Home

User Manual - ICP DAS USA`s I

image

Contents

1. Set Size W amp H as 155 amp 25 Fore Color as the below picture To Which Page as 1 Title as Go To Page 1 and then click Ok ize TW Ask before Location X 4 Ask message Font size Request message Fore Color To Which Page Appearance Title Go To Page 1 Next set up the upload IP configuration Click Project gt IP Setting enter the IP address of PAC and then click Setting soft GRAF HMI Editor DemoO1 s Click the upload tool icon x click Yes to answer the save project question then the upload process begins After uploading the result shows up automatically on the PAC s VGA as the picture below if the HMI creation succeeds soft GRAF HMI Editor Demoalll sof File Project Help ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Haven Liu Version 1 01 Date Oct 2011 Page 23 70 OM gt 5 sec gt 0FF Soft GRAF DemoO1 OM OFF ON gt 5 sec gt OFF Goto Page 2 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 24 70 1 3 HMI Objects Description 1 3 1 g Label Display a Label Hello Word EEUU SPE eee 3 c
2. 1 3 14 g Bar display a Bar meter picture to show a 32 bit signed integer 16 bit signed integer or 32 bit float value n eee nL SUD aar 1O00 s EH 1 scale color 6 2 2 e go feet er 3 Location X show alus 8 show scale il 4 o CE 5 Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 32 bit Long integer and 32 bit REAL variables defined in the ISaGRAF must occupy two network addresses Refer to chapter 4 2 of the User Manual of ISaGRAF PAC 2 Size the size of the object W for Width H for height 3 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 4 ForeColor the fore color of the Bar meter 5 BackColor the back color of the Bar meter 6 Scale Color the color of the scale 7 Data Type select the data value type Can be long 32 bit sign intger word 16 bit signed integer or real 32 bit float 8 Show Value check to show the current value 9 Show Scale check to show the scale ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 45 70 pettine l Setting de iiim 13 um p j e s Unit Transfer ai 15 11 16 12 tiber 17 D E 18
3. Author Raven Liu Version 1 01 Date Oct 2011 Page 66 70 The HMI screen on the PAC is as below Demo05 has 10 pages and illustrated as following My Sweet Home 2011 10 18 14 59 37 Tuesday To See My Family To Page 2 Welcom to the Soft GRAF demo05 Please refer to www icrpdas com gt FAQ gt Software gt ISaGRAF gt FAQ 146 Back to previous page Press to different pages ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 67 70 Back to Elephant previous page Press ON OFF to show different effect Turtle Back to previous page Input value 1 8 to switch the pictures ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 68 70 Ladybug Back to previous page I like to take a bubble bath in Ladybug s home 25 0 C Input values 1 3 to show different text Back to previous page Press ON OFF to show different effect Can give an Integer to set the temperature ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 69 70 Lucky Cat Back to previous page
4. ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 9 70 Add one Boolean variable LED 01 into the Dictionary of the ISaGRAF project and set its address as 11 key in the Hex number B EE File Make Project Tools Debug Options Help P Be DE tm S Mie um 4 Boolean Yariable M ama BED Network Address pele cite ue Number B that is Attributes Values 11 in decimal rue D Output Next Comment Cancel t Constant get bo true at init Retain Previous lii File Edit Sime Options Help pd oce uda Booleans ntegers Reals Timers Messages FB instances Defined worda Hame Attrib Ader Comment n LED 01 jitema nnne Net raddr 11 After finishing ISaGRAF SoftLogic You must compile and download the ISaGRAF project into your PAC Refer to Ch 2 of ISaGRAF Advanced manual for the steps then can design the HMI Run Soft GRAF Studio to edit the HMI First create a project sof as below Click File New of menu bar or click Create New File tool icon Soft GRAF HMI Editor File Project Help i n ir x 136 CE sn mmm S ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 10 70 Gi
5. 10 Bar Range set the maximum and minimum limit of the Bar range 11 Unit Transfer the unit transfer function If checked to enable it transfers the value according to the range of Bar Range Ex Bar Range 0 0 1000 0 means the minimun value is 0 0 the maximum is 1000 0 set Unit Transfer 0732767 it will tranfer 0 32767 to 0 0 1000 0 12 Dot define the digital number after the dot can be O 6 13 Using Alarm using the Alarm function If checked to enable then can set the value and color of Low Alarm Up Alarm 14 Up Alarm the Up limit of the Alarm 15 Up Alarm Color the color of the Up Alarm 16 Low Alarm the Low limit of the Alarm 17 Low Alarm Color the color of the Low Alarm 18 Alarm Blink set the alarm blinking options when the value is larger smaller than the Up Alarm or Low Alarm There are 4 options a No Blink no blink b Up Alarm blink if larger than the Up Alarm value c Low Alarm blink if smaller than the Low Alarm value d AII Blink blink both when larger and smaller ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Haven Liu Version 1 01 Date Oct 2011 Page 46 70 1 3 15 g_Rect Draw a rectangle Location X Edge Width 1 Size the size of the object W for Width H for height 2 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 3 Edge Wid
6. Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 1 70 Soft GRAF Studio Create a Colorful HMI in the XP 8xx7 CE6 amp WP 8xx7 amp VP 2xW7 PAC SOft GRAF an HMI software developed by ICP DAS allows user to create his colorful HMI application running with the control logic in the same PAC Using the PAC with the Soft GRAF support user can easily edit its HMI screen by Soft GRAF Studio and design the control logic by ISaGRAF software There are three types of HMI Objects in the Soft GRAF Studio Label Value Button Input Drawing User can create the HMI object directly by using the mouse to drag and drop the Object into the editing screen and set the properties by mouse keyboard to achieve different display ISaGRAF Soft GRAF Studio SoftLogic O ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 2 70 1 1 Soft GRAF Studio Version and Installation Soft GRAF Studio Installation The Soft GRAF Studio is version 1 01 now Please get the document faq146 and demo programs from the following folder of CD ROM in your PAC package CD ROM napdos soft graf Or download it from the following website www icpdas com FAQ Software ISaGRAF 146 http www icpdas com fag isagraf htm 146 Other related information ISaGRAF User
7. Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 39 70 1 3 11 g B Pic Display a picture to show a Boolean value The picture format can be JPG PNG GIF or BMP BMP is not suggested due to the large size memory Pic setting a a z 4 5 Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 2 Size the size of the object W for Width H for height 3 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 4 True File the picture showed when read a True value Refer to Ch 1 5 for more about the dynamic image format 5 False File the text showed when read a False value Refer to Ch 1 5 for more about the dynamic image format ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 40 70 1 3 12 g N pic Display a picture to show a Integer value The picture format can be JPG PNG GIF or BMP BMP is not suggested due to the large size memory Studio PAC Description Value 0 Value Value 2 Displayed figure 1 NetWork Address 2 mize Wy mo H m 7 3 Location X ps v Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 32 bit Long integer and 32 bit REAL variables defined in the ISaGRAF must occu
8. There are two overlapped objects g_Label Label button and g_B_Inp The object g_Label has the higher Layer than the g_B_Inp and covers on it NN F F Select the Label and click on the tool icon Sent to Back then can see g_B_Inp Project View Buttor Input wi When the HMI page needs a background picture please add it via g B Pic object Recommand user to add it at the last step for the convenience First drag a g B Pic object eae RIA ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 54 70 Mouse right click on the object select Setting and set the False File Select a background picture for the False File and then click Ok If the picture is covering other objects please select it and click the Sent to Back until all other objects showing up Net Work Address 0 mize Wiz Location X ua p Trus Fik Fal File ERO Qm Led03 B m 1 Soft GRAF 1 gif gt HLS aee op ds SC ERU CT l Image Formatzt bmp 4pgz eif pue v ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 55 70 Net Work Address oo Location X o f Troe i Flo Fil ICP DAS Co Ltd Technical document Classification ISaGRAF F
9. 4 i 8 Options 1 Net work Address the ISaGRAF Modbus NetWork Address for the variable useless for in the g Label object 2 Font size set the font style and size of the label text useless in other font setting 3 Fore color the fore color of the label 4 Back color the back color of the label 5 Size the size of the label W for Width H for height 6 Location the X Y axis of the label Refer to Ch 1 2 for how to display the axis 7 Text Align left center and right align for the text 8 Title the text on the label Double click the Textbox to enter the long text ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 25 70 1 3 2 g B Val display a text to show a Boolean value Description Value True Value False Working Displayed figure Stop a 2 Fale Tine a 4 Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 2 Font size set the font style and size of the text useless in other font setting 3 Fore color the fore color of the object True the fore color to display if the read ISaGRAF value is True False the fore color to display if the read ISaGRAF value is False 4 Back color the back color of the object True the back color to display if the read ISaGRAF value is True False the back color to display if
10. Or using the mouse left key to change the Object size Use the mouse left key to resize ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 13 70 Next set up the title of g Label Object for the text displayed on the object Double click the text box of the Title and key in Soft GRAF Demo 01 then click Accept button to close the window and click ok to end the setup E a Common mize 300 M Net Work Address EN Font size D Regular Location X 1in2 Y 5 Back Color Tile usd e Double click on the box EditMassStringFrm x Key in Soft GRAF Demo 01 P a Common Wet Work Address Size H go Font size Location X jg Y 51 Fore Color Text Alen Center Back Color Title ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 14 70 Next create a g B Led object Drag amp drop a g B Led object to the editing area mouse right key click on the object and select setting to configure the following setting such as Network address 11 Size W 40 Size H 40 Font 10 Bold Shape Circle Project View Fage 1 Drawing v Led setting Net Work Address True False Message when
11. 70 1 5 How does the Soft GRAF driver distinguish the picture animate or not NOTE Only the objects g B Pic and g N Pic can use the animate picture that support by Soft GRAF The animate picture file should be named as ABC gif or jpg or png The ABC is three number of O 9 If the picture format is correct and the file name is correct the Soft GRAF driver will display it as animate picture The AB defines the amount of pictures to be animate The C defines the time period to switch pictures can be O to 9 If C is O it means the picture is not animate The unit of C is about 0 125 seconds for XP 8xx7 CE6 PAC while is about 0 25 seconds for WP 8xx7 and VP 2xW7 PAC For ex gif Fan04 s 061 gif means the file is an animate picture It contains 6 pictures The switching time is about 0 125 seconds for the XP 8xx7 CE6 PAC about 0 25 seconds if running in the WP 8xx7 and VP 2xW7PAC For ex gif Fan04 s 062 gif means the file is an animate picture It contains 6 pictures The switching time is about 2 x 0 125 0 25 seconds for the XP 8xx7 CE6 PAC about 0 5 seconds if running in the WP 8xx7 and VP 2xW7PAC For ex AgifiFan04 s 060 gif is not an animate picture because the switching time is 0 The following picture is the content in the gif Fan0O3 s 041 gif It consists of 4 small pictures to become a big picture from left to right The Soft GRAF driver will display it as
12. Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 5 70 The HMI objects below are supported by Soft GRAF driver since Ver 1 09 Label Value Type g Label Display a Label g B Val Display a Text to show a Boolean value g WD Val Display a 16 bit integer occupy 1 Network addr number g N Val Display a 32 bit integer occupy 2 Network addr numbers g F Val Display a 32 bit Float value occupy 2 Network addr numbers 6 g N Text Display a text to show an Integer value Button Input Type Create a button to input a Boolean value g WD inp Create a button to input a 16 bit integer value Occupy 1 Network addr Create a button to input a 32 bit Float value occupy 2 Network addr numbers 4 Create a button to input a 32 bit integer value occupy 2 Network addr numbers 5 Create a Login button with password g Logout Create a Logout button 7 g ToPage Create a switch page button Drawing Type g B Led Display a LED to show a Boolean value Display a picture JPG PNG GIF BMP to show a Boolean value Display a picture JPG PNG GIF BMP to show an Integer value 4 g Trace2 Display a 2 axes x y or 1 axis x Horizontal or 1 axis y Vertical moving trace map gt Draw a Rectangle 6 g Ba Display one value as a bar meter ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Ra
13. Press ON OFF to switch the picture s animation Back to Fox previous page I love to chat with friends in the outdoors Press ON OFF to switch the picture s animation ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 70 70 Dolphin Back to previous page Temperature Setup Can setup a floating integer 25 0 C Back to previous page Precious Index 2 Ate i4 67 poo 100 90 Y gt s 0 70 60 1 B DO1 2 W 30 E 4 1 They are two g B Inp objects User can plug one I 8056 card on the PAC Slot 1 to test the DO switches Setting object to TRUE can enable the picture s animation ICP DAS Co Ltd Technical document
14. set the permission level used when the HMI has the permission setting 12 Ask before operation to ask again before operation 13 Identify Password to re input the password of that level Refer to Ch1 4 for the permission setting ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 39 70 1 3 6 g WD Inp g N Inp g F Inp create a button when user press it it display a keyboard to input a 16 bit signed integer 32 bit signed integer or 32 bit float to the variable Description Show as title Show as value Show as picture 1 2 3 4 5 Location X Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 32 bit Long integer and 32 bit REAL variables defined in the ISaGRAF must occupy two network addresses Refer to chapter 4 2 of the User Manual of ISaGRAF PAC 2 Font size set the font style and size of the text useless in other font setting 3 Fore color the fore color of the object text 4 Size the size of the object W for Width H for height 5 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 6 Show as picture the button is showed as a picture The picture format can be JPG GIF PNG BMP BMP is not suggested due to the large size memory 7 Show as Title show the button as the setting text 8 Show as value show t
15. 0301 gif Battery03 m 031 gif Battery 3 s 0300 gif Battery03 s 031 gif BatteryO4 m 050 gif Battezy04 m 051 gif fa ND des S EB A CT Net Work Address Battery04 s 050 gif Battezy04 5 051 gif FanD1 m 030 gif w FanB1 m 031 gif Font 1 s 130 gif 8 FanD1 s 031 gif w FanD2 m 040 gif 8 FanD2 m 04 D gif FanD2 s 040 eif FenD2 s 04 L gif Fanl3 m M40 ri FanD3 m 04 0 gi FanD3 s 040 gif 8 FanD3 s 04 L gif D EN Location X iso Y Fanl13 m iD417 cif w FenD4 r 060 gif 8 FanD4 m 061 gif 8 FanD4 s 060 gif 8 Fan l4 s 61 gif Fluid D 1 m 40 gif 8 FluidD1 m 041 gif 8 Fluid s 040 gif S Fluid D1 s 041 eif 8 FluidO2 m 070 gif 8 FluidD2 m 071 gif 8 Fluid02 s 070 gif Fluid02 s 071 gif 8 Fluid 3 m 050 gif 8 Fluid 3 m 051 gif LA TA LA rA w rA LA EA a LJ EA rA LA a ie Next create 2 g B Inp objects Drag amp drop a g B Inp object into the editing area Button Tnput x B Inp g WD Inp e F Inp x N Inp g Login e Logout go ToPage Pace Son GRAF Demodt ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 18 70 Mouse right key click and select Setting
16. 70 Use Soft GRAF Studio software to open demo04 sof It shows as below Refer to Chap 1 2 for the steps Set up the upload IP and then upload the project Fil Poet Help 0 wi m ELI gr 0m cn FE es 3 375 yde Lary E ar az zaleas adus r S ER Soft GRAF Demed Please visit www icpdas com Iria a 3 a gt Fag l amp aGRAF gt FAG146 g D z nb A 0c qol wu 002 aF oM ll 70 auo Page z 78000 T FL s EIUS Enn 502 Tz Tom MI Peat 7 H 03 EEE 4 fi Pair PEINE i C 0 eS oan Tam J 5 t SUft GEAF Studio Demoll4 sof x X IP Addxess 132 168 1 165 Project Help ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 62 70 The HMI screen of PAC is as the following picture DemoO04 contains three HMI pages Pagel displays all objects and Page2 amp Page3 display the using of security Pagel Hit Soft GRAF DemoO4 Please visit Time 211 46 1 www icpdas com gt Fag gt SaGRAF gt FAQ146 1 2 1 057kg 3 4 Description and testing 1 Use a Boolean variable to test g B val g B Inp g B Led g B Pic Set the g B Inp as different input type to switch the Boolean variable suc
17. HN 8 1 Project Current Application demo05 ISA11 1516 5412 1132 Elapsed Time S55 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 65 70 This demo default without use I O card If need the I O card user can install an I 8056W in the Slot 1 of the PAC change the i 8056 of the IO Connection setting in ISaGRAF project to Real board re compile project and download it into the PAC The DO control points in this demo will output to the I 8056W card ISaGRAF DEMOOS Programs File Make Project Tools Debug Options Help E HSE Dmm xi ma Gu amp bpESm 20 FA S 0 a j ref 8056 EN r i 8056 m amp DOO addr 20 init True 9 DO addr 21 init True EN i 8055 n amp DOOD addr 20 init True 2 9 DOT addr 21 int True Use Soft GRAF Studio software to open the Demo05 sof as below Refer to Chap 1 2 for the steps Set up the Soft GRAF Studio upload IP and upload the project Refer to Chap 1 7 1 for the steps Ha File Project Help ee x 156 C f mn Project View x 501 y 302 Layer 0 Pagel My Sweet Home To See My Family Page 9 Welcom to the Soft GRAF demo05 Please refer to Fage 10 www icpdas com gt FAQ gt Software gt ISaGRAF gt FAQ 146 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146
18. N Text display a different text by the value of an integer variable Studio PAC Description Value O Value 1 Value 2 Displayed figure OK Enjoy it OKay Have fun I like it too amp i BackColor jJ Font sze D Reeular oH x 4 Location X 184 Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 32 bit Long integer and 32 bit REAL variables defined in the ISaGRAF must occupy two network addresses Refer to chapter 4 2 of the User Manual of ISaGRAF PAC 2 Font size set the font style and size of the text useless in other font setting 3 Size the size of the object W for Width H for height 4 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 5 Forecolor the fore color of the object text 6 Backcolor the back color of the object 7 Align left center and right align for the text 8 Left Text the text displayed on the left side of the object value 9 Right Text the text displayed on the right side of the object value Number Farecalar BackColor 10 New create a new text 11 Edit edit the text 12 Delete delete the selected text ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 30 70 Setting description New Click the New button to see the following setting window Eg N Text
19. s Manual http www icpdas com products PAC i 8000 getting started manual htm Soft GRAF Studio the software to edit the Soft GRAF HMI can run in the PC with the WinXP Win Vista Win7 or compatible Operating System and the Net Framework V 3 5 or later version The current version is 1 01 The execution program is included in the downloaded FAQ 146 zip file After unzip the file please copy the Soft GRAF Studio folder into D The Soft GRAF Studio folder must include the following files as below picture wenn AEL G Demol LJ Demol4 an git Led LJ LogmDemo D e demo pia e apa AW sx 5 EB fagl 46 chinese pd Adobe ahoi Do icument Maia L O86 B eoft GEAF Studia exe i editor att RAF qm YNNEX NZS ptt A i pen ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 3 70 PAC Driver The following ISaGRAF driver versions support Soft GRAF Studio PAC Model ISaGRAF Driver Version WP 8xx7 Ver 1 39 or later VP 25W7 23W7 Ver 1 31 or later XP 8xx7 CE6 Ver 1 19 or later If your PAC s ISaGRAF driver version is later than the version listed above it supports the Soft GRAF Studio However if its version is older please visit the following web site to download the latest ISaGRAF driver into your PAC http www icpdas com products PAC i 8000 isagraf link htm After downloading upd
20. then set Net Work Address as 11 Font Size as 9 Bold and set the same Input color for True and False Net Work Address MO Size 5b 35 Font size Location X 5 B 189 Time False Input VF color EN L Appearance Ca Switch to the Input Setting page key in ON OFF in the Textbox of Show as string and click Ok Show as string ON OFF Switching Time de C Show as value Lu Boolean Falze Ask before operation Boolean True ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Version 1 01 Date Oct 2011 Page 19 70 Author Haven Liu Then create another g Inp object Right click and select Setting to set the Net work address as 11 Font Size as 9 Bold and set the same Input color for True and False ON gt 5 sec gt OFF Met Work Address sie Wong H 35 Font size Location X 150 Y True False Appearance Switch to the Input Setting page key in ON gt 5 sec gt OFF in the Textbox of Show as string select False gt True for Mode Select set Switching Time as 5 Sec and then click Ok C Show as picture Show as string C3 Show as value Boolean False ot Ask before o
21. AQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 56 70 1 6 4 Switch the Soft GRAF HMI page by ISaGRAF program User can declare the below two ISaGRAF integer variables to switch the page of the Soft GRAF HMI and to read the current page number Note Only the Soft GRAF driver version 1 06 and later version supports this function The integer variable which with the network address number 8191 Hex is 1FFF is for switching the Soft GRAF page Please must declare it as internal and assign an initial value 65535 For example as the To Page in the below table If setting it as 1 the Soft GRAF HMI will switch to the Page 1 and then this To page will be reset as 65535 by HMI automatically If setting it as 2 the Soft GRAF HMI will switch to the Page 2 and then the Soft GRAF HMI will reset To Page as 65535 automatically If setting it as a non existing page number the Soft GRAF HMI will not swtich the page The integer variable which with the network address number 8190 hex is 1FFE is for reading the current Soft GRAF HMI page number The value can be 1 2 3 Name Type Attribution NetWork Description Addr To Page Integer Internal 8191 must set an initial value 65535 Hex 1FFF for switching HMI page Current_Page Integer Internal 8190 For reading the current page Hex 1FFE number Inte zer R eal Yariable M ame Ta Fage Network Address I
22. CUTUEES File Edit Project Tools Options Help m sofgr 01 Heference Author Date of creation 20107876 Archive Import IL p imi vil raries 3 ni File Edit Tools Options Help nas Fee lO configurations N llO complex equipments net 1 XP Bxx7 CE6 i functions TZEZIUTTTTNENNNNNNN o stendard WIN32 integration File Edit Options Hel EE a E x C function Wor lt bench Archive format Backup Restore Close Help v Compress Archive location D NCHUX DSSOFGRAFY Browse And also restore soft grf xia into the IO complex equipments of the PC ISaGRAF 33 ISaGR AF Project Management I7 wil A ISaGR AF Libraries Ioj Fie Edit Project Tools Optons Help Ae mg en Eo m hmi 01 Deferenre ES SaGRAF Li bus O00 canz53ll Archive Import IL program braries File Edit Tools Options Help E comple MSolr Back standard note format bus CCB ackup ICP DAs bus ttc can7530 Restore t WIN 22 integration i Fik Edit Tools Options Help DEt be 6 O configurations n to wev do complex equipments to vvv l 7000 amp 87K remote I O X Archive I O complex equipments Workbench Archive Close Help Iv Compress Archive location ow SSUFT BG71 5 Browse 3 ICP DAS Co Ltd Technical document
23. F FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 58 70 1 6 6 To display the Soft GRAF HMI with real FULL SCREEN When complete all design and testing of the control logic and Soft GRAF HMI user may do the following setting to display the Soft GRAF HMI with real full screen This prevents anyone to mis operate the PAC s OS Programs d Taskbar and Start Menu a Always on top oly Favorites d Documents Settings BF Control Panel E Help e Network and Dial up Connections i RUN WS Taskbar and Start Menu m Show die WinPAC Utility 2 0 1 5 r Documents mE etting FTP Sed Save and Reboot Reboot Without Save wW Th Restore Default Settings Exit WinPAC Industrial Control Products S Data Acquisition System How to stop the real full screen When the PAC is setting as Toolbar Auto hide the Soft GRAF HMI will occupy the full screen Then it is not possible to do any operation with the PAC s OS There is two possible ways to solve this problem 1 Recommend using this way PC running ISaGRAF to connect to the PAC and then click Stop application ISaGRAF SOFGR 02 Debugger 1 Zc File Contol Toole Options Help Irts gt Mb RUN allowed 0 current 3 Stop application plication stopped 2 Power OFF the PAC and turn the PAC s Rotary switch to 1 Safe mode Power it up with Safe Mode m
24. FFF Comment set initial value to 65535 Network addr is 8181 Hex 1FFF Ut Conversioni inane Attributes Format nteger standard C Real Shore Internal C Input Cancel C Output C Constant Nent Initial value EEENN Retain Previous didi Dim o Extended ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 57 70 1 6 5 Check Upgrade the Soft GRAF driver version Check the current Soft GRAF driver version click the left top corner of Page 1 This i Page 1 Welcome to the Soft GRAF Demo 01 Please visit www icpdas com gt FAQ gt Software gt ISaGRAF gt FAQ 131 Am v OM gt 5 sec gt OFF Goto Page 2 Upgrade the Soft GRAF driver Soft GRAF driver version 1 01 Sep z1 2010 1 Stop the running ISaGRAF driver XP xx7 CEG ISaGRAF Driver Modbus RTU Slave Port paudrate e imi Current Application n hos I5A1 121956 54122376 Delete Elapsed Time 00 3215 2 Download FAQ 146 http www icpdas com fag isagraf c htm gt 146 and copy the file Soft GRAF exe in the faq146 demo chinese zip to the directory of system_disk isagraf in the PAC via ftp or USB disk method replace the old file Soft GRAF exe ICP DAS Co Ltd Technical document Classification ISaGRA
25. ISaGRAF programming please refer to the Ch1 1 Ch1 2 and Ch2 of ISaGRAF Advanced User Manual The manual website is as below http www icpdas com products PAC i 8000 getting started manual htm Open your project or create a new one ex demo01 click the I O Connection tool icon of the programs window File Make Project Tool Debug Options Help Ey mie EE D mE fm xi Set soft grf to the Slot and the slot number must after 8 inorder not to conflict with the real I O using slots of PAC 8 _3 soft gri w E Setting n o4 Select board fequpment x Bkdpr l 7000 Os on Coma or COMA ike Link EKE 4 MTCF or SRES MTEP key init Set keypad features Icd ini Set LCD features Cancel mbus Modbus ATU master mbus ase Modbus ASCI master Tae mbus tcp Modbus TCP IP master FAG 11 mmican Connect MMICON by Coma ar Con modem ps Set Password of Com Modem rdn Redundant System For Wincor Library rdn new Mew Redundant 5ystem W Bur rtu slav 2nd 5th Modbus ATU slave port Bosses ry slvz B 8th Modbus ATU slave part m s206 512 Batten backup SRAM far I 8zx Equipments sms Short Message Service a soft qr enable the Soft GAAF Then create a new LD Ladder program in the project so File Make Project Tools Debug Optons Help E mH Oa xe mo Create new program Hew Program Comment for faq 46 Language Quick LO Ladder Diagram ig Sye E m ex D Em xt
26. SaGRAF software user can manually set the Boolean to True to clear the trace curve If its network address is not within 1 8191 the clearing function will not enable 5 Size the size of the object W for Width H for height 6 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 7 Left Limit set the left limit of the X axis in the trace map 8 RightLimit set the right limit of the X axis in the trace map 9 Lower Limit set the bottom limit of the Y axis in the trace map 10 Upper Limit set the upper limit of the Y axis in the trace map ae an 18 11 show scale check box to show the border of the axis and its scale 12 X Division if show scale is checked it means displaying the current position value at the bottom and divide the X axis by this integer value 13 Y Division if show scale is checked it means displaying the current position value at the bottom and divide the axis by this integer value 14 Font set the font style and size of the text useless in other font setting The maximum size is 10 and the minimum is 6 for this object 15 Back Color the backcolor of the trace map 16 Trace Color the color of the trace curve 17 Board Color the color of mesh and border 18 Point Color the color of the current point ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 44 70
27. True Set to show different message when False and True Size aa iH 40 Location X ipp K 128 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 15 70 Drag amp drop a g B Pic object to the editing area Sot GRAF Demo 01 Page 1 Set up the picture of True File for True The picture can be gif dynamic image format The demo picture can be got from the Picture gif directory of the demo file faq146 chinese demo zip Refer to Ch 1 5 for more about the dynamic image format uuuumuununuunnuuuuunusauuuuuuus Net Work Address 0 Location X mu fE Irue File Ha Fic ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Haven Liu Version 1 01 Date Oct 2011 Page 16 70 Select Fan03 m 041 gif file and click Open O solos OE e BRUCE Battery m 020 gif 8 Battery m 021 gif Battery s 020 gif me Battery l1 s 021 gif BattezyD2 m 050 gif 8 Battey 2 m 05 1 gif 5 Battery02 s 050 gif Battexy 12 s 0513 gif Battery3 m 030 gif Battery03 m 031 gif Battery 3 2 030 gif Battery 3 5 031 gif Battery04 m 050 gif Battery04 m 051 gif L4 H
28. animated picture a y iP ia wD di J A User can find the default burned in pictures in the following CD ROM or web site WP 8xx7 CD napdos isagraf wp 8xx7 driver wp 8x47 1 37 sofgrafy XP 8xx7 CD napdos isagraf xp 8xx7 ce6 driver 1 18 sofgrafy VP 2xW7 CD napdos isagraf vp 25w7 23w7 driver 1 29 sofgrafy or www icpdas com gt FAQ gt Software gt ISaGRAF gt FAQ 146 in the downloaded ZIP file ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 51 70 1 6 Other Features introduction The Soft GRAF Studio provides the Clipboard and the function of arranging the object layer order 1 6 1 Use Clipboard Feature to Copy the HMI Object The clipboard allows there stardard commands Cut Copy amp Paste 1 Using the hot key Ctrl X Cut the object Ctrl C Copy the object Ctrl V Paste and replace the object after the Cut or Copy Operation Example Mouse left click on the object then press keyboard Ctrl X or Ctrl C Press Ctrl V to paste the object 2 Using the tool icon Use the clipboard icons in the tool box Operation Example Mouse left click the object then the icon Cut or Copy and then the icon Paste uw E E File Project Help MRES AE ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Vers
29. ate the driver into the correct model of PAC Please click on End Driver button in the ISaGRAF driver window of the PAC s VGA screen to end the ISaGRAF driver first then unzip the downloaded file and copy all files and the sub directory in the related version number directory to the System_Disk ISaGRAF path in your PAC via FTP or USB disk For instance to update the ISaGRAF driver of XP 8xx7 CE6 to Version 1 19 please click on the End Driver button in the ISaGRAF driver window of PAC then unzip the downloaded file xp 8xx7 ce6 1 19 zip and copy all files and the sub directory sofgrafy in the 1 19 directory to the System_Disk ISaGRAF path in the XP 8xx7 CE6 And then reboot the XP 8xx7 CE6 Now the driver of the PAC is updated WinPAG 8x47 8x46 Gxa7 exa6 ISaGRAF Driver Setting weh About Configuration Slave Mumber m Modbus RTLI Slave Port one Baud Rate fig2o0 RM 8 1 Project Current 4pplication demot4 ISA11 1384 15412 916 Elapsed Time baaz ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Haven Liu Version 1 01 Date Oct 2011 Page 4 70 Next retore the file sofgrafy uia that downloaded unziped from the FAQ 146 of faqi46 chinese demo zip into the c functions of the PC ISaGRAF as below AM ISaGRAF Project Management ER FX
30. aximum 120 overnlow 0 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 59 70 1 6 7 File management for user edited pictures Picture files in the PAC All user used pictures in the project will be stored in System_Disk ISaGRAF sofgrafy user directory after upload into the PAC If there are too many pictures and you want to manage them you can delete all the pictures files under System_Disk ISaGRAF sofgrafy user But do not delete the folder user and upload pictures again via Soft GRAF Studio Address System _DiskISAGRAF sofgrafyiuse a 07 ipg 14 1KB JPEG Image aa 08 ipa 13KB JPEG Image a air 021 gif 9 75KB GIF Image a air 1 jpg o 29KB JPEG Image aa back ipa 4 14KB JPEG Image a back b jpg 4 16KB JPEG Image For saving the upload time Soft GRAF checks the file name and size when upload the project to the PAC to decide overwrite that file or not If the file size is the same it will not upload that file So when the picture of HMI screen is not update please delete the non updated files in the System_Disk ISaGRAF sofgrafy user of the PAC and then upload the project again via Soft GRAF Studio Picture files in the PC Soft GRAF Studio Normally the Soft GRAF Studio will copy all user edited picture files to the D Soft GRAF Studio lt project name gt pic dire
31. ciment or in a project right click on the HMI editing area then select Help omm About Fasel File Project 9 uH Project View The origin of Soft GRAF Studio axis in the Soft GRAF Studio editing screen is at the top left of the axis position as follows 0 0 X Y The horizontal axis of the monitor is called X axis while vertical axis is called Y axis The original position of X Y is O 0 which resides at the most top left position on the monitor The value of X coordinate is increasing from left to right direction The value of Y coordinate is increasing from top to bottom direction The unit of the X Y coordinate is Pixel For example the default resolution setting of the WP 8847 is 800 x 600 so its X coordinate ranges from O to 799 while ranges from O to 599 for Y coordinate The default resolution setting of the VP 25W7 is 640 x 480 so its X coordinate ranges from O to 639 while ranges from O to 479 for Y coordinate 1 2 1 Edit a simple Soft GRAF HMI The following picture is the VGA Screen view when run Demo01 Soft GRAF Demoli ON OFF OM gt 5 sec gt OFF Goto Page 2 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 8 70 Before editing HMI page ISaGRAF must have the following setting If you are not familiar with
32. ctory when using them If user wants to modify the picture file please close the Soft GRAF Studio first then edit the picture file in the D Soft GRAF Studio lt project name gt pic directory ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 60 70 1 7 The description of some Soft GRAF Studio demo projects 1 7 1 DemoO04 display the Objects and the HMI access This demo displays all HMI Objects and basic operation First restore demo04 pia and upload it to the PAC 384 ISaGRAF Project Management File Edit Project it Options Help Pu Em sofgr 08 Libraries Common data Em sofgr 09 Import IL program rta www icpdas cor T fsnesnesnz II minam onm rm nfnr fil Archive Projects x Workbench Archive i demoll4t demal5 Restore Close Help Iv Compress Archive location DNSOFT Browse ISaGEAF DEMOUM Program File Make Project Tools Debug Options Help CORE SIME SCR fleet dB RUE gu Begin WinPAGC 8x477 8x40 8x377 8x36 ISaGRAF Driver Zst Configuration Slave Mumber f Modbus ATU Slave Port ione Baud Rate rs200 A 8 1 Project Current Applicatio dernon4 I541121384 15412 916 Elapsed Time n 0 12 36 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 61
33. ddress for the variable 32 bit Long integer and 32 bit REAL variables defined in the ISaGRAF must occupy two network addresses Refer to chapter 4 2 of the User Manual of ISaGRAF PAC 2 Font size set the font style and size of the text useless in other font setting 3 Fore color the fore color of the object 4 Back color the back color of the object 5 Size the size of the object W for Width H for height 6 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 7 Align left center and right align for the text E M M 10 8 mal Original Value oo 11 Em Value after 9 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 28 70 8 Conversion check to convert the value the g F val can input the decimal value 9 Original value the range of the original value read Ex 0 32767 07 65535 etc Value after the range of the value after conversion Ex if the Original value is 032767 and the Value after is 01000 that means to convert the value from range of 032767 to range of 01000 such as 16384 is converted to be 500 10 Dot define the number of digits displayed after the for the number after conversion or the conversion not to use Ex Set Dot as 3 the original value 32767 will be disp
34. e fore color of the value when ISaGRAF read it False 4 Size the size of the object W for Width H for height 5 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 32 70 pee common Input Settmg show as picture o ee C3 Show az value Mode Select Noms v select Narmal switching Time EN SEC 8 Boolean True 6 Show as picture the button is showed as a picture The picture format can be JPG GIF PNG BMP BMP is not suggested due to the large size memory 7 Show as string show the button as the setting text 8 Show as value depand on the value that Soft GRAF read to show thereplaced text Boolean False the text is showed when the read number is a False boolean Boolean True the text is showed when the read number is a True boolean 9 Mode select the input mode of the Boolean There are 5 modes a Normal can input True or False b Only False False only c Only True True only d True False True first and switch to False after a setting time e False True False first and switch to True after a setting time 10 Switching Time if select the Mode of False True or True False set the switching time here The time unit is secent and range is 1710 secents 11 Level
35. eration 8 Ask message the text in the pop up window of Ask before operation 9 Deny message the message will show when the user Level is too low to access the switch page Its default message is Access denied if left it blank 10 To Which Page the page want to switch to 11 Title the text displayed on the object ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 38 70 1 3 10 g B Led can display a LED picture to show a Boolean value 1 Net Work Address 5 crop 6 en feros mmis 5 Lo 3 Won Eo Pom 8 4 Location Kus iio Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 2 Input T F Color the color of True displays the fore color of the value when ISaGRAF read it True The color of False displays the fore color of the value when ISaGRAF read it False 3 Size the size of the object W for Width H for height 4 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 5 Message when False the text showed on the object when read a False value 6 Message when True the text showed on the object when read a True value 7 shape set the Led shape can be rectangle or ellipse 8 Font size set the font style and size of the text useless in other font setting ICP DAS Co Ltd Technical document
36. h as press the button ON 5 sec gt OFF can set the Boolean to True for 5 seconds and then set it to False 2 Switch to Page2 3 Display the Trace function draw the curve according to the read value Setting the Action Address can select the way to draw and setting the Clear Address can clear the curve by manual In the HMI Page2 user can press the button Clear to clear the trace curve 4 Display a Bar meter b Ag N Text object display the specific text according to the read value 6 The buttons set a Word Integer or Float value from up to down 7 Press the login button can go to Page2 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 63 70 Page2 1 g_ToPagel with levelz security pls login as level 2 or Higrt user ta operate it Goto Pages 5 g F inpwith levelz security pls login as level 2 or Higher user to operate it G g F inpwith level 1 security pls login as level 2 or Higher user to operate it a 1 Press the button to go to the Pagel 2 Log out If login from the Login button of Pagel and login successfully press this button can return to Pagel and logout 3 This is a g_F_Inp object with the level 2 authority protection If user does not login with the Level 2 or upper Level password that setup in the Soft GRAF Studio designing step user cannot i
37. he value that ISaGRAF read ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 34 70 common vetting Deus 11 9 Teese 2 Umm as 10 9 Limit setting set the up low limit of the input value 10 Alarm string a pop up window text when user input a value beyound the limit Low limit the text when the input value is lower than the Low limit Up limit the text when the input value is higher than the Up limit 11 Level set the permission level used when the HMI has the permission setting 12 Ask before operation to ask again before operation 13 Identify Password ask to re input the password of that level ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 35 70 1 3 7 g_Login Create a Login button This object creates a Login button When users press it a keyboard will display and request the user to key in a password There are maximum 12 characters in a password only number O to 9 This g Login object can only put on the Page No 1 and only one g Login allowed When user presses the g Login button the Soft GRAF driver in the PAC will read a password file to check if this is a valid user who has a permission level 1 10 and the larger number has the higher autho
38. hewltem a a b m Ho NE c BackColor f a Number if read this integer value the object will display the setting text Max 50 numbers from 0 49 b ForeColor the fore color of the text c BackColor the background color of the text d Blink check to blink e Text the text to display f Add click to add this setting Edit Select the item want to edit then click Edit to open the setting window After edit click Add to save it If forget to select any item it will open the first item s window common setting eetting IN Delete Select the item want to delete then click Delete to delete it If forget to select any item it will delete the first item common setting Setting ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 31 70 1 3 5 g B Inp create a button when user press it it display a keyboard to input a Boolean to the mapping ISaGRAF Boolean vaiable Description Show as string Show as value Show as picture True Displayed figure Options 1 Net Work Address the ISaGRAF Modbus Network Address for the variable 2 Font size set the font style and size of the text useless in other font setting 3 Input T F Color the color of True displays the fore color of the value when ISaGRAF read it True The color of False displays th
39. ill Ta RAT 8 BattezyD4 s 050 gif BattexyD4 s 051 gif FanD1 m 030 gif Fan m 0313 if Fen s 30 gif Fand s 031 aif IS FenD2 m 40 gif 8 FanD2 m 04 1 gif FenD2 s 040 git Fan2 s 041 gif Fen 3 m 040 ai Imi mE m i 41 Fan 3 s 040 st FenD3 s 041 gif FanD4 m 060 gif FanD4 mn 061 gif FanD4 s 60 gif FenD4 s 61 gif Fluid m 040 gif 8 Fluid m 04 12 gif 8 Fluid O1 s 040 git S Fluid D s 04 1 gif Fluid 02 m 070 gif FluidD2 m 071 gif 8 Fluid 02 s 070 git Fluid02 s 071 gif Fluid 03 m 050 gif Fluid 03 m 051 gif EAEACACACACACA XE mi FX BED e Set False File as Fan03 m 040 gif Then set Net Work Address as 11 and click ok to exit Net Work Address mize CMM Location X iso F Tine File False File FenD3 m 041 8f wq ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Haven Liu Version 1 01 Date Oct 2011 Page 17 70 Tal O eif v Qi em PE T aea FH AE mize Battery01 m 020 gif Battery m 021 gif Batteryll s 020 gif Battery01 s 021 gif 5 Battezy 12 m 050 gif Battezy 2 m 051 gif 8 Battezy012 s 0500 gif Battery02 s 051 gif 5 Batters 3 m
40. ion 1 01 Date Oct 2011 Page 52 70 3 Using the mouse right key Mouse right key click on the object then select the Cut or Copy from the popup menu Then mouse right key click on the blank editing area and select the Paste Cut or Copy the object 1 6 2 Use Clipboard Feature to Paste the Text into HMI Object After copying the text mouse left click the box of Title in the HMI then mouse right click and select the Paste x Common Net Work Address Size 22 H a4 Font size Location X 597 Y 220 1Z Regul Fore Color mm Text Align Center Back Color Title amp Eg U Ey f T Ok Cancel ES C B FO FRU DJ EE ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 59 70 1 6 3 Adjust the Objects order Soft GRAF Studio offers the function to adjust the layer order of the object The first created object in the Soft GRAF Studio default has the highest level Layer The higher Layer object is above the lower Layer object when the objects overlap with others User can change the Layer level to use the overlapped object When you click an object its layer level and position will show on the left up corner of the HMI editing area the larger number Layer with the higher level 12276 y 85 Layer 2 5 g WO Val ETIE Operation Example
41. layed as 32 767 11 Left Text the text displayed on the value s left side 12 Right Text the text displayed on the value s right side Common settme 1 setting d e 13 4 7 Enable limit detection Up Limit Message Up Limit Up Limut 327 67 Low Limit Message gt Low Limit 327 68 l 16 Blink Blink Normal v Up LinitColor a 1 Limit Color 19 13 Enable limit detection check to enable the up low limit detection 14 Up limit the upper limit value to detect 15 Low limit the lowest limit value to detect 16 Blink select to blink or not when the value is inside outside the limit range 17 Up Limit Message when the Enable limit detection is checked the message will show up if the value is larger than the Up Limit 18 Low Limit Message when the Enable limit detection is checked the message will show up if the value is lower than the Low Limit 19 Up limit Color when the Enable limit detection is checked the text color and background color will show up if the value is larger than the Up Limit 20 Low limit Color when the Enable limit detection is checked the text color and background color will show up if the value is lower than the Low Limit ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 29 70 1 3 4 g
42. nput this Float value For test this button please go to Pagel press the button Login and enter the password 012345 then the system will go to Page2 automatically and then user can press this button to change its value 4 The function is the same as 3 For testing go to Pagel and enter the Level 1 or Level 2 password 5 Switch to Page3 This button the same with the authority protection switches to Page3 only when the user logins in with the password of Level 2 or upper level Page3 1 Switch to the Page2 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Version 1 01 Date Oct 2011 Page 64 70 Author Haven Liu 1 7 2 Demo05 My Sweet Home Demo Description This demo shows how to design an interactive and dynamic HMI page Restore demoO05 pia and upload to the PAC A ISaGRAF Project Hanagement Fie Edit Project SES Options Help e Eg sofgr 8 Eg sofgr 09 rm enfnr fil Archive Projects x Workbench Archive demols Restore Libraries Common data rto wew ijcpdas col T farsi deeds nnm Import IL program Help Iv Compress Archive location D SSOFT Browse ISaGRAF DEMOOS Programs File Make Project Tool Debug Optons Help aP OG OS K mia i gu Generate a pulse M1 and get Time Begin Configuration Slave Number Modbus ATU Slave Pork hone Baud Rate jis2o0
43. ogout g Logout 1 5 2 3 4 Options 1 Font size set the font style and size of the text useless in other font setting 2 Fore Color the fore color of the object text 3 Size the size of the object W for width H for height 4 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 5 Title the text displayed on the button ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 37 70 1 3 9 g_ToPage Create a switch page button Show as picture Description Show as text Displayed figure Franca o ee Fe E o 9 To Which Page n 10 5 Au in UN pe Options 1 Size the size of the object W for width H for height 2 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 3 Font size set the font style and size of the text useless in other font setting 4 Fore Color the fore color of the object text 5 Level set the permission level used when the HMI has the permission setting When user s login permission level is higher than this level the user can access the function 6 Appearance show the object by a picture The picture format can be JPG GIF PNG BMP BMP is not suggested due to the large size memory 7 Ask before operation to ask again by a pop up window before op
44. peration a el ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 20 70 Next create a g ToPage object Drag amp drop a g ToPage into the editing area rage l Soft GRAF Demodt ON gt 5 sec gt OFF Goto Page H u Set Size W as 100 Size H as 25 Font size as 9 Bold Fore Color as the below picture To Which Page as 2 and Title as Goto Page 2 F Ask before Ask message Request message ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 21 70 Mouse right clicks Demol1 sof in the Project structure tree and select New Page to create page 2 The Page Setting can be left along just click Create Project Pazesething Title Back Color Encode Click Page 2 to switch to the page 2 Project Demol sof Page 1 T Drag amp drop a g ToPage into the page 2 for return the page 1 Page 2 Button Input z B Inp Go To Page 1 g WD Inp e F Inp Eg N Inp g Logout Ao a8 ja 5 3 E E e ToPage ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 22 70
45. py two network addresses Refer to chapter 4 2 of the User Manual of ISaGRAF PAC 2 Size the size of the object W for Width H for height 3 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis mm Murmber B Picture 4 Delete 6 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 41 70 4 New open a setting window to add a new picture 5 Edit edit a picture setting 6 Delete delete a picture Setting description New Click the New button to see the following setting window Eg N Pic Newltem a Number if read this integer value the object will display this setting picture Max 50 numbers from 0 49 b Picture the picture s file name to display c Add click to add this setting Number Picture SUE SINT Edit Select the item want to edit then click Edit to open the setting window After edit click Add to save it If forget to select any item it will open the first item s window Delete Select the item want to delete then click Delete to delete it If forget to select any item it will delete the first item ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 42 70 1 3 13 g_Trace2 display a 2 axes x y or 1 axis x Ho
46. rity Refer to Ch1 4 for the permission setting Login Toging Set 1 Font size 5 a s 3 SIZE W75 H Deny Message 7 4 Location X 357 Options 1 Font size set the font style and size of the text useless in other font setting 2 Fore Color the fore color of the object text 3 Size the size of the object W for width H for height 4 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 5 Title the text displayed on the button 6 Switch page the number of page want to switch to when login successfully 7 Deny message the message want to display when the login fail 8 Wait time the period of time to auto Logout The unit is second The value can be 0 and 10 3600 0 means do not enable the auto logout Need to press the g Logout button to logout Ex set the wait time as 60 Soft GRAF will auto logout and switch to the first page if user has not any operation over 60 secents after login the HMI ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 36 70 1 3 8 g Logout Create a Logout button This object can create a Logout button When user presses the button it pops up a confirmation dialog If user answers Yes the Soft GRAF will logout and switch to the first Page Page 1 Refer to Ch1 4 for the permission setting L
47. rizontal or 1 axis y Vertical moving trace map 5000 OT TT T T T T 3H 62500 12500 125000 250000 12500 25000 Please drag the object into the editing area and select one of the axis options Only x axis Only y axis x and y axis g IraceNew E 1 X Axis Address 2n 3 ca 5 6 Location ip 5o Y Fps Options 1 X Axis Address the Network addr of ISaGRAF variable for the X axis 2 Y Axis Address the Network addr of ISaGRAF variable for the Y axis 32 bit Long integer and 32 bit REAL variables defined in the ISaGRAF must occupy two network addresses Refer to chapter 4 2 of the User Manual of ISaGRAF PAC 3 Action Address the Network addr of ISaGRAF Integer variable 0 no drawing type O stop 1 drawing both of trace curve and the current point type 1 drawing both 2 drawing only the current point Not within 1 8191 the same as type 2 drawing only the current point 4 Clear Address a ISaGRAF Boolean variable Its network address can be 1 8191 Left Limit ip Right Limit 1000 Lower Limit Upper Limit ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 43 70 If the Boolean is True the trace curve is cleared once and then Soft GRAF will change the Boolean to False automatically In I
48. th set up the border line s width 1 10 4 Rect Color set up the border color of the rectangle ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 47 70 1 4 How to set up the access permission of HMI The Soft GRAF provides a password setup for the HMI security please refers to the following steps The HMI password security is accomplished by the menu of Project gt password and two HMI objects g Login and g logout The Setting Steps 1 Open a project of the Sort GRAF Studio and lick the Project Password Upload 2 Set the password and level a All Password b Password b aye 123456 Level 2 123456 a Level the security levels can be Ho NULL 1 10 The larger number has the id NULL higher authority Click the button ee NULL Level 6 NULL to see the setting passwords ze for all levels NULL means that em level doesnot set password Aet b Password the password of the selected level 3 Create a new password first select a Level If this level has no password yet it is blank Then key in a password and click Create PassWordDlg Level Password 4 Change Delete password select the Level that wants to change The password column will show the current password Key in the new password and click Create to replace the password If user wats
49. the read ISaGRAF value is False 5 Size the size of the object W for Width H for height 6 Location the X Y axis of the object Refer to Ch 1 2 for how to display the axis 7 Align left center and right align for the text ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 26 70 8 Left Text set up the text displayed on the left side of the object value Ex If set the Left Text as Status the object will show Status True when the ISaGRAF Boolean value is True 9 Blink Set the object text to blink No Blink text not to blink Blink when true blink when the value is true Blink when false blink when the value is False All Blink blink when the value is True or False 10 11 the message to display when the value is True False ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 27 70 1 3 3 g WD val g N val g F val Display a 16 bit Integer 32 bit Integer or 32 bit Float value Studio PAC Description Set text Show text only Show text amp value Show value only Displayed figure g_N_Val O5 2 Font size Location X 7 6 o e vp o 4 Options 1 Net Work Address the ISaGRAF Modbus Network A
50. to delete the password please click Delete ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 48 70 5 Inthe HMI editing area drag the g_Login object into the Page 1 Page 1 Button Input amp B Inp g WD Inp z F Inp g N Inp ri 3 d H g Login z Logout z ToPage 6 Right key click on Login button select Setting and then enter the page number that want to switch to for the Login button Enter page number 2 for this demo Font size GResular Title Fore Color C Switch page Size Ws B Deny Message Location X 4g jY Wait Time ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 49 70 7 Switch to Page 2 and drag the g Logout object into the editing area Now this page is protected by the password security Project LogimDemo sof Page Page 2 Button Input x B Inp g WD Inp E F Inp x HN Inp g Login g Logo E amp ToPage 8 Upload the project to the PAC Click the Login button and enter password can login the HMI project Click Logout button can exit the HMI project ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 50
51. ve a project name and file location Hew File Setting Project Name Location Donen at tig Docendi Project file location PAC Select PAC amp VGA resolution To open a file Click File gt Open of menu bar Soft GRAF HMI Editor File Project Help Fr Li fake CA NE ta ND Demol sof v R ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Haven Liu Version 1 01 Date Oct 2011 Page 11 70 Now create a HMI page The following HMI is the same as the Demo01 please set all the Network address in this project as 11 the address is the same as the Boolean variable LED 01 in ISaGRAF program First create a g Label object Drag amp drop g Label object into the editing area Project View Page 1 Label Value v Click Font size to set up as 10 Bold Common Net Work Address Fore Color Font size S Rege mum Back Color ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 12 70 ARRE s m cp eS 2 5 PN FRE Set up the Object Size as W 300 and H 60 Common Net Work Address mize 300 Hen Font size Location xX 102 Fore Color L Text Align Center w om Back Calor
52. ven Liu Version 1 01 Date Oct 2011 Page 6 70 1 2 Edit the HMI by the Soft GRAF Studio software To test Soft GRAF Studio demo projects please refer to Ch 1 7 1 and the description for demo4 and My Sweet Home demo in Ch 1 7 2 To execute the Soft GRAF Studio please double click the D Soft GRAF Studio Soft GRAF Studio exe If Soft GRAF Studio exe doesn t found please refer to Ch 1 1 to install it The software operating environment Soft GRAF HMI Editor PESE E s gt For basic file operating password E _ baa i a setting upload IP configuration HMI Tool Bar HMI Page Editing Area Display and switch the project HMI pages One Soft GRAF project can contain maximum 200 HMI pages No 1 to 200 The PAC will display the Page No 1 if it has enabled the Soft GRAF in the program when powering it up Every Page is displayed as full screen and only one Page is shown on the VGA monitor so user must set up the VGA resolution when create a new project The PAC Resolution PAC Support VGA Resolution XPAC 640 480 800 600 1024 768 WinPAC 640 480 800 600 VP 25W7 640 480 VP 23W7 320 240 ICP DAS Co Ltd Technical document Classification ISaGRAF FAQ 146 Author Raven Liu Version 1 01 Date Oct 2011 Page 7 70 Soft GRAF Studio offers two ways to use the manual to query the functures Click the menu bar Help gt Do