Home
GOT2000 Series Video/RGB Input Unit User`s Manual
Contents
1. PLCs for line control Personal computer 24 4 Power on the GOT simultaneously with the camcorder 2 Depending on the camcorder type noise from the power supply cable of the camcorder may cause malfunction of the GOT or a programmable controller In this case attach the following line filter to the power supply line of the camcorder Recommended line filter TDK Lambda RSHN 2003 or equivalent products 3 If the flickering of the screen occurs due to the noise from the RGB cable attach the following ferrite core to the RGB input section Recommended ferrite core TDK Lambda ZCAT3035 1330 or equivalent products 4 When connecting any of the above units to a personal computer ground the ground cable of the personal computer To use the video input unit video RGB input unit and RGB input unit set the controller settings For the settings and system configurations refer to GOT2000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT Works3 Version 1 For the details of the video input video RGB input and RGB input function refer to GT Designer3 GOT2000 Help 2 SPECIFICATIONS The performance specifications of the video input unit video RGB input unit and RGB input unit are indicated below The general specifications of the video input unit video RGB input unit and RGB input unit are the same as those of the GOT Refer to the User s Manual for th
2. MITSUBISHI ELECTRIC GOT2000 Series Video RGB Input Unit User s Manual GT27 V4 Z Set of GT16M V4 Z and GT27 IF 1000 GT27 V4R1 Z Set of GT16M V4R1 Z and GT27 IF1000 GT27 R2 Z Set of GT16M R2 Z and GT27 IF 1000 Thank you for purchasing the GOT2000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT27 V4R1 Z U JE MODEL CODE IB NA 0800519 B 1407 MEE 1D7ML4 GRAPHIC OPERATION TERMINAL GOTZE OOO SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals intro duced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION I Indicates that incorrect handlin g may cause hazardous l l AWARNING conditions resulting in death or severe injury l I l Indicates that incorrect handling may cause hazardous l l A CAUTION conditions resulting in medium or slight personal injury or physical damage Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to per sonal safety Please save this manual to make it a
3. shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions A CAUTION Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Make sure to securely connect the cable to the connector of unit Incorrect connection may cause malfunctions STARTUP AND MAINTENANCE PRECAUTIONS ZA AWARNING Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure A CAUTION Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure
4. NAL DIMENSIONS 3 1 GT16 Video RGB Input Unit GT16 Video Input Unit and GT16 RGB Input Unit The external dimensions for all the units are the same except the connector dimensions of the video input section and the RGB input section 1 2 GT16M V4R1 Z 133 5 24 GT16M V4 Z i 7 GT16M R2 Z fa Pu Fi ge S a GT16M V4R1 Z T _ i o j oO Uo 1 Lo aed 1 i S o a zg JHR E Za Alo A oo oe 3 eu S D DSPLAY SDE 10 co o i 4 a GT27 IF 1000 qo 9 GOT main unit Shi i Ea 34 26 19 5 6 0 71 0 71 1 34 1 02 0 75 7 GT16M V4 Z NI 7 on y S 0 I Z lis is 34 45 6 0 71 0 71 1 34 1 77 5 GT16M R2 Z 4 a a Mme OMS ay 2a o Wl u es cz REAR SOE MS g bap B
5. anch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electro
6. ccessible when required and always forward it to the end user DESIGN PRECAUTIONS A CAUTION Donot bunch the control wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100mm 3 94 inches otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS Z AWARNING Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction CAUTION Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT used Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not drop the unit or subject it to string shock A unit damage may result When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range 0 36 Nem to 0 48 Nem with a Phillips head screwdriver No 2 Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS Z AWARNING Be sure to
7. e GOT used for the general specifications of the GOT Specifications GT16M V4 GT16M V4R1 GT16M R2 NTSC format PAL Video Color format interlaced format input format Monochro EIA format CCIR format me interlaced format Number of video input 4 channel channels Input signal IVp p 75Q composite signal 640 X 480 dot 768 X 576 dot 720 X 480 dot Display size Connector for external BNC connector connection Analog RGB XGA 1024 X 768 dot SVGA 800 X 600 dot VGA 640 X 480 dot RGB input method Number of video input 1 channel 2 channels 2 channels Input image signal 1Vp p 7502 eae Synchronizing signal TTL 1kQ inpu nen 1024 X 768 dot refresh rate 60Hz 800 X 600 dot refresh rate 60 72 Display size 75Hz 640 X 480 dot refresh rate 60 72 75 85Hz Connector for external connection D Sub15 pin female 3 3 VDC 0 32A 0 51A 0 49A Internal current consumption 50 cies 0 39A 0 35A accompa accompanied accompanied nied with the VDC with the with the GT27 GT27 IF1000 GT27 IF1000 IF1000 i 0 34kg 0 36kg 0 33kg accompanied accompanied accompanied with with the with the GT27 the GT27 IF1000 GT27 IF1000 IF1000 1 Compatible with PAL and CCIR formats only 2 The GOT cannot display both video images and RGB screens at the same time 3 The GOT can display only one RGB screen 3 PART NAMES AND EXTER
8. e RBIN D N Q i a DISPLAY SDE J DISPLAY SDE oO Fj Unit mm inch Description Extension connector Connector for connecting an extension unit Mounting screw Screw for fixing the Video Interface Converter Unit Rating plate Connector for RGB input Connector for connecting 9 core combined cables Video connector connected to the Video Interface Video connector Converter Unit Connector connected to the Video Interface Converter Interface connector Unit Connector for video input Connector for connecting a coaxial cable Unit mm inch Description Connector for connecting the GT16 Video RGB Input Pension connertce Unit GT16 Video Input Unit or GT16 RGB Input Unit Mounting screw Screw for fixing the GOT Rating plate Video connector for connecting the GT16 Video RGB Input Unit GT16 Video Input Unit or GT16 RGB Input Unit Video connector Auxiliary extension connector Auxiliary extension connector connected to the GOT Interface connector Extension connector connected to the GOT 4 INSTALLATION AND REMOVAL PRO CEDURE 4 1 Unit Installation The installation procedure for the video RGB input unit is explained using the GT2712 1 Turn off the GOT 2 Pull up the two hooks in the extension unit cover two covers of the GOT to remove the cover toward the opposite sid
9. e of the hoots of the cover as a fulcrum 3 Connect the Video Interface Converter Unit to the auxiliary extension interface and the extension interface on the GOT After connecting it tighten four mounting screws 26mm with a torque of 0 36Nem to 0 48Nem to fix the unit 4 The connector for video input has the protection cap Remove the protection cap for the connector to be used Store the removed protection cap 5 Fit the GT16 video RGB input unit n the Video Interface Converter Unit case 6 Tighten four mounting screws 40mm of GT16 video RGB input unit with a torque of 0 36Nem to 0 48Nem to fix the unit 8 For mounting no extension unit on the unit cover over four mounting screws with the accessory stickers to the GT16 video RGB input unit the GT16 video RGB input unit or the Video Interface Converter Unit to avoid static electricity Keep the connector cover fixed Keep all the stickers fixed Connector cover Accessory sticker Accessory sticker 4 2 Unit Removal For removing the Video RGB Input Unit Video Input Unit and RGB Input Unit reverse the procedure of the installation Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mi
10. face Converter Unit GT27 IF 1000 Mounting screw set 2 screws 26mm 2 stickers 1 OVERVIEW This User s Manual describes the following units When mounting the following units with the GT27 the GOT can display video images taken by a camcorder or a RGB screen The GT 27 video input unit GT27 V4 Z hereinafter referred to as the video input unit is configured with the GT 16 video unit and the Video Interface Converter Unit For the video input unit the GOT can display video images taken by up to four camcorders e The GT 27 video RGB input unit GT27 V4 Z hereinafter referred to as the video RGB input unit is configured with the GT16 video RGB input unit and the Video Interface Converter Unit For the video RGB input unit the GOT can display video images taken by up to four camcorders or a RGB screen for up to one device for the RGB input e The GT27 RGB input unit GT27 R2 Z hereinafter referred to as the RGB input unit is configured with the GT16 RGB input unit and the Video Interface Converter Unit For the RGB input unit the GOT can display only one RGB screen by switching up to two video input channels For the video input with using the above units the GOT can be used as a vision sensor monitor For the RGB input unit with using the above units the units can be used as the RGB output type vision sensor GOT
11. l Microcomputers MODBUS Products Peripherals For GT Works3 Version SH 081200ENG 1D7MK2 For detailed manuals refer to the PDF manuals stored in the DVD ROM for the drawing software used Relevant Manuals For relevant manuals refer to the Help or the PDF manuals stored in the DVD ROM for the drawing software used The latest manuals are also available from MITSUBISHI ELECTRIC FA Global Website http Avww MitsubishiElectric co jp fa 2013 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT EMC and Low Voltage Directives compliant into other machinery or equipment refer to EMC AND LOW VOLTAGE DIRECTIVES of the General Description included with the GOT used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the GOT Packing List After unpacking the box check that the following products are included Product Quantity GT16 Video input unit GT16M V4 Z GT27 V4 Z Video Interface Converter Unit GT27 IF 1000 Mounting screw set 2 screws 26mm 2 stickers GT16 Video RGB input unit GT16M V4R1 Z GT27 V4R1 Z Video Interface Converter Unit GT27 IF 1000 Mounting screw set 2 screws 26mm 2 stickers GT16 RGB input unit GT16M R2 Z GT27 R2 Z Video Inter
12. nic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan July 2014
13. to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual for the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation TRANSPORTATION PRECAUTIONS CAUTION When fumigants that contain halogen materials such as fluorine chlorine bromine and iodine are used for disinfecting and protecting wooden packaging from insects they cause malfunction when entering our products Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products or treat packaging with methods other than fumigation heat method Additionally disinfect and protect wood from insects before packing products Manuals The following shows manuals relevant to this product Detailed Manual Manual number Manual name Model code GOT2000 Series User s Manual Hardware SH 081194ENG Sold separately 1D7MJ5 GOT2000 Series Connection Manua
14. tsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system SSS Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Br
Download Pdf Manuals