case of absence of movement in the zone of alienation the alarm signaler is established in an on duty mode during no more than 30 sec Thus output relay contacts of the alarm signaler are closed For control of functioning of the alarm signaler it is necessary to open a cover of the receiver unit connect the adjustment panel and to check the functioning of the alarm signaler as follows using instructions of the manual for the adjustment panel 1 To check the conformity of range of action defined by the alarm signaler to actual length of a site is recommended At discrepancy of range of action defined by the alarm signaler to actual length of a site or blinking of displayed value limiting values of an accepted signal that can be caused by nonfulfilment of any requirements of the present instruction or by wrong adjustment it is necessary to eliminate the revealed infringements at impossibility to execute manual adjustment of range of action range corresponding ac
3. e Power Input 10 2 30 Vdc e Detect human intruders walking running or crawling e Quick and easy installation on pole fence or wall e No maintenance required e High RFI EMI Immunity e Protection from direct sunlight wind up to 30 m sec snow and rain precipitation small animals ground swing snow and grass up to 0 3m e Making alarm when Human intruders walking running or crawling with speed from 0 1 till 10 m s applying 5 30 Volts from control unit to the terminal marked TEST on the transmitter unit power supply voltage less than 10 2 V transmitter 2 or receiver cover has been opened or destructed electromagnetic masking of the receiver Installation instructions Maximum lenght of protection zone Maximum width of protection zone Maximum hight of protection zone Instalation height 0 8 0 9 m Dead Zone Maximum depth of snow on the Maximum height of grass on the 1 5 2m ground 0 5 m ground 0 3 m Fig 1 Installation and Protection zone Mounting the detector Alarm LED Alarm LED shines for a while not less than 2 sec but no more than 30 SeC Protection LED dos not shine Power supply less than should be LED blinks with the period 2 sec 1 sec shines and 1 sec switched off invalid parameters of initial installation a level of an accepted signal less than 9 Db LED blinks with the period 2 sec 0 25 sec shines and 1
4. 75 sec switched off Fault LED on the control panel shines constantly Installation Installation on Pole Attention The reliability of alarm signaler work depends on the fulfillment of the following requirements By the no fulfillment of these requirements infringements of alarm signaler working capacity are possible In such cases the 3 question of an admissibility of alarm signaler application in the given conditions is defined by experimental exploitation In protection zone The maximal height of roughness s of a spreading surface concerning the direct line which is passing through the bases of R receiver and T transmitter support should not exceed 0 3 m Presence of bushes and branches of trees large motionless subjects and building constructions is not supposed The height of grass should not exceed 0 3 m At increase or reduction of snow thickness more than 0 3m respective alteration of height of R and T installation is necessary At excess of the height of a snow above 0 7m should be considered that alarm signaler can not find out the person moving in the thickness of a snow cover Movement of transport people and animals is not supposed The form and the sizes of protection zone depending on the distance between R and T are shown in the figure 2 The width of zone of alienation is counted under the formula W 1 L 50 m L 10 200 M Fig 2 By the choice of an installation site fo
5. Use metal or cement poles with a diameter of 90 100 mm as the support It is allowed to install two units on a single support the two units must be identical Two transmitters or two receivers Installation height of R and T units should be in a way that the bottom surface of the plastic housing will be 0 8 0 9m Very important above the top of surface ground and grass For pole installation use the two bands connected to the bracket and ensure reliable fastening of the bands The unused part of bands may be cut off Connect the plastic housing to the bracket using the nuts with the spherical support Top installation Alarm signaler installation on top of fencings for detection of overclimb is supposed Thus the height of installation of blocks should be not less than 0 2m 5 from the top of a fencing and not less than 2 m from the surface of the ground the maximal length of the protection zone should be no more than 100m the distance from the top of a fencing up to blocks across not less than 0 2m The immovability of the fencing and alarm signaler blocks concerning the fencing should be provided The ledges of fencings and walls should not block an axis of a protected zone In case of a deviation of a line of a protection from a straight line and also at presence of the ledges which are not overlap an axis of the protected zone on specification of installation site of T R can be demanded in the experimental way The not
6. amp 6 Marked TAMPER Connect these terminals to a 24 hour normally closed protective zone in the control unit If the front cover of the detector is opened an immediate alarm signal will be sent to the control unit F mode Jumper Setting of Frequency channel Factory setting OFF position CONTROL UNIT WIRING CONNECTIONS Receiver board 4 o olola i Control panel 12 24Vdc ALARM POWER 12 24Vdc BOARD Sale For normal closed 12 30 V alarm circuit Test button Transmitter Board eeel TEST TAMP Fig 6 Control Unit and CSB 200 Wiring Diagram 10 TEST AND TUNING Fig 7 CSB 200R Fig 8 CSB 200T Receiver unit Transmitter unit with binding with binding band For preliminary set up focus the receiver and transmitter facings to each other Make sure that the antenna s radiating surfaces of R and T are parallel radiating surface is perpendicular to the virtual direct line 1 Take off the cover from receiver R fig 7 and transmitter T fig 8 units At installation the alarm signaler provides Automatic definition of range and thresholds of detection Basic modulation frequency A range of detecting speeds from 0 2 up to 6 m s At preservation of the specified installations and fulfillment of requirements resulted in the section Installation the alarm signaler does not demand adjustments with use of any devices
7. the display If in these modes noises the 17 changes of the signal which has not been caused by the movement of a person in the protected zone are displayed it is necessary to arrange on the elimination of their sources see the control of functioning All the control crossings should be carried out with intervals not less than 20 sec with a speed from 0 5 up to 3 m s by a normal to an axis of a protected zone leaving from it on the distance not less than 2m The weight of the operator who is carrying out the crossings should be 50 80kg height in a grouping having bent from 0 8 up to 1m Thus the fulfillment of crossings in the following places is obligatory in the middle of a site in both positions in the distance from 15 up to 20m from receiving and transmitting blocks in both positions e in hollows in having bent position ATTENTION For increase of a noise stability of the alarm signaler it is necessary to establish probably greater thresholds of operation Test procedure Walk Test After tuning the sensitivity connect 12 or 24 V DC power to the system Allow 2 minutes warm up time Make sure that the protected area is cleared of all people Cross the middle part of the protected area An alarm signal should be received in the control unit for 3 Sec NOTE Walk Test procedure should be conducted at least once a year to confirm proper operation and coverage of the detector 18 Remote Test Ap
8. vidicon pl CROW LATIN AMERICA 5753 NW 151 Street MIAMI LAKES FL 33014 USA Tel 1 305 823 8700 Fax 1 305 823 8711 E mail sales crowlatinamerica com DEATRONIC VIA Giulianello 4 14 00178 ROMA ITALY Tel 39 0676 12912 Fax 39 0676 12601 E mail info deatronic com 7111201_C 22
9. al coated circuit board Specifications are subject to change without prior notice CROW ELECTRONIC ENGINEERING LTD Crow WARRANTY POLICY CERTIFICATE This Warranty Certificate is given in favor of the purchaser hereunder the Purchaser purchasing the products directly from Crow or from its authorized distributor Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products hereunder the Warranty Period Subject to the provisions of this Warranty Certificate during the Warranty Period Crow undertakes at its sole discretion and subject to Crow s procedures as such procedures are form time to time to repair or replace free of charge for materials and or labor products proved to be defective in materials or workmanship under normal use and service Repaired products shall be warranted for the remainder of the original Warranty Period All transportation costs and in transit risk of loss or damage related directly or indirectly to products returned to Crow for repair or replacement shall be borne solely by the Purchaser Crow s warranty under this Warranty Certificate does not cover products that is defective or shall become defective due to a alteration of the products or any part thereof by anyone other than Crow b accide
10. block is not control device is serviceable absent The alarm signaler Circuit OUT is To check up integrity of circuit OUT constantly gives out broken by procalls To check up the notice on circuit OUT indication at connection of the correctness of installation of a terminal element of the control The receiving To replace the receiving block control device block is not corresponds to serviceable normal functioning 3 The alarm Circuit TAMPER To check up integrity of circuit signaler constantly is broken TAMPER by pro calls To check up gives out the notice correctness of installation of a on circuit TAMPER terminal element of the control device Wrong To check correctness of installation installation of a cover of one of blocks of covers 4 The alarm signaler constantly gives out the notice on circuit OUT the control device in a mode of indication of notices gives out the message AUT The pressure of a feed is less than norm To check the pressure of a feed of the switched on alarm signaler to check up circuits of a feed and a power unit 15 5 The alarm signaler constantly gives out the notice on circuit OUT on the control device is constantly shone the message A 6 Frequent false notices Discrepancy of installation or conditions of operation to requirements of the present management To estimate visually the correctness of
11. e At the installation of alarm signaler along constructions or on top of protections manual adjustment of thresholds is recommended The support should be mechanically connected to the fence to ensure reliability NOTE It is necessary to exclude a drain of water from a roof closer than 5 meters from an axis of a zone of detection Cross installation In order to avoid dead zones under aerials and to increase the protected area it is possible to install multiple CSB 200 systems connected together with overlapping Overlap configurations are performed with the units located at the angles of protected area The minimum overlap for sufficient coverage must be at least 1 5 2m depending on the sensitivity set and installation height The optimal way is to install transmitters T only or receivers R only at the point of overlap D eS PON O ene PRK BRR RKO RKO y ORIS ROO ROKK RRQ Fig 2 Overlap installation of2 systems to avoid blind zones e e CS ee Z Transmitter Fig 4 Overlapping Angle and Range Receiver Receiver Transmitter Fig 3 Transmitter Transmitter Transmitter Receiver Overlapping Installation of multiple CSB 200 systems 7 ww gece z Installation of CSB 200 systems for area pro
12. ection Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary fire robbery or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result Consequently Crow shall have no liability for any personal injury property damage or any other loss based on claim that these products failed to give any warning If Crow is held liable whether directly or indirectly for any loss or damage with regards to these products regardless of cause or origin Crow s maximum liability shall not in any case exceed the purchase price of these products which shall be the complete and exclusive remedy aqainst Crow 21 CROW ELECTRONIC ENGINEERING LTD ISRAEL USA AUSTRALIA POLAND LATIN AMERICA ITALY Crow Electronic Engineering Ltd 12 Kineret St Airport City P O Box 293 Ben Gurion Airport 70100 Tel 972 3 9726000 Fax 972 3 9726001 E mail support crow co il 2160 North Central Road Fort Lee N J 07024 Tel 1 800 GET CROW or 201 944 0005 Fax 201 944 1199 E mail support crowelec com 142 Keys Road Cheltenham Vic 3192 Tel 61 3 9553 2488 Fax 61 3 9553 2688 E mail crow crowaust com au VIDICON SP ZO O 15 Povazkowska St 01 797 Warsaw Poland Tel 48 22 562 3000 Fax 48 22 562 3030 E mail vidicon
13. ice at crossing of the protected zone it is necessary to execute the actions described in section Use of a product 5 To make the remote control in case of use of this function having submitted on the output TEST a pressure 5 30V thus the alarm signaler should give out the notice of alarm During the use of the alarm signaler it is recommended to realize a remote control each 8 hours To lead the approbation of the alarm signaler work by trial round the clock alarm signaler operation during the period not less than 3 days with registration of all notices and their subsequent analysis Thus not less than two times a day to make a check of the working capacity of the alarm signaler by control crossings of the protected zone 13 At revealing false notices at check or misses at control crossings it is necessary to eliminate infringements using instructions of section Use of a product 14 THE LIST OF THE BASIC POSSIBLE MALFUNCTIONS AND WAYS OF THEIR ELIMINATION External display The possible reasons of malfunction Ways and sequence of the definition of malfunction 1 The alarm signaler constantly gives out the notice on circuit OUT indication at The pressure of a feed does not move on the receiving block To check a pressure of a feed of the receiving block At absence to check up circuits of a feed and a power unit The receiving To replace the receiving block connection of the
14. installation and a conditions of operation on conformity to requirements of section installation To eliminate deviations at impossibility to lead adjustment The receiving block is not serviceable To replace the receiving block The transmitting block is not serviceable Discrepancy of installation or conditions of operation to requirements of the To replace the transmitting block To lead the control of functioning to estimate correctness of installation and conformity of conditions of operation to requirements of section installation To eliminate deviations present at impossibility to lead regulation management Influence of To lead the control of functioning and radiation of the transmitting block of the next site on the receiving block regulation Malfunction of the circuit TEST For revealing malfunction in the circuit TEST to disconnect circuit TEST from the alarm signaler and to lead control operation without use of mode TEST Instability or excess of a level of pulsations of a pressure of a feed To check up reliability of contact connections and correctness of a lining of circuits of a feed To check up serviceability of a power unit for what to lead control operation at a feed from obviously serviceable source 16 Malfunction of To short circuit with the crosspieces circuits OUT or the target circuits of the receiving TAMPER block and to lead the cont
15. nt abuse negligence or improper maintenance c failure caused by a product which Crow did not provide d failure caused by software or hardware which Crow did not provide e use or storage other than in accordance with Crow s specified operating and storage instructions There are no warranties expressed or implied of merchantability or fitness of the products for a particular purpose or otherwise which extend beyond the description on the face hereof This limited Warranty Certificate is the Purchaser s sole and exclusive remedy against Crow and Crow s sole and exclusive liability toward the Purchaser in connection with the products including without limitation for defects or malfunctions of the products This Warranty Certificate replaces all other warranties and liabilities whether oral written non mandatory statutory contractual in tort or otherwise In no case shall Crow be liable to anyone for any consequential or incidental damages inclusive of loss of profit and whether occasioned by negligence of the Crow or any third party on its behalf for breach of this or any other warranty expressed or implied or upon any other basis of liability whatsoever Crow does not represent that these products can not be compromised or circumvented that these products will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that these products will in all cases provide adequate warning or prot
16. ply 5 30 Volts from control unit to the terminal marked TEST on the transmitter unit An alarm signal should be received in the control unit for 3 Sec NOTE During regular operation it is recommended to conduct remote test every day to confirm proper operation of all system 19 SPECIFICATIONS Microwave Frequency 9 5 GHz Modulation Frequency 1 0 KHz Maximum Transmitting Power 35mW Continues 50mW Peak Scope Length of protection zone Max 200 m Lobe Width Approx 5m Lobe Height Approx 2 5 m Rated Power Supply Voltage 12 24V Range of Power Supply Voltage 10 2 30 V Current consumption 70 mA at 24 Vdc Relay contacts values N C 28 Vdc Maximum current 0 1 A Alarm Period 3 Sec Max Tamper Switch N C 28 Vdc Maximum current 0 1 A open when cover is removed Detection Speed Target velocity 0 1 10 m sec Remote testing Built in self test generator simulates actual intrusion signals Flatness of ground Approx 0 3 m Maximum height of grass on the 0 3m ground Maximum height of snow on the jm ground Alarm output switching over of relay contacts for the time Minimum 3 Sec Dimensions of unit Trans Rec w o bracket 158 x 113 x 46mm Weight T R and accessories 1 1Kg Operating temperature range 40 C 65 C Weatherproofing e All openings with gasket and sealed e Conform
17. r exception of influence of interference at the alarm signaler work following recommendations should be considered in addition eRoutes of movement of groups of people up to three person or cars in A case of movement along a site presence of mobile subjects and designs including large forests are supposed on the distance not closer than 2 m from the borders of protection zone eDistance from borders of protection zone up to motorways with intensive movement and railways there should not be less than 3 m eSites of blocks installation should be removed from electric main wires in the distance not less than 20 m at a pressure up to 35 kV and 30 m ata pressure up to 500 kV By their arrangement in parallel with electric mains it is recommended to lay connecting lines in the underground way Installation of the alarm signaler along flat surfaces of constructions fencings and walls of buildings is supposed Thus roughnesses of these surfaces should not exceed 0 3m Distance from the surface of these constructions up to installation sites of the alarm signaler blocks should be from 0 6 up to 1 2m It is necessary to consider an opportunity of overcoming of a protected zone by a jump from these constructions to exclude a drain of water from a roof on distance up to 5 m from blocks of alarm signaler on an axis of a protected zone Requirements to a site outside radio opaque metal reinforced concrete etc obstacles are not shown
18. rol operation Thus the false notices registered by the control device are an attribute of malfunction OUT TAMPER or the control device itself The receiving or To replace the alarm signaler the transmitting block is faulty block not serviceable The note Malfunction of the alarm signaler blocks is revealed by their replacement by obviously serviceable ones with the subsequent control operation Alarm signaler regulation By means of the control device it is possible to check and change e Formation of notices on alarm and voltage reduction of a feed Alarm signaler operating mode e Borders of speeds of found out crossing of a protected zone e Level of an accepted signal Range of action e Thresholds of detection The order of using of the control device is described in the instruction on the control device The technique of regulation of the detection thresholds is adduced below For the control and change of small and positive thresholds it is necessary to connect the control device to the alarm signaler and to choose a corresponding mode In the verification modes and modes of change of small and positive thresholds in the bottom line of KKN for convenience of adjustment is displayed a conditional scale on which value of a threshold symbol value of a signal symbol the operation of the block of small or positive threshold is signaled by a symbol in the right bottom corner of
19. tection TERMINAL BLOCK CONNECTIONS Fig 5 PCB Layout C ai e O oloo Q o2 2 O A sgo Vout rawper 2 oo Alarm LED Terminal Block Test Connector Frequency Jumper Tamper switch Receiver Board LED lolll 12V OUT TAMP Terminal 1 Marked 12V Connect to a positive Voltage output of 12 30Vdc source usually from the alarm control unit Terminal 2 Marked 12V Connect to the negative Voltage output of the control unit Terminals 3 amp 4 Marked OUT These are the output relay contacts of the detector Connect to normally closed zones in the control unit Terminals 5 amp 6 Marked TAMPER Connect these terminals to a 24 hour normally closed protective zone in the control unit If the front cover of the detector is opened an immediate alarm signal will be sent to the control unit Frequency Jumper Setting of Frequency channel Factory setting OFF position a8725 001 Terminal Black ollaaa 12V TEST TAMPER Terminal 1 Marked 12V Connect to a positive Voltage output of 12 30Vdc source usually from the alarm control unit Terminal 2 Marked 12V Connect to the negative Voltage output of the control unit Terminal 3 Marked 12V Terminal 4 Marked TEST The alarm signaler makes alarm during the test signal 5 30 Volts from alarm station feeding in this terminal Terminals 5
20. tual should be established positive and small thresholds by a technique resulted in the section Regulation of the alarm signaler 2 To specify the adjustment of blocks for what it is necessary to establish preliminary a corresponding mode of the control device a mode of adjustment and to weaken the nuts of fixing of blocks Then smoothly turning serially transmitting and receiving blocks to achieve a maximum level of an accepted signal is recommended The blinking of numerical value of an accepted signal at small length of protected area arises at a signal more than 66 Db thus follows to deregulate the transmitting or receiving block having directed it a little upwards that displayed value was within the limits of 62 65 Db The blinking of the numerical value of an accepted signal at the big length of protected area arises at a signal less than 10 Db thus if it is impossible to increase an accepted signal by specification of adjustment by reductions of a site according to the requirements of the present instruction or by change of an installation site of blocks the decision on an admissibility of alarm signaler application in the given conditions is defined by the experimental exploitation It is necessary to consider that in some cases at adjustment the maximum level of an accepted signal is reached in the 12 direction of blocks aside nearby reflecting surfaces fencings the surface of the ground etc In such cases adjustment
21. with use of the device of the control is not supposed In case if thus the device of the control displays noise the changes of the signal which has not been caused by the movement of a person in the protected zone it is necessary to arrange on the elimination of their sources at impossibility to change an installation site to reduce the extent of a site Such noises having usually casual acyclic character can be caused by movement of subjects the vegetation shaking on the wind Other probable reason of the noise having regular periodic character can be the influence of radiation of the next sites transmitters on the reception block The revealing of such influence is made by switching off of a feed of the next transmitting blocks At revealing of the influence it is necessary to change frequency of alarm signaler modulation having removed the corresponding crosspiece on the transmitting block and having changed the value of frequency on spare by means of the control device 3 To change the range of detecting speeds if necessary Desired value borders of detecting speeds are defined by service of operation proceeding from features of the object a protected site and tactics of protection 4 To check necessarily by means of the control device formation of notices on alarm for what to execute control crossings of zone of alienation on all length of a site choosing places of passes in hollows on eminences In case of the absence of the not

Download Pdf Manuals

image

Related Search

Related Contents

DUO DIVISYS  Four à vapeur combiné EEBD 6600.2 Mode d`emploi  here - RAD Software  05-03 CP TRACEDOG  Westinghouse 7247800 Installation Guide  Digitus DN-19 ORG-SRV-42U-SW rack accessory  Manual do Usuário Nokia C2-00  AGXV-541 L V M P 自動ガン 取扱説明書  Graco 8840 User's Manual  AF-310 - Air Conditioner Home  