SW-AV1-DV1 Instruction Manual
Contents
1. Alternate fast two tone 2500 3100 0 25 00111 Security Deterrent 5 Alternate two tone 440 554 0 4 0 1 11011 Evacuation Alarm France 6 Alternate two tone 430 470 1 0 01011 7 Alternate v fast two tone 800 1000 0 13 10011 8 Alternate v fast two tone 2500 3200 0 07 00011 9 Alternate two tone 440 554 2 0 11101 Turn out SWEDEN 10 Continuous note 700 01101 All Clear SWEDEN 11 Continuous note 1000 10101 12 Continuous note 1000 00101 SW AV1 DV1 Instruction Manual Rev 1 1 Page 7 of 10 deteon inc SW AV1 DV1 Sound Signal Frequency Repetition Switches Special Applications Rate SW1 SW2 13 Continuous note 2300 11001 14 Continuous note 440 01001 15 Interrupted tone 1000 2 0 10001 16 Interrupted tone 420 1 25 00001 17 Interrupted tone 1000 0 5 11110 18 Interrupted tone 2500 0 25 01110 19 Interrupted tone 2500 0 5 10110 20 Interrupted tone 700 6 12 00110 Pre vital Message SWEDEN 21 Interrupted tone 1000 1 0 11010 22 Interrupted tone 700 4 0 01010 Air raid Alarm SWEDEN 23 Interrupted tone 700 0 25 10010 Local Warning SWEDEN 24 Interrupted tone 720 0 7 0 3 00010 Industrial Alarm GERMANY 25 Int fast rising volume 1400 0 25 11100 26 Fast siren 250 1200 0 085 01100 27 Rising constant fall 1000 10 40 10 10100 Industrial Alarm GERMANY 28 ISO 8201 Evacuation 800 1000 as std 00100
2. Elgure 3 Strobe Horn Combos cias a ck Bebe aaa 2 Figure 4 Smart Battery Packs a As 3 Figure 5S Quad Battery Charger scsissi zssstcsccesceeiscnetey iced ir leash dudes donddetiachoedengoceteesis a a 3 Elgure 6 Alarm Dimensional iria init ce 5 Fisur 7 Alarm Switch location eiiieaen naie e a e a eR ects EEr AE pec rE erecta eet guctinsete 7 SW AV1 DV1 Instruction Manual iii a detcon Inc SW AV1 DV1 This page left intentionally blank Shipping Address 4055 Technology Forest Suite 100 The Woodlands Texas 77381 Mailing Address P O Box 8067 The Woodlands Texas 77387 8067 Phone 888 367 4286 281 367 4100 Fax 281 292 2860 e www detcon com sales O detcon com SW AV1 DV1 Instruction Manual iv a SW AV1 DV1 deteon inc 1 0 Description The Detcon SW AV1 DV1 Alarm Stations are wireless battery powered alarm stations with a 5 Joule Strobe and an 110Db Imtr Horn The SW AV1 DV1 uses a Horn Strobe Combo Alarm The units are designed for installation and use in hazardous duty corrosive work environments rated at Class 1 Division 1 Groups C and D Figure 1 Basic C1D1 Wireless Alarm Stations The alarm station can be positioned almost anywhere since the wireless ability of the unit means that there is no need for running conduit or cables The alarm station is powered by an internal 12V battery pack Communication is performed via the Detcon RXT 30
3. keyed to prevent incorrect positioning and connection Each port has its own FAULT LED indicator and CHARGE LED indicator and will display either a red light or green light depending on the status of each battery being charged Charging times will vary depending on the charge state of each battery pack but a full charge of a depleted battery pack can take up to 24 hours Figure 5 Quad Battery Charger SW AV1 DV1 Instruction Manual Rev 1 1 Page 3 of 10 detcon Inc SW AV1 DV1 When first powered on and with no battery packs connected to the charger all the LED indicators on the Quad Charger should be green When a battery pack is seated into a charging port the CHARGE LED will go from green to red indicating the battery pack is not sufficiently charged Once fully charged the LED will go from red to green and the battery pack is ready to be used The Fault LED should remain green indicating that there are no problems with the battery pack or charging port If the Fault LED turns red with the battery pack connected then there is a problem or issue with the battery pack and it should not be used and be removed immediately If the Fault LED turns red without a battery pack connected to the charge port then there is a problem or issue with the port and that port should no longer be used Battery packs can remain connected to the charger even after a full charge indication Green Charge LED is shown due
4. original purchaser and ends one year thereafter All warranties and service policies are FOB the Detcon Inc facility located in The Woodlands Texas SW AV1 DV1 Instruction Manual Rev 1 1 Page 9 of 10 a detcon inc 7 0 Revision Log SW AV1 DV1 Revision Date Changes made Approval 0 0 02 21 11 Initial Release LBU 1 0 11 30 11 Updated Mounting Plate Specifications and Spare Parts List LBU 1 1 03 11 14 Updated Specifications and Detcon address LBU SW AV1 DV1 Instruction Manual Rev 1 1 Page 10 of 10
5. that the area is de classified Remove the cover from the junction box Release the battery catch and install the battery The battery can only be installed one way and orientation is mandated by the battery supports and the connector Ensure that the battery is completely seated and close the retaining lever over the battery until it latches The unit will power up and begin normal operation Replace SW AV1 DV1 Instruction Manual Rev 1 1 Page 5 of 10 a detcon Inc SW AV1 DV1 the cover on the junction Box and ensure that the cover is completely screwed down and secured by the cap head screw Battery operation can be supplemented by the addition of an external 24 VDC power source The unit should not need the addition of an external 24VDC power source but if an external 24VDC is to be added J6 is provided for connection to the 24 Volt input refer to Figure 2 This voltage will be used to charge the battery pack as well as aid in operation of the alarm station SW AV1 DV1 Instruction Manual Rev 1 1 Page 6 of 10 a deteon inc 3 0 Operation SW AV1 DV1 The Wireless C1D1 Alarm Stations provide a strobe and a horn two strobes or a single horn The wireless alarm station is set to respond to alarms from the controlling unit The controller has independent control over the strobe and the Horn and they will be activated when the appropriate alarm is activated All strobes have a flash rate of 1 Hz one flash per second The horn
6. 0 or RXT 320 series of transceivers Access to the unit is only necessary for battery maintenance or exchange With the addition of a solar panel access can be kept to periodic functional tests and checks Internal wiring between components runs through the Wireless Alarm Interconnect PCA This PCA controls the state of the alarms via communication with the Wireless Transceiver When an alarm is triggered the wireless transceiver will provide the interconnect PCA with the signal s necessary to activate the proper alarm s wiring to from Transciever UTE ES wiring to from gt m l Transciever UU Transcieve External yyy eeoaak 24VDC n connections lL JL ALA Rotary Switch Hilal HH ao LN all all for Modbus Fae no ee Address uf UL Alarm 2 Alarm 1 wiring a wiring Figure 2 Wireless Interconnect PCA SW AV1 DV1 Instruction Manual Rev 1 1 Page 1 of 10 detcon Inc SW AV1 DV1 If the unit uses the RXT 320 Transceiver the rotary switch on the Wireless Alarm Interconnect PCA is used to set the Modbus Address of the alarm unit If more than one alarm station used in the system each alarm station must have a unique address for the alarm station to be recognized on the network properly This switch is not use
7. International Evacuation Alarm 29 Fast whoop 500 1000 0 15 11000 30 Slow whoop 500 1200 4 5 01000 Evacuation Alarm Netherlands 31 Reverse sweep 1200 500 1 10000 Evacuation Alarm GERMANY 32 Siren 500 1200 3 0 00000 4 0 Parts List Detcon Part Description 355 YL66x4 024 356 Y A6624 024 500 005 146 000 976 000300 000 976 000320 000 976 0BP303 290 SW AV1 DV1 Instruction Manual Rev 1 1 Combo Strobe Horn where x 2 Red 4 Amber 5 Green 6 Blue 9 Clear Horn alarm only 24V Wireless Alarm Interconnect PCA RXT 300 Wireless Transceiver RXT 320 Wireless Transceiver 12VDC 2900mAh Battery Pack Page 8 of 10 a detcon inc 5 0 Specifications Voltage Operating Current Dome Colors Dome Guard Strobe Output Flash Rate Horn Output Horn Tone Operating Temperature Minimum Operating Temperature Maximum Enclosure Rating Dimensions 6 0 Warranty SW AV1 DV1 24VDC 590mA 24VDC 350mA Horn Typical 220mA Strobe Typical Amber Blue Clear Green Red Opal Yellow Included SJoules 1 per second 110db A 1 meter Selectable 20C 60C CID1 Gas Group CD CIID1 Gas Group EFG 30 H X 16 5 W X 8 D AV1 Strobe Horn Combo Detcon Inc as manufacturer warrants under intended normal use each new SW AV1 DV1 SW V2 DV1 and SW A1 DV1 Alarm station to be free from defects in material and workmanship for a period of one year The warranty period begins from the date of shipment to the
8. d with the RXT 300 Transceivers 1 1 Strobe Horn Alarm Several variations of Smart Wireless alarm stations are available The strobe horn combination is used with the wireless SW1 AV1 DV1 Alarm Station Two single strobe units are used with the V2 DV1 Alarm Station The Smart Wireless alarm station is also available with a single horn in the SW A1 DV1 model All units are UL listed and CSA certified for Class I Division 1 Groups C and D Class II Division 1 Groups E F and G Figure 3 Strobe Horn Combo The horn in the alarm stations has 32 possible combinations of sounds that are selectable by switch settings inside the alarm Horn only units provided a dual horn capability Horn one and horn two can be set to different tones via the switch settings SW1 is used for horn 1 and SW2 for horn two settings These horns can be initiated individually but if both horns are active horn two has priority Refer to Section 3 0 for a list of the available switch settings 1 2 Smart Battery Pack The Wireless Alarm Station assembly also comes with a battery pack that allows the assembly to be remotely mounted without the need for any cables because of its wireless operation The battery pack provided is Detcon s plug in Smart Battery Pack which provides an output of 12VDC See Figure 4 The battery pack consists of rechargeable Lithium Ion batteries and is equipped with integrated safety electronics that include fuel gauge voltage current and te
9. detcon inc DETCON MODEL SW AV1 DV1 Hazardous Duty Class I Div 1 Multi tone Alarm Station Operator s Installation and Instruction Manual DETCON Inc 4055 Technology Forest Suite 100 The Woodlands Texas 77381 Ph 281 367 4100 Fax 281 298 2868 www detcon com detcon Inc SW AV1 DV1 This page left intentionally blank SW AV1 DV1 Instruction Manual ii detcon Inc SW AV1 DV1 Table of Contents 0 AA su sesdsensoestsosssesdsusssessvesesess 1 1 1 Strobe Horn Ala a ch Sho ee ha cs Hees 2 1 2 Smart Battery Pack a A as nels la ee a et 2 1 3 Quad Battery Charger Optional orsi eoin eiea E E AEAEE RETEA EAN E a iae 3 1 4 RXT Series Wireless Transceivers ccccccccccccssssessecccccecessescsseseccessceususscececccsssuseusececesseseuausaeeeeceseeaes 4 A SIN A A et OAA POE E A OEE AS E E 5 30 OperatiOMicicccccsccciecccsscccecsecessedssoasvoctsvecsdcnsevessssssecscgavees O O 7 AiO TRAPS A NN 8 AS AA ase eos eetos o s tosite seotuse eseo N NES eot ee tooo stuiee Nereo a Toon Sorso resse raas soso ooi 9 60 IATA AAA AEE E A EE EE ES E EA E S ES 9 TO SO sucevecdsGeenesssuecsandeseccssccssebaseessactsdeevesepeessecsieunsesecassetess 10 Table of Figures Figure 1 Basic C1D1 Wireless Alarm Stations 0 ccs cececssecsecesecesceeseeesneesseesseecsaecsaecsaecsaecaecsseeeaeeeaeeeseeenaeenaes Figure 2 Wireless Interconne ct PCA Iron iniaeeai dedo toledano sobs eel canes soca jack ste tabernas apre seeped stated
10. has up to 32 possible settings for use in different configurations The default settings of the horn are factory set The default setting for the Horn is 21 SW1 and SW2 set to 01000 To change the setting of the horn remove the horn side of the alarm enclosure and set the dip switches according to the Sound Signals Table SW1 and SW2 are used to set the horn sound signal SW1 and SW2 should be set the same to insure the correct sound signal swi 45 sw2 nu 1 1 onli switches Strobe Horn Combo Alarm PCA Power and control wiring on other side of board H LK2 LK Figure 7 Alarm switch location To gain access to the switches remove the shroud over the horn by removing the three Philips head screws Remove the 4 Allen screws from the horn side of the enclosure and carefully slide the horn out of the enclosure Set the switches as desired and reverse the process to re assemble the horn Table 1 Sound Signals Sound Signal Frequency Repetition Switches Special Applications Rate SW1 Sw2 1 Alternate two tone 800 1000 0 5 11111 Fire Alarms 2 Alternate two tone 2500 3100 0 5 01111 Security Alarms 3 Alternate fast two tone 800 1000 0 25 10111 Increased Urgency 4
11. mperature monitoring circuits This smart circuitry continuously monitors the battery s condition and reports critical status information to the wireless transceiver The battery pack is designed to plug onto an 8 pin Beau connector on the terminal board and should not be exposed to outside elements without being housed and protected Only Detcon products specifically designed to utilize these battery packs should be used Operating periods before recharge can be as long as 2 3 months and battery life can be up to 5 years before battery pack replacement is required Improper use of the battery pack may be hazardous to personnel or the environment and will void the warranty SW AV1 DV1 Instruction Manual Rev 1 1 Page 2 of 10 detcon inc SW AV1 DV1 Figure 4 Smart Battery Pack NOTE The Wireless Alarm Station can also be powered by a customer provided external DC power source Refer to section 2 for more details 1 3 Quad Battery Charger Optional Detcon s Smart Battery Pack can be charged as needed using Detcon s optional Quad Battery Charger which can charge up to four battery packs at one time The Quad Battery Charger comes with a plug in AC DC adapter that plugs into a standard 120VAC outlet for power The DC end of the adapter plugs into the DC power jack of the charger providing 24VDC The Quad Battery Charger has four charging ports each with 8 pin Beau connectors for battery pack connection The ports and connectors are
12. s instruction manual for more detailed information SW AV1 DV1 Instruction Manual Rev 1 1 Page 4 of 10 a detcon Inc SW AV1 DV1 2 0 Installation NOTE The wireless alarm station is a precision instrument and care should be taken when handling it The Wireless AV1 DV1 Alarm Station is made to be mounted on a 2 or 3 diameter pipe Two 3 U bolts with hardware are provided for mounting The location for mounting the wireless alarm station should be carefully selected Occasional access to the unit will be necessary for battery replacement and maintenance Wireless Transceiver RXT 300 or RXT 320 2 3 Pole Mounting gt Hardware Junction Box with Battery Pack 30 5 y Strobe Horn Combination Strobe Horn Combination 16 5 Typ Figure 6 Alarm Dimensional No outside wiring is necessary for these units Once the unit has been mounted install the battery pack and the unit will begin normal operation If the unit is equipped with the RXT 320 Transceiver the Address Switch on the Wireless Interconnect PCA should be set to the correct address for the alarm station This switch is normally set at the factory If there is more than one alarm station each station should have a unique address for proper operation For more information refer to the RXT 320 manual Units equipped with RXT 300 Transceiver do not use this switch To install the battery pack insure
13. to the protection circuitry of the batter pack which prevents any overcharging issues 1 4 RXT Series Wireless Transceivers The wireless function of the alarm station is made possible by Detcon s RXT series wireless transceivers These transceivers transmit signal data such as analog 4 20mA DC or serial Modbus and can support up to 32 devices They operate at 2 4GHz and conform to non licensed radio frequency appliance usage around the world Wireless network integrity and security is accomplished using direct sequence spread spectrum wireless mesh technology Wireless applications can be as simple as a single field device communicating with a host controller or any number of field devices forming a network of subscribers Every device in the network is capable of functioning as a router and repeater for all other devices in the network This means that subscribers can hop through neighboring devices to communicate with each other thereby widening network access points This unique and innovative technology is designed to create a robust network that automatically routes around congestion and line of sight obstacles while improving throughput as subscriber device density increases Detcon offers two models of the wireless transceiver Model RXT 300 and Model RXT 320 Both models are functionally similar with one major difference the RXT 300 provides a network wide control processing capability whereas the RXT 320 does not Refer to each model
Download Pdf Manuals
Related Search
Related Contents
GRSIM User`s Manual Frigidaire CMSF-10310 Instructions / Assembly Page 1 Page 2 Page 3 けで ル操作プ ハンド きます。 簡単に隣接条 Sytema PTW Manual.cdr Manual de instruções Yosemite Home Decor ZEPHYR-ORB Instructions / Assembly OK LIGHTING OK-5112H Installation Guide Samsung CE2977N Manual de Usuario Sony ST-JX411 User's Manual Description of the appliance Copyright © All rights reserved.