Home
Ethernet over VDSL2 Converter VC-201A / VC
Contents
1. A 1n4 10 100Base TX Port LED Color Function Light Indicates that the port is Link Up Indicates that the Converter is actively PIGGY erect Bink sending or receiving data over that port Off Indicates that the port is Link Down Indicates that the port is operating at Light 5 ooMbps 100 Green Indicates that the port is Link Down or or 10Mbps 2 2 The Rear Panel The rear panel of the Ethernet over VDSL2 Converter is shown below VC 201A VC 202A Rear Panel Mode Channel Band Plan SNR Figure 2 3 VC 201A VC 202A Rear Panel 2 2 1 DIP Switch Mode The Ethernet over VDSL2 Converter provides 4 selective transmission modes By switching the transmission mode you can obtain the best transmission mode to suit with phone line quality or distance of connectivity The following is the summary table of transmission setting bandwidth and distance 15 1 extensibility tested for AWG 24 0 5mm twisted pair without noise and cross talk DIP 1 DIP 2 DIP 3 DIP 4 Mode Channel Band Plan SNR OFF co Interleave Symm 9dB ON default CPE Fast Asymm 6dB CO CPE CO Central Office the Master device mode usually the CO device will be located at the data center of ISP or enterprise to link to the backbone e CPE Customer Premises Equipment the Slave device mode usually the CPE device will be located at bra
2. Selectable fast and interleaved mode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a Support LED Indicators One Power 3 for RJ 11 VDSL2 2 for RJ 45 10 100Base TX port One Power 3 for RJ 11 VDSL2 2 for RJ 45 10 100Base TX port 10Base T 2 pair UTP Cat 3 4 5 up to 100m up to 1 6km Ethernet 3486 100Base TX 2 pair UTP Cat 5 5e 6 up to 100m 328ft Cabling Twisted pair telephone 50 ohm RG58A U VDSL wires AWG24 or better RG58C U RG58 U or 75 ohm RG6 Distance 3 0km Asymmetric Mode 200m gt 100 55Mbps 400m gt 90 50Mbps 600m gt 70 40Mbps 800m gt 60 25Mbps 1000m gt 45 15Mbps 1200m gt 35 10Mbps 1400m gt 30 6Mbps 1600m gt 25 4Mbps 200m gt 100 65Mbps 400m gt 100 64Mbps 600m gt 100 59Mbps 800m gt 100 53Mbps 1000m gt 94 44Mbps 1200m gt 84 36Mbps 1400m gt 74 28Mbps 1600m gt 66 19Mbps 1800m gt 60 14Mbps 2000m gt 44 15Mbps 2200m gt 35 12Mbps 2400m gt 32 10Mbps 2600m gt 29 8Mbps 2800m gt 27 6Mbps Performance 3000m gt 25 5Mbps Downstream 7 Upstream Symmetric Mode 200m gt 100 100Mbps 200 gt 100 100Mbps 400m gt 90 95Mbps 400m gt 97 100Mbps 600m gt 70 70Mbps 600m gt 86 91Mbps 800m gt 55 50Mbps 800m gt 79 80Mbps 1000m gt 45
3. Ethernet LAN 1 Set the VC 202A to be CO or CPE mode from the DIP switch on the rear panel 2 Power on the VC 202A by connecting its power source 3 Power LED will illuminate 4 Connect coaxial cable from another VDSL device to VDSL BNC port of the VC 202A 5 LNK LED will illuminate 6 Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 5e or 6 cables VC 202A 7 VDSL er Twisted Pair Cable G o A im RG58 RG6 RG58 Jack Fast Ethernet Switch Figure 3 6 Connecting Multiple PCs to an Ethernet LAN Please refer to your Ethernet device User s Manual for the device s setup information 3 4 Chassis Installation and Rack Mounting VC 201A and 202 To install the Ethernet over VDSL2 Converter in a 10 inch or 19 inch Converter Chassis with standard rack follow the instructions described below 34 22 Step 1 Place your VC 201A VC 202A on a hard flat surface with the front panel positioned towards your front side Step 2 Carefully slide in the module until it is fully and firmly fitted into the slot of the converter chassis Figure 3 7 Insert a VDSL2 Converter Into an Available Slot Step 3 Attach a rack mount bracket to each side of the Converter Chassis with supplied screws attached to the package Step 4 After the brackets are attached to the Converter Chassis use suitable screws to securely attach the brackets to
4. VDSL segment is 3 0km 9842ft over 5C coaxial cable The distance will change by the quality of telephone wires and coaxial cables 3 1 1 VC 201A VC 202A LAN to LAN Connection Two sets of the Ethernet over VDSL2 Converters could be used to link two local Area networks that are located in different places Through the normal telephone line it could set up a 100 55Mbps asymmetric backbone but one Ethernet over VDSL2 Converter must be Master CO mode and the other one is Slave CPE mode LR Router in Up to 1 6km PSTN y 100BaseTX UTP Telephone wire Figure 3 2 VC 202A LAN to LAN Connection 3 2 Connecting VC 201A VC 202A 3 2 1 Connecting Standalone PC Refer to the following procedures to setup the VC 201A to a standalone PC 1 Set the VC 201A to be CO or CPE mode from the DIP switch on the rear panel 2 Power on the VC 201A by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the VC 201A 5 LNK LED will blink to illuminate 6 Connect telephone to the PHONE port 7 Connect Ethernet port to PC Network Interface Card NIC via regular Cat 5 5e or 6 cable 19 1 E VC 201A RJ 11 Line Cord Phone VDSL S Twisted Pair Cable RJ 11 Phone Jack Figure 3 3 Connecting Standalone PC 3 2 2 Connecting Multiple PCs to an Ethernet LAN Refer to the followin
5. and electronic equipment end a users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste they should be collected separately Revision Ethernet over VDSL2 Converter User s Manual For Models VC 201A VC 202A Rev 2 0 April 2014 Part No 2350 AC0270 002 Table of Contents T 5 5 1 2 Ethernet over VDSL2 Bridge Description 5 1 3 Key FOAtureS DE 9 1 4 Specifications irais i a aia 10 2 Hardware Description ese rnt rore enn ia 13 2 1 Front eer REA 13 2 2 The Rear Panel tie 15 3 IE zia rp ant 18 3 1 Installing Ethernet over VDSL2 Converter 18 3 2 Connecting VC 201A 202 tan enai 19 3 3 Connecting 202 dini 21 3 4 Chassis Installation and Rack Mounting VC 201A and VC 202A 22 4 Power Information cse ocesose io ncque ise cese deus lu eai DNUS 24 5 mroubleshootifig eese Ee bete uie usan ente can 25 1 Introduction 1 1 Checklist Check the contents of your package for following parts W VC 201A VC 202A x 1 5V DC 2A AC to DC Power Adapter x 1 RJ 11 Telephone Line x 1 VC 201A only W User s Manual x 1 If any of these items ar
6. the rack Step 5 Proceed with Step 4 and Step 5 of the session 3 2 Stand alone Installation to connect the network cabling and supply power to your Converter Chassis You must use the screws supplied with the A mounting brackets Damage caused to the parts by using incorrect screws would invalidate your warranty Caution 23 1 4 Power Information The power jack of the VC 201A VC 202A is with 2 5mm in the central post and required 5V DC power input It conforms to the bundled AC DC adapter and Planet s Media Chassis If you encounter the issue about the power connection please contact your local sales representative Please keep the AC DC adapter as a spare part when your VC 201A VC 202A is installed in a Media Chassis 2 5mm E DC Receptacle 2 5mm 5V for each slot eco Media Chassis DC receptacle is 2 5mm wide which conforms to and matches the VDSL2 Converter 2 5mm DC jack s central post Do not install any improper devices in Media Chassis A24 5 Troubleshooting SYMPTOM VDSL LNK LED does not light up after wire is connected to the VDSL port CHECKPOINT 1 Verify the length of the wire connected between two VC 201A VC 202A is not more than 2km Please also try to adjust the DIP switch of the VC 201A VC 202A to the other SNR mode 2 Please note you must use one VC 201A VC 202A in CO mode and the other VC 201A VC 202A in CPE mode Connect to ea
7. 35Mbps 1000m gt 69 66Mbps 1200m gt 30 25Mbps 1200m gt 60 52Mbps 1400m gt 25 20Mbps 1400m gt 51 41Mbps 1600m gt 20 15Mbps 1600m gt 45 36Mbps 1800m gt 40 29Mbps 2000m gt 27 26Mbps 2200m gt 23 24Mbps 2400m gt 22 21Mbps 2600m gt 20 18Mbps 2800m gt 18 15Mbps 3000m gt 17 13Mbps Power Requirements 5V DC 2A 11 _ Operating 0 50 degrees Temperature see 10 70 degrees C Temperature Operating A d T Humidity 10 to 90 relative humidity non condensing Storage Humidity 10 to 90 relative humidity non condensing Standard Conformance Part 15 Class A CE Compliance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3x Full Duplex Pause Frame Flow Control Standards ITU T Compliance e G 993 1 VDSL 997 1 e G 993 2 VDSL2 Profile 17a The actual data rate will vary on the quality of the copper wire and environment factors 412 2 Hardware Description VC 201A The VC 201A provides 2 RJ 11 ports for voice connection like telephone and for network line connection VC 202A The VC 202A provides 1 BNC connector and supports 50 or 75 ohm cable with distance up to 3 0km The VC 201A and VC 202A provide 1 RJ 45 port each with two different running speeds 10Mbps and 100Mbps It will distinguish the speed of incoming connection automatically This section describes the ha
8. Ethernet over VDSL2 Converter VC 201A VC 202A User s Manual Trademarks Copyright PLANET Technology Corp 2014 Contents are subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep the current information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital devi
9. What are the best data rates for the VC 201A and VC 202A A4 The data rates of the VC 201A and VC 202A are up to 100Mbps 55Mbps and up to 100Mbps 65Mbps down stream upstream in 200 meters respectively Q5 Is the VC 201 compatible with the VC 201A 5 Currently no Although the VC 201 profile 12a and 34 26 the VC 201A profile 17a are based on ITU T G 993 2 VDSL2 but with different profiles so far they are not compatible with each other Q6 A6 Q7 A7 Q8 8 Is the VC 202 compatible with the VC 202A Currently no Although the VC 202 profile 12a and the VC 202A profile 17a are based on ITU T G 993 2 VDSL2 but with different profiles so far they are not compatible with each other What is SNR and what s the effect In analog and digital communications Signal to Noise Ratio often written as SNR is a measure of signal strength relative to background noise The ratio is usually measured in decibels dB In digital communications the SNR will probably cause a reduction in data speed because of frequent errors that require the source transmitting computer or terminal to resend some packets of data SNR measures the quality of a transmission channel over a network channel The greater the ratio the easier it is to identify and subse quently isolate and eliminate the source of noise Generally speaking the higher SNR value gets better line quality but lower performance W
10. ce pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Energy Saving Note of the Device This power required device does not support Standby mode operation For energy saving please remove the DC plug or push the hardware Power Switch to OFF position to disconnect the device from the power circuit Without removing the DC plug or switch off the device the device will still consume power from the power source In the view of Saving the Energy and reduce the unnecessary power consuming it is strongly suggested to power off or to remove the DC plug for the device if this device is not intended to be active WEEE Warning To avoid the potential effects on the environment and K human health as a result of the presence of hazardous substances in electrical
11. ch other to make it work SYMPTOM TP LED does not light up after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 5e or 6 cables with RJ 45 connector connected to the port N If your device like LAN card supports auto negotiation please try to modify at a fixed speed of your device manually o Check whether the converter and the connected device s power are ON or OFF 4 Check whether the port s cable is firmly seated in its connectors in the switch and in the associated device 5 Check whether the connecting cable is good 6 Check whether the power adapters are functional including the connecting device 25 1 6 FAQs Q1 What voltage do the VC 201A and VC 202A use 1 5V DC 2A Q2 What is VDSL2 A2 VDSL2 Very High Bit Rate Digital Subscriber Line 2 G 993 2 is the newest and most advanced standard of xDSL broadband wire line communications Designed to support the wide deployment of Triple Play services such as voice data high definition television HDTV and interactive gaming VDSL2 enables opera tors and carrier to gradually flexibly and cost efficiently upgrade the exiting xDSL infrastructure Q3 What is the best distance for the VC 201A and VC 202A A3 In order to guarantee the stability and better quality of network so we would suggest the distance within 1 6 kilo meter is the best for the VC 201A and 3 0 kilometer for the VC 202A Q4
12. e missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them again to repack the product in case there is a need to return it to us for repair 1 2 Ethernet over VDSL2 Bridge Description PLANET s state of the art Ethernet over VDSL2 products are based on two core networking technologies Ethernet and VDSL2 Very high data rate Digital Subscriber Line 2 This technology offers the absolutely fastest possible data transmission speeds over existing copper telephone lines or coaxial cables without the need for rewiring The VC 201A VC 202A Ethernet Over VDSL2 Converter has a switching architecture with RJ 45 10 100Mbps Ethernet port and one asymmetric or symmetric Ethernet over VDSL port Asymmetric means upstream and downstream rates are not the same while symmetric means upstream and downstream rates are similar the VDSL port can be RJ 11 connector VC 201A or BNC Connector VC 202A The VC 201A VC 202A can be set to Central Office CO or Customer Premises Equipment CPE mode via a DIP switch When VC 201A CO is connected with the other VC 201A CPE device the performance will go up to 100 55Mbps for asymmetric 5R1 data rate within 200m and up to 25 4Mbps for asymmetric data rate at 1 6km The VC 202A BNC performance is up to 100 65Mbps for asymmetric data rate within 200m and up to 25 5Mbps for asymmetric data rate at 3 0km T
13. g procedures to set up the VC 201A to an Ethernet LAN 1 Set the VC 201A to be CO or CPE mode from the DIP switch on the rear panel 2 Power on the VC 201A by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the VC 201A 5 LNK LED will illuminate 6 Connect telephone to the Phone port 7 VC 201A Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 5e or 6 cables Router yu Coaxial Cable E Up to 2 0km Switch Figure 3 4 Connecting Multiple PCs to an Ethernet LAN 34 20 Please refer to your Ethernet device User s Manual for the device s setup information 3 3 Connecting VC 202A 3 3 1 Connecting Standalone IP Device Refer to the following procedures to set up the VC 202A to a standalone PC 1 Set the VC 202A to be CO or CPE mode from the DIP switch on the rear panel 2 Power on the VC 202A by connecting its power source 3 Power LED will illuminate 4 Connect coaxial cable from another VDSL device to VDSL BNC port of the VC 202A 5 LNK LED will blink for illuminating 6 Connect Ethernet port to Ethernet device via regular Cat 5 5e or 6 cables VC 202A VDSL a BNC TP SS RIS Cat 5 Twisted Pair Cable 9 RG58 Jack IP Camera Figure 3 5 Connecting Standalone IP Device 21 3 3 2 Connecting Multiple PCs to an
14. hat is band plan and what s the effect VDSL2 defines multiple band plans and configuration modes profiles to allow asymmetric and symmetric services in the same binder by designated frequency bands for the transmission of upstream and down stream signals User has the ability to select fixed band plan Symmetric is selected to provide better downstream performance while asymmetric is selected to provide better upstream performance 27 3 GQ PLANET Networking amp Communication EC Declaration of Conformity For the following equipment Type of Product Ethernet over VDSL2 Converter Model Number 201 VC 202A Produced by Manufacturer s Name Planet Technology Corp Manufacturer s Address 10 No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan R O C is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility 2004 108 EC For the evaluation regarding the Electromagnetic Compatibility the following standards were applied EN 55022 2010 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 55024 1998 1 2001 A2 2003 EN 61000 4 2 2009 EN 61000 4 3 2006 A2 2010 EN 61000 4 4 2004 A1 2010 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 8 2010 EN 61000 4 11 2004 Responsible for marking this declaration if the Manufact
15. his capability is ideal for use as an Ethernet extender for your existing Ethernet network PLANET VDSL2 Converter provides a much cheaper replacement and smooth migration for existing Long Reach Ethernet LRE networks The cable specifications of the connection are listed as follows m 10Base T Category 3 4 or 5 UTP m 100Base TX Category 5 5e or 6 UTP W Ethernet over VDSL2 twisted pair telephone wires W Ethernet over VDSL2 coaxial cable The two drawings are typical applications for the Ethernet over VDSL2 Converter Slave device CPE must connect to Master device CO through the telephone wire or coaxial cable Connecting Master to Master or Slave to Slave is not allowed For the detailed definition of the VC 201A VC 202A to CO or CPE please refer to section 2 2 1 LAN to LAN Connection Existing Telephone Network G Main office PBX Telco CO wire closet Ethernet over VDSL and Telephone Network Up to 1 6km Main office PBX Telco CO wire closet VC 201A CPE 22 Up to 1 6km Main office PBX Telco CO wire closet VC 204 VC 204 co CPE Coaxial Cable Up to 3 0km 100Base TX UTP 1 1 Telephone wire Multi LAN Connection Existing Telephone Network Main office PBX Telco CO wire closet Main office PBX Telco CO wire closet vc 204 Coaxial CAM Viewer 1 1 1 1 1 1 1 Ethernet 1 1 J Switch C
16. nch office home or remote side as the long reach data receiver The CPE can be connected to the PC IP Camera or Wireless Access Point and etc network devices When the Ethernet Over VDSL2 Converter oper ates in CPE mode the DIP switch 2 3 4 is not functional W Fast and Interleaved Mode e Fast mode guarantees a minimum end to end latency less than 1 ms Interleaved mode provides impulse noises protection with a duration less than 250 us Interleaved mode has a maximum end to end latency of 10m sec W Band Plan User can switch the Band Plan either Symmetric or Asym metric by their own Symmetric is selected to provide better upstream performance Asymmetric is selected to provide better downstream performance Refer to the table above for details Target SNR Signal Noise Ratio Margin e When fixed SNR margin is selected the system will maintain the SNR margin at 9 dB across all usable loop lengths By default setting the fourth DIP switch is at ON position and operates as CPE To operate as CO please adjust DIP 1 switch to OFF position Adjust the other DIP switch setting to meet different network application demands Please power off the Ethernet over VDSL2 Converter before making any transmission mode adjustment 2 2 2 DC Power Jack The VC 201A and VC 202A require 5V DC power input It will conform to the bundled AC adapter If you have the issue about the power c
17. oaxial IP Camera 100Base TX UTP Telephone wire 0058 VDSL Coaxial Cable 1 1 1 D 1 3 Key Features The Ethernet Over VDSL2 Converter provides the following key features W Cost effective VDSL2 CO CPE bridge solution W One box design CO CPE selectable via DIP Switch Defines Asymmetric Band Plan 998 and Symmetric band plans for the transmission of Upstream and Downstream signals W Complies with IEEE 802 3 IEEE 802 3u and IEEE 802 3x standards W DMT Discrete Multi Tone line coding W Half duplex back pressure and IEEE 802 3x full duplex pause frame flow control W Built in POTS splitter to share voice and data VC 201A W Voice and data communication can be shared on the existing telephone wire simultaneously VC 201A W Supports up to 1536 bytes packet size 802 1Q VLAN tag transparent W VDSL2 Stand Alone transceiver for simple bridge modem application W Selectable Target Band Plan and Target SNR Margin W Supports extensive LED indicators for network diagnostics 91 1 4 Specifications Product VC 201A VC 202A Hardware Specifications 10 100 1x RJ 45 ix RJ 45 l Base TX Auto negotiation Auto negotiation Auto MDI MDI X Auto MDI MDI X 1 x RJ 11 1 x BNC B ce female Phone Jack female connector 1 x RJ 11 Built in PHONE splitters for POTS connection DIP Switch 4 position DIP switch Functionality e CO CPE mode select
18. onnection please contact your local sales representative 1 The device is power required device meaning it will not work till it is powered If your networks should be active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network down time In some areas installing a surge suppression device may also help to protect your Ethernet Over VDSL2 Converter from being damaged by unregulated surge or current to the Ethernet over VDSL2 Converter or the power adapter 17 1 3 Installation 3 1 Installing Ethernet over VDSL2 Converter The Ethernet over VDSL2 Converter does not require any software configuration Users can immediately use any feature of this product simply by attaching the cables and turning the power on There are some key limitations on the Ethernet over VDSL2 Converter Please check the following items W VC 201A The device is used for Point to Point connec tion only Master device to Slave device and has equipped with 2 RJ 11 connectors for VDSL port One for voice device connection like telephone and the other one for network link connection Depending on the quality of telephone line the maximum distance of one VDSL segment is 1 6km 6561ft with AWG 24 telephone wires W VC 202A 1 BNC connector that supports 50 or 75 ohm cable Depending on the quality of coaxial cable the maximum distance of one
19. rdware features of the Ethernet over VDSL2 Converter For easier control of the converter familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device to the converter read this chapter carefully 2 1 Front Panel The units front panel provides a simple interface monitoring the Ethernet over VDSL2 Converter VC 201A Front Panel TPS Phone vs g DN VC 201A CO CPE Ethernet over VDSLQ Converter Figure 2 1 VC 201A Front Panel 202 Front Panel 202 VDSL CPE Ethernet over VDSL Converter Figure 2 2 VC 202A Front Panel 2 1 1 LED Indicators for VC 201A and VC 202A The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system W System LED Color Function PWR Green Light Power ON Off Power OFF VDSL LED Color Function LNK ACT Light Indicates that the VDSL link is established Fast Green Blink Indicates that the VDSL link is in training status about 10 seconds Slow Blink Indicates that the VDSL link is in idle status CO Green Light Indicates the VDSL Bridge is running in CO mode CPE Green Light Indicates the VDSL Bridge is running in CPE mode
20. urer Authorized representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp Company Address 10F No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan R O C Person responsible for making this declaration Name Surname Kent Kang Position Title Product Manager th zm Taiwan 16 Dec 2013 Place Date Legal Signature PLANET TECHNOLOGY CORPORATION e mail sales planet com tw http www planet com tw 10F No 96 Minquan Rd Xindian Dist New Taipei City Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528
Download Pdf Manuals
Related Search
Related Contents
WD TV Live Streaming Media Player User Manual StarTech.com 7 ft Cat 6 Red Molded RJ45 UTP Gigabit Cat6 Patch Cable - 7ft Patch Cord Installation manual Clique no botão Start [Iniciar] HOME THEATER LED PDF / 121k Jarden HDM076DQ-60 personal scale TCL SERVICE MANUAL Massive Table lamp 12966/01/91 Copyright © All rights reserved.