Home

SDW-500 Series Manual

image

Contents

1. 2 12345678 m0 Z Full duplex selected 12 2345678 6644 2212 SS J 5 A LOT rE 4 XT settings g et nn Auto negotiation and auto MDI MDI X disabled 123453678 Auto negotiation and auto MDI MDI X enabled 12 345678 ON 10 Mbit s speed selected E 12345678 ON m 100 Mbit s speed selected He 53 5S SB ON Half duplex selected a 12345678 ON L 12345678 Full duplex selected g et settings zu Auto negotiation and auto MDI MDI X disabled a 12345678 goon Auto negotiation and auto MDI MDI X enabled deste 7015 ON 10 Mbit s speed selected E 12345678 ON 100 Mbit s speed selected 12345678 ON Half duplex selected 8 22 5 Se 73 ON E qe oo SS ve Full duplex selected Port mirroring settings m No monitoring selected i 22 57 48 E 12345678 Z Z Monitoring selected Factory settings 11 DIP switch settings SDW 541 and SDW 532 DIP switches are accessible under the lid on top of the unit DIP switches are used to configure the unit Warning Prevent damage to internal electronics from electrostatic discharges ESD by discharging your body to a grounding point e g use of wrist strap before the lid on top front of the unit is removed N Warning Do not open connected equipment Prevent access to hazardous voltages by di
2. is in conformity with the following EC directive s No Short name 89 336 EEG Electromagnetic Compatibility EMC References of standards applied for this EC declaration of conformity No Title Issue EN 61000 6 2 Immunity for industrial environments 2 2001 EN 61000 6 3 Emission standard for residential commercial and 1 2001 light industrial environments 3644 0010 EN 61000 6 4 Emission standard for industrial environments 3644 1 2001 0020 and 3644 0030 The last two digits of the year in which the CE marking was affixed 04 OLY lop 7 000035 7 Hans Levin Technical Manager 15th December2004 Org nr Postadress Postal address Tel Telefax Postgiro Bankgiro Corp identity number Registered office S 640 40 Stora Sundby 016 428000 016 428001 52 72 79 4 5671 5550 556361 2604 Eskilstuna Sweden Int 46 16428000 Int 46 16428001 4 6644 2212 Specification Power interface SDW 500 series Rated voltage 12 48 VDC polarity protected Operating voltage 9 6 57 6VDC Rated current 12VDC power input SDW 550 320mA P SDW 541 MM SC2 450mA Ps SDW 541 SM LC15 450mA SDW 541 SM SC15 350mA 00000 SDW 541 SM LC40 350mA P SDW 541 MM LC2 350mA P SDW 5322 MM SC2 600mA fs SDW 532 2 MM ST2 600mA SDW 5322 SM LC15 450mA P SDW 5322 SM SC15 450mA SDW 532 2 SM LC40 450mA P SDW 5322 MM LC2 450mA SDW 532 MM SC2 SM SC15 450 DC Connection Detachable scr
3. auto MDI MDI X enabled ON 10 Mbit s speed selected a 12345678 ON E 100 Mbit s speed selected a 22 sier 5 27 3 ON Half duplex selected N w o N mo Z Full duplex selected 12345678 6644 2212 S1 2273777 ar LOI 5 ae Port 4 settings Auto negotiation and auto MDI MDI X disabled Auto negotiation and auto MDI MDI X enabled 10 Mbit s speed selected 100 Mbit s speed selected Half duplex selected Full duplex selected N w Setting of port 4 is only possible when using SDW 541 These settings are ignored when using SDW 532 Port mirroring settings No monitoring selected Monitoring selected 13 LED indicators At power on the PWR flashes during initialising Indicators LED Power PWR Link LINK of every port Speed SPD and duplex DPX of TX ports LED Status Indication of PWR ON Internal power initialising OK Slow flash Initialisation progressing Fast flash Initialisation error LINK OFF No Ethernet link Good Ethernet link Ethernet data is transmitted or received traffic indication SPD OFF 10 Mbit s TX only 100 Mbit s DPX OFF Half duplex TX only Full duplex 14 6644 2212 Application example KY wesTermo Westermo Teleindustri AB SE 640 40 Stora Sundby Sweden Phone 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo se Westermo Web site www westermo com Subsidiaries Westerm
4. interface 8 TX shields individually isolated ii Wide DC power range 12 48 VDC 9 6 57 6 VDC operating voltage ii Wide temperature range 8i Redundant power 8i Automatic MDI MDI X crossover si LED indicators for Power Speed Duplex Link and Traffic 8 Port monitoring 8 35 mm DIN rail mounting SC ST and LC fibre interface ii Multi MM and single mode SM fibre Example of applications are ii 5 port switch ii Fibre to copper converter Ethernet isolator for STP network 6644 2212 Declaration of Conformity westerna Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE 640 40 Stora Sundby Sweden Herewith declares that the product s Type of product Model Art no Installation manual DIN rail SDW 550 3644 0010 6644 2212 DIN rail SDW 532 MM SC2 SM SC15 3644 0019 6644 2212 DIN rail SDW 541 MM SC2 3644 0020 6644 2212 DIN rail SDW 541 MM ST2 3644 0021 6644 2212 DIN rail SDW 541 SM LC15 3644 0022 6644 2212 DIN rail SDW 541 MM LC2 3644 0023 6644 2212 DIN rail SDW 541 SM SC15 3644 0024 6644 2212 DIN rail SDW 541 SM LC40 3644 0025 6644 2212 DIN rail SDW 532 2MM SC2 3644 0030 6644 2212 DIN rail SDW 532 2MM ST2 3644 0031 6644 2212 DIN rail SDW 532 2SM LC15 3644 0032 6644 2212 DIN rail SDW 532 2MM LC2 3644 0033 6644 2212 DIN rail SDW 532 2SM SC15 3644 0034 6644 2212 DIN rail SDW 532 2SM LC40 3644 0035 6644 2212
5. voltage exceeding 42 4 V peak or 60 VDC are defined as class equipment with a protective earthing conductor terminal Units with the rated voltage up to 42 4 V peak or 60 VDC are defined as class 111 equipment and shall be separated from hazardous voltage by double or reinforced isolation This unit uses convection cooling To avoid obstructing the air flow around the unit follow the spacing recommendations see Installation section Approvals Conformity with the Directive 73 23 EEC Low Voltage Directive LVD has been assessed by application of the standard EN 60 950 Conformity with the Directive 89 336 EEC Electromagnetic Compatibility EMC has been assessed by application of standards EN 61000 6 2 industrial immunity and EN 61000 6 3 residential emission and EN61000 6 4 Industrial emission 6644 2212 Description The SDW 500 is a series of Industrial Ethernet 5 port switches Several variations are available ranging from a version with five RJ 45 TX copper ports to versions having two FX fibre and three TX ports All TX ports support auto negotiation but DIP switches also allow speed and duplex configuration of any individual TX port It is also possible to set up one port to monitor traffic to from the switch The SDW 500 series has been designed to meet high industrial specifications providing very high dependability in harsh environmental conditions Features ii Flexible mix of TX copper and FX fibre
6. 5000 gy 35 o 6644 2212 5 port Switch www westermo com oOo dS i GdS c AdS seuas 00S MGS B i LE N 3 44111222224 25444244 a eseeecevagae MATT seneeeerea LJ TTTTET maemaonssezxesszmm Safety AS A General Before using this unit read this manual completely and gather all information on the unit Make sure that you understand it fully Check that your application does not exceed the safe operating specifications for this unit Before installation maintenance or modification work Prevent damage to internal electronics from electrostatic discharges ESD by discharging your body to a grounding point e g use of wrist strap Prevent access to hazardous voltages by disconnecting the unit from AC DC mains supply and all other electrical connections Installation This unit should only be installed by qualified personnel This unit should only be installed in a restricted access area for example a lockable cabinet where access is restricted to service personnel only This unit is intended for permanent connection to the AC DC mains supply The power supply wiring must be sufficiently fused and if necessary it must be possible to disconnect manually from the AC DC mains supply Ensure compliance to national installation regulations Units with the rated
7. IP switches the settings of DIP switches configure the unit only after a reboot power off on To be observe when the DIP switches will be configured ii Speed and duplex setting only valid when auto negotiation is disabled ii When monitoring selected all outgoing packets from the switch is also copied to the port 1 ii f auto negotiation and auto MDI MDI X disabled all TX ports support MDI X configuration 10 6644 2212 Port 1 settings oo Auto negotiation and auto MDI MDI X disabled E 12345678 mo 2 Auto negotiation and auto MDI MDI X enabled 12 3245678 ON 10 Mbit s speed selected E 12345678 0 2 100 Mbit s speed selected SS 74 8 ON Half duplex selected 8 22 Se 7 ON E a 22 2456778 Full duplex selected g et N settings Auto negotiation and auto MDI MDI X disabled L a 22 8 4r Se xs Auto negotiation and auto MDI MDI X enabled al 22 shor EG x i ON 10 Mbit s speed selected ie SS 7 On 100 Mbit s speed selected al 92 BS 2 6 On Half duplex selected Sar Sows ON E 2 Full duplex selected ES et UJ settings Auto negotiation and auto MDI MDI X disabled a 12345678 Ln m Auto negotiation and auto MDI MDI X enabled a 22 sien 5 27 3 ON m 10 Mbit s speed selected 12 Sar SS 74 i ON E 100 Mbit s speed selected 12345678 Half duplex selected
8. d obstructing the airflow around the unit use the following spacing rules Recommended spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Snap on mounting see figure 10 mm 0 4 inches Spacing left right recommended 25 mm for full operating temperature range Removal Press down the black support at the back of the unit see figure 6644 2212 7 Connections LED indicators Network RJ 45 connection Network Fibre connection or RJ 45 connection Power connection Available models 8i SDW 550 10 100Base T TX 5 ports ii SDW 541 10 100Base T TX 4 ports 100Base FX 1 port ii SDW 532 10 100Base T TX 3 ports 100Base FX 2 ports NOTE SDW 532 MM SC2 SM SC15 Port 4 SC Single mode 15 km connector Port 5 SC Multi mode 2 km connector 8 6644 2212 Power AQ The SDW 500 series supports redundant power connection Lii The positive input VB the negative input 9 for both supplies COM The power is drawn from the input with the highest voltage 3 pos screw terminal Description Power A 9 6 57 6 VDC 9 6 57 6 VDC TX Ethernet TX connection RJ 45 connector automatic MDI MDI X crossover Contact Signal Name Direction Description Remark TD In Out Transmitted Received data 3 TD In Out Transmitted Received data RD I
9. ew terminal 0 2 2 5 mm AWG 24 12 Ethernet TX Interface Electrical specification IEEE std 802 3 2000 edition Data rate 10 Mbit s or 100 Mbit s manual or auto Duplex Full or half manual or auto Connection RJ 45 shielded Circuit type TNV 1 Transmission range 100 m Fibre optic specification IEEE std 802 3 2000 edition multi or single mode 1300 nm Data rate 100 Mbit s Duplex Full Connection SC ST or LC Transmission range 2 15 or 40 km Position Direction Product marking Rx n Tx Out Transmit port Direction relative this unit Dimension W x H x D 35 x 121 x 119 mm Weight 0 2 kg Mounting DIN rail Degree of protection IP21 6644 2212 5 Isolation between interfaces Power Interface to all other 2 8 kV DC 2 0 kV RMS 50 Hz and 60 s duration TX signal Interface to all other 2 1 kV DC 1 5 kV RMS 50 Hz and 60 s duration TX shield Interface to all other 1 5 kV DC 1 0 kV RMS 50 Hz and 60 s duration Environmental Temperature operating 25 to 70 C SDW 550 25 to 65 C SDW 541 25 to 60 C SDW 532 Temperature storage and transportation 25 to 70 C Relative humidity operating 5 to 9576 non condensing Relative humidity storage and transportation 5 to 9576 condensation allowed outside packaging Configuration Auto configured auto negotiation or manually setting of speed and duplex of individual TX port by DIP switches Port mirr
10. n Out Transmitted Received data a Lo In Out Transmitted Received data 8 Shield HF connected CAT 5 cable is recommended Unshielded UTP or shielded STP connector might be used FX SC Multi or single mode optional Ethernet FX connection 1300 nm multi or singlemode fibre tranceiver with SC connector The dust protection plug shall be mounted when no fibre is connected Ethernet FX connection 1300 nm multi mode fibre tranceiver with ST connector The dust protection plugs shall be mounted when no fibre is connected ti a FX ST Multi mode optional B FX LC Multi or single mode optional Ethernet FX connection 1300 nm singlemode fibre transceiver with LC connector The dust protection plug shall be mounted when no fibre is connected 6644 2212 DIP switch settings SDW 550 DIP switches are accessible under the lid on top of the unit DIP switches are used to configure the unit Warning Prevent damage to internal electronics from electrostatic discharges ESD by discharging your body to a grounding point e g use of wrist strap before the lid on top front of the unit is removed VAN Warning Do not open connected equipment Prevent access to hazardous voltages by disconnecting the unit from AC DC mains supply and all other electrical connections NOTE When configuration via D
11. o OnTime AS Westermo Data Communications GmbH Gladsvei 20 0489 Oslo Norway Goethestra e 67 68753 Wagh usel Phone 47 220 903 03 Fax 47 220 903 10 Tel 49 0 7254 95400 0 Fax 49 0 7254 95400 9 E mail contact ontimenet com E Mail info westermo de Westermo Data Communications Ltd Westermo Data Communications S A R L Talisman Business Centre Duncan Road 9 Chemin de Chilly 91160 CHAMPLAN Park Gate Southampton SO31 7GA T l 33 1 69 10 21 00 Fax 33 1 69 10 21 01 Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E mail infos westermo fr E Mail sales westermo co uk Westermo Teleindustri AB have distributors in several countries contact us for further information REVB 6644 2212 05 09 Malartryck AB Eskilstuna Sweden
12. or function is possible to set with DIP switch With the port mirror function active the switch will copy all outgoing traffic to port 1 This can be used to monitor all traffic going out from the switch Packets may be discarded if the total throughput exceeds the port speed of port 1 Fibre optic power budget Model Multimode Singlemode Singlemode Singlemode MM xx2 SM SC15 SM LC15 SM LC40 Recommended fibre cable 50 125 9 125 9 125 9 125 and core cladding diameter 62 5 125 10 125 10 125 10 125 Fibre type Normal attenuation Normal attenuation 1310 nm multimode 1310 nm singlemode Mons asns 95 Am 71 mons T Attenuation in connectors splices Type Normal attenuation 0 2 0 4 dBm 0 1 dBm Mechanical splice 0 2 dBm 6 6644 2212 Maintenance No maintenance is required as long as the unit is used as intended within the specified conditions N Installation Mounting Removal Before mounting or removing the unit Prevent damage to internal electronics from electrostatic discharges ESD by discharging your body to a grounding point e g use of wrist strap Prevent access to hazardous voltages by disconnecting the unit from AC DC mains supply and all other electrical connections Mounting This unit should be mounted on 35 mm DIN rail which is horizon tally mounted on a wall or cabinet backplate This unit uses convection cooling To avoi
13. sconnecting the unit from AC DC mains supply and all other electrical connections NOTE When configuration via DIP switches the settings of DIP switches configure the unit only after a reboot power off on To be observe when the DIP switches will be configured ii Speed and duplex setting only valid when auto negotiation is disabled i When monitoring selected all outgoing packets from the switch is also copied to the port 1 ii Speed and duplex switch settings are ignored for FX ports ii If auto negotiation and auto MDI MDI X disabled all TX ports support MDI X configuration 12 6644 2212 Port 1 settings ON Auto negotiation and auto MDI MDI X disabled E 12345678 m0 Z Auto negotiation and auto MDI MDI X enabled 12345678 ON 10 Mbit s speed selected E TASA ea 0 Z 100 Mbit s speed selected 12345678 ON Half duplex selected T2345 ON Full duplex selected 12345678 U et N settings nn Auto negotiation and auto MDI MDI X disabled E 123245678 Soon Auto negotiation and auto MDI MDI X enabled 12 32456778 ON 10 Mbit s speed selected E 12345678 ON 100 Mbit s speed selected 8 22 sie be x i ON Half duplex selected il 22 SS 27 3 on Full duplex selected i224 55167728 g et w settings oo Auto negotiation and 423456 auto MDI MDI X disabled on m Auto negotiation and gt