SR1000 user manual

image

Contents

1. 6 1 2 The connection between this unit and the computer is as follows Computer Power Inverter so TXD TXD GND GND DTR DSR RTS CTS 21 ELECTRONICA AMV OND1000 X C1 6 1 3 The RS232 interface of this unit employs ASCII code to implement the asynchronous serial transmission control The byte structure is START BIP 8 BIT DATA STOP BIT Baud rate 1200 2400 4800 9600 See details in Section 5 3 1 6 1 4 Coupled with PC software application port Operation is as detailed in Section 6 2 6 2 Interface Commands The buffer size used for the RS232 port is 12 byte This unit will ignore all bytes more than this value During transmission this unit will indicate it is ready to receive data from computer by this DTR line A computer has to check the DTR line before sending any information to this unit This unit is normally always ready to receive data while operating When a LF character ASCII code OAH is received this unit would finish the receiving by clearing the DTR status and begin to interpret the received information The unit would execute the received command AND OR data if it is correct Irrespective of whether the command is accepted or not the unit will always send back a response signal to the computer and set DTR to ready for receiving more incoming information 6 2 1 The Baud rate of the RS232 interface can be set with the help of the Setup Menu See details in Section 5 3 1 Note Yo
2. sss 15 5 3 Setup Menu Operation and Instructions eee 16 RS232 Communication and cece eee nese eee 21 6 1 Operation of RS 232 Serial POE diaria 21 6 2 Intemace COMMMANG M rreme rE 22 6 3 Example of RS232 rnnr rent 22 s Informatio AAPP Mt 26 TAL Troubleshooting suse usce ud UR e 26 WAM E 27 ELECTRONICA AMV OND1000 X C1 1 Important Safety Instructions WARNING SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the inverter 1 1 General Safety Precautions 1 1 1 Do not expose the inverter to rain snow spray or dust To reduce the risk of fire hazard do not cover or obstruct the ventilation openings and do not install the inverter in a zero clearance compartment 1 1 2 To avoid the risk of fire and electric shock make sure that the existing wiring is in good electrical condition and that the wire size is not undersized Do not operate the inverter with damaged or substandard wiring 1 1 3 Depending on the use the AC output of the inverter may require user installed breaker or fusing For tel
3. Dry contact terminals may be connected to a Form C relay for FAULT indication When FAULT occurs the relay switches NOTE Fault conditions include Input under over voltage Output Short Circuit Over Temperature Over load and Fan Failure Specifications of the Relay Maximum Load acd CT Number of Operating Storage Voltage N C operations Temperature 240 VAC ree m 100 000 240 VAC Ress 8A 30 VDC Resistive 16A 30C 70C 30 VDC Resistive 8A AM AMV OND1000 X C1 ELECTRONICA Remote Control Terminal Dry Contact Terminal RELAY Normally closed contact Normally open contact 3 1 7 DC Input Connection Follow the instructions to connect the battery cables to the DC input terminals of the inverter The cables should be as short as possible less than 6 feet 1 8 meters ideally so that they can handle the required current in accordance with the Electrical Codes and Regulations The size of the cable should be thick enough to limit the voltage drop to less than 2 when carrying the maximum input current to prevent frequent low input voltage warnings and shutdown UVP Under Voltage Protection warning may result if there is excessive voltage drop across the DC cables between the batteries and the inverter Increasing your DC cable size will help improve the situation Batteries are capable of providing very large currents in case of short cir
4. Output 3Min Output Voltage 194 246 VAC User selectable Short Circuit Protection Output Waveform Pure Sine Wave THD lt 2 LCD Panel 2 Lines LCD Panel with keypad for navigation ignal and Control 7 LL LED Indicator Red Orange Green LED Dry Contact Terminal By a relay Remote Control Terminal Controls the inverter ON OFF operation Input Protection Over Under Voltage Reverse Polarity Internal Fuse Protection A AC Output Protection Short circuit Overload AC Input Protection 6Amp Circuit Breaker Temperature protection Shutdown Internal temperature S65 C Relay Specification 12 Amp 250 VAC Transfer Relay gt Bypass relay On Line Off Line Haphazard Normal Exacting selectable Switching Time From AC bypass mode Off iine Mode S9mS From DC to AC inverter mode On line Mode g7mS Operating Full Load 0 C 50 C i icati tact ES Operation and Failure Indication Buzzer alarm and dry contac Indicator Switches On when Temperature 55 C or Load 30 Switches Off when Temperature 45 C and Load 20 Mechanical Size WXHXD 19 x1 71 x13 6 482 6mmX43 5mmX345mm ee e eH Safety and EMI EMC Safety Standards Meets UL 60950 Meets EN60 950 1 EMC standards FCC CLASS B EN55022 1998 A1 2000 A2 2003 CLASS B EN55024 1997 A1 2001 a2 2003 EN61000 3 2 2006 Class A EN61000 3 3 11995 A1 2001 Note The specifications are subject to change without notice AMV OND1000 X C1 ELECTRONICA 2 4 Mechanical Draw
5. af VES240 Vo 115 FQ 60 0 1o 85 LCD DIS SELECTION LCD PLAY DISPLAY BUTTONS LED s IN INDICATORS MA FANCD FAN 2 FANC3 SWITCH VENTILATOR VENTILATOR VENTILATOR 3 2 1 Main Switch These are the 3 stage rocker switches for turning on turning off and remote mode 3 2 2 LED s Indicators See details in Section 5 1 3 2 3 LCD Display Selection Buttons Data pertaining to the DC input voltage AC output voltage AC output frequency AC output current etc and system status can be shown sequentially on the LCD display by pressing these buttons Please refer to chapter 5 for more information 3 2 4 FAN ventilation grille 1 3 The fans behind the ventilation grilles provides cooling DOT NOT obstruct these vents 3 3 Maintenance 3 3 1 Make sure that the fan vents are not blocked 3 3 2 Use a vacuum cleaner to remove any dust from the fan area 3 3 3 When cleaning the case or front panel use a soft dry cloth only If the case or front panel is very dirty use a neutral non abrasive detergent Do not use alcohol or ammonia based solutions 3 3 4 Regular service and relocation of the inverter should be performed by a qualified service technician 3 3 5 Avoid spilling liquid on the inverter 4 Operation 4 1 Connecting the input power Before making the DC input side connections the main switch must be OFF 4 2 Connecting the loads 6 Calculate the total power consumption W
6. of the output load Make sure that the total power consumption does not exceed the rated load l Should the total load exceed the rated capacity of the inverter remove the non critical loads until the rated total has been reached ELECTRONICA AMV OND1000 X C1 4 3 Inverter Operation Set the power switch to the ON position The buzzer will sound beep beep The inverter will carry out self diagnosis and the LED s will also appear various colors At the same time the LCD will display SR 1000 INVERTER INITIALIATION Finally the buzzer will sound another beep and the INVERTER and status LED s will turn Green The LCD Display will display Vi Vo FQ lo THE inverter will start operating normally l Set the power switch to the OFF position THE inverter stops and all the lights that are on will go off 4 4 Protections Features Ec ase es n 5 Front LCD Panel Display Setup 5 1 LCD Panel Indications 5 1 1 Set the Power Switch to the ON position THE inverter starts working normally The inverter will be operating in normal condition when either of the following messages are displayed on the LCD screen PURE SINE WAVE INVERTER Vi 24 0 Vo 115 FQ 60 0 lo 8 5 LED s LCD LED DISPLAY INDICATORS DISPLAY SELECTION BUTTONS AMV OND1000 X C1 ELECTRONICA 5 1 2 LED Indications 6 AC GRID Displays AC input status AC input and DC AC Inverter Output are Synchron
7. Contact Relay will open close See details in Section 3 1 6 Default 12 VDC for 24 V Model 42 VDC for 48 V Model SETTING VALUE RANGE 24 V 19 VDC 23 VDC 48 V 38 VDC 46 VDC NOTE The value of voltage set for the UV Alarm should be equal to or higher than the value set for UVP or else the unit will shutdown without any audible warning 5 3 3 O P Parameters 11 O P Voltage Set the inverter output voltage Default 110 VAC for 110 V Model 230 VAC for 220 V Model SETTING VALUE RANGE 97 VAC 123 VAC 110V 194 VAC 246 VAC 220 V 12 O P Frequency Set the inverter output frequency Default 60 Hz for 110 V Model 50 Hz for 220 V Model SETTING VALUE RANGE 47 Hz 63 Hz 47 Hz 63 Hz 110 V 220 V 13 Sync Frequency Sets the AC output synchronous frequency Example AC input 230 VAC 50Hz User setting Value 7Hz When the DC to AC inverter Frequency is within the Range of 43 Hz 57 Hz the internal transfer relay will operate normally When the Frequency is less than 43 Hz or more than 58 Hz the internal transfer relay will de energize See details in Section 2 2 Default 0 1Hz 7 Hz SETTING VALUE RANGE 0 1 Hz 7 Hz 0 1 Hz 7 Hz 19 110V 230 V ELECTRONICA AMV OND1000 X C1 14 Bypass Relay The setup is provided in one of the following two ways On line Mode or Haphazara Off line Mode Exacting Normal Default Normal Off line Transfer Relay Switching Feature
8. Output Voltage appears on the PC screen 4 Command to query the Output Current Format AMP After Enter the units Output Current appears on the PC screen 5 Command to query the Input Battery Voltage Format BAT After Enter the units Input Voltage appears on the PC screen 6 3 3 Command for accessing Setup Menus and adjusting values 1 Select the Setup Menus with the help of Function Codes Format FUNC Function Code After Enter the Setup Menu for the Function Code will be called The Function Code gt 0 17 as follows 0 LCDConrst 8 UVP Recovery 1 LCDAutoof 10 UVAlam 2 JjRS232Baudrse 11 O P Voltage 5 NOT USED 14 BypassRelay 6 OVPSeting 15 Overload Alarm 8 UVPSeting 17 NOT USED 23 Tire AMV OND1000 X C1 2 Command to query the Functions No Format FUNC After Enter the units Function Code appears on the PC screen 3 Command to query the set value of the Function Format SETT After Enter the existing set value of the function appears on the PC screen 4 Command to set or adjust the value of the Function Format SETT value After Enter the new value of the Function is set Choose the value of the function as follows NC 0 LCL Contra ETT value 0 100 FUNC 1 LCD Auto off Setting Menu SETT value LCD Auto off Disable 250 FUNC 2 RS232 Ba
9. Sosa Ss EIS MELE sates e gt m gt i 8 3 321 32 20 9 gt o 2 e 3 20 o o D 7 7 7 7 7 o o o 7 7 o o N 0 o o o 0 0 0 0 0 o 77 z z N N o e a a o seg l Sl 3 3 S S 5 ol 0 mn tre Ss 1 m ov jo a eco gel feas lt f ee nn Setting 12 5 s LE silos 85115 5 1 e 5 Value Z s Moz 5 2 fas me 6 5 a o o E O o a 0 E LL D 8 a X 5 olg a e 9 O O dp e 2 2 gt gt gt 4 a m O 5 O 0 m O 5 3 1 User interface Select Menu 0 LCD Contrast Sets LCD screen contrast Default 50 Setting Range 0 100 1 LCD Auto off Sets LCD auto off timer Default 120 seconds Setting Range Disable 250 seconds 2 RS232 Baud rate Sets standard RS 232 Baud rate Default 4800 Setting Range 1200 2400 4800 9600 3 Buzzer Setting Sets the internal buzzer sound ON OFF When setting the LCD screen display Buzzer ON Buzzer OFF Default MSG Alert SHDN Setting Range Disable Shutdown Alert Alert SHDN Message Message SHDN Message Alert MSG Alert SHDN AMV OND1000 X C1 ELECTRONICA MENU STATUS BUZZER Power ON or Push Keypad ON FAN Fail or UV Alarm or Overload Alarm ON Shutdown OVP or UVP or OLP or OTP 4 Alert Setup When alert occurs the internal Dry Contact Relay will open close See deta
10. AC diro ed Black 120 VAC Brown 230 VAC 14 16 AC INPUT Neutral N White 120 VAC Blue 230 VAC 26 32 feet AWG Chassis Ground or FG Green Yellow or Bare copper 12 14 Note Please double check and review all the connections to ensure that the wires are connected to the correct terminals and that the connections are tight 110VAC 230VAC 3 1 4 Chassis Ground Must be connected to earth ground prior to making any other connections to the equipment 3 1 3 AC output socket 3 1 5 RS 232 Serial port monitoring and control through computer interface 3 1 6 Remote control and Dry contact terminal RELAY GROUND Normally Colsed ENABLE Common ENABLE Nornolly Open AMV OND1000 X C1 ELECTRONICA Remote Control Terminal 1 Before installing the inverter ensure that the main switch OFF 2 Before using the remote function ensure that the main switch pressed toward REMOTE 3 Ensure that the remote contacts are off 4 Use 20 24 AWG wire to connect the remote control terminals 5 Remote control ON OFF inverter setup status ENB ENB ON INV ON HIIINV ON TR ON OFF INV OFF LOW INV OFF TR OFF GND GND ON INV ON AN OFFINV OFF ON INV ON DC OFF INV OFF NOTE At one time only one remote function should used to control the inverter The maximum voltage value is the same as input DC voltage l Dry Contact Terminals
11. ELECTRONICA AMV OND1000 X C1 1KW Pure Sine Wave Power Inverter User s Manual AMV ELECTR NICA SL C NAVA N 7 BAJO 33207 GIJON ASTURIAS TFNO 985319171 FAX 985346795 EMAIL amv amvelectronica com www amvelectronica com C FC ELECTRONICA Contents Important Safety Instr ctiGIs isisceun e pex 2 1 1 General Safety ou oe oes bx pU aequa ax dodo dE qi RD pa pE aU EBENE 2 ES duo C 2 Introduction to Functional CharacteristiCS oooomcccccncnncconnnnoncnnnannnnnrnnnnnnrnnnnannanns 3 2 1 System A 3 2 2 Block DIO Mission EEES EEEE E Eae 4 2 3 Electrical uie 5 2 4 Mechanical Drawings rone cee 6 Installation and Maintemance ise ioncciciccseecescccdescaciasasesescdeiesdiecsecdeenaseerdeedecsiesetseniaeneee 7 3 1 ROR Pane ESEESE 7 S M Front no o 12 AS TITRE 12 So 12 4 1 Connecting the Input POWEL ene et oc eene ted xe aaa eu eu RE dae Re PEERS dant 12 4 2 Connecting the LoS m 12 4 3 Invener Oper dos 13 4 4 Protection Features sia 13 Front LCD Panel Display and Set p Ye en pERR A 13 5 1 LOD Panel 13 5 2 Startup Sequence and Standby Status
12. Exacting OFF LINE See details in Section 5 3 Normal Haphazard The transfer relay will switch ON or OFF based on conformance to the Phase and Sync Frequency window that has been set Function Code 13 The transfer relay will be ON if AC input Grid power is available The DC AC inverter will remain synchronized and Phase with the incoming AC power Grid The relay will NOT switch off if the grid frequency is beyond the range set under Sync Frequency window Function Code 13 The transfer relay will switch ON or OFF Conformance to phase and frequency synchronization will not be considered ON LINE See details in Section 5 3 Frequency Synchronous DC AC inverter F AC input GRID I I l I Phase Synchronous Phase DC AC inverter Phase AC input GRID 20 rt AMV OND1000 X C1 15 Overload Alarm Sets the overload alarm When the output power is higher than the set value the unit will sound beep to remind that the unit is going to shutdown At the same time the internal Dry Contact Relay will open close See details in Section 3 1 6 Default 100 Setting range 5096 11096 6 RS 232 Communication and Operation 6 1 Operation of RS 232 Serial Port 6 1 1 This unit uses a standard 9 Pole D connector and three of the RS232 signal lines N C 3 DSR 6 ts 8 Nc
13. LCD screen for the user to set functions Function Enter Confirms a selection or value 5 1 4 LCD Display Displays inverter s operational status 5 2 Startup Sequence and Standby Status 5 2 1 Once turn on the inverter The display shows SR 1000 INVERTER INITIALIATION then checks the inverter Status flow is as follows E we AMV OND1000 X C1 NE INITIALIATION FAILURE or nes ALARM Vi ZXX X Vi XX X UVP Shutdown OK FQ XX X lo X X OR 1Sec 32 Vi XX X Vi XX X Vo XXX PARETS OVP Shutdown FQ XX X lo XX Alert OR Undervoltage Vi XX X OR OTP Shutdown Ale E Vi XX X OR OLP Shutdown Alert Fan Failure 5 3 Setup Menu Operation and Instructions Entering Setup Menu ni Press C2 Button longer than 2 seconds The inverter enters the Setup Menus consisting of three layers 1 Select Menu Heading 2 Select Menu Item 3 Setting Value AM AMV OND1000 X C1 ELECTRONICA Vi zXX X FQ XX X lo X X Select Select Menu Select Menu y Select Menu 5 Select Menu RST to default Menu User interface Parameter O P Parameter Main Menu Function Code o gt gt o gt a gt a ot ale 21 st 5 5 5 a all 5 amp S sl a ls stl all ati si 31 31 si ell 5 Select at at Jeo 3 9 18 1 5 Fes lea gl 9 q i E E g le le E EmLiEG c EC lal EX LI EL Li EX IES En lade SLE 2 c Item somscrisarissPise
14. V ELECTRONICA SALEN DE NUESTROS TALLERES AJUSTADOS NUMERADOS Y CON DOCUMENTACI N T CNICA SIENDO LA GARANTIA TOTAL DE 2 A OS LA GARANT A CUBRE LAS SITUACIONES DE DA O INTRINSECO Y NO LAS PROVOCADAS POR CAUSAS EXTERNAS O LA MANIPULACION POR PARTE DEL USUARIO LA GARANT A SE ENTIENDE EN NUESTROS TALLERES SIENDO POR CUENTA DEL USUARIO LOS COSTES DEL TRANSPORTE AMV ELECTRONICA
15. WARNING Do not open or disassemble the inverter Attempting to service the unit may cause risk of electrical shock or fire Problems and Symptoms Possible Cause Solutions No AC Power Output a LCD Panel Display Short circuit wiring Check AC wiring for OLP Shutdown error over loading short circuit Reduce load 26 ELECTRONICA b LCD Panel Display OVP Shutdown C LCD Panel Display UVP Shutdown d LCD Panel Display OTP shutdown Over input voltage OVP Low input voltage UVP Thermal shutdown OTP AMV OND1000 X C1 Check input voltage Reduce input voltage Recharge battery Check connections and cables Improve ventilation Make sure ventilation grilles slots of the inverter are not obstructed Lower ambient temperature 27 ELECTRONICA DIRECCI N Y TELEFONOS DE CONTACTOS AMV ELECTRONICA SL C NAVA N 7 BAJO 33207 GIJON ASTURIAS ESPANA FAX 00 34 985346795 PAGINA WEB www amvelectronica com TELEFONOS EMAIL DE CONTACTO DEPARTAMENTO RESPONSABLE TELEFONO e MAIL Comercial y Ventas Gracia Nomparte 985319171 Ext 10 gracia amvelectronica com Shara aeo Alejandro Arce 985319171 Ext 17 sat amvelectronica com 985319171 Ext 12 administracion amvelectronica com C NAVA N 7 BAJO 33207 GIJ ON ASTURI AS TFNO 985 319171 FAX 985 346795 Email amv amvelectronica com ELECTRONICA www amvelectronica com GARANTIA TODOS LOS EQUIPOS FABRICADOS POR AM
16. ature range of 0 C to 50 C or else the output efficiency may be affected Air flow to the inverter must not be restricted 2 Functional Characteristics Introduction 2 1 System The unit is a highly reliable DC AC inverter system designed with advanced power electronic and microprocessor technology offering the following features ll The inverter is equipped with a self diagnosis microprocessor that is able to identify and show all failure messages on the LED LCD display with associated visual audio alarms 1U height x 19 width x 13 6 depth 19 rack mountable Pure sine wave output THD lt 2 to operate higher end electronic equipment Built in 12A rated transfer switch Speeds up transfer time as a result of synchronized operation with the AC source at all times that allows the transfer to be interruption free for sensitive equipment Intelligent software for power management Hard wire and Dual AC outlets connection model option Loading and temperature controlled cooling fan Fan aging failure disconnection and blockage alarm Selectable Bypass Inverter modes Local and remote management and control RS 232 communication AMV OND1000 X C1 ELECTRONICA l Dry contact terminal M Efficiency 29056 Full linear load at 220VAC Output Advanced Protection Features Input over under voltage protection Internal over temperature protection Input reverse polarity protection Fuse Output overload
17. cuit In case there is a short circuit in the cable run between the batteries and the input terminals of the inverter it will result in overheating melting of the cables and consequent risk of fire and injury To prevent possibility of this hazard use Very Fast Acting DC Fuse in line with the positive cable The fuse should be as close to the positive battery terminal as possible Use Bussmann ANN series fuses will also require Fuse Block 4164 or equivalent The following sizes of cables and fuses are recommended for up to 6 ft distance between the batteries and the inverter Applies to both 120 VAC and 230 VAC versions 80A Connect DC input terminals to 24V 48V battery or other DC power source is positive is negative Reverse polarity connection can blow the internal fuse and may damage the inverter permanently WARNING Make sure that all the DC connections are tight torque to 9 10 ft lbs 11 7 13 Nm Loose connections could result in overheating and can be a potential hazard 10 NAV ELECTRONICA AMV OND1000 X C1 PVC WIRE AWG 4 6 WARNING The recommended inline fuse should be installed as close to the battery positive terminal as possible Failure to use a fuse on the cable running Between the inverter and battery may cause damage to the cable inverter and will void warranty NEGATIVE A ELECTRONICA AMV OND1000 X C1 3 2 Front Panel FRONT PANEL VIEW
18. ecom use a GFCI has not been provided The inverter incorporates standard AC short circuit protection 1 1 4 The following precautions should be taken when working on the inverter Remove watches rings or other metal objects ll Use tools with insulated handles ll Wear rubber gloves and boots 1 2 Other Safety Notes 1 2 1 Upon receipt examine the shipment box for damage Notify the carrier immediately before opening if damage is evident 1 2 2 Do not operate near water or in excessive humidity 1 2 3 Do not open or disassemble the inverter warranty may be voided 1 2 4 The DC side connections should be firm and tight 1 2 5 Grounding Reliable grounding of rack mounted equipment should be maintained 1 2 6 Do not drop a metal tool on the battery The resulting spark or short circuit on the battery or on the other electrical part may cause an explosion ELECTRONICA AMV OND1000 X C1 1 2 7 Install the inverter in a well ventilated area Do not block the front air vents or the rear air exhausts of the unit 1 2 8 Wiring Adequate input power must be supplied to the inverter for proper use correct wiring sizes must be ensured 2 9 Mount the inverter such that the fan axis is horizontal 2 10 Do not operate the inverter close to combustible gas or open fire 2 11 Do not operate appliances that may feed power back into the inverter 2 12 Temperature The inverter should be operated in an ambient temper
19. ils in Section 3 1 6 Default Alert SHDN Setting Range Disable Shutdown Alert Alert SHDN STATUS MENU FAN Fail or UV Alarm or Overload Alarm Shutdown OVP or UVP or OLP or OTP Disable 5 3 2 I P Parameter Select Menu 6 OVP Setting Sets the Over Voltage Protection OVP and shutdown Default 32 VDC for 24 V Model 64 VDC for 48 V Model Model SETTING VALUE RANGE 30 VDC 34 VDC 60 VDC 68 VDC 7 OVP Recovery When the DC input voltage is higher than the OVP setting the inverter shuts down Once the input voltage falls below the set OVP value the inverter will automatically restart Default 30 VDC for 24 V Model 60 VDC for 48 V Model Model SETTING VALUE RANGE 8 UVP Setting Setting the inverter s Under Voltage Protection UVP and Shutdown Default 20 VDC for 24 V Model 40 VDC for 48 V Model Model SETTING VALUE RANGE 9 UVP Recovery When the DC input voltage is below the set UVP value the inverter shuts down Once the input voltage rises above the set UVP value the inverter will automatically restart Default 25 VDC for 24 V Model 50 VDC for 48 V Model 18 ELECTRONICA AMV OND1000 X C1 SETTING VALUE RANGE 23 VDC 27 VDC 24V 46 VDC 54 VDC 48 V 10 UV Alarm Sets Under Voltage UV alarm When the input voltage is lower than the set value the unit will sound beep to remind that the unit is going to shutdown At the meantime the contact in the internal Dry
20. ings Inverter Ordering Information Model Input Output Voltage Output Voltage Frequency Number Voltage Nominal Range Range 24 VDC 230VAC 200 240 VAC 47 63 Hz 48 VDC 230VAC 200 240 VAC 47 63 Hz ELECTRONICA AMV OND1000 X C1 3 Installation and Maintenance 3 1 Rear Panel REAR PANEL VIEW ra oe rar ery CHASSIS GROUND DC INPUT DC INPUT REMOTE DRY CONTACT AC DUTPUT AC INPUT AC INPUT NEGATIVECO PDSITIVECO CONTROL TERMINAL STANDARD FG DUTPUT RS 232 Socker HARD WIRE HARD VIRE BREAKER 3 1 1 AC Input Breaker The AC input circuit breaker protects the unit from overload When an overload condition occurs the circuit breaker trips and disconnects the AC grid power input To reset it push the circuit breaker button The cause of tripping should be ascertained and corrected before the unit is reset 3 1 2 Hard wire Installation AC wiring connections l8 AC input and AC output terminal TRANSFER RELAY o INVERTER L O INVERTER N AC INPUT BREAKER LA TLO TL PENI IFN M 4 IK ZB CONNECTOR A Ep AC INPUT N GRID Mm AC INPUT L ll Connect AC output and AC input wiring to the Inverter terminals Please use the following information as your reference AC DUTPUT L LOAD AC DUTPUT N AM AMV OND1000 X C1 ELECTRONICA gauge m Line L Black 120 VAC Brown 230 VAC OUTPUT Neutral N White 120 VAC Blue 230 V
21. ous ACmptON ORANGE ACinutOFF OFF O Note Synchronous means that the grid AC input frequency and DC AC inverter output frequency or phase are the same See details in Section 5 3 3 6 INVERTER Displays DC AC inverter status PowerOKk GREEN Powernotgood RED BYPASS Displays Transfer Switch status BYPASS LED Status AC OUTPUT LOAD From DC AC inverter ORANGE AC INPUT Onine one DC AC Inverter From AC input bypass GREEN AC INPUT DC AC Inverter ALARM Displays status of the Failure Alarm Over Under Alarm FAN Alarm Set alarm in the inverter to operate normally NOTE For instructions on setting the alarm see details in Section 5 3 5 1 3 LCD Display Selection Buttons ELECTRONICA AMV OND1000 X C1 Function of Various Keys C2 Function Up You can use the up button to scroll through the menus or to select the value for set up under setting mode Function lt Down gt You can use the Down button to scroll through the menus or to select the value for set up under setting mode Bg Function Page Up gt You can use the Page Up button to scroll through the menus E CO Function Page Down You can use the Page Down button to scroll through the menus Function Enter Setup Menu Press the button longer than 2 seconds The inverter will change to Setup Menu Mode which appears on the
22. protection Output short circuit protection AC input short circuit protection Breaker 6 Amp or 12 Amp 2 2 Block Diagram AG GRID FILTER INPUT BYPASS RELAY DC AC FILTER INPUT OUTNPUT The inverter features IGBT technology which minimizes weight and dimension while enhancing output short circuit reliability and overload capacity AC output voltage is provided in one of the two following modes 1 From DC to AC Inverter Mode On line Mode 2 From AC Input Bypass Mode Off line Mode Either mode is front panel programmable In the first option Off line mode AC output power will be supplied through the AC bypass mode in its normal operation Upon AC input failure output power will be diverted through the DC to AC Inverter Mode Once AC mains are restored the unit will revert from the Inverter Mode to the Bypass Mode In the second option On line mode AC output power will be provided directly by the inverter from the DC source Should the DC source or inverter fail the system will transfer its output power through the bypass mode Once the DC power source is restored the system will revert to the inverter mode Electrical Performance ELECTRONICA AMV OND1000 24 C1 AMV OND1000 48 C1 Input Voltage Characteristics Over Voltage 30 34 VDC 60 68 VDC Protection Input Under Voltage 18 22 VDC 36 44 VDC Protection Voltage Range 18 34 VDC 36 68 VDC Continuous Output Power 1000W Maximum output Power 1150 W
23. u have to reset the unit after adjustment to activate the new setting 6 3 Example of the RS232 Operation 6 3 1 RS232 command Command format This unit uses high level language commands with a CR ODH and LF OAH as the end of the command The system would interpret and execute the command only after these two characters are received After the unit execute the command it would send a response string to the computer The response string is as follows gt CR LF Command executed successfully gt CR LF Command error not accepted gt CR LF Command correct but execution error e g parameters out of range If the command needs any information from the unit the unit would send the information back to the computer with CR and LF and then send the response string to the computer 22 ELECTRONICA AMV OND1000 X C1 6 3 2 Command format This unit supports the following command format There should always be a CR ODH and a LF OAH appended to the command while sending the command to this unit 1 Command to switch the Power ON OFF Format Power lt value gt Example A space ASCII code 20H is needed between Power and value value can be one of the following 0 Power off 1 Power on 2 Command to query the Output Frequency Format FRQ After Enter the unit s Output Frequency appears on the PC screen 3 Command to query the Output Voltage Format VOL After Enter the unit s
24. ud rate Setting Menu SETT value 0 120 RS 232 Baud 314 FUNC 3 Buzzer Setting Setting Menu SETT value Buzzer Beep sound 0 Disable 1 Shutdown 3 Aet Buzzer Setting 4 Message 5 Message SHDN 6 Message Alert 24 ELECTRONICA AMV OND1000 X C1 FUNC 4 Alert Setting Setting Menu SETT value Alert 0 Disable a Alert Setting 3 aet Alert SHDW FUNC 6 OVP Setting SETT value Model AMV OND1000 24 C1 OVP Setting AMV OND1000 48 C1 FUNC 7 OVP Recovery Setting Menu SETT lt value gt Model AMV OND1000 24 C1 OVP Recovery UVP Setting FUNC 9 UVP Recovery SETT lt value gt Model OND1000 24 C1 UVP Recovery AMV OND1000 48 C1 FUNC 10 UV Alarm Setting Menu SETT value Model AMV OND1000 24 C1 UV Alert 25 AMV OND1000 X C1 ELECTRONICA 194 246 OND1000 48 C1 Voltage AMV 000 4 FUNC 12 O P Frequency Setting Menu SETT lt value gt O P Frequency 47 63 FUNC 13 Sync Frequency Setting Menu SETT value FUNC 14 Bypass Relay Setting Menu SETT lt value gt MODE ONLINE ON LINE 0 Haphazard OFF LINE Bypass Relay Normal OFF LINE Exacting OFF LINE FUNC 15 Overload Alarm Setting Menu SETT value Overload Alarm 50 110 7 Information 7 1 Troubleshooting