1. No 5011570 J MORITA MFG CO Za J Operation 2008 04 21 38 Service For Morita CP4 O WO and CP5 O Coupling One way Spray Valve Coupling Gasket Coupling Wrench for 4H and 5H O ring Set for 4H and 5H No 5811837 CP4 No 5811838 No 5011831 No 5811835 CP5 No 7911823 SD lt Operation 2009 09 24 J MORITA NV Capsule Cartridge Replacement Replace the Capsule Cartridge if worn ball bearings result in poor or irregular rotation if burs are difficult to insert or remove or if the chuck loses it gripping power The Capsule Cartridge and its O ring wears out and must be replaced periodically The bearings and other parts wear out and make more noise after a certain period of time ANWARNING If used in this condition a bur or point could come out inside the oral cavity and injure the patient or be swallowed ANOTE Do not fail to use the Capsule Cartridge for the PAR 4HEX PAR 4HX and the PAR 4HMX Operation 2008 04 21 40 Service Remove old Capsule Cartridge Cap Screw Cap Check for the PAR 4HEX PAR 4HX PAR 4HMX marking T Capsule Cartridge Take the cap screw out with the screwdriver Operation 2008 04 21 J MORITA MFG CORP Push For PAR 4HEX O Out PAR 4HMX O For PAR 4HX O SSS Fit the cap tool securely onto the cap guide and take the cap Push the old cartridge out by pressing the aero skirt around the
2. Operation 2008 04 21 Maintenance Maintenance Burs and points may get stuck in the handpiece if they are lt Cleaning gt left in for too long Always remove the bur or point after finishing treatment oe lt Disconnect gt Disconnect the handpiece from the tube Remove the point or bur Use the brush and running water to clean the handpiece RAQYBITA Operation 2008 04 21 J MORIT Maintenance Clean Spray Hole If a spray hole gets clogged with impurities in the water clean it in the following way Spray Hole Wire Use the wire provided to clean out the spray hole J MORITA MF G CORP Syringe Nozzle After cleaning blow the hole out with a syringe and wipe the handpiece with gauze dampened with Ethanol for Disinfection Ethanol 80 vol f Operation 2008 04 21 Maintenance lt Disinfection gt Use a piece of clean gauze and brush to disinfect the whole surface of handpiece with Ethanol for Disinfection Ethanol 80 vol Operation 2008 04 21 J MORITA MFG CORP Maintenance Thermal washer disinfector LJ Handpieces with this symbol may be cleaned and disinfected with a thermal washer disinfector To use a thermal washer disinfector first read the operation instructions for the unit Strictly follow the instructions attached for cleaning mode and solution MANN i Improper cleaning modes and solutions will damage the handpiece MI d if 3 D Operati
3. Me mOxe ai c Yal cy Introduction 000 0 ceeeecccecccececeeeeeeeceeeceaeeaseeeeeeseeaueaenens 1 Parts Identification and Accessories 5 Operation eccceeceesceeeeeceenaeeeeeeeseaeeceaeeeeaaeeneeeesaeenaes 8 Handpiece Attachment eeen 8 Inspecting and Sterilizing before Use 11 Burs and Points cccceseececeeeseeeeeeeeeeeeeseaneeeeees 12 Inserting and Removing Burs eceeeeeeeeeees 15 Maintenance ceeccccececeeeeeeeeeeeeeseeeeaeeeeeeenseanenes 20 After USE coe enacts ac inane 20 SIOMMIZAtI ON sxcene sfcccees cs secekccds cdc nc cxectbnn co ecete ss stnewecesecs 32 Operation 2009 09 24 ISI VICG 52 etic sacs EE E tere E ETE 34 Parts Replacement 0 0 0 cccececceeeseeeeeteenteeeeeeeees 34 Regularly Required Replacement Parts 63 Other Replacement Parts ccccecessseeeeeteees 63 BC orie a E A 63 Troubleshooting cccccceeeeeeecceeeeeeeeeeceeeeeeeeeeeee 64 Technical Information cccccccesseeeeeesteeeeeeeees 71 Specifications ccecccccecseceeeeeseeeeseeeeeeeeseeeeeeeeees 71 Terminology and Symbols ccesseeeeseteeeeees 75 Service and Other Contacts cc cccssseeeerees 76 Disposal of Medical Devices eeeeeeeeeeee ne 76 CP4 O W and CP5 O Coupling ceeeeeeee 77 Introduction Introduct
4. of the tube match the coupling Lamp voltage is correct This coupling cannot be connected to a tube that does not have light capability Water Spray Air Drive Air Exhaust Electrical Contacts CP5 O lt with Fiber Optic gt Coupling Before use check the following items Does the connection end of the tube match the coupling This coupling cannot be connected to a tube that does not have light capability This coupling cannot be connected to a 4 hole tube Spray Air Exhaust iL Operation 2009 09 24 CP4 O WO and CP5 0 Coupling CP4 O WO CP5 O CP4 0O lt with light gt CP5 0 lt with Fiber Optic gt Model CP4 WO lt with light and Spray Control gt ISO 9168 Type 3 Coupling ISO 9168 Typ amp 2 Coupling Weight 27 10g 27 10g Lamp Max 3 3 V 0 05 V D C Voltage for coupling contacts Lamp Max 2 4 W Power Lamp power supply must be conformed to IEC60601 1 and voltage is SELV special safe low voltage Operation 2009 09 24 VAN Xe i For the CP 4 the lamp will burn out more quickly if voltage is greater than the value specified For the CP 4 the lamp may burn out more quickly if the chair is set for a long fade out time For the CP 4 the lamp may burn out more quickly if the chair applies and cuts off the voltage suddenly CP4 O WO and CP5 0O Coupling 1 Connect Coupling Line up the projections on the coupling with
5. the indentations in the tube and then tighten up the cover nut AN Xe i Before connection make sure the tube connector is clean and free of debris The light will lose its brightness if the end of the fiber optic cable is scratched or otherwise damaged by being dropped for instance Operation 2009 09 24 CP4 O WO and CP5 0 Coupling VAN 0 i Air or water may leak if the coupling is not tightened up enough Tighten securely with the wrench provided Before first using the coupling or if the handpiece coupling connection gets stiff take the nozzle off the AR Spray can and lightly spray the coupling s o rings Operation 2009 09 24 CP4 O WO and CP5 O Coupling 2 Cleaning Wipe the outside cover with Ethanol for Disinfection Ethanol 80 vol NNO Coupling must NOT be autoclaved or cleaned ultrasonically The coupling could be damaged if it is soaked in Ethanol for Disinfection Ethanol 80 vol or cleaned with a strong corrosive solution Clean both ends of the light guide if the light seems to have lost its brightness Operation 2009 09 24 CP4 O WO and CP5 0 Coupling 3 Spray Adjustment CP4 WO Indicator Turning the dial in the direction indicated by the arrow in the illustration will gradually reduce the amount of spray and then reach 0 For maximum spray continue the turning the dial until the W matches up with the indicator See illustration Spray Con
6. wear out more quickly and lose its gripping power Always carefully remove all cleaning fluids before inserting a bur into the chuck some cleaning fluids are corrosive and if a bur or point with cleaning fluid on it is inserted the chuck could be ruined If a dirty bur or one with cleaning fluid on it has been inserted by mistake contact your local dealer or the J Morita Office to have the instrument inspected Carefully read the instruction manual of the bur maker Use only burs made of a single piece of metal do not use burs whose head is welded to the shank Welded joints break easily Operation 2008 04 21 Operation lt Insert gt sert in Insert Pra Hold down the Push Button Carefully insert the bur as far as it will go Hold down the push button firmly and push the bur all the way in then release the push button J MORITA MFG CORP Operation 2008 04 21 Operation Z WARNING Insert burs and points as far as they will go into the chuck Never operate the handpiece with a partially inserted bur or point A bur or point which comes out inside the oral cavity could seriously injure the patient or be swallowed GOOD BAD Operation 2008 04 21 J M O R a lt Removal gt Hold Down Operation ANWARNING After inserting a bur always operate the handpiece outside of the oral cavity to make sure it runs smoothly If a bur comes out during use stop operating the handpiece immediately Alw
7. with gauze insert the nozzle and spray for 2 or 3 seconds WE Operation 2009 09 24 J MORITA MFG CORP Maintenance NWARNING Lower or raise the nozzle all the way Otherwise oil could spray out and get in your eyes Make sure the lever clicks and locks into place Always cover the head with gauze before spraying inside the chuck If spray accidentally gets into your eyes wash them out with plenty of water and see a doctor Use soap and water to wash off any spray on your skin J MORITA MFG CORP Operation 2008 04 21 Maintenance lt Connect gt lt Operate gt lt Disconnect gt Connect the handpiece to its tube Operate the handpiece for about 15 Disconnect the handpiece seconds to blow out excess lubricant Operation 2008 04 21 J MORITA MFG CORP Maintenance lt Check Chuck s Gripping Power gt Carefully insert the chuck tester as far Firmly hold down the push button and Carefully pull on the tester until the as it will go push the tester all the way in then blue line appears release the button J MORITA MFG CORP Operation 2008 04 21 Maintenance If the Blue Line Appears Chuck is OK Blue Line Stop pulling if the blue line appears and let the tester slowly go back to its original position Hold the push button down firmly and take the tester out of the chuck Operation 2008 04 21 If the Blue Line Does NOT Appear Chuck has lost gripping power Clean the chuc
8. COR Technical Information Technical Information Name TWINPOWER TURBINE 4H Model with light Operation 2008 04 21 J MORITA MFG CORP Technical Information PAR 4HEX O PAR 4HX O PAR 4HMX O CP4OWO Ky WH SR NK CP4 OMWO Ky WH SR NK oo KV WH SR NK CP5 0 CP5 0 CP5 O Bearing Ball Bearing Chuck Push Chuck Rotor Autoclavable Capsule Cartridge Recommended Air Pressure 0 23 0 25 MPa Air Pressure Air Pressure Range 0 2 0 29 MPa at handpiece Water Supply Pressure 0 05 0 2 MPa connection Tip Air Pressure 0 2 minimum MPa Exhaust Air Pressure 0 03 maximum MPa Operation 2009 09 24 Technical Information PAR 4HEX O PAR 4HMX O cpso KV creo ad Speed rpm 370 000 30 370 000 30 Air Flow NL min Weight g 51 57 51 57 Head Diameter mm Head Height mm Length mm 120 115 120 115 Number of water spray nozzle Operation 2009 09 24 Technical Information Operating Temp 10 40 C Conditions Humidity 30 75 RH Atmosph Pressure 700 1 060 hPa Lamp Voltage Max 3 3 V 0 05 V D C for coupling contacts Lamp Power Max 2 4 W Lamp power supply must conform to IEC60601 1 and voltage is SELV special safe low voltage Operation 2008 04 21 NNO The handpiece will lose both speed and to
9. High Speed Air Turbine Handpiece TWINPOWER TURBINE 4H E mM lt with light gt PAR 4HEX O PAR 4HEX O KV WH SR NK Notice Of Protect Intellectual Prope PAR 4HX O PAR 4HX O KV WH SR NK GENE ieee fe PAT Bak PAR 4HMX O PAR 4HMX O KV WH SR NK CN PAT 03123632 4 JP PAT 3208345 DE PAT 19807566 JP PAT 3672781 DE PAT 19860953 JP PAT 3795722 DE PAT 10060152 JP PAT 3897953 DE PAT 10320902 JP PAT 4088475 Operation Instructions US PAT 0676374 JP PAT 4122174 US PAT 7048540 JP PAT 4160319 Manufactured by J MORITA MFG CORP This manual covers the TWINPOWER TURBINE 4H series handpieces which can be connected to Morita couplings CP4 O CP4 WO or CP5 O and other manufacturer s couplings PAR 4HEX O PAR 4HEX O KV WH SR NK PAR 4HX O PAR 4HX 0O KV WH SR NK PAR 4HMX 0O PAR 4HMX O KV WH SR NK l Morita CP4 O CP4 WO and CP5 O coupling KaVo MULTIflex and MULTIflex LUX coupling KaVo MULTIflex and MULTIflex LUX are registered trademarks for Kaltenbach amp Voigt GmbH 3 W amp H Roto Quick coupling W amp H and Roto Quick are registered trademarks for W amp H Dentalwerk B rmoos GmbH SIRONA R F coupling Sirona is a registered trademark for Sirona Dental Systems GmbH NSK Mach Phatelus FlexiQuick coupling Mach Phatelus and FlexiQuick are registered trademark for NSK NAKANISHI INC A A O A A AFG C DRE Operation 2009 09 24 WE 1e
10. S Qe Take the lamp out of its socket Operation 2008 04 21 Wp j Line up the grooves on the new lamp with the leads inside Screw the lamp cover on manually and then tighten it up the socket and push it all the way into place using the square hole on the cap tool Operation 2008 04 21 J MORITA MFG COR Reconnect the handpiece and operate it to make sure the lamp lights up Z WARNING Make sure the lamp cover is screwed all the way down If the handpiece is not properly connected to the tube air pressure could cause the tube to blow off which could cause an injury Order lamp cartridges from your local dealer or the J Morita office PANN 0 i Use only cartridge lamps made specifically for this model MFG CORF Operation 2008 04 21 For W amp H PAR 4HEX O PAR 4HX O PAR 4HMX O Body C Disconnect the handpiece from the main tube Turn off the lamp and rotate body C in the direction shown in the illustration Operation 2008 04 21 J MORITA f O ring Exhaust seal O ring Keeps body tight Take out the old lamp with tweezers CORP Service Socket Install the lamp so that the rim does not go in too far Noja If the rim goes into the socket the connection could be defective or the lamp could come out Rim J MORITA MI CORP Operation 2008 04 21 Service Z WARNING Make sure Body C is screwed all the way down If Body C the handpiece is not properly connected
11. ar object to remove the gasket 2 Remove the old valve and replace it with a new one 3 Replace the gasket in its original position gt A In m One Way Valve Gasket NNO Make sure not to damage the part of the gasket that presses up against the water pipe as this creates a crucial seal Operation 2009 09 24 INDEX 4H Spray Nozzle 7 Accessories 6 AR Spray 24 26 Autoclaving the Handpiece 32 Burs 12 Cap 35 Cap Tool 6 41 Capsule Cartridge 35 Cartridge Lamp 36 37 Contacts 76 CP4 O WO Coupling 77 CP5 O Coupling 77 Disinfection 32 Disposal 76 Handpiece Attachment 8 Inserting 15 Inspection 11 61 O ring 36 37 Parts 5 Points 12 Regular Inspection 4 61 Removal 16 Repairs 63 Replacement 6 63 Safety Precautions 1 Screwdriver 6 Specifications 71 Storage 60 Troubleshooting 64 EU Authorized Representative under the European Directive 93 42 EEC MEDICAL TECHNOLOGY PROMEDT CONSULTING GMBH AltenhofstraRe 80 66386 St Ingbert Germany TEL 49 6894 581020 FAX 49 6894 581021 The authority granted to the authorized representative MEDICAL TECHNOLOGY PROMEDT Consulting GmbH by J Morita Mfg Corp is solely limited to the work of the authorized representative with the requirements of the European Directive 93 42 EEC for product registration and incident report eal J MORITA MFG CORP 680 Higashihama Minami cho Fushimi ku Kyoto 612 8533 Japan ht
12. ays use spray and a soft intermittent touch to avoid injury to the pulp Wear protective glasses Always take the bur out of a handpiece before putting it back into its holder Leaving a bur in the handpiece could result in injury or damage to clothing or other objects J MORITA MFG CORP Operation 2008 04 21 Operation ANWARNING Use only the burs and points specified on page 12 Burs and Points Otherwise this could result in a bur coming out inside the oral cavity and being swallowed or in the patient being injured Never push the button while the handpiece is running This could cause the button to heat up resulting in burns to the patient or your fingers Take care that the push button does not press up against the teeth opposite to the working area especially molars this could cause the button to heat up and damage the tooth pulp It could also cause the button to wear out making it difficult to insert and remove burs Operation 2008 04 21 J MORITA MFG CORP Operation PANN i Crown removal and other similar operations produce considerable vibration and can cause the bur to get stuck in the handpiece Avoid this by frequently removing and reinserting the bur In case of abnormal noise or vibration during use replace the bur If this eliminates the problem the bur was defective If this does not solve the problem the handpiece needs to be repaired After long usage wear on bearings results in greater noise
13. chuck opening firmly down on a hard flat surface J MORITA MFG CORP Operation 2008 04 21 Screw the nozzle assembly onto the spray can with the Connect the handpiece to its tube Operate the handpiece nozzle for the handpiece connection sticking straight out for 2 or 3 seconds to blow out excess lubricant and clean the Insert the nozzle into the handpiece connection end and head Clean the cap with AR spray spray for 2 or 3 seconds Operation 2008 04 21 J MORITA MFG CORP Insert new cartridge Spray a little AR spray inside the head J MORITA MFG CORP Operation 2008 04 21 Service PAR 4HEX O PAR 4HX O If the O ring has come off line up the narrow section of the O ring and projection as shown in the illustration and reattach it If the narrow section of the O ring is not properly lined up the spray will not work properly Narrow section of O ring Projection Operation 2008 04 21 J MORITA MFG Projection Groove Make sure all 3 O rings are on the cartridge Line up the projection on the cartridge with the groove in the head and push it all the way in J MORITA A S Screw the cap on a little but leave a gap large enough for a new O ring Use tweezers to put the O ring provided with cartridge between the cap and head FG CORP Operation 2008 04 21 Service AN WARNING The O ring for the cap must be replaced with the new one provided Otherwise the cap could come off in
14. cks securely into place tube and then pull the handpiece off Operation 2009 09 24 Operation Except for Morita CP4 O WO or CP5 O coupling refer to the user s manual for the model you have PAR 4HEX O KV PAR 4HX O KV PAR 4HMX O KV_ KaVo MULTIflex and MULTIflex LUX coupling PAR 4HEX O WH PAR 4HX O WH PAR 4HMX O WH W amp H Roto Quick coupling PAR 4HEX O SR PAR 4HX O SR PAR 4HMX O SR_ SIRONA R F coupling PAR 4HEX O NK PAR 4HX O NK PAR 4HMX O NK NSK MachLite Phatelus coupling CORP Operation 2009 09 24 Operation NWARNING Before attaching the handpiece make sure that the coupling is in good condition not worn damaged cracked or loose that the tube O ring is in place and not pushed in too far and that the lamp cover on the tube is tightened securely Then give it a light tug to make sure it is securely fixed and check its operation outside the patients oral cavity Otherwise air pressure might force the handpiece off its tube connection resulting in serious injury Never exert any force that could cause the handpiece to come off while its running ANNONS Handle the motor carefully Do not drop it or bang it This could impair its performance For information on assembling the CP4 O WO and CP5 O Coupling refer to the page 77 Operation 2009 09 24 MORITA FG CORP 4 ALIIA Y Inspecting and Sterilizing before Use Operation lt Inspection gt Before using the handpiece make sure that
15. d inspection procedures However if necessary or desired these may be performed by a trained professional qualified to repair medical devices Contact your local dealer or the J Morita Office 1 J MORITA MFG CORP Operation 2008 04 21 Regular Inspection Check List Item Procedure a Use the Chuck Tester to check the chuck s gripping strength Replace the Capsule Chuck Gripping Strength Cartridge if the chuck has lost its gripping strength Cap Tightness Make sure that the cap and the cap screw are tightened properly Rotation and Spray Make sure the handpiece operates smoothly and emits a fine misty spray Operation 2008 04 21 MORITA MFG COR R Requir Capsule Cartridge PAR4HEX O PAR 4HX O PAR 4HMX O J MORITZ Operation 2008 04 21 64 Service The user should check the following pages if he thinks the instrument is not operating normally Operation 2008 04 21 J MORITA MFG CORP Poor Rotation gt Lubricate with AR Spray Disconnect handpiece and step on foot pedal Does air comes out of the end of the tube with enough force a IN O Defective tube Contact serviceman YES If other handpieces work OK replace the Capsule Cartridge Make sure the Capsule Cartridge is the correct one J MORITA MFG CORP Operation 2008 04 21 Service Disconnect handpiece Check coupling connection Step on foot pedal i Does air comes out of the end
16. e handpiece with a piece of gauze Operation 2008 04 21 J MORITA MFG COR Always use AR spray after replacing the cartridge Order Capsule Cartridges from your local dealer or the J Morita Office When ordering always specify the model PAR 4HEX PAR 4HX or PAR 4HMX Replacing the cartridge lamp For CP4 O WO PAR 4HEX O PAR 4HX O PAR 4HMX O and for W amp H PAR 4HEX O WH PAR 4HX O WH PAR 4HMX O WH only For KaVo PAR 4HEX O KV PAR 4HX O KV PAR 4HMX O KV SIRONA PAR 4HEX O SR PAR 4HX O SR PAR 4HMX O SR and NSK PAR 4HEX O NK PAR 4HX O NK PAR 4HMX O NK lamp replacement refer to the user s manual for the couplings of various makers MORITA MFG CORPF Operation 2008 04 21 Z WARNING Turn off the power switch to avoid the risk of burns and electrical shock The lamp and its cover are quite hot immediately after the lamp has burned out Avoid burning yourself do not touch these parts ANN e i Do not leave fingerprints or any foreign substances on the new lamp These could cause the lamp to break as soon as it is turned on which could cause an injury If necessary use Ethanol for Disinfection Ethanol 80 vol to clean the lamp Operation 2008 04 21 Service For CP4 O WO PAR 4HEX O PAR 4HX O PAR 4HMX O w amp Disconnect the handpiece from the main tube Turn off the power switch on the chair and take the tube s lamp cover off using the square hole on the cap tool w
17. ents are extremely hot after autoclaving do not touch them for at least ten minutes The handpiece could be damaged if it is not properly cleaned and lubricated before autoclaving Do not touch the push button when operating the handpiece to remove excess spray This could damage the cap or the Capsule Cartridge Do not leave the handpiece in the autoclave overnight Operation 2008 04 21 Service The Regular Inspection Check List has a list of replacement parts Replace these parts periodically or whenever they wear out Order parts from your local dealer or the J Morita Office Operation 2008 04 21 J MORITA MFG COR Capsule Cartridge with O ring and screw Cap with O ring and screw PAR 4HEX O PAR 4HEX O KV WH SR NK No 5010863 PAR 4HX O PAR 4HX O KV WH SR NK No 5010872 PAR 4HMX O PAR 4HMX O KV WH SR NK No 5010862 No 5011387 PAR 4HEX O PAR 4HEX O KV WH SR NK PAR4HMX O PAR 4HMX O KV WH SR NK No 5011386 PAR 4HX O PAR 4HX O KV WH SR NK Qo Operation 2008 04 21 Cartridge lamp O ring exhaust seal No 5020550 No 5012320 PAR 4HEX O WH PAR 4HEX O WH CD PAR4HX O WH PAR4HX O WH PAR 4HMX O WH PAR 4HMX O WH O ring prevents loosening of body O ring set No 5012320 No 5811500 PAR 4HEX O WH NK PAR 4HEX O NK oe Gy kaa Seoee PAR4HMX O WH NK PAR4HMX O NK Operation 2008 04 21 AG RITA IYI For Morita CP4 O WO Coupling
18. ion Thank you for purchasing a TWINPOWER TURBINE 4H handpiece This instrument is designed for dental treatment such as grinding drilling and polishing teeth For optimum safety and performance read this manual thoroughly before using the unit and pay close attention to the warnings and notes Keep this manual at hand for ready reference Caution Federal law restricts this device to sale by or on the order of a dentist for U S A Safety Precautions The instrument must be used in accordance with the instructions in this manual Read this manual thoroughly prior to operating or maintaining the instrument d F Operation 2008 04 21 Introduction Note the meaning of the following symbols and expressions NTN ANN This warns the user of the possibility of extremely serious or irreversible injury or a fatal accident Z NOTE This alerts the user to important points concerning usage Operation 2009 09 24 The user i e clinic hospital etc is responsible for the management maintenance and use of medical devices This instrument must not be used by anyone except legally qualified dentists and oral surgeons practitioners This instrument must not be used for any other than the intended purpose as specified in this manual Introduction Disclaimer The J Morita Mfg Corp will not be responsible for accidents equipment damage or bodily injury resulting from 1 repairs made by person
19. k with AR Spray and test it again If the chuck still fails the test replace the Capsule Cartridge Maintenance Z WARNING Test the chuck at least once a day or if the chuck s grip seems to be weak Never use a chuck which does not have enough grip a bur could come out in the patient s mouth and be swallowed or cause an injury Stop using the handpiece and have it repaired The yellow green chuck tester is designed specifically for the TWINPOWER TURBINE 4H and cannot be used for any other handpieces Do not autoclave the tester disinfect it by wiping it with Ethanol for Disinfection Ethanol 80 vol J MORITA MFG CORP Operation 2008 04 21 Maintenance Packaging Wipe the handpiece with a piece of gauze dampened with Ethanol for Disinfection Ethanol 80 vol and put it in a sterilization pouch Sterilization lt Autoclaving the Handpiece gt Recommended temperature and time minimum of 5 minutes at 134 C in a sterilization pouch Minimum drying time after sterilization 10 minutes AAQYRITA AAE Operation 2008 04 21 J MORITA MF NWARNING To prevent the spread of serious life threatening infections such as HIV and hepatitis B the handpiece must be autoclaved after the completion of each patient G CORP Maintenance ANN e i Do not sterilize in any way except autoclave Remove the bur or point before autoclaving Autoclave and drying temperatures must not exceed 135 C Instrum
20. nel not authorized by the J Morita Mfg Corp 2 any changes modifications or alterations of its products 3 the use of products or equipment made by other manufacturers except for those procured by the J Morita Mfg Corp 4 maintenance or repairs using parts or components other than those specified by the J Morita Mfg Corp and other than in their original condition 5 operating the equipment in ways other than the operating procedures described in this manual or resulting from the safety precautions and warnings in this manual not being observed 6 workplace conditions and environment or installation conditions which do not conform to those stated in this manual such as improper electrical power supply 7 fires earthquakes floods lightning natural disasters or acts of God Operation 2008 04 21 Introduction The J Morita Mfg Corp will supply replacement parts and be able to repair the product for a period of 10 years after the manufacture of the product has been discontinued Warranty is honored only when a claim is accompanied by the warranty agreement with purchase date product name and model serial number inscribed on the body of the product and name of the distributor Operation 2009 09 24 The user i e clinic hospital etc must perform the inspection procedures specified in the Regular Inspection Check List every three months Parts must be replaced periodically as necessary The Regular In
21. of the tube with enough force L N O Defective tube or water lines inside chair ae YES Replace the coupling s O ring MORITA AAFC CORI Operation 2008 04 21 J MORITA MEG CORP Clean spray hole Use the wire provided to clean out the spray hole After cleaning blow the hole out with a syringe and wipe the handpiece with gauze dampened with Ethanol for Disinfection Ethanol 80 vol Make sure the O rings on the Capsule Cartridge are properly installed J MORITA MF Operation 2008 04 21 Service Cannot insert burs or points gt Check that burs and points are OK 2 NO Use only burs and points that are suitable and in good shape YES Operation 2008 04 21 J MORITA MFG CORP Spray into chuck Replace the Capsule Cartridge Screw the nozzle assembly onto the spray can with nozzle for the chuck sticking straight out Cover the head with gauze insert the nozzle and spray into the chuck for 2 or 3 seconds Still cannot insert burs and points J MORITA MF Make sure the Capsule Cartridge is the correct one Connect the handpiece and operate it for 15 seconds to blow out excess spray Then wipe it clean with a piece of gauze Operation 2008 04 21 Service gt Lamp may be burned out N O Check tube and chair YES Replace lamp Operation 2008 04 21 J MORITA MFG
22. on 2008 04 21 Maintenance lt Lubrication gt Before autoclaving do not fail to lubricate and clean with AR Spray Z WARNING Do not point the spray nozzle at anyone and do not use the spray near an open flame Operation 2008 04 21 YAN 0 i The handpiece will malfunction without regular AR spray maintenance Never use any type of spray other than AR Spray Other lubricants will cause the coupling O ring to swell and make it difficult to connect and disconnect Also it could make it take longer to stop in an emergency Maintenance There are different spray nozzles for each type of coupling Look at the side of the nozzle to check this Make sure you use the right one Look here coupling mark No Mark Morita couplings CP4 O WO and CP5 O PAR 4HEX O PAR 4HX O PAR 4HMX O KV KaVo coupling PAR 4HEX O KV PAR 4HX O KV PAR 4HMX O KV WH W amp H coupling PAR 4HEX O WH PAR 4HX O WH PAR 4HMX O WH SR SIRONA coupling PAR 4HEX O SR PAR 4HX O SR PAR 4HMX O SR NK NSK coupling PAR 4HEX O NK PAR 4HX O NK PAR 4HMX O Nk CORP Operation 2009 09 24 Maintenance For Handpiece Chuck spray Nozzle Connection Insert all the way Shake AR spray can 2 or 3 times before using it Raise the Push the nozzle lever down Insert the nozzle into the lever on the nozzle assembly and swivel the chuck nozzle handpiece connection end and spray for 2 or 3 seconds down into position Cover the head
23. rque in direct proportion to the amount to which the exhaust air pressure exceeds 0 03 MPa A WARNING The PAR 4HEX O the PAR 4HX O and the PAR 4HMX O need special precaution regarding EMC Portable and mobile RF communications equipment can affect the PAR 4HEX O the PAR 4HX O and the PAR 4HMX O Technical Information Terminology and Symbols Ball Bearing Type Manufacturer Autoclavable up to 135 C Requires AR Lubrication Handpieces with this symbol may be cleaned and disinfected with a thermal washer disinfector Serial Number The first character of the serial number CE 0197 marking specifies the year of manufacture as follows Conforms to European medical V 2007 W 2008 X 2009 device Directive 93 42 EEC Operation Instructions Authorized representative in M f ET i Sc e rer the European Community Operation 2009 09 24 Technical Information For repair or other types of service contact your local dealer or the J Morita Office Ki 26 Any medical devices which could possibly be contaminated must be first decontaminated by the responsible doctor or medical institution and then be disposed of by an agent licensed and qualified to handle medical and industrial waste Operation 2009 09 24 CP4 O WO and CP5 0 Coupling CP4 O lt with light gt Coupling CP4 WO lt with light and Spray Control gt Coupling Before use check the following items Does the connection end
24. side the patients mouth and be swallowed or cause an injury Replace the cap if the projection on the inside is worn away Operation 2008 04 21 J MORITA MFG CORP Screw the cap down manually until it is seated on the head Fit the cap tool securely onto the cap and tighten up the cap Do not use the cap tool to screw down the cap from the Line up the notch on the cap with the hole for the cap screw beginning this could damage the threads J MORITA MFG CORP Operation 2008 04 21 Service Align notch and hole Do not tighten the cap too much This could damage the Tighten up the cap screw with the screwdriver threads so that the hole and notch no longer line up Operation 2008 04 21 J MORITA MFG COR A WARNING Make sure the notch on the cap is lined up with the hole for the screw If the notch goes beyond the hole the threads are worn contact your local dealer or the J Morita Office to have the instrument repaired Make sure the cap screw is tight enough If the cap screw or cap comes out in a patient s mouth it could be swallowed or cause an injury Make sure there is no gap between the cap and the head If there is do not use the handpiece have it repaired J MORITA MFG CORP Operation 2008 04 21 Insert the nozzle into the handpiece connection end and Connect the handpiece and operate it for at least 15 seconds spray for 2 or 3 seconds to blow the excess lubricant out of the head Then wipe th
25. spection Check List includes a replacement parts list Introduction Parts Identification and Accessories Parts Identification Tool Guide Head Push Button Aeroskirt Cap Spray Hole Light Guide Notch Handpiece Connection Connection end differs for various models Cap Screw CO R P Operation 2008 04 21 Accessories Introduction For Inspection and Parts Replacement For Capsule Cartridge Replacement Chuck Grip Tester No 5010695 Ethanol disinfectable Spray Hole Wire No 5250940 PAR 4HEX O PAR 4HX O No 5010840 PAR4HMX 0 Autoclavable Screwdriver No 5011440 Ethanol disinfectable Cap Tool also used to change lamp No 5011328 G Ethanol disinfectable Operation 2009 09 24 Introduction For Spray AR Spray 4H Spray Nozzle Ethanol disinfectable AR Spray 4H Spray Nozzle l No 5010212 or No 5010307 No 5010293 lt No 5010295 No 5010299 No 5010216 PAR 4HEX O PAR4HEX O KV PAR4HEX O WH PAR4HEX O NK PAR 4HX O PAR4HX O KV PAR4HX O WH i PAR4HX O NK PAR4HMX O PAR4HMX O KV PAR4HMX O WH PAR4HMX OSR PAR4HMX O NK Operation 2008 04 21 8 Operation Operation z lt Connect gt lt Disconnect gt For Morita CP4 O CP4 WO and CP5 O coupling PAR 4HEX O PAR 4HX O PAR 4HMX O Hold the tube and slide the handpiece Pull the coupling slightly towards the over until it cli
26. the cap and The handpiece is not sterilized before shipping It must be cap screw are tightened properly and that there is no gap autoclaved before being used for the first time between the head and the cap If you discover any problem with the above items do not use the handpiece but have it repaired instead CORP Operation 2008 04 21 Burs and Points Bur and Point Specifications Operation PAR 4HEX O PAR 4HX O PAR 4HMX O Shank Diameter ISO standard ee ee Tip Diameter 2 0 mm max Total Length 22 mm max 18 5 mm max Shank Length 10 mm min 7 5 mm min Operation 2008 04 21 Shank Length Tip Diam a ae Shank Diam ISO Standard Total Length Flat End J Grooves Se b DON T USE DON T USE Operation ANWARNING Do not use burs and points which do not conform to ISO standard with scratched or damaged heads or shanks which are bent twisted rusty or chipped which have been modified in any way Sub standard or damaged burs and points are very dangerous to use they can come out and injure the patient or be swallowed Use only short shanked burs with the PAR 4HMX O Never use short shanked burs and points with the PAR 4HEX O PAR 4HX O shanks will not reach all the way to the back of the chuck J MORITA MFG CORP Operation 2008 04 21 Operation ANN 0 i Always use burs and points with clean shanks dirty shanks cause the chuck to
27. to the y tube air pressure could cause the tube to blow K off which could cause an injury PAN Xe Use only cartridge lamps made specifically for this Screw body C back into its original place Reconnect the model handpiece and operate it to make sure the lamp lights up Order lamp cartridges from your local dealer or the J Morita office Operation 2008 04 21 MORITA MEG COR Replacing the O rings PAR 4HEX O NK PAR 4HX O NK PAR 4HMX O NK only O ring prevent loosening of body O rings Body C lt lt 1 Take the handpiece off its main tube 2 Turn Body C in the illustration in the direction shown by the arrow and take it off 3 Take off the O rings with tweezers or some other suitable tool 4 Put on the new O rings 5 Spray the O rings with AR Spray 6 Replace Body C Z AWARNING Tighten Body C securely all the way Otherwise air could leak out and prevent a proper connection with the coupling CORP Operation 2008 04 21 60 Service Storage conditions Temperature 10 70 C Humidity 10 85 RH without condensation Atmospheric pressure 700 1 060 hPa Avoid frequent exposure to direct sunlight Store the handpiece in a clean dry place after autoclaving it Operation 2008 04 21 J MORITA MFG CORP Regular Inspection Use the Inspection Check List provided to inspect the instrument every 3 months Tt is assumed that the user will perform regular maintenance an
28. tp Awww jmorita mfg com Distributors J MORITA CORPORATION Tokyo Office 11 15 2 Chome Ueno Taito ku Tokyo 110 8513 Japan Osaka Office 33 18 3 Chome Tarumi cho Suita Osaka 564 8650 Japan http asia morita com _http oceania morita com J MORITA USA Inc 9 Mason Irvine CA 92618 U S A TEL 1 949 581 9600 FAX 1 949 465 1095 http www jmoritausa com J MORITA EUROPE GMBH Justus Von Liebig Strasse 27A D 63128 Dietzenbach Germany TEL 49 6074 836 0 FAX 49 6074 836 299 http Awww jmoritaeurope de SIAMDENT CO LTD 444 Olympia Thai Tower 3rd Floor Ratchadapisek Road Samsennok Huay Kwang Bangkok 10310 Thailand TEL 66 2 512 6049 FAX 66 2 512 6099 _http Awww siamdent com J MORITA CORPORATION Australia and New Zealand Suite 2 05 Aero 247 Coward Street Mascot NSW 2020 Australia TEL 61 2 9667 3555 FAX 61 2 9667 3577 http oceania morita com 09 10 8 000 PUB H5054 E 1 Printed in Japan
29. trol Dial Tube Ring Operation 2009 09 24 MN NAN INE Hold the tube ring to adjust the amount of spray The handpiece could come off its connection and injure someone if it is held by the part indicated by the mark VN Xe i If the coupling is not securely tightened up with the wrench water or air could leak CP4 O WO and CP5 0 Coupling 4 Coupling O ring Replacement ANW ARNING Remove and replace all the old O rings otherwise air pressure could cause the tube to blow off resulting in an injury Replace the five O rings if air or water starts to leak After replacement remove the 4H Spray Nozzle from the AR Spray can and lightly coat the O rings with AR Spray J MORITA MFG CO Ad Operation 2009 09 24 CP4 O WO and CP5 0 Coupling 5 Replacing One way Spray Valve Inspecting One way Valve Cutting debris and other foreign matter could be sucked into the water tube if the one way valve is not working properly Inspect it once a month Operation 2009 09 24 Tj Spray Pipe N Remove the needle from a plastic syringe and fit the end over the spray pipe Check that there are no gaps between it and the gasket Pull the plunger out a little and then release it If the plunger moves back in the valve is OK Replace the valve if the plunger does not go back in at all CP4 O WO and CP5 0 Coupling 6 Replacement 1 Use a needle or simil