1. Castle Care Tech Page 21 aaa Menu Diagnostics The Diagnostic facility allows readings of endstation power supplies and input resistances Use the B and NO keys to scroll to DIAGNOSTICS Press the YES key View PSU s will be displayed This function is used to view the endstation power supply reading Press the YES key The Endstation power supply will be shown Press the YES key and then press NO View Inputs will be displayed This function is used to view the input status Press the YES key c Closed O Open F Fault Tamper To view the resistance readings of each input press the YES key Use the D key to scroll through each input The resistance will be shown for each and will change depending on the status of the input Press YES to exit TO EXIT Calibration Do not alter this unless instructed to by customer support Press the NO key Page 22 Castle Care Tech T Menu Clean Start Clean Start To reset the EURO mini to defaults see page 25 a Clean Start may be performed Use the B and NO keys to scroll
2. B or D keys to select the address of the keypad 0 3 To install the keypad press 1 To install a reader press 2 Press the YES key Select the location of the keypad reader i e level set A B Cor D the default is A Press the YES key To create a name for the keypad press the YES key Use the letters on the buttons to create a name Press the YES key Page 12 Castle Care Tech Bue Menu System Displays Change Timers System Displays The text string on the keypad that is displayed when you exit the Engineering Menu can be changed within System Displays The function Display When Set will display which part set is set on the keypad Use the B and NO keys to scroll to SYSTEM DISPLAYS Press the YES key Enter the Sign On Message for the main display Press the YES key If the part set that is set needs to be shown when the system is set press the D key to scroll to yes Press the YES key oje CHOOSE THEN Change Timers The following timers can be changed Entry Time Exit Time 0 255 seconds S
3. ee Menu Entering and Exiting Entering the Engineering Menu When the time is displayed on the main screen enter the Engineers code default is 1111 SET UNSET SYSTEM will be displayed this can be used to set unset the EURO mini without a user code Press the NO key SOFTWARE REVISION will be displayed and the panel is now in the Engineering Menu Use the NO and B keys to scroll forward and backward through the menu Please note that all Fire and Hold Up alarms are suppressed in the Engineering Menu Exiting the Engineering Menu When a main menu item is displayed in Engineers capital letters press the A key to exit the Engineering Menu Using the B or NO keys scroll to EXIT Engineering Menu Press the YES key Castle Care Tech Page 9 Wiring Choice Software Revision Software Revision identifies the software version number this is may be asked for by the Castle Care Tech Customer Support team nonsens Menu Software Revision Use the B and NO keys to scroll to SOFTWARE REVISION Press the YES key The Software Revision will be d
4. Castle Care Tech Page 3 ntroduction The EURO mini offers the reassurance and peace of mind for protecting your customer s property whilst meeting all the relevant standards Programming of the EURO mini is the same as EURO MERIDIAN panels so this is the perfect alternative for your smaller installations The slim contemporary LCD keypad with full English text operates the EURO mini and up to 4 of these keypads can be connected to a system Castle Care Tech Limited is a UK based designer of high technology control equipment for intruder alarms and as a leading innovator Castle has won numerous awards for products and innovation in recent years The EURO mini consists of 4 level sets 10 End of Line 9 Double Pole Zones Up to 4 keypads 3 readers can be connected 8 Outputs Bell Strobe Speaker Programmable and 4 Shared with Inputs 4 Fuses Bell Aux RS485 and Battery Case Tamper and SAB Tamper 500 Mandatory and 200 Optional log events 32 Codes 30 User 1 Master Manager and 1 Engineer Different alarm responses may be programmed Keypad Prox Prox reader may be connected Page 4 Castle Care Tech Bess This chapter outlines the features and functionality the EURO mini can offer Level Set System The EURO mini can operate up to 4 part sets A B C and D An example of how these can be programmed are as follows Part Set A All All house is set Part Set B Bedtime Downstairs is set Upst
5. Timers Page 24 Castle Care Tech Output Types No Output Type Activates when the following occur Unused Always Inactive Fire Fire Inputs Hold Up Any Hold Up Inputs and Hold Up Keys I j Intruder Any Confirm Any Confirmed Alarms Tamper Any Tamper and 24 hour input alarms Set Fail unset Siren Any Strobe Any Exit Starts Any Final Set Any an Strobe Set Fail Same as Strobe Any When the set fail time expires Keyswitch Unset Activates for 5 seconds when keyswitch input is unset Entry Exit Lights seconds after set unset procedure Restore 1 Restore 2 or unset PIR Latch 2 Mains Good When mains is healthy Detector Indication En Active in walk test able Follow Test Only active when tested in Engineer Tests Off During Test Detector Walk Test Mains Fail Battery Fault Low Volts ul WwW 3 7 8 oO 0 Global Fault 1 Battery keypad mains and fuse faults when set Global Fault 2 Battery keypad mains and fuse faults any time Engineer Access When the engineering menu is accessed ep 00 _ Unused 01 Fire OOO 02 _ Hold Up Any 03 Intruder Any 06 _ Confirm Any 07 Tamper Any 11 SetFail Fal aac 14 Siren Any 16 Strobe Any 21 Exit Starts Any 22 FinalSet Any eee fal eet 33 _ Entry Exit ee 37 Restore1 38 Restore2 fall ee 40 PIRLatch2 41 Mains Good E Ser ran 43 Follow Test 44 Off During Test 48 _ Det
6. UROMmini manele a tananliate a Wtcranerct EuroMini 10U6 e Time 00 00 c xy Ra RINS1210 5 Qvs Find Guide Main Menu Item Description Software Control panel version number Revision p Wiring Choice Double Pole DEOL 4K7 2K2 or 4K7 4K7 Change Inputs Inputs types part sets attributes and input names Assign Keypads Keypad and reader addresses and keypad names System Displays Sign on message and Display when set function Volume Control Entry Exit Alarm Fire 24hr Chime Intelligent Set E E Keypads Only option Alarm Response First Alarms for each level set i 17 18 8 9 0 z Cus Page ntents P Intr ion 4 D ription Th ntemporary K Th ntemporary K Z Entering the Keypad Menu 7 Powerin Addressing Keypads 8 Engineering Men Entering the Engineering Menu 9 Exiting the Engineering Menu 9 Software Revision 10 Wiring Choice 10 Change Inputs 11 Assign Keypads Readers 12 System Displays 13 Change Timers 13 Set Date and Time 14 Exit Modes 14 Change Codes 15 Change Codes Continued 16 Volume Control 16 Alarm Responses 17 Change Outputs 17 Change Outputs continued 18 Intelligent Set 18 Site Options 18 Site Options continued 19 Review Logs 19 Engineer Tests 20 Engineer Tests Continued 21 Diagnostics 22 Clean Start 23 A ndix A 24 Input Types 24 Input Attributes 24 Appendix B 25 Output Types 25 Appendix C 26 Defaults 26 Appendix D 27 Fault Codes 27
7. key Use the B and D keys to scroll back and forth through the log If more information is required about an event press the C key When finished press the NO Key to exit Castle Care Tech Page 19 ae Menu Engineer Tests Engineer Tests The Engineer Test function allows the testing of inputs sirens and outputs Walk Test Tests each input and each part set of the system The walk test scrolls through all the inputs of the system until they are walk tested Once all are completed Walk Test Complete will be displayed Soak Control Any input may be placed on soak test to prevent it from generating an alarm If the input on soak triggers whilst the system is set it will enter the details in the system log The initial test and number of days left of the soak can also be entered after this time period the detector will become live Test Siren Tests both the siren and strobe outputs programmed as siren any and strobe any on the system Test Outputs Tests all output types For example if output 1 was programmed as fire enter 01 for the Fire output type and press YES Output 1 will activate until the NO key is pressed Use the B and NO keys to scroll to ENGINEER TESTS Press the YES key Walk Test will be displ
8. to CLEAN START Press the YES key Enter 2000 on the keypad to reset the panel back to defaults or Enter 2001 for DEOL set up or 2002 for double pole set up see page 25 for defaults Once this has been done successfully Panel has been clean started will be displayed Press the YES key To clear all codes on the system press the YES key or to keep all existing codes press the NO key Once this has been done successfully Codes have been cleared will be displayed Press the YES key To clear all logs on the system press the YES key or to keep all existing log records press the NO key Once this has been done successfully Logs have been cleared will be displayed Press the YES key Castle Care Tech Page 23 Input Types Input Attributes Input Types __ input Type Input Active Activated Outputs Sound 00 Unused Hold Up Hold Up Any Normal Alarm 06 intruder__ When Set___ Intruder Any Normal Alarm 08 Entry Route When Set__ Intruder Any Entry Normal Alarm 09 ER FX In Part When Set __ Intruder Any Entry Normal Alarm 20 K itch e Accepts input from keyswitch to set unset system 23 K itch Output type
9. Exit overrides Timed Use the B and NO keys to scroll to EXIT MODES Press the YES key Use the D key to select 0 Timed 1 Final Door 2 Timed Final final will override timed Press the YES key Lb J CHOOSE THEN Page 14 Castle Care Tech Frances Menu Change Codes Change Codes The master manager code and the engineer code can be changed here User codes can only be changed from the master manager mode please see the user manual Use the B and NO keys to scroll to CHANGE CODES Press the YES key Press the YES key to change the master manager code Press the C key to clear the existing code and enter the new one using the numeric keys Press the YES key Select the level set that the master manager code will be able to operate There are four level sets to choose from A B C D Select the master manager code to 0 Unset Set 1 Unset Only 2 Set Only If Flexi set is disabled the EURO mini will automatically set the level set which the code is assigned to If enabled the level set needs to be selected U
10. HEN Page 16 Castle Care Tech TA Menu Alarm Responses Alarm Responses False alarms can be something of an occurrence in some unstable environments The EURO mini incorporates a feature where First Alarms can be controlled The different alarm responses are silent keypad internal sounders and full alarm and each response waits 15 seconds before moving onto the next response For example If A First Alarm was selected as Silent 0 The control panel would operate as follows First to Alarm No sounds After 15 Secs Keypad sounds After 15 secs Internal sounders After 15 secs Full alarms Any second alarm that activates during the first alarm will activate all sirens bells regardless Fire and Hold Up Alarms will signal both on full alarm this cannot be changed Use the B and NO keys to scroll to ALARM RESPONSES Press the YES key Each level set can be programmed differently Use the D key to change the alarm response for each level set and press the YES key once you have chosen it Change Outputs There are a total of 7 programmable outputs on the EURO mini 4 outputs are used in conjunction with 4 inputs Inputs 7 to 10 and are labelled XPGM O P in the keypad If Inputs 7 to 10 are used then O P is an input will be di
11. Keyswitch Unset will activate when a keys Pi Pud j witch is used to disarm a partition Descriptions Intruder If the Input is triggered when the PCX 10 is armed an alarm activation will occur Final Exit This is the time that the customer has to leave the premises This acts as entry exit Entry Route Acts as an intruder input but if an entry route input is triggered before the entry route input it will act as final exit ER FX In Part On Part Set A the input acts as an entry route On Part Set B C or D it will act as an Final exit FX Part ER The inverse of the ER Part FX Keyswitch Latched Accepts an input from a keyswitch to arm and disarm the system The state of the input changes when the keyswitch is operated and then resets when the keyswitch is operated again Keyswitch Pulsed Accepts an input from a keyswitch to arm and disarm the system The state of the input changes and resets whenever the keyswitch is operated Input Attributes No No chime active Single Will produce a single chime when the input is activated Follow Will produce a continuous chime while the input is activated and will silence once closed Omittable Enables the input to be manually omitted during the setting procedure Normally Open Enables the input to work with normally open contact devices Double Knock An alarm will only be generated if this input is triggered twice within a pre set period programmed in Change
12. ONE Off ants YP y 1 Backlight on all time PA Fire Timer ct seconds keys 1 and 7 must be held for a PA to Castle Care Tech Page 7 Tag ID Present a tag for the id only applicable to EUR 068 Powers Up Initial State Once everything is connected to the EURO mini see the installation manual power up the EURO mini After inital power up the following will first be displayed may differ depending on version numbers After a couple of seconds the EURO mini will ask for the address of the first keypad Enter 00 and press the YES key Use the YES key to scroll through the different options Keyclick volume master volume etc Once all options have been chosen press the A key to Activate the keypad The day screen will be shown Addressing Keypads To address further keypads on the system press and hold the D key until KEYPAD CODE is displayed Enter 2000 This will take you to the keypad screens described above Any keypad that is new to the EURO mini must first be initialised with this function and then enabled in the Engineering menu on the master keypad address 00 The function to do this is Assign Keypads Page 8 Castle Care Tech
13. airs is unset Part Set C Pet Kitchen unset for a pet rest of house is set Part Set D Garage Only Garage set rest of house unset These are programmed in the function Change Inputs and user codes may also be programmed in different part sets Please see the user manual for this Note After a code is entered once the final door or exit time has expired a settle time of 10 seconds will take place before the system is finally set Flexi Set Flexi set can be selected for each individual user code which is used so the user selects which part sets to set unset depending on the part sets the codes are assigned to If Flexi set is set as No then once a code is entered the EURO mini will automatically set the assigned part set Please note that user codes can only be programmed in the master manager menu see the user manual Emergency Alarms The emergency buttons for the EURO mini consist of 2 buttons being pressed simultaneously These are buttons 1 and 7 At default these are disabled they will have to be enabled in the function Site Options Automatic Re arming When the bell time expires default is 4 minutes the EURO mini will automatically rearm and omit any circuits that are in open at that point The number of times it will re arm after an alarm is programmable in Change Timers In n The EURO mini consists of 10 inputs or zones that are fully programmable for detectors
14. anager menu and used to select part set D when setting Enters the keypad menu The status LEDs are as follows left to right Description Orange Used to indicate any alerts on the system Indicates that an alarm condition has occurred Indicates a tamper has occurred Indicates a fault has occurred Illuminates briefly after the system has been unset NOTE If a EUR 068 has been purchased the keypad has the prox enabled which allows arming disarming via card tag Page 6 Castle Care Tech 1s Contemporary Keypad Text Programming Text may be programmed for input names for the sign on message and to identify the level set unset Each keypad key is allocated characters as shown below le fee feel les PQRS WXYZ Press the relevant key the appropriate number of times e g for the letter k press the 5 key twice or for the letter s press the 7 key four times Other operations of each key are as follows Description Makes the character into a capital Moves the cursor to the left Deletes the letter Moves cursor to the right Adds a space Adds punctuation Entering the Keypad Menu Press and hold the D key until SECURITY CODE is displayed Enter 2000 Menu Description Address of the keypad Factory Reset Enter 2000 to reset all keypad functions to default Backlight off til key pressed entry route active Backlight Force 0 ACKI
15. ayed Press the YES key to walk test the inputs Enter the part sets that are to be tested and press the YES key The keypad will show all inputs on the system in that part set Once these are walk tested the inputs will be taken off the list Once all inputs have been walk tested successfully Walk Test Complete will be displayed Press the YES key Page 20 Castle Care Tech Continued nonsens Menu Engineer Tests Engineer Tests Continued Soak Control will be displayed Select the inputs that are to be put on soak test once finished press the NO key Enter the soak days left and the initial soak Press the YES key Test Siren will be displayed Press the YES key The Strobe and Siren outputs on the system will be activated Press the NO key to deactivate Test Outputs will be displayed Press the YES key Enter the output type that is to be tested and press the YES key All outputs programmed as the output type will be activated Press the NO key to de activate
16. door contacts fire alarms etc Each input may be programmed as normally open or with a chime or the input can be programmed as omittable so the user has control on whether or not the input needs to be active Inputs 7 to 10 can be used as outputs instead of inputs thus giving the total of 7 outputs on the system Outputs are used to connect to external devices such as signalling equipment or sirens If inputs 7 to 10 are all used as outputs then only a total of 6 inputs can be used For all programming please see either Change Inputs or Change Outputs Faults If any faults occur on the EURO mini it will be shown on the LCD keypad with a short description of the problem For more information please see page 26 Castle Care Tech Page 5 H Contemporary Keypad Functionality The Contemporary Keypad has a 32 character LCD display with encapsulated backlit keys and 5 status LEDs The operation of each key are described below Keys Description Used to enter codes and program names for Numerical panel if flexi set is enabled see the master manager menu no and resets the control panel after an alarm part set A when setting select part set B when setting c and used to select part set C when setting Moves forwards in the main menu toggles between menu choic D es enters the master m
17. ector Walk Test__ 52_ Mains Fail _ 53 _ Battery Fault 54 _ Low Volts 55 Global Fault1 56 Global Fault2 59 Engineer Access 9 Castle Care Tech Page 25 jan sei Defaults CODES User 1234 Master Manager 2222 Engineer 1111 WIRING CHOICE Clean Start 2000 2001 Detection Mode DEOL 2K2 4K7 Clean Start 2002 Detection Mode Double Pole CHANGE INPUTS Clean Start 2000 All zones and attributes disabled Po Clean Start 2001 DEOL Zones Final Exit Part Sets AB Text 01 Front Door A Part EE Part Sets AB Text 02 Hallway Intruder Part Sets AB Text 03 Lounge Intruder Part Sets AB Text 04 Dining Room Intruder Part Sets AB Text 05 Kitchen Intruder Part Set A Text 06 Landing Intruder Part Set A Text O7 Master Bed Inputs 8 9 10 Unused Omittable is enabled on inputs 2 8 Clean Start 2002 All attributes disabled Double pole zones 24 Hr Part Sets AB Text 01 Tamper Final Exit Part Sets AB Text 02 Front Door A Part EE Part Sets AB Text 03 Hallway Intruder Part Sets AB Text 04 Lounge Intruder Part Sets AB Text 05 Dining Room Intruder Part Sets AB Text 06 Kitchen Intruder Part Set A Text 07 Landing Input 8 Intruder Part Set A Text 08 Master Bed Po Inputs 9 10 Unused Omittable is enabled on inputs 3 8 ASSIGN KEYPADS Address 0 Instal
18. functions that may be necessary for the user Strobe at Set If enabled any output that is programmed as Strobe Any will activate for 5 seconds when the system sets 2 Key Hold Up Can be either enabled silent or full alarm Keys 1 and 7 on the keypad activate the Hold Up alarm Simple Set Enables the simple set functionality which allows a user to set the system by pressing the YES key and the level set Page 18 Castle Care Tech ngineering Menu Site Options continued Review logs Site Options continued Use the B and NO keys to scroll to SITE OPTIONS Press the YES key Use the D key to enable disable Strobe At Set option Press the YES key Use the D key to select O None 1 Full Alarm 2 Silent Press the YES key Use the D key to select O No 1 Yes Press the YES key TO CHOOSE THEN All set unset alarm events system faults and details of engineer access are recorded and logged in the option Review Logs each being time and date stamped Use the B and NO keys to scroll to REVIEW LOGS Press the YES key Panel Log will be displayed press the YES
19. iren Time Cut off time for a siren 2 15 minutes Fire Siren Time Cut off time for a fire alarm 1 99 Minutes Re arm Numbers automatic rearming after an alarm 0 9 9 means always Double Knock Length of time between filter period of inputs 0 75 seconds Use the B and NO keys to scroll to CHANGE TIMERS Press the YES key Enter the desired choice for each of the entry exit and siren times for each level set Then enter the re arm number and the fire siren time To move through each option press the YES key Castle Care Tech Page 13 Exit Modes T Menu Set Date amp Time SSEDEICEIRO AME Sets the date and time for the EURO mini Use the B and NO keys to scroll to SET DATE amp TIME Press the YES key Enter the Year Month Day Hours and Minutes Press the YES key Exit Modes Timed Final Door or Timed Final Door can be selected for the Exit procedure of all level sets Timed The EURO mini will set when the exit time expires programmed in Change Timers Final Door The EURO mini will set when the final exit door has been opened and closed Timed Final The EURO mini will set either when the final exit door has been opened and closed or the exit time has expired Final
20. isplayed Press YES to exit Wiring Choice Selects the EURO mini to perform as a double pole system or a double end of line system either 4K7 alarm 2K2 tamper or 4K7 alarm 4K7 tamper All wiring diagrams can be found in the installation manual Use the B and NO keys to scroll to WIRING CHOICE Press the YES key Use the D key to select 0 Double Pole 1 DEOL 4K7 Alarm 2K2 Tamper 2 DEOL 4K7 Alarm 4K7 Tamper Once the relevant wiring choice has been selected press the YES key PLEASE NOTE If Double Pole has been selected the jumper above input 1 on the printed circuit board must be removed or if resistors are used the jumper must be present Please see the installation manual for more information Page 10 Castle Care Tech eae Menu Change Inputs Change Inputs Change Inputs programs all 10 inputs For all descriptions of input types and attributes please see page 23 If Input is used as an output is shown on inputs 7 to 10 then an output is already programmed see Change Outputs page 17 Use the B and NO keys to scroll to CHANGE INPUTS Press the YES key Use the B or D keys to choose the inpu
21. led Location A Name Keypad 0 All rest unused SYSTEM DISPLAYS Sign on Message EuroMini 10V6 e Display When Set No CHANGE TIMERS Entry Time 30 secs Exit Time 30 secs Siren Time 4 Minutes Re Arm No 3 Fire Siren Time 99 mins EXIT MODES Clean Start 2000 Part Sets A B C and D Timed Clean Start 2001 2002 Part Set A Timed Final VOLUME CONTROL Entry 4 Exit 4 Alarm 7 Fire 7 24Hr 6 Chime 3 Intel Set 3 E E Keypads Only No ALARM RESPONSE First Alarm Part Sets A B C and D Full Alarm CHANGE OUTPUTS Bell Siren Any STB Strobe Any PGM PIR Latch 1 XPGM 1 2 3 4 Unused INTELLIGENT SET Now SITE OPTIONS Strobe At Set No 2 Key Hold Up None Simple Set No Page 26 Castle Care Tech Fault Codes Faults Descriptions AUX Fuse Flt 100 Auxiliary fuse failure or excessive current detected BELL Fuse Flt 100 Bell fuse failure or excessive current detected Case Tamper 100 Case tamper open the terminals TAMPER or the tamper spring 485 Fail 2xx Keypad failure xx the address of the keypad that has failed Mains Absent No mains supply detected to the control panel Castle Care Tech Page 27 Censor Dees Castle Care Tech Ltd First Floor 6 Bracknell Beeches Old Bracknell Lane West Bracknell Berkshire RG12 7BW Helpdesk 01344 469499 Opening Hours 7 00am 7 30pm Monday to Friday E mail support castle caretech com W ite www castle caretech com
22. se the D key to select yes or no press YES key To create an user name enter the text using the letters on the keypad Press the YES key Castle Care Tech Page 15 ngineering Menu Change Codes continued Volume Control Change Codes Continued Press the YES key to change the engineer code Press the C key to clear the existing code and enter the new one using the numeric keys Press the YES key Volume Control Sets the volume of the entry and exit tones for each level set and the Fire 24 hour Chime and Intelligent Set E E Keypads is an option that sounds all the entry exit tones from the keypad only and not any internal speakers connected to the SPK terminals Note Volume level 1 is silent but sounds a beep when the system is set Use the B and NO keys to scroll to VOLUME CONTROL Press the YES key Enter a number between 0 for silent and 7 loudest and press the YES key to go to the next option After the volume options EE Keypads will be displayed If EE Keypads Only is enabled all entry exit sounds will be heard from the keypad only Use the D key to toggle the option Press the YES key o TO CHOOSE T
23. splayed on the output type and that output cannot be used until the input is made unused For a full list and descriptions of the outputs please see page 24 Use the B and NO keys to scroll to CHANGE OUTPUTS Press the YES key Castle Care Tech Page 17 Intelligent Set renee Menu Change Outputs continued Site Options Change Outputs continued Use the B and D keys to scroll through the different outputs Once chosen press the YES key to move onto the next output If O P is an input is displayed on the XPGMs then the output cannot be used as an input is already programmed If not select the relevant output types and press YES Intelligent Set When intelligent set is enabled then level set B will start to set if the user code is enabled in level set B Then if a Final Exit input is activated which is programmed in level set A during the exit time then the EURO mini will automatically quick set in level set A Use the B and NO keys to scroll to INTELLIGENT SET Press the YES key Use the D key to enable disable Intelligent Set and press the YES key Site Options Site Options contain 2
24. t number Press the YES key Select the input type using the B and D keys Press the YES key For a full list of the inputs and descriptions please see page 23 Select the level set that the input will be in There are four level sets to choose from A B C D Press the YES key Press the YES key to go into Input Attributes Chime Omittable Double Knock and Normally Open Select Yes or No to each attribute by using the D key Press the YES key To create an Input name press the YES key and use the letters on the buttons to create a name Press the YES key Castle Care Tech Page 11 nanesemo Menu Assign Keypads Assign Keypads Readers Keypads can be allocated to different part sets and up to four keypads can be added to the EURO mini For Example if 2 keypads are installed on the system one upstairs one down stairs the location of the keypad downstairs will be A for a full set and the location of the keypad upstairs will be B for a part set Use the B and NO keys to scroll to ASSIGN KEYPADS Press the YES key Use the