DRF-FR Series - OMEGA Engineering

image

Contents

1. vena ESA C E WARRANTY Shop online at omega com CEOMEGA omega com e mail info omega com For latest product manuals omegamanual info DRF FR FOR FREQUENCY INPUT DRF Series Signal Conditioners omega com x OMEGA OMEGAnet On Line Service Internet e mail omega com infoQomega com Servicing North America U S A ISO 9001 Certified Canada One Omega Drive Box 4047 976 Bergar Stamford CT 06907 0047 Laval Quebec H7L 5A1 Canada Tel 203 359 1660 Tel 514 856 6928 FAX 203 359 7700 FAX 514 856 6886 e mail infoQomega com e mail info omega ca For immediate technical or application assistance U S A and Canada Mexico Sales Service 1 800 826 6342 1 800 TC OMEGA En Espa ol 001 203 359 7803 Customer Service 1 800 622 2378 1 800 622 BEST FAX 001 203 359 7807 Engineering Service 1 800 872 9436 1 800 USA WHEN e mail espanol omega com TELEX 996404 EASYLINK 62968934 info omega com mx CABLE OMEGA Servicing Europe Benelux Germany Austria Postbus 8034 1180 LA Amstelveen Daimlerstrasse 26 D 75392 The Netherlands Deckenpfronn Germany Tel 31 0 20 3472121 FAX 31 0 20 6434643 Tel 49 0 7056 9398 0 Toll Free in Benelux 0800 0993344 FAX 49 0 7056 9398 29 e mail sales omegaeng nl Toll Free in Germany 0800 639 7678 Czech Republic e mail info omega de Frystatska 184 733 01 Karvina Czech Republic United Kingdom ISO 9002
2. 9 GALVANICISOLATION LEVELS 9 GENERAL SPECIFICATIONS 9 MATERIALS criar leal 9 CAUTIONS WARNINGSANDNOTES 10 SAFETY CONSIDERATIONS PRESCRIPTION Before starting any operation of adjustment MALE maintenance or repair the unit must be disconnected from any kind of power supply Keep the unit clean to assure good functioning and per formance To prevent electrical or fire hazard do not expose the unit to excessive moisture Do not operate the unit in the presence of flammable gases or fumes such an environment definetely constitutes a safety hazard The unit is designed to be mounted on a metal panel If the unit shows signs of damage is not able to show the expected measures has been stored in a bad conditions or a protection failure happened then do not attempt to operate keep the unit out of service and send for repair INCASE OF FIRE 1 Disconnect the unit from the power supply 2 Give the alarm according to the local rules 3 Switch off all air conditioning devices 4 Attack the fire with carbonic snow do not use water in any case WARNING In closed areas do not use systems with vaporized liquids GENERALINFORMATION The DRF series of Isolated Signal Converters allow to convert process signals temperatures electrical signals etc to current loops or voltage signals for further retransmision while introducing into the
3. which include your desired adjustment Then proceed to the adjustment Selection Jumpers Output Signal Range 0 20mA 4 20mA 0 10Vdc Selection Jumpers Input Signal Range Selection Jumpers Input Signal Type See next page Operate span potentiometer until getting an output which is the difference between the high and low output levels 10 0 10Vac 5 Input low input level 042 Operate offset potentiometer until getting the low level output ovac 6 Input high input level and check that that the output also matches the desired level 1000 Hz 10Vdc If more accurate measurement is needed repeat steps 5 and 6 Most of the input output combinations will be properly adjusted within the instrument accuracy after these steps Close front cover once calibration is finished Selection Jumpers Input Signal Type ad V Selection Jumpers mee an od o 255 x or os gt z ola s 9355 Banen O s 8308 gt Z S EROS o BORD o E S 52835 i DOUG S Mono 2225 2 Eo 3 GC c 4 9908 9000 e IBID z NARA aan 2 5329090008 E o ES O2 35 o v SH o gt gt A N N I N I N lt BSQSGRR 00 s 1 DANNA cados 908D SO O STO PLL N N L N I N lt A opaoope 2 HE HE DE E E naa salon elannls a 4 O PO gt N I 11108 aaa cease Do BER AS 208993 4 GL DE N T T TER E 2 VL DD DE 5 55 520090999 lt a 000000 20000909 se V DR 9mm 0 357 Out
4. system galvanic isolation barriers between the input the output and the power supply circuits The DRF series of Isolated Signal Converters offer an excellent relation between signal conversion speed and measurement accuracy Offering up to a 0 2 accuracy and down to 70ms response time these units can process information coming from probes or transducers in such a way that can be quickly retransmitted in a fast and accurate form to remote data acquisition systems or PLC s The isolated signal converters ofthe DRF series are ideal to integrate into 12 bit data acquisition systems Its powerful galvanic isolation of 3500 V introduces high security tothe measuring systems preventing the propagation of those phenomenon which usually cause damage such as transient peaks or energy shocks in any of the circuits of the system The galvanic isolation also acts as a strong CE barrier The decoupling created between the circuits avoids pernicious effects on the output such as ground loops or signal leaks which distort the acquired data and are extremely difficult to isolate once introduced into the signal DR a The isolation offered by the DRF series of Isolated Signal Converters is a 3 way isolation Thus all the benefits exposed above are applicable to any of the three circuits composing the instrument input output and power Recalibration ofthe instruments is realized ina fast and easy way Opening the front cover gr
5. Certified Tel 420 0 59 6311899 One Omega Drive FAX 420 0 59 6311114 River Bend Technology Centre Toll Free 0800 1 66342 Northbank Irlam e mail info omegashop cz Manchester M44 5BD France United Kingdom 11 rue Jacques Cartier Tel 44 0 161 777 6611 78280 Guyancourt France FAX 44 0 161 777 6622 Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in United Kingdom Toll Free in France 0800 466 342 0800 488 488 e mail sales omega fr e mail sales omega co uk It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications DR a INDEX GENERALINFORMA TION scort 4 OE LE k a a ea aaa 5 POWER SUPPLY CONNECTIONS 5 SIGNAL ADJUSTMENT sion 6 and 7 DIMENSIONS AND CONNECTIONS 8 TECHNICAL PAA none ea ot a elan 9 INPUT SIGNAL sucerceventectrnescsrvacsantesethersazescensias 9 OQU TPUT SIGNAL sspicnicandaia ins 9 POWER SUPPLY escocia 9 MECHANICAL DIMENSIONS
6. ants access to the configuration jumpers Additional Span and Offset potentiometers are directly accessible fromthe frontal part These potentiometers are highly decoupled minimizing the iterations needed to obtain a correct adjustment In order to obtain a higher and quickest benefit of the DRF units we recommend you to read carefully the information provided inthis manual before proceeding to the installation of the instrument In this manual you will find all technical data both electrical and mechanical needed for acorrect instalation and utilization Note The DRF Series Isolated Signal Converters have a characteristics label attached on the side of the instrument Check that this information matches with your requirements for the specific application and especially check the value and type of the Power Supply QUICK GUIDE The DRF units have a front cover which can be opened down This cover gives access to the Span and Offset potentiometers and to the selection jumpers for input and output signal ranges To open the front cover press slightly the sides of the cover at the upper side close tothe OUTPUT terminals as indicated on Figure1 The cover is free to open down as shown on Figure2 POWER SUPPLY CONNECTIONS DRF units are powered through the plug interminal positioned on the upper side of the instrument This terminal is placed in atransverse axis different from the other terminals Close to th
7. ct was PURCHASED 1 Purchase Order number to cover the COST 2 Model and serial number of the product under of the repair warranty and 2 Model and serial number of the product and 3 Repair instructions and or specific problems 3 Repair instructions and or specific problems relative to the product relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC O Copyright 2005 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do I Find Everything I Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE Uf Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies A Wire Thermocouple RTD amp Thermistor A Calibrators amp Ice Point References A Recorders Controllers amp Process Monitors Uf Infrared Pyrometers PRESSURE STRAIN AND FORCE Uf Transducers amp Strain Gages Uf Load Cells amp Pressure Gages A Displacement Transducers A Instrumentation amp Accessories FLOW LEVEL 14 Rotameters Gas Mass Flowmeters amp Flow Computers Uf Air V
8. e power supply terminal there is a small yellow label with indications on the connections for AC and DC FIGURE 2 SIDE View DR a FIGURE1 FRONT View WITH COVER IMPORTANT Check that the power supply indicated on the white label attached to the side of the instrument matches with the power supply you want to connect For more accurate information on the power supply connections please see page 6 of this manual P OWERSUPPLY TERMINAL FRONT COVER OPENING ACCESS TOJUMPERS FOR INPUT AND OUTPUT RANGE SELECTION AND ACCESS TO SPAN AND OFFSET ADJUST POTENTIOMETERS Ice V SIGNAL ADJUSTMENT To proceed to adjust a range of input and output signals first select with the appropriate jumpers the signal ranges S ELECTION JUMPERS OUTPUT SIGNAL SPAN POTENTIOMETER OFFSET POTENTIOMETER S ELECTIONJUMPERS INPUT SIGNAL FIGURE 3 FRONT View WITHOUT COVER For your safety select input and output jumpers BEFORE generating signal for the adjustment Adjustment 1 Connect input signal to terminals 8 Signal and 9 common 2 Connect a multimeter to the output signal terminals 4 and 5 for mA or 4 and 6 for Vac Values in brackets are examples for a calibration 0 1 KHz 0 10Vac 3 Input a zero signal 0Hz Operate offset potentiometer until getting a zero output ovac 4 Input the difference between the high and low input levels 1000 0 1000Hz DR a
9. elocity Indicators A Turbine Paddlewheel Systems 14 Totalizers amp Batch Controllers pH CONDUCTIVITY A pH Electrodes Testers amp Accessories A Benchtop Laboratory Meters 14 Controllers Calibrators Simulators amp Pumps Uf Industrial pH amp Conductivity Equipment DATA ACQUISITION A Data Acquisition amp Engineering Software Uf Communications Based Acquisition Systems Uf Plug in Cards for Apple IBM amp Compatibles A Datalogging Systems A Recorders Printers amp Plotters HEATERS Uf Heating Cable Uf Cartridge amp Strip Heaters 14 Immersion amp Band Heaters l Flexible Heaters Uf Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL A Metering amp Control Instrumentation lA Refractometers 14 Pumps amp Tubing LA Air Soil amp Water Monitors 14 Industrial Water amp Wastewater Treatment Uf pH Conductivity amp Dissolved Oxygen Instruments M4136 0305
10. is delivered in good conditions This Users Ma nual contains useful information the user has to respect in order to warrant a proper function of the unit and good security conditions The unit is designed for internal applications with good ventilation to avoid excessive heating It can occasionally be applied to temperatures down to 10 C or up to 70 C without security degradation Do all connections before applying power to the unit Do not make wiring changes until power is disconnected from the unit Install the unit far from elements generating electric noise or magnetic fields such as power relays electrical engines speed regulators etc Do not use until installation is completed POWER SUPPLY The power supply must be connected to the adequate terminals 1 2 and 3 The characteristics of the power supply are shown on the side label Please make sure that the unit is correctly connected to a power supply of the correct voltage and frequency Do not connect the unit to lines which are overloaded or which provide power to systems working on ON OFF cycles or inductive loads ATTENTION If the power supply is DC voltage be careful with the polarity indicated for each terminal SIGNAL WIRING Certain considerations must be given when installing the signal input wires If the wires are long they can act as an antenna introducing electrical noise into the unit Therefore Do not install the signal inpu
11. levels are also sometimes named as STRENGTHENED ISOLATION levels for systems with Polution Level 2 GENERAL SPECIFICATIONS Accuracy lt 0 2 F S Optimizedfor 12 bit systems Linearity lt 0 1 F S Thermal Drift lt 250 ppm C Tipical Warm UpTime 5 minutes Response Time for signal ranges of 0 100 Hz lt 300mS 90 of signal 0 500 Hz lt 250mS 90 of signal 0 5 KHz lt 200mS 90 of signal 0 50 KHz lt 150mS 90 of signal Plug In Screw Terminals Maximum Wire Section 2 5 mm Protection IP 30 Temp Operation from 0 to 60 C Temp Storage from 20 to 70 C MATERIALS Box and Cover in Poliamide PA6 UL94 V 2 blue color Terminals in Poliamide UL94 V 0 CAUTIONS WARNINGS AND NOTES INSTALATION PRECAUTIONS The installation and the future use of this unit AAN must be done by qualified N personnel The unit has not AC mains switch neither internal protection fuse It will be in operation as soon as power is connected The installation must incorporate an external mains switch with a protection fuse and also the necessary devices to protectthe operator and the process when using the unit to a control machine or process where injury to personnel or damage to equipment or process may occur as a result of failure of the unit RECOMMENDED FUSES 24 Vdc 230 Vac 115 Vac 250mA 70 mA 100 mA All fuses Time Lag Fuse SAFETY PRESCRIPTIONS The unit has been designed and tested AN under EN 61010 1 rules and
12. or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PRO CESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insur ance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the FOR NON WARRANTY REPAIRS consult following information available BEFORE contacting OMEGA for current repair charges Have the OMEGA following information available BEFORE con 1 Purchase Order number under which the tacting OMEGA produ
13. put Connections dli ka de ar EE 93mm OUTPUT pe 3 66 Input Connections SENSOR POWERED NAMUR OR PNP EXTERNALLY SENSOR POWERED FROM DRF AAA 7 Special Width for 24 Vdc AC Power models DC Powered x ACPowered OVd Use V TECHNICAL DATA DRF FR INPUT SIGNAL in FREGUENCY RANGES 50KHz 30KHz 20KHz 10 KHz 5KHz 3KHz 2KHz 1KHz 500Hz 300Hz 200Hz 100Hz 60Hz 40Hz 20Hz minimum 10Hz SIGNAL NPN PNP NAMUR PICK UP Voltage Impulse SINUSOIDAL up to 200Vac Vexc 15 Vdc 20mA 9V2 for NAMUR OUTPUT SIGNAL in VDC RANGES 0 10 Vdc 0 1 Vdc Max Output 11 Vdc approx Min Output 1Vdc approx Min LoadR gt 1KOhm OUTPUT SIGNAL in mA RANGES 0 20mA 4 20mA Max Output 22mA approx Min Output 1 5mA approx Max Load R lt 400 Ohms POWER SUPPLY DC Power 24Vdc 10 AC Power 230Vac 10 50 60 Hz 115Vac 10 50 60 Hz Consumption lt 3 8VA MECHANICAL DIMENSIONS DC Units 22 5 x 93 x 110 mm AG Units 37 0 x 93 x 110 mm Weight DC 120 gr Weight AC 200 gr Standard DIN rail mounting as specified on DIN46277 and DINEN 50022 97 5 X 7 5 mm 1 38 x 0 3 3 DR a GALVANICISOLATION LEVELS DCUnits Input Output 3 5 KV 60 seconds Power Input 3 5 KV 60 seconds Power Output 1 KV 60 seconds AC Units Input Output 3 5 KV 60 seconds Power Input 3 5 KV 60 seconds Power Output 3 5 KV 60 seconds All isolation levels are tested during a time of 60 seconds with current leaks lt 1mA Note Indicated isolation
14. t wires in the same conduit with power lines heaters solenoids SCR controls etc and always far from these elements When shielded wires are used leave unconnected the shield on the transmitter side and conect the other end of the shield to the ground terminal of the machine EXCITATION VOLTAGE Model DRF PR incorporates an internal power supply for transducers The output of this power supply is connected to terminals 7 and 9 Do not connect these terminals to an external power supply beacuse both units will be permantently damaged WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s Warranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unau
15. tho rized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental