1. LED Sensitivity Input Voltage Range Flashes Setting AC Operation Recommended Use Green LOW 88 Vac to 142 Vac Use this setting with equipment that is less sensitive to fluctuations in voltage or waveform distortions Red MEDIUM 92 Vac to 139 Vac Factory default setting Use this setting under normal conditions Amber HIGH 96 Vac to 136 Vac Use this setting when connected equipment is sensitive to voltage and waveform fluctuations Troubleshooting Problem and Possible Cause Solution The Back UPS will not turn on The Back UPS has not been turned on Press the POWER ON button The Back UPS is not connected to AC power there is no AC power available at the wall outlet or the AC power is experiencing a brownout or over voltage condition Make sure the power cord is securely connected to the wall outlet and that there is AC power available at the wall outlet Where applicable check that the wall outlet is switched on The battery is not connected Connect the battery Refer to Connect the Battery on page 1 of this manual In the event that the Back UPS receives no AC power and the battery is connected a cold start can be initiated Press and hold the Power On button until the Back UPS emits two beeps tone The Back UPS is on the Replace Battery LED flashes and the unit emits a constant The battery is disconnected Refer to the Connect the Battery on page
2. The battery is near the end of useful life and should be replaced Leave the Back UPS connected to AC power for 16 hours while the battery charges to full capacity As a battery ages the runtime capability decreases Contact APC by Schneider Electric at the Web site www apc com to order replacement batteries The connection from the Back UPS to the internet is lost during a power outage The modem has lost power Connect the broadband modem into one of the Battery Backup Surge Protection outlets Replace Battery Deliver the used battery to a recycling facility Replace the used battery with an APC by Schneider Electric approved battery Replacement batteries can be ordered through the APC by Schneider Electric Web site www apc com Battery replacement part for Back UPS BGE70 is APCRBC153 vm Service If the unit requires service do not return it to the dealer Follow these steps 1 Review the Troubleshooting section of the manual to eliminate common problems 2 If the problem persists contact Schneider Electric IT SEIT Customer Support through the APC by Schneider Electric Web site www apc com a Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models b Call SEIT Customer Support and a technician will attempt to solve the problem over the phone If
3. securely to the battery terminal It is normal for small sparks to be seen when the battery cable is connected to the battery terminal bu380a Reinstall the battery compartment cover Be sure that the release tab locks into place Voltage Sensitivity Adjustment optional The Back UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment In situations where either the Back UPS or the connected equipment is too sensitive for the input voltage level it is necessary to adjust the transfer voltage 1 Connect the Back UPS to a wall outlet The Back UPS will be in Standby mode no indicators will be illuminated 2 Press and hold the ON OFF button for 10 seconds The OnLine LED will illuminate alternately green red to indicate that the Back UPS is in Program mode 3 The Power On Replace Battery LED will flash either green amber or red to indicate the current sensitivity level Refer to the table for an explanation of the transfer voltage sensitivity levels 4 To select LOW sensitivity press and hold the ON OFF button until the LED flashes green 5 To select MEDIUM sensitivity press and hold the ON OFF button until the LED flashes red 6 To select HIGH sensitivity press and hold the ON OFF button until the LED flashes amber 7 To exit Program mode wait five seconds and all LED indicators will extinguish Program mode is no longer active
4. 1 Connected equipment loses power A Back UPS overload condition has occurred Remove all nonessential equipment connected to the outlets One at a time reconnect equipment to the Back UPS The Back UPS battery is completely discharged Connect the Back UPS to AC power and allow the battery to recharge for eight hours Connected equipment does not accept the step approximated sine waveform from the Back UPS The output waveform is intended for computers and peripheral devices It is not intended for use with motor driven equipment The Back UPS may require service Contact Schneider Electric IT SEIT Technical Support for more in depth troubleshooting The Power On LED is illuminated and the Back UPS beeps 4 times every 30 seconds The Back UPS is operating on battery power The Back UPS is operating normally on battery power At this point the user should save all open files and shutdown the computer When AC power is restored the battery will recharge second The Power On LED flashes once every second while the Back UPS beeps once every The Back UPS battery has approximately two minutes of remaining runtime The Back UPS battery is near a total discharge state At this point the user should save all open files and shutdown the computer When AC power is restored the battery will recharge The Back UPS has an inadequate battery runtime The battery is not fully charged
5. APC by Schneider Electric User Manual Back UPS Connect BGE 70 70 CA 120 Vac Inventory Connect Equipment Safety and General Information Inspect the package contents upon receipt Notify the carrier and dealer if there is any damage Battery Backup Outlets Battery backup outlets provide protection to connected equipment when the Back UPS is turned on and connected to AC power Read the Safety Guide supplied with this unit before installing the UPS This unit is designed for low power devices less than 75 Watts When the UPS is on battery the unit will shut down automatically to protect itself once the load on the UPS is greater than 75 Watts This UPS is intended for indoor use only e Do not operate this UPS in direct sunlight in contact with fluids or where there is excessive dust or humidity Be sure the air vents on the UPS are not blocked Allow adequate space for proper ventilation e The battery typically lasts for three to five years Environmental factors impact battery life Elevated ambient temperatures poor quality AC power and frequent short duration discharges will shorten battery life e Connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords Battery backup outlets receive power from the Back UPS for a limited period of time when a power outage or brownout condition occurs Battery
6. backup outlets provide protection from power surges or spikes Connect a broadband modem and wireless router to the outlets Voice over IP VOIP phones if applicable should also be plugged into battery backup outlets To maximize runtime in the event of a power outage only connect networking equipment to battery backup outlets This UPS is designed to sustain low power devices for extended periods of time When the UPS is on battery the unit will shut down automatically if the load on the UPS exceeds 75Watts Low power devices include modems routers USB chargers 5W and 10W VOIP and cordless phones Turn On the Back UPS Specifications Press the POWER ON button located on the top of the Back UPS The Power On Input Voltage 120 Vac Nominal sa Sanaa are Ri esha parece a ree beep Mp be ey to Frequency 50 60 Hz 3 indicate that the Back is providing protection for connected equipment Brownout Transfers 92 Vac Typical The Back UPS battery charges fully during the first 16 hours while connected to AC power The Back UPS battery will charge while the Back UPS is switched on or off Over voltage Transfer 139 Vac Typical and is connected to AC power Do not expect full battery run capability during the Output UPS Capacity 125 VA 75 W initial charge time 3 battery backup outlets Total Amperage all outlets 1 04 A including UPS output Status Indi
7. cators Voltage On Battery 115 Vac 8 Frequency On Battery 50 60 Hz 1 Power Button Audible Audible Indicator Status LED Indicator On Terminat Transfer Time 6 ms Typical 10 ms maximum DUICAVOT t0 STAATES Protection AC Surge Protection Full time 90 Joules Power On The LED None N A and EMI RFI Filter Full time The Back UPS is illuminates green Filtering supplying AC power to AC Input Resettable circuit breaker connected equipment Battery Type Sealed maintenance free lead acid On Battery The LED Back UPS Beeping stops at the RBC153 Back UPS supplying illuminates green beeps for 2 _ end of the first two Average Life 3 5 years depending on the number of battery power to battery The LED flashes seconds seconds A constant discharge cycles and environmental backup outlets once at the end of when beep at the initial temperature every 2 seconds entering two seconds Physical Net Weight 5 51 Ib 2 5 kg battery indicates the Back y i o 2 mode UPS has entered the Dimensions 8 9 in x 4 1 in x 5 2 in battery mode Length x Width x Height 22 5 10 5 13 2 sc es ae 5 om Low Battery warning The LED The Back Beeping stops when Operating Temperature 32 F to 104 F 0 C to 40 C The Back UPS is illuminates green UPS emits AC power is Storage Temperature 5 F to 113 F 15 C to 45 C supplying battery power to and flashes in rapid restored or the Back Operating Relative Humidity 0 to 95 non condensing humid
8. f a valid credit card number The customer pays for shipping the unit to SEIT SEIT pays ground freight transportation costs to ship the replacement unit to the customer APC by Schneider Electric IT Customer Support Worldwide For country specific customer support go to the APC by Schneider Electric Web site www apc com EMC Compliance This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This UPS is certified to comply with California Battery Charger System regulations For more information go to www apc com site recycle index cfm energy efficiency cec battery charger EN 990 5285 2013 APC by Schneider Electric APC the APC logo and Back UPS are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of their respective owners 12 2013
9. ity the battery backup outlets rapid succession beeping UPS is turned off and the battery is near a every Operating Elevation 0 to 10 000 ft 0 to 3000 m total discharge state 1 2 second Replace Battery The LED Constant Back UPS is turned Connect the B attery The battery is alternately tone off disconnected illuminates green C nstant The Back UPS is shipped with one battery cable disconnected The battery needs to be red onstan charged or replaced one Overload Shutdown None Constant Back UPS is turned While on battery power an tone off overload condition has occurred in one or more of the battery backup outlets while the Back UPS is operating on battery power Sleep Mode None The Back The beeping stops While on battery power UPS beeps when the battery is completely once every e AC power is 1 Remove the Stop Connect the 2 Press the battery compartment cover discharged The four seconds restored Battery label that covers the outlets release tabs located on the rear side of the Back UPS will awaken If AC power is not unit Slide the battery cover off once AC power is restored within 32 restored seconds e The Back UPS is turned off Wall Mount Installation e Horizontal installation use 2 screws 3 15 16 100 mm apart e Allow 5 16 8 mm of the screw to protrude from the wall 3 in i 100 mm Wall mounting Template Connect the battery cable
10. this is not possible the technician will issue a Returned Material Authorization Number RMA c Ifthe unit is under warranty the repairs are free d Service procedures and returns may vary internationally Refer to the APC by Schneider Electric Web site for country specific instructions 3 Pack the unit in the original packaging whenever possible to avoid damage in transit Never use foam beads for packaging Damage sustained in transit is not covered under warranty 4 Always DISCONNECT THE UPS BATTERIES before shipping The United States Department of Transportation DOT and the International Air Transport Association LATA regulations require that UPS batteries be disconnected before shipping The internal batteries may remain in the UPS 5 Write the RMA provided by Customer Support on the outside of the package 6 Return the unit by insured pre paid carrier to the address provided by Customer Support Warranty The standard warranty is three 3 years from the date of purchase Schneider Electric IT SEIT standard procedure is to replace the original unit with a factory reconditioned unit Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT Technical Support representative SEIT will ship the replacement unit once the defective unit has been received by the repair department or cross ship upon the receipt o