Home

iC5 catalogue 2015.04 ENG

image

Contents

1. Program parameters 44 MM Parameter group There are 4 parameter groups to set parameters properly for the operation Group Description Drive group Basic parameters such as Command frequency Accel Decel time etc Function 1 group Basic functional parameters such as Mox frequency Torque boost etc Function 2 group Application parameters such as Frequency jump Max Min of limit of frequency etc Input Output group Parameters to construct the sequence such as Multifunction terminal setting Auto operation etc W Parameter group navigation Drive group Basic operation parameters such as Command frequency Accel Decel time etc Function 1 group Basic functional parameters for adjusting Output frequency Voltage etc Function 2 group Application parameters of PID operation The 2nd motor setting etc Input Output group Parameters to construct the sequence such as Multi function terminal setting etc e Shifting between groups is possible only in the first code of each group Shift by using Right shift key gt Shift by using Left shift key 4 1 1 1 The value of the Command frequency will be displayed in the first code of the Drive group It will show the value set by the operator The factory set value is 0 0 Nole ll Parameter navigation in Drive group Sum mn ot 2 E Procedure to set command frequency in Drive group To input new command frequen
2. Fax 86 28 8670 3203 e LSIS ShenYang Office China Room 803 Hongyuan Building 52 South Nanjing Road Heping District Shenyang P R China Tel 86 24 2321 9050 Fax 86 24 8386 7210 e SIS Jinan Office China Room 317 Chuangzhan Center No 201 Shanda Road Lixia District Jinan Shandong P R China Tel 86 531 8699 7826 Fax 86 531 8697 7628 e LSIS Co Ltd Tokyo Office Japan Tokyo Club Building 13F 2 6 Kasumigaseki 3 chome Chiyoda ku Tokyo 100 0013 Tel 81 3 6268 8241 Fax 81 3 6268 8240 e LSIS Co Ltd Rep Office Vietnam Gema Dept Tower 18F 6 Le Thanh Ton District 1 HCM Vietnam Tel 84 8 3823 7890 e LSIS Detroit Office U S A 5700 Crooks Rd Suite 211 Troy MI 48098 USA Tel 1 248 792 2637 8 Fax 1 248 792 2642 e LSIS Co Ltd India Office India 109 First Floor Park Central Sector 30 Gurgaon 122 002 Haryana India Tel 91 1244 930 077 Fax 91 1244 930 066 e SIS Moscow Office Russia 123610 Krasnopresnenskaya nab 12 building 1 office Ne1005 Moscow Russia Tel 7 495 258 1466 1467 Fax 7 495 258 1466 1467 e LSIS U K Office United Kingdom G17 Bedford Lab Stannard Way Priory Business Park Bedford MK44 3RZ U K Tel 44 012 3483 4774 Fax 44 012 3483 4775 Starvert iC5 E 2003 2 23 2015 04 Printed in Korea Pacomkorea
3. adjustment Energy save Electronic thermal selection Electronic thermal level 1 min Electronic thermal level continuous Motor cooling system Overload alarm level Overload alarm hold time Overload trip selection Overload trip level Overload trip delay time Stall prevention mode selection Stall prevention level Jump to desired code Previous fault history 1 Previous fault history 2 Previous fault history 3 Previous fault history 4 Previous fault history 5 Delete fault history Dwell frequency Dwell time Selection of jump frequency Jump frequency 1 low Jump frequency 1 high Jump frequency 2 low Jump frequency 2 high Jump frequency 3 low Jump frequency 3 high Inclination at the beginning of S curve Inclination at the end of S curve Output phase loss protection Power ON start selection Restart after fault reset Speed search selection Speed search curent limitation level Speed search P gain Speed search gain Number of auto restart attempt Delay time before auto restart Motor power rating selection Number of motor poles Rated motor slip Rated motor current in RMS No load motor current in RMS Motor efficiency Setting range O to F33 Hz Oto 100 F31 to F35 Hz Oto 100 F33 to F37 Hz Oto 100 F35 to Maximum frequency Hz Oto 100 40 0 to 110 0 Oto 30 O No 1 Yes F52 to 200 50 to F51 76 O self cool 1 forced cool 30 to 150 76 Oto 30 sec O No
4. 1 Yes 30 to 200 76 Oto 60 sec 000 to 111 bit set Bit O During accel Bit 1 During steady speed Bit 2 During decel 30 to 150 76 11095 O No 1 Yes 0 to Max frequency Hz O to lO sec O No 1 Yes O to H12 Hz H11 to Maximum frequency Hz O to H14 Hz H13 to Maximum frequency Hz O to HI Hz H15 to Maximum frequency Hz 1 to 100 1 to 100 O No 1 Yes O No 1 Yes O No 1 Yes 0000 to 1111 bit set Bit O During accel Bit 1 After fault reset Bit 2 Restarted after instant power failure Bit 3 When H20 is set to I Yes 8 to 200 O to 7777 O to 9999 Oto 10 O to 60 sec 02075 3 224 2to 12 O to 10 HZ O to 20 A 0 1 to 20 A 70 to 100 12 Factory default 15 25 30 50 45 79 60 100 100 0 0 150 100 0 150 10 180 60 000 100 100 1000 EX X os X Adjustable during run No No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes Yes NO NO NO NO NO NO NO NO NO NO NO Yes Yes Yes NO Yes Yes Yes Yes Yes NO NO NO NO NO NO Program parameters descriptions FU2 Keypad group display H37 H39 H40 H41 H42 H44 H45 H46 H50 H51 H52 H53 H54 H55 H70 H71 H72 H73 H74 H79 H81 H82 H83 H84 H85 H86 H87 H88 H89 H90 H93 H94 H95 Description Load inertia Carrier frequency C
5. 8 B 0 4 0 75KW N WARNING W Risk of Injury or Electric Shock Resd the manual and follow the safety ion bef E W Risk of Electric Shock efore opening the cover disconnect ower and wait at least 10minutes W Risk of Electric Shock Securely ground earth the invel LS 135 9 67 5 Applied drives W H D W kg SV004iC5 1 79 143 143 0 87 SVOO4iC5 1F 79 143 143 0 95 SVOO8iC5 1 79 143 143 0 89 SVOOSiC5 1F 79 143 143 0 97 SV004iC5 2 79 143 143 0 89 SV008iC5 2 79 143 143 0 89 19 B 15 22kW X STOP RST N WARNING W Risk of Injury or Electric Shock Resd the manual and follow the he safety instruction before use W Risk of Electric Shock Before opening the cover disconnec all power and wait at least 10minutes W Risk of Electric Shock Securely ground earth the inverter LS 138 Applied drives W H D W kg SV015iC5 1 156 143 143 1 79 SVO15iC5 1F 156 143 143 1 94 SV022iC5 1 156 143 143 1 85 V022iC5 1F 156 143 143 2 20 21 Safety Instructions LSIS Co Ltd E HEAD OFFICE LS Tower 127 LS ro Dongan g
6. E SPEED DRIVE AND MOTOR to absorb the voltage peaks in the motor terminals when the connection cables are long or there are more than one motor in parallel for having a better efficiency and to eliminate the humming noise of the motor d RN y Pr The family of filters manufactured by LIFASA has been a specially developed and approved for its application gt with variable speed drives to assure the compliance of the EMC Electro Magnetic Compatibility and the LV safety European Directives in both industrial and be domestic environments Powers from 0 37 to 375 kW Single three phase voltages 220 230 Vac Three phase voltages 380 460 Vac Sensorless vector control V F closed loop Removable console with copy function R 485 communication facilities as standard Autotuning Special parameters for special applications The commutation of the IGBT s at high frequency PWM provokes an output voltage with peaks up to 1300 V The LC filler low pass reduce the dV dt converting the vollage in a sinus waveform eliminating all the isolation problems in the motor and the emission of interference from the cables Filter for use of LS Drives Vector Motor Control Ib erica VMC V C Mar del Carib 10 Pol Ind La Torre del Rector 08130 Santa Perp etua de Mogoda Barcelona SPAIN vector motor control Tel 34 935 748 206 Fax 34 935 748 248 e mail info vmc es www vmc es 1
7. ON car i i i diis Siet Urste husu alis N Warning To restart the drive make BX terminal OFF during the FX RX is ON GEA A contact fault signal input If 120 21 22 23 24 set to 18is ON the drive output is interrupted HEb B contact fault signal input If 120 21 22 23 24 set to 19 is ON the drive output isinterrupted If signal input is failed for the driving by using analog input or option RS485 try to drive according to OOE Frequency command loss r un an e de S the setting at 162 Fault Error MIN HEE Overcurrent GFE Ground fault In UL Drive overload ri L LILI Overload trip Tue Late Cooling fan overheat Dr LUL Output phase loss Lr PEN Coolingfan error ri Li ut Overvollage 1 I L LIL Undervoltage DLU EEH Electronic thermal LLO GEH A contact fault signal input SEB B contact fault signal input 1 D O LI Frequency command loss ona Lii Parameter store error LI IL moo Output instant interrupting Err Communication error Possibsle cause A e Accel Decel time is not enough for the load inertia 6D Increase the Accel Decel time e The load is greater than the rating of the drive e Drive output is assigned during the free run of the motor e The motor brake operates too fast e Ground fault at the load side of the drive e Insulation of the motor is broken e The load is greater than the rating of the drive e Power rating is set to the lower valu
8. RQUE 200 300 300 a 100 0 o 1 7 o T anno 0 100 180 _200 anno OL 300 600_900_ 1200 1500 1800 2100 2400 2700 3000 3300 100 190 3 100 SPEED rpm SPEED rpm The auto tuning algorithm in the iC5 sets the motor factors automatically that brings the traditional commissioning difficulties mainly in low speed by the load variation and the low torque generation to a settlement e Difficulty of measuring the motor constant Input errors by an user Low torque in low speed Low speed by the load variation Setup by an expert The iC5 provides PNP and NPN signals for outside controllers It works with 24Vdc regardless of the type of PLC or control signals The iC5 provides the most popular communication interface ModBus RTU for remote control by PLC or other devices 2 Programmable PID PID process control is used in iC5 to make speed corrections quickly with a minimal amount of overshoot and oscillation for the control of flow temperature pressure and etc orque in low speed Optimized motor control plicable motor Us A Be AA ie orn AI eee en EMI filter optional Input voltage foos fics 1 Er LS Starvert drive Motor rating 004 0 4kW 022 2 2kW Name of Series SV004iC5 1 Model no of LS Starvert drive INPUT 200 230V Iphase 55A 50 60H
9. ction function activates Recent 5 faults records stored Forced air cooling Open Pollution degree 2 MONG 5010 20C 65C Less than 90 no condensation 1 000m above sea level Max 5 2m sec 0 6G Protected from corrosive gas combustible gas oil mist or dust short circuit link reserved for DC reactor P P1 N MCCB AC input OJO L1 Single phase 200 230V L2 G KNOB Ground Multi function input terminals P1 to P5 o Analog output JD U P1 factory set Forward 0 10V OO P2 factory set Reverse JQ OO P3 factory set Emergency stop Multi function Input terminal OO C P4 factory set RST cm O one e P5 factory set JOG E Multi function relay 30B 30C o_o VR Power for speed signal 12V 10mA MO Multi function open collector output terminal EXTG VI Speed signal input 0 10V Speed signal input 0 20mA CM Common Note 1 Main circuit terminal Control circuit terminal 2 Analog output voltage is adjustable upto 12V 3 Speed command can be set by Voltage Current Voltage Current Keypad Keypad knob Voltage and Keypad knobtcurrent Terminal Signal Description L1 L2 AC line input Single phase AC line input U V W Drive output 3 phase output terminals to motor P P1 DC reactor Connecting DC reactor G Ground Chassis ground SV004iC5 1 SVO08 C5 1 SVO15iC5 1 Input wire size 2mm 2mm 3 5mm Output wire 2mm 2mm 3 5mm Ground wire 2mm 2mm 3 5m
10. cy 30 05 Hz from 0 0 set in the factory vid The first code 0 0 displayed LI LI Press pro ent e key 1 The digit of the first decimal place can be changed LI Press right gt key 1 The digit of the second decimal place can be changed LI Press up A key until the digit becomes 5 5 Press left 4 key r1 The left digit can be set LI Press lefi 4 key fl Press left 4 key r1 e Though 00 0 is displayed the actual value remains at 0 05 LI Make 3 by pressing up A key Press pro eni e key e 30 0 is flickering m Press pro eni e key to stop the flickering fi pl e Command frequency 30 0 is stored 1 The LCD on the keypad of Drive iC5 displays only 3 digits Use the shift keys 4 gt to monitor and set the parameters 2 To cancel the parameter setting press the shift keys lt or gt while 30 0 is flickering in the procedure no 8 10 a wy J ro E S l Le Ta ES hal The first code 0 0 displayed e Press up A key once to move to next code e The second code ACC appears e Press up A key once to move to next code The third code dEC is shown Press up A key to move to next code To move to the last code press up A key until drC appears e Press up A key once more to return to the first code To move in reverse order use down Y key Drive group FUI group Program parameters descriptio
11. e than the load e Torque boost is too great e Foult in the cooling system e The cooling fan is used beyond the life expectancy e High ambient temperature e Fault in the load side contactor e Wiring problem Alien substances are in the ventilator The cooling fan is used beyond the expectancy Decel time is not enough for the load inertia GD e There is a survived load in the load side e Higher voltage than rating is supplied e Lower voltage than rating is supplied e Power capacity is not enough for the additional loads like welders and direct on line starting motors e Fault in the line side contactor e Overtemperature of the motor e The load is greater than the rating of the drive e Electronic thermal level is set lower than rating e Drive power rating is set to the lower value than the load e Long operation at low speed e The terminal 20 21 22 23 24 set 1018 19 is ON e Frequency command loss at terminals V1 and e Refer to LS or distributors 17 Solution gt Replace the drive with a higher rating gt Operate after the motor stops or use speed search H22 in FU2 in the output terminals gt Verify the output wiring gt Verify the mechanical brake gt Check to see if there is something wrong with output wiring gt Replace a motor Increase the ratings of a motor and an drive gt Check to see if the setting is correct gt Reduce the torque boost gt Check to see
12. ec O to 600 sec 0 to 600 sec Factory default 10 0 0 0 10 60 0 10 0 0 0 10 60 10 4 0 20 60 0 0 O FX RX 2 EST 3 RST 4UOG On NBO anak BWW Adjustable during run Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Adjustable during run Yes Yes Yes Yes Yes Description Setting range Factory default 143 Deceleration time 5 O to 600 sec 144 Acceleration time 6 O to 600 sec 145 Deceleration time 6 O to 600 sec 146 Acceleration time 7 O to 600 sec 147 Deceleration time 7 O to 600 sec O Frequency Curent 2 Voltage 3 DC link voltage 151 AM output adjustment 100 to 200 100 Yes 152 Frequency detection level 0 to Max frequency Hz 30 Yes 153 Frequency detection bandwidth O to Max frequency Hz 10 Yes O FDT 1 1 FDT 2 2 FDT 3 3 FDT 4 A FDT 5 5 OL 6 IOL 7 Stall Definition of multifunction 8 OV output terminal MO 9 LV 10 OH 11 Lost command 12 Run 13 Stop 14 Steady 15 Search 16 Ready 17 Fault select 155 Definition of relay functions Same as above 154 17 Yes 000 to 111 bit set Fault relay setting Bit O Low voltage 30A 30B 30C Bit 1 Trip Bit 2 Number of auto retry 160 Drive number 1 to 32 Yes O 1200bps 1 2400bps 161 Baud rate 2 4800bps 3 Yes 3 9600bps 4 19200b
13. ee ee DEP DEP LN N I 1 fit Wh i JI MH REN HH ni Ii Hil Tu Wi NN li i In I x WH E 4 li TIT flak of Electric Shock Jm IIl li Bators opening the tower disconnect 1 Ji A el po are ee di naui 0 rursus HI I HI REF I i Wl I n Variable Frequency Drive IC5 0 4 2 2kW 0 5 3HP 1 Phase 200 230Volts IS A WARNING PEE Bf AAA m me uem ie tla da bie gn kem clem E dome er e GE ms eed duds ii n BIS mom Hm ef Piecing Brea Bara sham ruo hime eee DR AAA b TEE UP ap Gere HA Boe dd Deere Giro rana pr ara Ls Global standard 05 serves a wide variety of applications to meet the majority of user needs e Modbus communication Option e PID control e Sensorless vector control e Motor parameter auto tuning C Du 1509001 15014000 Models Wiring Keypad Program parameters descriptions Tips on Installation 05 07 08 11 18 pep 04 06 08 09 16 19 Features Specifications Terminal configuration Program Parameters Checking amp Troubleshooting Dimensions LS Drive iC5 Series Features w Sensorless vector The iC5 adopts sensorless vector control algorithm and it improves not only the torque control characteristics but the speed controlability in an uncertain condition caused by the load variation as well 300 300 200 ki 200 K 5 gt 100 0 TORQUE TO
14. equency Hz 0 to Mox frequency Hz 0 to Mox frequency Hz IA pm Mm F Forward R Reverse 1 to 60 O None 1 Forward disable 2 Reverse disable O Linear 1 S curve O Linear 1 S curve O Decel 1 Dc broke 2 Freedun F23 to 60 HZ Oto 60 sec Oto 200 Oto 60 sec Oto 200 Oto 60 sec Oto 60 sec Oto 400 Hz 40 to 400 Hz 30 to Mox frequency Hz Oto 10 Hz O No 1 Yes O to High limit Hz Low limit to Max frequency Hz O Manual 1 Auto 0 0 to 15 0 0 0 to 15 0 76 O Linear 1 Square 2 User V F 11 Factory default 0 00 8 10 10 00 20 00 30 00 T1 Adjustable during run Yes Yes Yes NO NO Yes Yes Yes pe Yes Yes Yes Yes Yes NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO Program parameters descriptions FUI group FU2 group Keypad display F31 F32 F33 F34 F35 F36 F37 F38 F39 F40 F50 F51 F52 F53 F54 F55 F56 F57 F58 F59 F60 HO H1 H2 H3 H4 H5 H H7 H8 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H20 H21 H22 H23 H24 H25 H26 H27 H30 H31 H32 H33 H34 H36 Description User V F frequency 1 User V F voltage 1 User V F frequency 2 User V F voltage 2 User V F frequency 3 User V F voltage 3 User V F frequency 4 User V F voltage 4 Output voltage
15. ications in this catalog are subject to change without notice due to continuous product development and improvement 2015 04 2003 2 LSIS Co Ltd All rights reserved Aururna SMART ENERGY For your safety please read user s manual thoroughly before operating Contact the nearest authorized service facility for examination repair or adjustment Please contact a qualified service technician when you need maintenance Do not disassemble or repair by yourself Any maintenance and inspection shall be performed by the personnel having expertise concerned wwwW lsis com Overseas Branches e LSIS Shanghai Office China 32nd Floor International Corporate City No 3000 NorthZhongshan Road Putuo District Shanghai China 200063 Tel 86 21 5237 9977 Fax 86 21 5237 7189 LSIS Beijing Office China Room 2306 Building B Landgent Center No 24 Middle Road East 3rd Ring Road Chaoyang District Beijing P R China Tel 86 10 5761 3127 Fax 86 10 5761 3128 e LSIS Guangzhou Office China Room 1818 1820 Xinyuan Building NO 898 Tianhe North Road Tianhe District Guangzhou P R China Tel 86 20 8326 6784 Fax 86 20 8326 6287 e LSIS Qingdao Office China Room 2001 Galaxy Building 29 ShanDong Road ShiNan District QingDao ShanDong P R China Tel 86 532 8501 6058 Fax 86 532 8501 6057 e LSIS Chengdu Office China Room1710 17 F Huamin Empire Plaza NO 1 Fuxin Road Chengdu P R China Tel 86 28 8670 3200
16. if there is any alien substance in the ventilation system gt Replace the cooling fan gt Keep the ambient temperature below 40 gt Replace the contactor Verify the output wirin gt Check to see if there is any alien substance in the ventilation system gt Replace the cooling fan gt Increase the Decel time gt Uase DB unit gt Verify the power voltage gt Verify the power voltage gt Increase the power capacity gt Replace the contactor gt Reduce the load or operation times gt Increase the ratings of the drive gt Adjust the electronic thermal properly gt Adjust the drive rating properly gt Replace the motor with the separated power cable for the cooling fan gt Verify the circuits connected to the external fault terminals Verify the wiring connected to V1 and terminals Tips on Installation lt lt Warning Carefully read the instruction for installation and wiring of drives and relevant devices Normal operation is impossible in case of the improper system design and wiring These can shorten the life of the drive and damage it at the worst INDUCTORS FOR VARIABLE SPEED DRIVES The inductors manufactured with special magneticcores are advisable for location BETWEEN MAINS AND VARIABLE SPEED DRIVE in order to protect the equipment from overvoltages voltage surges and also to limit the line current and the harmonics generated by VSD BETWEEN VARIBL
17. m Terminal Lug 2mm 3 59 2mn 3 52 3 9mm 3 59 Tightening Torque 9 Ib in 9 Ib in 15 Ib in Terminal P1 P2 P3 P4 P5 CM VR V1 AM MO EXTG P24 30A 30B 30C a Terminal Description Multi function input T M P1 P5 Common Terminal for P1 P5 AM P24 12V power supply for external potentiometer 0 10V Analog Voltage input 0 20mA Analog Current input Multi function Analog output Multi function open collector output T M Ground T M for MO 24V Power supply for P1 P5 Multi function relay A B contact output Multi function relay A B contact output 30A B Common Keypad FWD REV O PNP 2 4 v y lt Key RUN STOP RESET 4 Q STOP RST e 3 OPEET TAES A A KNOB Volume NPN PNP A Wire size 22 AWG 0 3mm 22 AWG 0 3mm 22 AWG 0 3mm 22 AWG 0 3mm 22 AWG 0 3mm 22 AWG 0 3mm 20 AWG 0 5mm 20 AWG 0 5mm 20 AWG 0 5mm 20 AWG 0 5mm 20 AWG 0 5mm 20 AWG 0 5mm Run key Stop Reset key Program Enter Frequency Selection Dc Torque Nm 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 Description To operate the drive SV022iC5 1 3 5mme 3 5mme 3 5mme 3 5mm 3 59 15 lo n LPS Note To stop operating or reset in case of fault To change parameters and save them To change the frequency Mode selection between NPN and PNP To increase the parameter values To decrease the parameter values To move the cursor left To move the cursor right
18. ng pin has been overheated due to high ambient temperature OHE Coolingpin overheat a eh rn iiis The drive output is interrupted COL DC link condenser overload If the DC condenser of Drive is in need of replacement the drive output is interrupted m One or more of output line U V and W lost II IT prem Output phase loss The drive output is interrupted OOO Dudes The drive main voltage has been risen above the permissible limit 400V iz 9 Checkif deceleration time has been set too short or line input voltage is too high bot Undervoltage The drive output is interupted a The drive output is interupted according to the set time inverse curve to prevent the ELH Electronic thermal E i 9 P overtemperature of the motor due to overloads eamm Error has been occured on fhe storing of the changed parameters cer Parameter store error ee It is displayed when power is on EXER It is displayed in case of software error ad Hardware error It is not possible to reset by STOP RST key on the keypad or reset terminals Open the drive power and make sure the keypad power is off and close the power again Communication error between coniroller and keypad Err Communication error It is not possible to reset by STOP RST key on the keypad or reset terminals Open the drive power and make sure the keypad power is off and close the power again FHn Coolingfan eror Error has been occured on the coolingfan The drive output is interupted in the case that BX terminal is
19. ns Keypad display 0 00 ACC DEC Drv Frq St St2 St3 Cur RPM DCL vOL POr tOr nOn drC FUI FU2 I O FO F3 F5 F F7 F8 F9 F10 F11 F12 F13 F14 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 Description Output frequency during run Reference frequency during stop Acceleration time Deceleration time Drive mode Frequency mode Step frequency 1 Step frequency 2 Step frequency 3 Output current Motor speed DC voltage User display selection Fault display Motor direction set Function Group 1 selection Function Group 2 selection I O Group selection Jump to desired code Run prevention Acceleration pattern Deceleration pattern Stop mode DC injection braking frequency DC injection braking ON delay DC injection braking voltage DC injection braking time Starting DC injection braking voltage Starting DC injection braking time Motor exciting time Jog frequency Maximum frequency Base frequency Starting frequency Frequency limit selection Frequency limit high Frequency limit low Manual Auto torque boost selection Torque boost in forward direction Torque boost in reverse direction Volts Hz pattern Setting range 0 to Max frequency Hz O to 6000 sec O to 6000 sec O Keypad 1 Fx Rx 1 2 Fx Rx 2 3 ModBus O Keypaa 1 1 Keypad 2 2 Volume 3 V1 AI o Volume 1 6 V 1 7 Volume V 1 8 ModBus 0 to Mox fr
20. ontrol mode selection Auto tuning Stator reristance Leakage inductance Sensorless P gain Sensorless gain PID feedback signal selection P gain for PID control gain for PID control D gain for PID control F gain for PID control Limit frequency for PID control Reference frequency for Accel Decel Accel Decel time scale Power On display User display selection Gain for motor speed display Software version 2nd acceleration fime 2nd deceleration time 2nd acceleration time 2nd V F pattem 2nd forward torque boost 2nd reverse torque boost 2nd stall prevention level 2nd electronic thermal level 1 min Setting range Oto 2 to 15 kHz O V F 1 Slip compen 2 PID 3 Sensorless vector control 010 Oto 5 BY 0 to 300 mH 0 to 32767 0 to 32767 O l V1 0 to 999 9 76 0 1 to 320 sec 0 1 to 30 0 sec Oto 999 9 76 0 to Mox frequency Hz O Max freq 1 Delta freq 0 0 001sec 1 0 01sec 2 Isec O Command frequency 1 Accel Time 2 Decel Time 3 Drive mode A Frequency mode 5 Step frequency 1 6 Step frequency 2 7 Step frequency 3 8 Current 9 Speed 10 DC link voltage 11 User display 12 Fault display 13 Motor direction O Voltage 1 Watt 2 Torque 1 to 1000 XXX O to 6000 sec O to 6000 sec 30 to Mox frequency Hz O Linear 1 Square 2 User V F 0 0 to 15 0 76 0 0 to 15 0 76 30 to 150 H89 to 200 2nd elect
21. ps O None 162 Operating selection at loss of freq reference 1 Free run 0 Yes 2 Stop 163 Waiting time after loss of freq reference 0 1 to 12 sec 1 0 Yes sO SO CO COO N 150 AM output 0 Yes 154 12 Yes 156 010 Yes pm Peripheral Device LL MCCB Molded Case Circuit Breaker and MC Magnetic Contactor Voltage Capacity Circuit Breaker MCCB Leakage Breaker ELCB Magnetic Contactor MC kW Moda Rated Current A Model Rated Model Rated Model Rated on MC 6a i I 9a MC4b UTE100 gt ERG is MC 180 MC 18 18 MC22 22 04 Ts t5 MC 6a 15 1 Phase 200V ABS33C gt Checking amp Troubleshooting 2 If protection function activates due to error fault in the drive corresponding alarm is displayed on the keypad as shown below Correct the error fault before restarting or it may decrease the drive s life expectancy Display Fault Error Description HL LE Overcurrent Output current has been greater than 200 of the rated current The drive output is interupted LEE Ground fault Ground fault has been occured at the load side of the drive The drive output is interrupted ieu Output current greater than 150 of the rated current has been flowed over 1 min I ote Drive overload ae The drive output is interrupted Output current has been greater than the set value F57 of the rated current OLE Overload trip iode s 5 Nosti i The drive output is interrupted a mU Cooli
22. put terminal P2 Definition of multifunction input terminal P3 Definition of multifunction input terminal P4 Definition of multifunction input terminal P5 Terminal input status Terminal output status Filtering time constant for multifunction input terminal Step frequency 4 Step frequency 5 Step frequency 6 Step frequency 7 Acceleration time 1 Deceleration time 1 Acceleration time 2 Deceleration time 2 Acceleration time 3 Deceleration time 3 Acceleration time 4 Deceleration time 4 Acceleration time 5 14 Setting range Oto 63 0 to 9 999 msec Oto 10V O to 400 Hz Oto 10V 0 to 400 Hz 0 to 9 999 msec Oto 10V 0 to Max frequency Hz Oto 10V 0 to Max frequency Hz 0 to 9 999 msec O to 20 mA 0 to Mox frequency Hz 112 to 20 mA 0 to Max frequency Hz O None 1 Half of x1 2 Below x1 O FX 1 RX 2 BX 3 RST 4 JOG 5 Speed L 6 Speed M 7 Speed H 8 XCEL L 9 XCEL M 10 XCEL H 11 DC Brake 12 2nd function 15 Up 16 Down 17 3 wire 18 EXT A 19 EXT B 21 Open loop 22 Main drive 23 Analog hold 24 XCEL stop Same as above 20 Same as above 120 Same as above 120 Same as above 20 00000 11111 bit 00 11 bit 0 to Max frequency Hz 0 to Max frequency Hz 0 to Max frequency Hz 0 to Max frequency Hz 0 to Max frequency Hz 0 to 600 sec O to 600 sec 0 to 600 sec O to 600 sec 0 to 600 sec O to 600 sec O to 600 s
23. ronic thermal level continuous 50 to H88 2nd motor rated current Parameter initializing Parameter writing protection Parameter change protection 0 1 to 20 A O No 1 All groups 2 Drive 3 Function 1 A Function 2 5 1 0 O to FFF O to FFF 13 Factory default 0 30 XXX 10 60 150 150 100 Adjustable during run No Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes No No No No No Yes Yes No No Yes Yes Program parameters descriptions I O group Keypad display 10 1 12 I3 14 15 16 17 18 19 110 111 112 13 114 115 116 120 121 123 124 125 126 127 130 181 132 133 134 135 136 137 138 139 140 141 142 Description Jump to desired code Filtering time constant for VO signal input VO input minimum voltage Frequency corresponding to 12 VO input maximum voltage Frequency corresponding to 14 Filtering time constant for V1 signal input V1 input minimum voltage Frequency corresponding to 17 V1 input maximum voltage Frequency corresponding to 19 Filtering time constant for signal input linput minimum current Frequency corresponding to 112 input maximum current Frequency corresponding to 114 Criteria for analog speed signal loss Definition of multifunction input terminal P18 9 15 20 21 22 23 24 25 26 reserved Definition of multifunction in
24. rse Setting up to 8 speeds use multi function terminal 0 1 6000 sec Max 8 types available by multi function terminal Selectable accel decel patterns Linear U and S Interrupting the output of the drive Jog operation Reset the fault when protective function is active Frequency detection Overload alarm Stalling Overvoltage Undervoltage Drive overheating Run Stop Constant speed Speed searching Fault output Relay and Open collector output Choose one from output frequency current voltage and DC voltage Output voltage 0 10V DC braking Frequency limit Frequency jump Second function Slip compensation Reversing prevention Auto restart PID control Digital Keypad e Communication RS485 Drive trip Overvoltage Undervoltage Overcurrent Drive overtemperature Motor overtemperature I O phase loss I O mis wiring Overload External device fault 1 2 Loss of speed command Hardware fault Communication error CPU error Drive alarm Stall prevention Overload alarm Momentary Less than 15 msec keeping operation power less More than 15 msec auto restart available W Display keypad Operation information Trip information ll Environment Cooling method Degree of protection Ambient temperature Storage temperature Relative humidity Altitude Vibration Application site Output frequency current and voltage Set frequency value Operation speed DC voltage Display the trip cause when the prote
25. u Anyang si Gyeonggi do Korea a EMEA 82 2 2034 4901 bonseongk Isis com a Asia Pacific Americas 82 2 2034 4620 mswoo lsis com Overseas Subsidiaries e LSIS Dalian Co Ltd Dalian China No 15 Liaohexi 3 Road Economic and Technical Development Zone Dalian 116600 China Tel 86 411 8730 7510 Fax 86 411 8730 7560 e LSIS Wuxi Co Ltd Wuxi China No 1 Lexing Road Wuxi National High amp New Tech Industrial Development Area Wuxi214028 Jiangsu P T China Tel 86 510 8534 6666 8005 Fax 86 510 8534 4078 e LS Hukai Electric Hubei Co Ltd Hubei China No 100 Tanjiahe Road Dianjun District Yichang City Hubei Province 443004 China Tel 86 717 667 7339 Fax 86 717 667 7559 e LS VINA Industrial Systems Co Ltd _Hanoi Vietnam Nguyen Khe Dong Anh Hanoi Vietnam Tel 84 4 6275 8055 Fax 84 4 3882 0220 e LSIS ME FZE Dubai U A E LOB 19 205 JAFZA View Tower Jebel Ali Free Zone Dubai United Arab Emirates Tel 971 4 886 5360 Fax 971 4 886 5361 e LSIS Europe B V Netherlands 1st Floor Tupoleviaan 48 1119NZ Schiphol Rijk The Netherlands Tel 31 20 654 1420 Fax 31 20 654 1429 e LSIS Japan Co Ltd Tokyo Japan Tokyo Club Building 13F 2 6 Kasumigaseki 3 chome Chiyoda ku Tokyo 100 0013 Tel 81 3 6268 8241 Fax 81 3 6268 8240 e LSIS USA Inc _ Chicago U S A 2000 Millbrook Drive Lincolnshire Chicago IL 60069 United States Tel 847 941 8240 Fax 847 941 8259 Specif
26. z Input voltage current frequency and phase OUTPUT O INPUTV 3phase 2 5A 0 1 400Hz Output voltage current capacity FLA frequency and phase 0 5HP 0 4kW AA Barcode and Serial no 0010222100155 LS Industrial Systems Co Ltd Made in Korea Specifications gt Model Motor rating HP kW Output ratings FLA A Voltage Frequency Input ratings Voltage Frequency Current lll Control Control method Frequency setting resolution Frequency setting accuracy V F ratio Overload capacity Torque boost ll Operation Input signal Operator control Frequency setting Start signal Mulli step Mulli step accel decel time Emergency stop Jog Fault reset Output signal Operation status amp Fault output Indicator Operation function ll Protection functions W Specifications 200 230V class Capacity kVA SVOOAIC5 1 SVO008iC5 1 SVO15iC5 1 SV022iC5 1 0 5 2 3 0 4 0 75 1 5 22 0 95 1 3 45 25 5 8 12 Three phose 200 to 230V O to 400Hz Single phase 200 to 230V 1076 50 to 60Hz 5 5 5 2 2 16 21 6 V F control Sensorless vector control Digital reference 0 01Hz Analog reference 0 06Hz 60Hz Digital 0 01 of Maximum output frequency Analog 0 1 of Maximum output frequency Linear Squar pattem User V F Imin at 150 30sec at 20076 with inverse characteristic Manual 0 to 15 adjustable Auto Keypad Terminal Communications e Analog 0 10V 0 20mA Forward Reve

Download Pdf Manuals

image

Related Search

Related Contents

Accompagner les jeunes en difficulté de lecture pour prévenir l  Bedienungsanleitung MADIface XT  Cuisinart TCS-60C User's Manual  Please read manual carefully before starting experiment RayBio  Soehnle 12149105 User's Manual  HUMEX RHUME, comprimé et gélule  Pastose Beizpaste PAte de d6capage Betpasta i gel6form  CANopen  Configuration pour l`utilisation du X431BT* (écran de résolution  Handbuch - MAIR systems  

Copyright © All rights reserved.
Failed to retrieve file