Product Datasheet

image

Contents

1. BBK 4052 3 Page 2 Dimensions 2 16 gt s 2 94 gt 55 mm 75 mm 4 33 P 110 mm m Wiring SDS Power Activity Error BusBlock Module 4 Channel 0 10V 0 20mA Analog Input BBK AIN104 2 ea I e i B 2 Wire 7 Sensor Holjeron e 25599 SW 95 Ave Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com Holjeron smart moves BBK 4052 3 Configuration Tools A BusBlock module can be configured us ing several tools The information below summarizes the configuration tools avail able and hardware requirements for each tool Holjeron Device Manager for SDS Requires an HSIM Portable RS 232 to CAN converter that connects to the serial port of a personal computer The bus or the HSIM Portable must have power Honeywell hand held activator The Honeywell activator may not supply enough power by itself The SDS bus might require external power to be ap plied Think amp Do Software Requires a Honeywell PC Interface Card with separate bus power Follow the in structions for installing the SDS Driver in I O View BusBlock Analog Input Module Page 3 Quick Start The following steps are the minimum steps to configure BusBlock module Default values are shown in bold type face for the Smart Distributed System TECHNICAL DATA Set Device Address Using one of the to
2. Holjeron smart moves BBK 4052 3 Description The Holjeron BusBlock Analog Input Module is designed to handle small amounts of analog inputs in a limited amount of space The BusBlock Analog Input Module has four channels with each channel using bus power to power the analog device being connected Each input can be either a separate SDS ad dress or can be configured to be four embedded objects within a single SDS address Field terminations are captive screw ter minals Each input has its own LED indi cation for immediate verification of I O states Other BusBlock products include an eight point configurable digital module as well as analog output and frequency modules Warranty Remedy Seller warrants its products to be free from defects in design material and workmanship under normal use and service Seller will repair or replace without charge any such products it finds to be so defective on its return to Seller within 18 months after date of shipment by Seller The foregoing is in lieu of all other expressed or im plied warranties except title in cluding those of merchantability and fitness for a particular pur pose The foregoing is also pur chaser s sole remedy and is in lieu of all other guarantees obligations or li abilities or any consequences inciden tal or punitive damages attributable to negligence or strict liability all by way of example While Holjeron provides application assis
3. The IOERR diagnostic is enabled when the microprocessor on the BusBlock en counters communication errors with the A D converter IOTIM An IOTIM diagnostic occurs when the mi croprocessor requests new data from the A D converter and does not receive a re sponse LOLIM A LOLIM diagnostic is generated when the scaled input value is at or below the Low Limit set in attribute 69 HILIM A HILIM diagnostic is generated when the scaled input value is at or above the High Limit set in attribute 71 Holjeron e 25599 SW 95 Ave Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com BBK 4052 3 Attributes Actions Events Holje ron smart moves o ce 410 0l o0 Oo c o0 Page 6 Description Network Data Descriptor Baud Rate Object Model Vendor Id Logical Address Un solicited Mode Software Version Diagnostic Counter Diagnostic Register Cyclic Timer Serial Number Date Code Catalog Listing Vendor Description Input Variable Manufacturing Codes Tag Name Number of Channels Used Enable Object Mode Enable Limiting Service Time Service Life Change of Value Deadband Input Range Input Low Limit Input Low Scale Input High Limit Input High Scale Raw Analog Data Description NOOP Change Address Self Test Clear All Errors Enroll Logical Device Change Baud Rate Force State Unforce State Read Attribute Descriptor Password Reset Factory De
4. disable change of value No piscibus events Unsolicit Mode 0 or use the Cyclic Timer Attribute 10 by setting it to some non zero value The Cyclic Timer will transmit the input variable on an inter val equal to the value in the Cyclic Timer attribute times 10 milliseconds 0 01 sec onds Holjeron e 25599 SW 95 Ave Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com Holjeron smart moves BBK 4052 3 Diagnostics The Diagnostics Register attribute 9 is two bytes and contains the minimum di agnostics required for the Smart Distrib uted System plus additional diagnostics specific to the BusBlock Analog Input module Diagnostic Register Bit Definitions Byte 0 Bit Name Description 0 CHKSUM ROM checksum error 1 WDOG Output watchdog timer expired 2 BUSOFF Off us communications error 3 DEVERR Fatal component error 4 NODE Missing node detected 5 RSVD Reserved 6 RSVD Reserved 7 EPRM EEPROM error de tected Diagnostic Register Bit Definitions Byte 1 Bit Name Description 0 SRVLIFE Service Life exceeded 1 RSVD Reserved 2 IOERR l O error 3 IOTIM l O Timeout 4 LOLIM Low Limit 5 HILIM High Limit 6 RSVD Reserved 7 RSVD Reserved SDS host controllers are equipped to re ceive a diagnostic event then automati cally obtain the information from the Di agnosti
5. Mod ule Whenever an event is generated that reports the state of inputs the data in at tribute 18 will be passed Input Type oer The digital value resulting from the A D Note conversion is stored in Raw Data at y tribute 80 When using a packaged control sys A D Conversion li tem such as Think amp Do Software it is Attribute 80 Scaling not necessary to explicitly read input The Low Scale attribute 70 is the value and output variables The SDS I O Y to be transmitted over SDS when the in Driver and Interface Card perform this poe coming analog signal is at 0 volts or mil function All that is required is to map inputs and outputs as described in the software user manual Change of Value Deadband A Change of Value Deadband attribute 65 can also be set This will limit events from being sent unless the input variable changes at least as much as the value entered in the Change of Value Dead band This prevents insignificant changes in the input variable from generating events on the bus The default value for the Change of Value Deadband is 16 Low Limit the High Limit attribute 71 If the ac No i H pocas tual value falls outside the bounds of the Input Event Mode No Most systems will require a BusBlock I O Module to generate an event whenever one or more inputs change state This re quires the Unsolicit Mode attribute 6 Y be enabled by setting its value to 1 Other High Limit options are to
6. c Register attribute 9 Consult the documentation for the host controller being used to determine how errors are handled BusBlock Analog Input Module Page 5 CHKSUM A ROM checksum error is generated on power up if there is a memory error test WDOG The Output Watchdog Timer is not active in the BusBlock Analog Input module BUSOFF The CAN controller on the BusBlock module counts error messages Every er ror message increments a counter by 8 every good message decrements the counter by 1 If the counter reaches 128 then the module will go BUSOFF and will need to be reset by the host controller DEVERR The DEVERR diagnostic bit will be set if a fatal error is detected within the compo nent NODE The host controller will report the node is missing using the NODE bit EPRM The EPRM error will occur when the mi croprocessor on the BusBlock module is unable to read or write EEPROM for the Smart Distributed System TECHNICAL DATA SRVLIFE BusBlock modules are equipped with two attribute settings for managing the service life of the module The first Service Time attribute 63 is the number of hours the module has been in operation The sec ond Service Life attribute 64 is set by the user and is the number of service hours before the unit requires mainte nance and or replacement When the Service Time value reaches the Service Life setting then an SRVLIFE diagnostic is transmitted IOERR
7. faults Description Diagnostic Event End of Timer Change of Value BusBlock Analog Input Module for the Smart Distributed System TECHNICAL DATA Data Type Size Count _ Default Unsigned Byte 3 18 04h 40h Unsigned Byte 1 0 autobaud Unsigned Byte 5 1 2 5 1 2 Unsigned Word 1 9 Holjeron Unsigned Byte 1 125 Boolean Undef 1 1 Character Undef 12 Unsigned Byte 1 Unsigned Byte 2 Unsigned Word 1 0 Unsigned Long 1 Character Undef 4 Character Undef 32 BBK AIN104 Character Undef 32 Holjeron Character Undef 32 4 Channel Analog Input zzz2222222zzoozzzoosnszozoz2n220m Signed Word 1 Unsigned Byte 1 0 Character Undef 32 Unsigned Byte 1 4 Boolean Undef 1 0 Boolean Undef 1 0 Unsigned Word 1 Unsigned Word 1 5000 Unsigned Word 1 16 Boolean Undef 1 0 current mode Signed Word 1 0 Signed Word 1 0 Signed Word 1 32767 Signed Word 1 32767 Unsigned Word 1 Request Data Response Data New logical address Vendor Id Serial Number New baud rate 0 4 Input Variable Attribute Id Attribute Id Attribute Descriptor Password Event Data Number of diagnostic bits set in Attribute 9 Attribute Input Variable Attribute Input Variable Holjeron e 25599 SW 95 Ave Suite E e Wilsonville OR 97070 e 503 582 0820 Fax 503 582 9166 e www holjeron com
8. ols described above change the device address from the de fault All units are shipped from the fac tory as address 123 126 Note Set the address before attaching any component io a complete bus This will help prevent duplicate addresses on a bus The default addresses are Channel 1 Address 126 Channel 2 Address 125 Channel 3 Address 124 Channel 4 Address 123 Channel Configuration If using less than four channels set the Number of Channels attribute 58 to the appropriate value Legal entries are 1 2 3 and 4 Each channel can also be configured as an embedded object within a single SDS address This requires an SDS master that understands how to communicate with embedded objects Enable Objects attribute 59 when set to a value of 1 each channel is config ured as an embedded object within a sin gle SDS address Note Changes to attributes 58 or 59 require power to be cycled to the module be fore changes take effect Tag Name Tag Name attribute 56 is a 32 character string that the user can enter to describe the functionality and or location of each channel of the BusBlock Analog Input Module Holjeron e 25599 SW 95 Ave Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com BusBlock Analog Input Module Holjeron w for the Smart Distributed System smart moves BBK 4052 3 Page 4 TECHNICAL DATA Operation The Bu
9. sBlock Analog Input module con Input Range Input Variable verts analog signals using the process defined below i Low Attribute 70 High Attribute 72 Limiting Enabled Attribute 61 Yes lt Low Limit Attribute 69 gt High Limit Attribute 71 Yes Input Variable Attribute 18 Change gt Deadband Attribute 65 Yes v Change of Value No Event uo e of oes The BusBlock Analog Input Module can be configured to accept either 0 5 VDC or 0 20 mA inputs through the Input Range attribute 68 A value of 0 is for voltage a value of 1 for current liamps and conversely the High Scale attribute 72 is the value to be sent when the incoming analog signal is at its highest value 10 VDC or 20 mA The incoming analog signal is then linearized to the low and high scale values The default value for low scale is 0 The default value for high scale is 32767 Limiting When Enable Limiting attribute 61 is set to 1 the input variable reported in a Change of Value Event will never be be low the Low Limit attribute 69 or above limits then a diagnostic bit is set and an event reported see Diagnostics The default value for low limit is 0 The default value for high limit is 32767 Attribute 18 functions as the input attrib ute for the BusBlock Analog Input
10. tance personally and through our literature it is up to the customer to determine the suitability of the product in the application All information contained herein in cluding illustrations specifications and dimensions is believed to be reliable as of the date of publication but is subject to change without notice BusBlock Analog Input Module for the Smart Distributed System 0903 TECHNICAL DATA di D E Specifications Part Number 4 Channel Analog Input Module BBK AIN104 Electrical SDS Voltage Range 11 25 VDC Current Consumption 60 mA analog loop power Data Rates 125 250 500 and 1000 kbps Inputs Type 0 20 mA 0 5 VDC selectable Number Four 4 Environmental Temperature Storage 30 to 70 C 22 to 158 F Operating 0 to 60 C 32 to 140 F Humidity 5 9596 RH non condensing Vibration 2G at 10 to 500 Hz Shock 10G Physical Dimensions 2 95 Hx 2 17 W x 4 33 D Weight 120z Color Bone Gray Case Material Polycarbonate Mounting DIN Rail or foot mount Terminations Cage Clamp Screw Terminal Indication Power Green Error Red SDS Green Holjeron e 25599 SW 95 Ave Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com Holieron BusBlock Analog Input Module for the Smart Distributed System TECHNICAL DATA smart moves