Home

UMI - User Manual Supplement

image

Contents

1. UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 8 HARDWARE WARRANTY The warranty period for hardware shall be ninety 90 days from the date of shipment from Datatek Replacements and repairs are guaranteed for the longer of the remaining original warranty period or 30 days 9 END USER LICENSE AGREEMENT FOR SOFTWARE This License Agreement License is a legal contract between you and the manufacturer Manufacturer of the system HARDWARE with which you acquired software product s identified above SOFTWARE The SOFTWARE may include printed materials that accompany the SOFTWARE Any software provided along with the SOFTWARE that is associated with a separate end user license agreement is licensed to you under the terms of that license agreement By installing copying downloading accessing or otherwise using the SOFTWARE you agree to be bound by the terms of this LICENSE If you do not agree to the terms of this LICENSE Manufacturer is unwilling to license the SOFTWARE to you In such event you may not use or copy the SOFTWARE and you should promptly contact Manufacturer for instructions on return of the unused product s for a refund 9 1 Software License You may only install and use one copy of the SOFTWARE on the HARDWARE unless otherwise licensed by Manufacturer The SOFTWARE may not be installed accessed displayed run shared or used concurrently on or from diff
2. vport vport dest Enter chg del umi vport module address vport number destination ip address vport vport dport Enter chg del umi vport module address vport number destination tcp port vport vport hport Enter chg del umi vport module address vport number hunt group port vport vport cug Enter chg del umi vport module address vport number cug list vport vport prot Enter chg del umi vport module address vport number protocol vport vport crfix Enter chg del umi vport module address vport number null after carriage return vport vport crf Enter chg del umi vport module address vport number If after carriage return vport vport data Enter chg del umi vport module address vport number bits per character 5 12 9 2004 AN Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Command Parameter Comparison Table Continued UMI Module Command Parameters BNS Datakit Command Parameters Comments vport vport session Enter chg del umi vport module address vport number session hold attention character attention action vport vport crypt Enter chg del umi vport module address vport number peer to peer encryption 5 12 9 2004 Datatek Applications Inc
3. Manufacturer is Datatek Applications Inc 721 Rte 202 206 Bridgewater New Jersey 08807 If you acquired the SOFTWARE in the United States of America this Software License are governed by the laws of the State of New Jersey excluding its choice of laws provisions If you acquired the SOFTWARE outside the United States of America local law may apply This LICENSE constitutes the entire understanding and agreement between you and the Manufacturer in relation to the SOFTWARE and supercedes any and all prior or other communications statements documents agreements or other information between the parties with respect to the subject matter hereof 10 LIMITATION OF LIABILITY To the maximum extent permitted by applicable law in no event shall Manufacturer or its suppliers be liable for any damages whatsoever including without limitation special incidental consequential or indirect damages for personal injury loss of business profits business interruption loss of business information or any other pecuniary loss arising out of the use of or inability to use this product even if Manufacturer has been advised of the possibility of such damages In any case Manufacturer s and its suppliers entire liability under any provision of this License shall be limited to the amount actually paid by you for the SOFTWARE and or the HARDWARE Because some states jurisdictions do not allow the exclusion or limitation of liability for consequential or
4. DOMAIN NAME 3 mnemonic none none The command then loops back to the MODULE ADDRESS prompt Enter and Change continued If the COMPONENT is vport The following prompts correspond to the parameters in the vport command on the UMI console MODULE ADDRESS VPORT NUMBER 1 504 1 504 COMMENT up to 60 chars double quoted PROTOCOL async sync raw SERVICE TYPE bns to ip ip to bns ip_to_bns GROUP up to 8 chars PROTOCOL is sync and SERVICE TYPE is ip to bns PREDEFINED DESTINATION PROTOCOL is async or raw and SERVICE TYPE is ip to bns PREDEFINED DESTINATION none SESSION HOLD on off off If SESSION HOLD is on ATTENTION CHARACTER none 1brk del a character 1brk ATTENTION ACTION command mode disconnect command_mode If PROTOCOL is async or raw and SERVICE TYPE is ip_to_bns NODE ECHOES USER INPUT yes no yes If PROTOCOL is async or raw NULL AFTER CARRIAGE RETURN transparent no_null transparent LF AFTER CARRIAGE RETURN transparent no 1f transparent BITS PER CHARACTER 8bits 7bits 8bits Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Enter and Change Component vport continued If SERVICE TYPE is ip_to_bns HUNT GROUP POR
5. SNMP PORT DNS1 IP ADDR DNS2 IP ADDR DNS3 IP ADDR DNS NAME1 DNS NAME2 DNS NAME3 SNMP Community SNMP MIB II sysContact SNMP MIB II sysName SNMP MIB II sysLocation COMMENT CUG ID gt 1 IP ADDRESS gt 122 122 2 2 IP SUBMASK gt 255 255 255 0 CUG ID gt 3 IP ADDRESS gt 192 168 22 22 IP SUBMASK gt 255 255 0 0 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Verify continued If COMPONENT is pdd MODULE ADDRESS DESTINATION PDD ID 1 16 The format of a sample output report is 02 04 12 12 58 10 NODE tweety verify umi pdd 17 1 16 MODULE ADDRESS 17 MODULE TYPE umi NCHLS 512 SERVICE STATE out manual DOWNLOAD SERVER controller VERSION standard GATEWAY ADDRESS LOCAL IP ADDR 0 0 LOCAL SUBMASK SNMP IP ADDR oO ic SNMP PORT DNS1 IP ADDR DNS2 IP ADDR DNS3 IP ADDR DNS NAME1 DNS NAME2 DNS NAME3 SNMP Community SNMP MIB II sysContact SNMP MIB II sysName SNMP MIB II sysLocation COMMENT Destination PDDs PDD ID gt 1 PDD gt nj dtk tweety PDD ID gt 2 PDD gt homeaddress Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 4 Remove and Restore CCO gt remove or restore OBJECT umi umi COMPONENT module vport If COMPONENT is
6. encapsulation is different 5 1 Retrieve and Convert If an existing definition of the UMI exists in the node as a SAM504 and in the UMI itself there are two utilities to assist the administrator to convert these definitions into UMP defined on the controller Retrieve and Convert CCO gt retrieve umi lt mod no gt Where the module address is the number of the in service SAM504 module The command requests IP configuration information from the UMI The replies from the UMI will be used to build a configuration file for the UMI The module must be in service for the control computer to communicate with it After the retrieve command is run the module must be converted from a SAM504 to a UMI Remove the module with CCO gt remove sam module lt mod_no gt With the SAM504 out of service run the following command which will convert the SAM504 to a UMI and add any missing configuration CCO gt convert module lt mod_no gt umi Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 2 Enter and Change The prompts below are the same for both the enter and the change commands For the enter command the default for a parameter is shown in parenthesis for that parameter when there is a default For the change command the default value is the currently configured value for that parameter CCO gt enter or change OBJECT
7. entered either in prompted mode single line mode or a combination just like for other BNS commands The appendix shows the correspondence between the commands and parameters that were entered at a UMI module console and those that are now entered via a BNS 2000 VCS console on a node or a StarKeeper console via the setnode command For change verify and delete commands the values for some parameters can be ranges If a range specifies all possible values for a parameter the controller interprets the range as meaning all configured values lf something less than the entire range is specified then all entities in the range have to have been previously configured Otherwise the command is rejected For example in verify umi vport the user can specify the range 1 504 for the vport number which is interpreted as all If only 300 of the possible 504 vports have been configured the command would execute properly and all 300 vports displayed However if the user had specified the range 1 503 in the command and only 300 ports had been configured the command would be rejected It s important to note that although a single UMI supports call setup in both directions simultaneously each grouping of virtual ports must be configured for one direction only i e there are no two way virtual ports In addition virtual ports intended to be used for synchronous and asynchronous call connections must reside in different groups since their protocol
8. the module Datakit is a registered trademark of Lucent Technologies Inc licensed to Datatek Applications Inc a company independent of Lucent Technologies Inc 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 3 In order to take advantage of all the features and maintenance fixes for the UMI one of the following releases must be installed in the node e BNS 2000 VCS a k a Datakit II VCS Release 6 0 Build 95 e BNS 2000 Release 4 0 Build 92 e BNS 2000 Release 5 0 Build 88 Appendix A in section 6 provides a cross referenced list of UMI features and in what BNS Datakit release a feature was supported on a node 4 In order for StarKeeper II NMS to properly recognize and process UMI module information a free patch for Release 10 0 available from Datatek Applications Inc must be installed 3 FEATURE SUMMARY For this feature the object umi and its associated new components have been added to several controller commands The affected commands are 1 Enter Change Delete Verify UMI with the components Module Vport PDD Host and CUG 2 Remove Restore UMI with components Module and Vport 3 Retrieve UMI and Convert UMI For other commands sam is used as the argument even though the actual entity is a UMI module These commands are 1 Display Measurements 2 Display Status 3 Verify Comment The
9. umi umi COMPONENT module vport cug host pdd If COMPONENT is module The parameters correspond to the local gateway dns and snmp commands on the UMI console MODULE ADDRESS COMMENT up to 60 chars double quoted DOWNLOAD SERVER controller SOFTWARE VERSION standard GATEWAY ADDRESS decimal dot notation none LOCAL IP ADDRESS decimal dot notation none LOCAL IP SUBMASK decimal dot notation none SNMP IP ADDRESS decimal dot notation none none SNMP IP PORT 1 65535 none none SNMP IP CUG LIST 1 32 0 for none 0 INFO The non volatile initial values are stored on the DTK41 I O module for the following mib2 config If no DTK41 exists the command will still operate but the values remain volatile SNMP Community mnemonic none none SNMP MIB II sysContact mnemonic none none SNMP MIB II sysName mnemonic none none SNMP MIB II sysLocation mnemonic none none DNS IP ADDRESS l1 decimal dot notation none none DNS IP ADDRESS 2 decimal dot notation none none DNS IP ADDRESS 3 decimal dot notation none none DOMAIN NAME 1 mnemonic none none 5 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Enter and Change continued DOMAIN NAME 2 mnemonic none none
10. Dataick UNIVERSAL MEDIATION INTERFACE UMI MODULE USER S MANUAL SUPPLEMENT FOR BNS DATAKIT II VCS NODES Issue 1 3 Corresponds to UMI Build 23 or higher aP OIP ee S BNS BNS BNS NS BNS BNS BNS BN IP IP IP IP IP 721 Route 202 206 Bridgewater NJ 08807 fax 908 218 1736 phone 908 218 0500 email sales datatekcorp com http www datatekcorp com APPLICATIONS INC UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES TABLE of CONTENTS Introduction Prerequisites and Caveats Feature Summary Database Issues Commands 5 1 5 2 5 3 5 4 5 5 Delete 5 6 Display Commands 5 6 1 Display Measurements 5 6 2 Display Status 5 6 3 Verify Comment Appendix A Feature List and Node Build Number Correspondence Appendix B Command Parameter Comparison Table Hardware Warranty End User License Agreement for Software 9 1 Software License 9 2 Intellectual Property Rights 9 3 Software Support 9 4 Export Restrictions 9 5 Limited Warranty 9 6 No Other Warranties 9 7 Special Provisions 10 Limitation of Liability 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 1 INTRODUCTION Connectivity between an IP network and a BNS refers to both BNS 2000 and BNS 2000 VCS aka Datakit II VCS network is accomplished using the Universal Mediation Interface Module UMI A
11. ER prompt Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Enter and Change continued If COMPONENT is host The following prompts correspond to the parameters in the host command on the UMI console MODULE ADDRESS HOST ID 1 32 HOST NAME HOST IP ADDRESS decimal dot notation none HOST TCP PORT 1 65535 The command then loops back to the HOST ID prompt If COMPONENT is pdd The following prompts correspond to the parameters in the pdd command on the UMI console This command allows the specification of mnemonic addresses instead of numeric IP addresses Note This functionality can only be used if the UMI has a DTK41 IO board installed It the board is not present on the UMI this configuration will be ignored by the UMI MODULE ADDRESS DESTINATION PDD ID 1 16 DESTINATION PDD ADDRESS up to 63 characters not double quoted none The word none is reserved Its deletes a PDD address It cannot be used as a valid PDD address name The command then loops back to the DESTINATION PDD ID prompt Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 3 Verify CCO gt verify OBJECT umi COMPONENT module vport host cug pdd If COMPONE
12. NT is module MODULE ADDRESS all1 The format of a sample output report is 04 04 12 12 59 16 NODE tweety verify umi module 17 MODULE ADDRESS 17 MODULE TYPE umi NCHLS 512 SERVICE STATE out manual DOWNLOAD SERVER controller VERSION standard GATEWAY ADDRESS LOCAL IP ADDR 0 0 LOCAL SUBMASK 0 0 0 0 SNMP IP ADDR 0 0 SNMP PORT 0 DNS1 IP ADDR DNS2 IP ADDR DNS3 IP ADDR DNS NAME1 DNS NAME2 DNS NAME3 SNMP Community SNMP MIB II sysContact SNMP MIB II sysName SNMP MIB II sysLocation Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Verify continued If the COMPONENT is vport MODULE ADDRESS VPORT NUMBER 1 504 1 504 The format of a sample output report is 04 12 07 14 02 06 NODE brain M verify umi vport 71 1 504 MODULE ADDRESS 71 MODULE TYPE umi SERVICE STATE in DOWNLOAD SERVER controller VERSION standard GATEWAY ADDRESS 192 168 8 1 LOCAL IP ADDR 192 168 8 22 LOCAL SUBMASK 255 255 255 0 SNMP IP ADDR 192 168 8 11 SNMP PORT 162 SNMP CUG LIST 0 DNS1 IP ADDR 192 168 1 15 DNS2 IP ADDR 0 0 0 0 DNS3 IP ADDR 0 0 0 0 DNS NAME1 datatekcorp com DNS NAME2 datatekcorp com DNS NAME3 datatekcorp com SNMP Community none SNMP MIB II sysContact none SNMP MIB II sysName none SNMP MIB II sysLocation none COMMENT test of comments Virtual Port Number 1
13. PENDIX A FEATURE LIST AND NODE BUILD NUMBER CORRESPONDENCE Feature Minimum Build Required Datakit R6 SNMP CUGs 20 88 92 82 Destination PDD 20 88 92 82 Multiple DNS IP Addresses SNMP Community 22 90 92 84 SNMP SysName 22 90 92 84 SNMP SysContact 22 90 92 84 SNMP SysLocation 22 90 92 84 UMI files included by Backup Host UMI files included by Retrieve Host UMI BNS R4 BNS R5 21 88 92 82 19 91 92 85 19 91 92 85 Remove UMI files via dvdelete on node Double Dial 23 92 92 86 verify grp umi 19 92 92 86 Host ID Range of 1 32 19 91 92 85 19 93 92 87 Vports shown on i 19 93 92 87 Display connections verify comment umi 19 95 92 88 dstat umi 19 95 92 88 dmeas umi 19 95 92 88 Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 7 APPENDIX B COMMAND PARAMETER COMPARISON TABLE UMI Module Command Parameters BNS Datakit Command Parameters Comments admpass No comparable BNS UMI module command Enter node command administers password for the node console banner No comparable BNS UMI module command chgpass No comparable BNS UMI module command Change node command administers password for the node console clear No comparable BNS module command console No com
14. RE and all of its component parts 9 2 Intellectual Property Rights The SOFTWARE is licensed not sold to you The SOFTWARE is protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties You may not copy the printed materials accompanying the SOFTWARE All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE is the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties This LICENSE grants you no rights to use such content All rights not expressly granted under this LICENSE are reserved Manufacturer and its licensors if any 12 09 04 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 9 3 Software Support SOFTWARE support is not provided by Manufacturer or its affiliates or subsidiaries separate from the HARDWARE For SOFTWARE support please contact your supplier of the HARDWARE Should you have any questions concerning this LICENSE or if you desire to contact Manufacturer for any other reason please refer to the address provided in the documentation for the HARDWARE 9 4 Export Restrictions You agree that you will not export or re export the SOFTWARE to any country person or entity subject to U S export restrictions You specifically agree not to export or
15. T 1 65535 23 CUG LIST 1 32 0 for none 0 If SERVICE TYPE is bns_to_ip DESTINATION IP ADDRESS decimal dot notation none DESTINATION TCP PORT 1 65535 none DESTINATION PDD ID 1 16 0 for none 0 TO PEER ENCRYPTION transparent encrypt transparent If module SERVICE STATE is out INITIAL SERVICE STATE in out out The command then loops back to the VPORT NUMBER prompt Vports are entered as single ports or ranges of ports The specific values of parameters chosen for the vports in a range generate a single IP configuration Changes to that configuration should also be input as a range If a parameter value for a single vport within a range is changed the range will be split into multiple ranges that cannot be rejoined Corresponding and multiple IP configurations will be generated For example if vport 1 200 are entered there is one IP configuration for all of these ports If vport 100 is changed there will now be three ranges and three IP configurations vports 1 99 vport 100 and vports 101 200 This is obvious in the verify report output Enter and Change continued If COMPONENT is cug The following prompts correspond to the parameters in the cug command on the UMI console MODULE ADDRESS CUG NUMBER 1 32 CUG IP ADDRESS decimal dot notation none CUG SUBMASK decimal dot notation none The command then loops back to the CUG NUMB
16. b repair or replacement of the SOFTWARE that does not meet this Limited Warranty and which is returned to Manufacturer with a copy of your receipt This Limited Warranty is void if failure of the SOFTWARE has resulted from accident abuse or misapplication Any replacement SOFTWARE will be warranted for the remainder of the original warranty period or thirty 30 days whichever is longer 9 6 No Other Warranties TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW MANUFACTURER AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT WITH REGARD TO THE SOFTWARE AND THE ACCOMPANYING WRITTEN MATERIALS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHERS WHICH VARY FROM STATE JURISDICTION TO STATE JURISDICTION 9 7 Special Provisions The SOFTWARE and documentation are provided with RESTRICTED RIGHTS Use duplication or disclosure by the United States Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and HARDWARE Software clause at DFARS 252 227 7013 or subparagraphs c 1 and 2 of the Commercial HARDWARE Software 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Restricted Rights at 48 CFR 52 227 19 as applicable
17. ents similar to those displayed currently for the SAM504 CCO gt dmeas umi COMPONENT module vport mod MODULE ADDRESS INTERVAL current previous current CCO gt dmeas umi COMPONENT module vport vport MODULE ADDRESS PORT NUMBER 1 504 1 504 INTERVAL current previous current 5 6 2 Display Status The validation routines for the dstat umi and dstat module command processes will recognize the UMI community type The reports will display similar information as that provided for the SAM504 but using the values used for UMI s Cco gt dstat umi COMPONENT module vport module mod MODULE ADDRESS DETAIL low high low CCO gt dstat umi COMPONENT module vport module vport MODULE ADDRESS VIRTUAL PORT NUMBER 1 504 5 Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 6 3 Verify Comment Select umi as the object for Verify Comment beginning with Datakit R6 Build 95 BNS 2000 R4 Build 92 and BNS 2000 R5 Build 88 For earlier builds sam was selected as the object CCO gt vfy comment MODULE TYPE sam umi all umi SEARCH CRITERION double quoted string or pattern all all Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 6 AP
18. erent computers including a workstation terminal or other digital electronic device Devices Notwithstanding the foregoing and except as otherwise provided below any number of Devices may access or otherwise utilize the services of the SOFTWARE You may not reverse engineer decompile or disassemble the SOFTWARE except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation The SOFTWARE is licensed as a single product Its component parts may not be separated for use on more than one HARDWARE The SOFTWARE is licensed with the HARDWARE as a single integrated product The SOFTWARE may only be used with the HARDWARE as set forth in this LICENSE You may not rent lease or lend the SOFTWARE in any manner You may permanently transfer all of your rights under this LICENSE only as part of a permanent sale or transfer of the HARDWARE provided you retain no copies you transfer all of the SOFTWARE including all component parts the media and printed materials any upgrades this LICENSE and if applicable the Certificate s of Authenticity and the recipient agrees to the terms of this LICENSE If the SOFTWARE is an upgrade any transfer must also include all prior versions of the SOFTWARE Without prejudice to any other rights Manufacturer may terminate this LICENSE if you fail to comply with the terms and conditions of this LICENSE In such event you must destroy all copies of the SOFTWA
19. he pdd address table To delete a pdd address do a chg umi and select pdd Set the address to the value none CCO gt change or chg OBJECT umi umi COMPONENT module vport cug host pdd If COMPONENT is pdd MODULE ADDRESS DESTINATION PDD ID 1 16 select index of pdd to be deleted DESTINATION PDD ADDRESS none Note that if a destination pdd address is deleted from the pdd table by using the above sequence the destination pdd id is no longer defined A vport that previously has had its destination pdd id set to this index value will still have the value of its destination pdd id set to this index even though the pdd has no address value The delete command is also not used to delete the value of a destination pdd id from a vport definition To delete the value of a destination pdd id from a vport do a chg umi and select vport Set the destination pdd id to a numeric zero 0 This affects only this vport 5 Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 6 Display Commands Previously the two commands display measurements dmeas and display status dstat for the UMI module worked in the following way When either command is input the OBJECT sam was used instead of umi when the module was actually a UMI and not a SAM trunk module These commands treated the UMI a
20. incidental damages the above limitation may not apply to you Copyright 2002 2005 Datatek Applications Inc Copyright 2002 2005 TeleComp Research and Development Inc All Rights Reserved Printed in USA 5 Datatek Applications Inc 12 9 2004
21. io enable all No comparable BNS UMI module command hpio disable all No comparable BNS UMI module command hpio enable fiber 10 100 phy range No comparable BNS UMI module command hpio disable fiber 10 100 phy range No comparable BNS UMI module command Install No comparable BNS UMI module command New UMI module software must be installed via UMI hardware telnet console not available as a node controller option label No comparable BNS UMI module command local ipaddr submask Enter chg umi module module address local ip address local ip submask IP address must be entered via UMI serial console login logout No comparable BNS UMI module command pdd Enter chg umi pdd module address destination pdd id destination pdd address ping No comparable BNS node command Can ping from StarKeeper if StarKeeper host is connected to IP network reboot Remove restore umi module module address 12 9 2004 5 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Command Parameter Comparison Table Continued UMI Module Command Parameters BNS Datakit Command Parameters Comments remove Remove umi module module address restore Restore umi module module address snmp ipaddr port Enter chg umi module module addres
22. module MODULE ADDRESS If the COMPONENT is vport MODULE ADDRESS VPORT NUMBER 1 504 1 504 The restore umi mod command will restore the UMI module and any ready for service RFS vports It will download the IP configuration data entered for the module except for the UMI s IP address ready for service ports hosts and cugs If the module address is already in service the restore umi vport command will restore the vport or ports and send the vport configuration information to the module If the module is out of service the vport or ports will be marked RFS The remove umi mod command will take the UMI module out of service and mark any in service vports as RFS 5 5 Delete When deleting a UMI module all the vports must be deleted first CUGS pdds and hosts for that UMI do not They will be automatically deleted when the module is deleted CcO gt delete OBJECT umi umi COMPONENT module vport cug host If COMPONENT is module MODULE ADDRESS If the COMPONENT is vport MODULE ADDRESS VPORT NUMBER 1 504 1 504 Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Delete continued If COMPONENT is cug MODULE ADDRESS CUG NUMBER 1 32 If COMPONENT is host MODULE ADDRESS HOST ID 1 32 The delete command is not used to delete a pdd from t
23. n gt Transparent COMMENT Note that the content of the verify umi vport report will depend on the type of PROTOCOL and SERVICE TYPE for a range of ports The output will differ for async versus sync or raw and bns_to_ip versus ip_to_bns Verify continued If COMPONENT is host MODULE ADDRESS HOST ID 1 32 The format of a sample output report is 02 04 12 12 58 10 NODE tweety verify umi host 17 MODULE ADDRESS 17 MODULE TYPE umi NCHLS 512 SERVICE STATE out manual DOWNLOAD SERVER controller VERSION standard GATEWAY ADDRESS LOCAL IP ADDR 0 0 LOCAL SUBMASK SNMP IP ADDR 0 0 SNMP PORT DNS1 IP ADDR DNS2 IP ADDR DNS3 IP ADDR DNS NAME1 DNS NAME2 DNS NAME3 SNMP Community SNMP MIB II sysContact SNMP MIB II sysName SNMP MIB II sysLocation Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Verify Component host continued COMMENT HOST ID gt 6 HOST NAME gt pamela IP ADDRESS gt 1 2 3 4 TCP PORT gt 5000 Verify continued If COMPONENT is cug MODULE ADDRESS CUG NUMBER 1 32 1 32 The format of a sample output report is M verify umi cug 17 MODULE ADDRESS 17 MODULE TYPE umi NCHLS 512 SERVICE STATE out manual DOWNLOAD SERVER controller VERSION standard GATEWAY ADDRESS LOCAL IP ADDR 050 LOCAL SUBMASK SNMP IP ADDR s070
24. nloaded to the UMI module when it is restored to service Beginning with build 23 the UMI s internal IP address is no longer downloaded from the node due to security reasons The major benefits are that all IP configuration information for the module and all the virtual ports can be entered changed verified saved and backed up on the BNS controller just like for any other BNS module and once only The exception is the IP address which must be input on both the node and UMI separately This document provides all the new commands and changes made in the node s controller A new maintenance release of the node controller software must be obtained and installed on a node in order to use this feature Presently this feature is available for nodes running BNS 2000 VCS Datakit II VCS Release 6 0 only and for BNS 2000 Releases 4 0 and 5 0 Explanation of each of the comparable parameters in the commands is shown in the UM UMI 2 PREREQUISITES AND CAVEATS There are a few prerequisites and caveats 1 It is assumed that the reader is already familiar with the terminology methods and conventions in the BNS Datakit documentation that are used to configure modules in a node and that a copy of the UM UMI is available for reference The format of the commands described below is the same as used in existing BNS documentation The UMI module must have build 19 or above installed in it This document assumes that build 23 or above is installed on
25. ode via the node console and on the UMI itself via the UMI console If the two are different the node produces a MAJOR alarm when downloading the UMI module The new UMI configuration information is added to the controller disk files in etc New files are generated and named umimod lt mod mo gt These files are included in all of the database management processes including backup and sync Therefore installation of the BNS 2000 VCS Release 6 0 Build 87 or higher BNS 2000 Release 4 0 Build 92 or higher or BNS 2000 Release 5 0 Build 82 or higher does not require a database upgrade or conversion for this feature After a UMI module has been configured on the node using the new controller capability if a user enters a change via the UMI s console for a parameter that can be configured on a node that change is not saved in the BNS database Therefore when that module is re downloaded from the controller as the result of a restore command all changes configurable on a node but entered via a UMI console will be lost All changes should be installed using the BNS edit commands on the node except for the UMI s IP address which must be entered on both the node and in the module and the banner which must be configured via the UMI console Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 COMMANDS The commands presented below can be
26. parable BNS module command Can administer BNS node console security using enter and change node commands cug cug number ipaddr submask Enter chg del umi cug module address cug number cug ip address cug submask dconn Display connections type Information in BNS report not same as UMI module dconn report disc vport vport Remove restore umi vport module address vport number disc console No comparable BNS module command dm mod Dmeas umi module module interval Actual module in BNS node is UMI dm vport vport Dmeas umi port module address vport range interval Actual module in BNS node is UMI dns ipaddrX nameX Enter chg umi module module address dns ip address X domain name X gateway ipaddr Enter chg umi module module address 12 9 2004 gateway address Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Command Parameter Comparison Table Continued UMI Module Command Parameters BNS Datakit Command Parameters Comments help Help or dkhelp from StarKeeper II NMS host host name ipaddr port Enter chg umi host module address host id host ip address host tcp port host host del Delete umi host module host id hpio reset No comparable BNS UMI module command hp
27. re export the SOFTWARE i to any country to which the U S has embargoed or restricted the export of goods or services which as of March 1998 include but are not necessarily limited to Cuba Iran Iraq Libya North Korea Sudan and Syria or to any national of any such country wherever located who intends to transmit or transport the products back to such country ii to any person or entity who you know or have reason to know will utilize the SOFTWARE or portion thereof in the design development or production of nuclear chemical or biological weapons or iii to any person or entity who has been prohibited from participating in U S export transactions by any federal agency of the U S government 9 5 Limited Warranty Manufacturer warrants that a the SOFTWARE will perform substantially in accordance with the accompanying written materials for a period of ninety 90 days from the date of shipment Software support is limited to the hours of 9 AM to 5 PM ET Monday through Friday excluding Datatek observed holidays Other coverage and extended warranty may be purchased at additional cost Any implied warranties on the SOFTWARE are limited to ninety 90 days Some states jurisdictions do not allow limitations on duration of an implied warranty so the above limitation may not apply to you Manufacturer s and its suppliers entire liability and your exclusive remedy shall be at Manufacturer s option either a return of the price paid or
28. s snmp ip address snmp udp port snmp cug Enter chg umi module module address snmp cug list snmp comm Enter chg umi module module address snmp community snmp syscontact Enter chg umi module module address snmp MIB II sysContact snmp sysname Enter chg umi module module address snmp MIB II sysName snmp sysloc Enter chg umi module module address snmp MIB II sysLocation timeout No comparable BNS UMI module or node Node console has non settable timeout for command command input uprompt No comparable BNS UMI module command version No comparable BNS UMI module command vfy mod Verify umi module module address vfy vport Verify umi vport module address vport number vfy cug Verify umi cug module address cug number 5 Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Command Parameter Comparison Table Continued UMI Module Command Parameters BNS Datakit Command Parameters Comments vfy host Verify umi host module address host id vport vport cnt incr Enter chg del umi vport module address vport number vport vport type Enter chg del umi vport module address vport number service type vport vport pdd Enter chg umi vport module address vport number destination pdd id
29. s a SAM504 in the command syntax and referred to SAM board and port Therefore a translation had to be done between the UMI vport number and the comparable SAM504 board and port The following table provides that translation BNS Controller SAM504 Board Port gt UMI Virtual Port mapping SAM504 Board Port Numbers UMI Virtual Port Numbers Board 1 Ports 1 32 Board 2 Ports 1 32 Board 3 Ports 1 32 Board 4 Ports 1 32 Board 5 Ports 1 32 Board 6 Ports 1 32 Board 7 Ports 1 32 Board 8 Ports 1 32 Board 9 Ports 1 32 Board 10 Ports 1 32 Board 11 Ports 1 32 Board 12 Ports 1 32 Board 13 Ports 1 32 Board 14 Ports 1 32 Board 15 Ports 1 32 Board 16 Ports 1 24 Ports 1 32 Ports 33 64 Ports 65 96 Ports 97 128 Ports 129 160 Ports 161 192 Ports 193 224 Ports 225 256 Ports 257 288 Ports 289 320 Ports 321 352 Ports 353 384 Ports 385 416 Ports 417 448 Ports 449 480 Ports 481 504 Now starting with Datakit R6 Build 95 BNS 2000 R4 Build 92 and BNS 2000 Build 88 both commands are invoked with umi as the OBJECT The resulting reports no longer rely on board and port but now are driven by module and vport numbers 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 5 6 1 Display Measurements The validation routines will recognize the UMI community type The dmeas umi command process will display measurem
30. s a state of the art solid state module that resides in a BNS node the UMI is both a replacement and enhancement of the LCS60 product The UMI allows both synchronous and asynchronous endpoints connected to a BNS network to access endpoints on an IP network Similarly endpoints on an IP network can access both synchronous and asynchronous endpoints on a BNS network The UMI can be located anywhere in the BNS network thus simplifying configuration administration and maintenance without affecting operation or connectivity This document is a supplement to the Universal Mediation Interface User Manual UM UMl and to the standard BNS documents Data Networking Products Synchronous Asynchronous Multiplexor Reference and Data Networking Products Commands Reference This supplement documents the new feature for a BNS Datakit controller that allows a UMI module to be configured as standard BNS module namely a UMI in the node Prior to this feature the UMI was configured on the BNS controller as a SAM504 mapping 504 BNS ports to 504 virtual ports residing in the IP network All IP configuration data was entered directly on the UMI console Hence every virtual port had to be configured twice once on the node and once on the UMI module itself With this feature the Base Configuration of the UMI and the configuration of all the virtual ports vports including their IP information is performed on the BNS node only and dow
31. syntax and details are described in later sections A third set of commands does not use sam or umi as an argument but are applicable Examples of these are 1 Verify Oosmods this command identifies UMI modules in the output 2 Display Circuits 3 Others There are several UMI commands that are not available on the node and hence must be executed on the UMI module console Examples are Banner HPIO Chgpass Admpass Version StarKeeper is a registered trademark of Lucent Technologies Inc licensed to Datatek Applications Inc a company independent of Lucent Technologies Inc 12 9 2004 sieve Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES 4 DATABASE ISSUES If a UMI has been previously configured on the node as a SAM504 and in the UMI module itself the information does not all have to re entered when using this feature The Datakit node retrieve and convert commands can be used However if there is an inconsistency between the definition on the node of a SAM port and the information in the UMI module the converted configuration will be consistent with the information originally in the node definition except for the UMI s IP address The IP address configured via the UMI console is not overridden by the downloaded one from the node due to security reasons If the IP address is changed it must be entered in both the n
32. to 1 Service State gt in Service Type gt bns_to_ip 12 9 2004 Datatek Applications Inc UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Verify Component vport continued Group gt umircv Protocol gt async Destination IP Address gt 0 0 0 0 TCP Port 23 Null after CR gt Transparent LF after CR gt Transparent Bits Per Character gt 8bit Peer to Peer Encryption gt Transparent COMMENT test of retr umi 04 12 07 14 02 06 NODE brain M verify umi vport 71 1 504 Virtual Port Number 2 to 32 Service State gt in Service Type gt ip_to_bns Group gt umiorig Protocol gt async PDD gt none Hunt Group Port gt 23 CUG list gt 0 Node Echo User Input gt yes Session Hold gt off Null after CR gt Transparent LF after CR gt Transparent Bits Per Character gt 8bit Peer to Peer Encryption gt Transparent COMMENT test of retr umi Virtual Port Number 200 to 200 Service State gt in Service Type gt bns_to_ip Group gt umircv Protocol gt async 5 Datatek Applications Inc 12 9 2004 UNIVERSAL MEDIATION INTERFACE UMI USER MANUAL SUPPLEMENT for BNS DATAKIT II VCS NODES Verify Component vport continued Null after CR gt Transparent LF after CR gt Transparent Bits Per Character gt 8bit Peer to Peer Encryptio