1. Multiple button model to access different areas Anti vandal construction Flush or Surface mount Electronic control of Volume and Microphone sensitivity to adjust unit to local environments Improved Busy tone detection to suit most PABX types 3 Compliance The DS B series Door Station is fully approved and meets the Australian Communications Authority ACA requirements for Electrical Safety Telecommunications and Electromagnetic Compatibility EMC Warning The DS B Series Door Station has been designed for connection to a PABX and is not approved or intended for direct connection to the Public Switched Telephone Network PSTN 4 Installation 4 1 Mounting the Front panel Flush mount units should be fitted in a cavity size as specified and fixed using wall plugs or other suitable fixings Suggested hardware is 25X6mm wall plugs and 8G stainless steel tamper torx screws which can be supplied on request Refer to separate instructions supplied with the various brass and stainless steel front panels surface mount brackets and plastic units 4 2 Power Supply The telephone section of the Door Station is Line Powered from the telephone line If fitted the Door Station relay driver and LED will require 15 to 28V DC unregulated power Page 3 of 8 DS B Series Door Station Revision 50 NFcomms User Manual 4 3 4 4 4 5 4 6 4 7 The power input can be provided from the extension
2. Door strike 5 when Relay Code entered Pins 1 amp 2 Orange Pair Power for the unit can be supplied Fig 1 Premier PABX Extension port viewed from 1 directly from the Premier PABX via pair 2 of the Premier s eee modular RJ12 extension port The inner pair pair 1 of the modular connector 12 plug is the extension line pair ee hie pin 4 L 2 or from a 15 to 28V DC 500mA plug pack z NC A NC Pin 1 Orange is the common Power GROUND Q pin 2 pos Pin 2 Orange VVhite is 15 to 28V DC input power Note The voice circuit of the Door Station is line powered and will operate without external power The power on Pins 1 amp 2 is only required to supply power to the button LED the Door relay and external Door Strike coil and optional camera if fitted if none of these features is used power on Pins 1 amp 2 is not required Pin 3 Brown wire Provides a nominal 12V to a door solenoid when the Door Relay code is applied Other terminal of solenoid must be connected to the Power ground Pin 1 or Orange Pin 3 is protected from temporary accidental shorting Pins 4 amp 5 Green Pair Uncommitted contacts Normally Open NO These contacts CLOSE when the Door Relay code is applied These contacts are rated at 1A 30VDC Pin 5 Green wire and Pin 6 Brown white wire Uncommitted contacts Normally Closed NC These contacts OPEN when the Door Relay code is applied These contacts are rated at 1A 30VDC Blue L
3. 1 Parallel mode Door Relay Tone vvhen activated 0 Silence 1 Beeps Door Relay Mode 0 Normaliy OFF 1 Normally ON Read settings Page 7 of 8 DS B Series Door Station Revision 50 NFcomms User Manual DTMF Description Command 8 Immediate Action 80 Turn Door Relay OFF 81 Turn Door Relay ON 82 Sound firmvvare version 3 digits beeps count out each digit digit 0 is one lovv tone 83 Sound the value of the Call Duration setting 84 Sound the value of the units STATUS 85 Sound the value of the Option setting 86 Control the state of the Test Ringer 87 Sound the value of the Flash Option setting 88 Sound ring loop counter 89 xxx Send a command to the controller Administration Commands 91 Read Serial Number 92 Read Administration Unlock Key used by Factory to generate Reset Code 96 x Set Identifier x 0 9 default 1 PARALLEL MODE ONLY 97 Set the Serial Number Factory set 98 Enter Administration Reset Code contact Factory to assist vvith forgotten Access Code aaaa Enter Administration Mode aaaa is Access Code Default 1234 Enter this command from a remote phone or from Keypad if fitted User Operational Commands from Keypad Keypad model only Operate Door Relay Press Call button first eeee is the 4 to 6 digit Door Relay Activation Code set with the 2 command Hangup will occur at completion of door release To stop fraudulent door e
4. ports of the Premier PABX itself pair 2 power or from a plug pack The Premier s auxiliary power feed can be used to povver both the Door Station s LEDs and an optional Door Strike coil provided the Door Strike coil needs less than 400mA at 12V There is insufficient power from the Premier to feed the DS Series with the Camera option so an external plug pack is required if the camera option is fitted Summary of Power requirements Hands free Door Relay Door Relay Telephone LED LED Camera Connection hrough PSTN Orange Pair Orange Pair or PABX line non polarized non polarized Voltage Line Powered 15 28VDC 15 28VDC nominal 48V or 24V Current Line Powered 400mA 800mA nominal minimum minimum 25mA Set up Various parameters on the DS B Series be programmed refer section 5 The DS B series Door Station by default sends the DTMF sequence 27 when the Door Button is pressed and 28 if the 2 button is pressed on 2 button models If connected to the Premier SOHO PABX all telephone extensions will ring when 27 or 28 is dialled The Premier will need to be programmed if selected extensions are required to ring Refer to Premier Programming manual for information on how to program selective ringing for extensions Door Strike A door strike coil can be connected directly to the brown pair When key 2 is pressed programmable on the remote telephone upto 12VDC at upto 400mA will be provided to the
5. DS B Series Door Station Revision 50 NFcomm 5 User Manual DS B Series Door Station User Manual Applies to Rev 3 and Rev 4 Hardware loaded with Software Version 6 16 or higher Revision 50 Copyright 2011 NF Communications NFcomms Designed and Manufactured in Australia by NF Communications P L Anthony Street Ormond VIC 3204 Tel 03 9532 5112 Fax 03 9576 8521 Web www nfcomms com au Page 1 of 8 DS B Series Door Station Revision 50 NFcomms User Manual Page of 07 O DS B Series Door Station Revision 50 NFcomms User Manual 1 Introduction The DS Series Door Station series is intended as a hands free speaker telephone situated at a door or gate and is connected to a suitable analogue extension of a PABX or key system such as the Premier SOHO PABX Pressing the button of the Door phone will initiate the automatic sending of a DIMF number sequence which will be analysed and handled by the PABX The DS B Series is suitable for flush mounting in any wall with a cavity about the size of half a standard house brick A surface mounting bracket option is available 2 Features Sealed to IP54 for protection against rain water splashes and dust Voice circuit is Line powered so main function will still work if external power fails External plug pack power required for Door strike and optional camera Stainless Steel Anodised Aluminium or Brass front panel options
6. Door strike coil for 3 seconds programmable Independent contacts are also controlled by the Door Strike operation The Door Latch code and the duration of the relay ON time can be programmed see command list Volume and Microphone sensitivity Adjustment Both Volume and Microphone sensitivity can be adjusted remotely by command Also the balance between the strength of the signal from the line or the microphone can be adjusted These commands allow the unit s parameters to be tuned to suit the site s acoustic environment Automatic Answer for Parallel connected Units Units can be connected in parallel to share the same line For incoming calls the units can be configured so that both units will automatically answer the call rather than only one at random Contact NFcomms for details Cabling The Door Station cabling should be installed according to AS NZ 3086 Telecommunications Installations Integrated telecommunications cabling systems for small office home office premises If the Cable Tail wires will be subjected to weather conditions they should be connected using silicon filled telecom insulation displacement connectors to ensure weather proofing of the connections Page 4 of 8 DS B Series Door Station Revision 50 NFcomms User Manual To PABX From plug pack or Premier Pair 2 Uncommitted contacts These switch when Relay Code is entered 12V 12V appears Power OUT to on Brown wire
7. INE pair Voice Line pair Note If using the Premier SOHO PABX the Door Station can be connected to any extension of the Premier however it is suggested that extension 8 not be used for the Door Station as this should be reserved for the emergency access telephone for use when power fails Refer to the Premier User Manual Page 5 of 8 DS B Series Door Station Revision 50 NFcomms User Manual 5 Programming Various parameters can be programmed on the DS series Door Stations 5 1 Initiating a connection to the Door Station To start a programming session a connection must be made between a standard DTMF telephone and the Door Station through a PABX Connect the Door Station to one extension of a PABX and a standard DTMF capable telephone to another extension Use the standard DIMF capable telephone and call the Door Station The default setting for the Door Station is to automatically answer an incoming call The Door Station can be programmed to manually answer an incoming call by pressing the button see command 6 Commands are entered using DI MF tones to change the parameters 5 2 Administration mode Enter the Admin Mode by entering the command 1234 The default Access Code is 1234 and can be changed if required The LED will flash faster than normal to indicate Admin Mode NOTE All commands that require a new value to be stored will need to be entered in Admin Mode Other commands such as Read Software Vers
8. inger volume See 750 command 0 OFF 1 Lovv 2 High Default 522 Dynamic Operational Characteristics Set all dynamic parameters 6 commands to FACTORY DEFAULT Control LLC LIV and Background Noise BGN x 0 to 7 Control LLC and LIV only x 8 Disable BGN No change to LLC LIV x 9 Enable BGN as defined by setting provided in 69xx Set minimum dial tone detection time O to 9 sec Default 2 sec example 622 Set microphone sensitivity 0 low 9 high Default 5 example 635 Set microphone sensitivity boost for parallel mode 0 9 default 3 Set speaker boost for parallel mode 0 9 default 3 Busy tone detection x 0 default x 1 Fili x 3 Panasonic Set speaker volume 0 low 9 high Default 5 example 675 Set balance between mic and speaker 0 most emphasis on mic Default 5 ex 685 Set BGN level and Hands Free switching speed nn 0 to 15 Contact NFcomms for details For example nn 00 BGN 120mv MAX switching speed Nn 08 BGN 240mv MAX switching speed Read settings Feature Control Set all Features 7 commands to FACTORY DEFAULT default settings are highlighted FLASH LED during call 0 Solid 1 Flash LED during a call Enable Busy Tone detection 0 Enable 1 Disable Keypad 0 Not installed 1 Installed default set for appropriate model Multi LED 0 Single LED only 1 Multi LED default set for appropriate model Answer Mode 0 Manual Answer 1 Auto Answer Single Parallel Mode 0 Single mode
9. ion 82 can be entered without going into Admin Mode 5 3 Entering Commands Commands are started with Successful commands are acknowledged with 2 short beeps Failed commands are indicated by 1 long beep For commands that read values beeps count out each digit One low tone represents 0 For example 405 sounds out with 4 beeps quiet 1 low beep quiet 5 beeps Description Destination Numbers Change the number sent when call button b is pressed b is the button number 1 to 5 where fitted nnnn is the destination number and can be 0 to 15 digits long Note To enter a pause or special characters into the digit string use prefix as detailed below Eg 110 1395251234 means that when button 1 is pressed the digits 0895251234 will be dialled with a 1 sec pause after the 0 digit To loop line without sending digits set nnnn blank for example 12 means that when button 2 is pressed the line will be looped but no digits will be sent DTMF Command 1b nnnn 2 Access Codes and Limits 200 Set 2 range of commands to FACTORY DEFAULT 201 Disable all Keypad Door Relay Activation Codes 21 8 Keypad Door Relay Activation Code 1 eeee is 4 to 6 digits 22 eeee Keypad Door Relay Activation Code 2 eeee is 4 to 6 digits 23 Keypad Door Relay Activation Code 3 eeee is 4 to 6 digits 24 Keypad Door Relay Activation Code 4 eeee is 4 to 6 digits 25 ff Keypad Door Re
10. lay Activation Code 5 eeee is 4 to 6 digits 28 nnn Set Keypad DTMF allowable dial length Default 4 Phone Point 255 29 aaaa Change Administration Access Code Default 1234 Timer Configuration 30 Set all timer values to FACTORY DEFAULT 31 m Call Duration Time in minutes 0 to 9 Default 4 min 0 no timeout example 314 32 ss Door Relay ON Time in seconds 0 to 30 Default 4 sec example 324 33 ss Button Dial Out Delay in 0 1 secs 0 to 99 Default 0 eg 330 Page 6 of 8 DS B Series Door Station Revision 50 NFcomms User Manual DTMF Command 4 Al nn 42 nn 43 X 5 510 511 512 l 514 1515 516 152X 60 61 62 n 63 n 64 65 n 66 67 68 69 62 7 70 71 n 72 n 73 n 74 n 75 n 76 n 77 n 78 n 7 Description DTMF Only Access Codes Enter from remote telephone Door Relay Activation Code Default 2 example 412 Hangup Code Default 99 example 4299 Parallel Mode ONLY Units that match Identifier x 0 9 will stay ONLINE and change to SINGLE MODE All non matching units will hangup Answer Tone Tone that sounds when call is answered and Ringer Volume No tone on answer Set Answer Tone to Tone 1 Set Answer Tone to Tone 2 Set Answer Tone to Tone 3 Default Set Answer Tone to Tone 4 Set Answer Tone to Tone 5 Set Answer Tone to Tone 6 R
11. ntry attempts the Door Station will delay hanging up for 60s after 3 or more successive incorrect attempts have been made Once a correct Activation Code is made the Door Station will revert to normal operation dddd Press Call button first then Dial Extension dddd is the extension number to be called length limited by 28 command Dial string command 1b To enter digits special characters and pauses into the dial string use the following DTMF keys on the telephone Enter prefix to enter a special character Enter to terminate the string entry u 7 in For example consider dial string la s ring 57 0987612324 for button 1 To store this string for button 1 vvith a 2 m f second pause after the digit 0 enter m A EE the following command gt FA Eze 1 110 298761234 asli s Ts Premier PABX 5 47 7755 s 1 second pause d 2 second pause DTMF A DTMF B a DTMF C ic DTMF D The 8 RJ12 extension ports of the Premier PABX Page 8 of 8