Home
User Manual - Radioterminal
Contents
1. AA unt Pot l B Ch Count Port 2 Net Sin AAF Neat al Sim SR System Status i B Ch Status compot Ay Network H M a ISDN Line Legend February 2006 Page 30 32 DTT BRI Gateway Click inside a port block to view the antenna reception quality of surrounding antennas The Antennas monitoring window will popup BRLAysiem vei 7 6 1 Total calla minute 27 14_ z i i System Status TN ieee Spies A Legend Com Port Network ISDH Line Collapse all Expard all gt Connected proes mamon e LAC Location Area Code e Cl Cell ID e MCC Mobile Contry Code e BSIC Basic Station Identity Code e BCCH Broadcast Control Channel e RSSI Receiver Signal Strength e LED modes o Ared LED indicates there is no connection o A yellow LED indicates there is a connection but no data transfer o Agreen LED indicates transfer of data February 2006 Page 31 32 DTT BRI Gateway Call Reports Press CallReport to review the call report DRI Sycicin yer 2 6 9 ease u Disconnect Main System Call Report B Ch y Port Check every i F _ PROJECTS NEW PROJECTS NEW PROJECTS lt PAI_ Export every Format Access C CSV C WML F nelude heeds OUT Voice 899720201071 676 0i D 00 00 09 OUT Voice 899720201074 01 01 00 00 1 0 IN Voic
2. assigning of B channels to in house phones and the allocation of calls to DTT Series BRI Gateway ports February 2006 Page 24 3DTT BRI Gateway These settings are made in the B channel Port window Press B Ch Port tg open the B Channel Port setup window This window is divided into four frames as shown on the following page BRISystem ver 2 6 1 2 Disconnect Exit FPort Frelres Setting Port number B Channel prefix Stock T By Prefixes V Port 1 B ch 01 1 Static Wo Port 2 B ch 02 2 C Cyclic C Random Wailing time of free port 0 250 s0 0 1 Sec B Ch Setting Pretives table M B Channel Outgoing Number No Prefixes Clear Prefixes table x B Ch 1 ey a v o a ff B E Ch 2 ir 2 050 052 23 24 Retesh EP white data complete successful 00 01 21 00 01 01 February 2006 Page 25 32 DTT BRI Gateway Chapter 6 1 B Channel to In house phone number association Assign office in house phone number extensions to B Channels B Ch Setting 6 Channel Outgoing Number WO B Ch 1 6001 B Ch 2 E002 In house phone numbers are assigned in the lower left frame Outgoing number refers to internal telephone numbers For example 6001 and 6002 For each channel that extends to a phone simply mark the check box of it as shown in the screen snapshot above Chapter 6 2 In house phone number and GSM association This prefixes table setting frame is for
3. associating prefix numbers of the different GSM operators to a channel number appears on the left 1 2 This means that a port that associates with this channel can generate calls only to GSM numbers having the defined prefixes Another option is to define a port association to channel 0 which means that the port can be used to generate calls to any GSM operator with no limit but the SIM cards limit Prefines table Clear Prefixes table Blue GSM network prefixes L 1 os 052 053 pa Red GSM network prefixes L a 051 oe a ae No Prefixes Chapter 6 3 Network Prefixes Settings The prefix table is in the lower right corner of the B channel Port window This table is used to direct calls from the DTT Series BRI Gateway to GSM networks through the appropriate SIM For example e f GSM network Blue includes telephone numbers that start with 051 052 and 053 then these prefixes could be listed in row 1 of this table e f GSM network Red includes telephone numbers that start with 061 062 063 and 064 then these prefixes could be listed in row 2 of this table If the Prefix allocation mode Is selected as described below then the DTT Series BRI Gateway checks the prefix of the outgoing numbers and sends dispatches phone calls through the appropriate SIM This helps ensure the lowest call rate possible for the user February 2006 Page 26 32 DTT BRI Gateway Chapter 6 4 Port Allocation Mode Setti
4. build 10 i Be ISDN Time The ISDN window opens This window defines settings in the E1 line between the switching unit and the ISDN card Enter specifications as described on the following page Ensure that settings are in conformity with settings in the switching box To define ISDN settings press February 2006 Page 20 32 DTT BRI Gateway Continue Settings in the ISDN configuration window as follows BRI System ver 2 6 1 9 asa Sevrg Disconnect System Call Report B cod Debug Monitor ISDN Setting System version ISM version 56 245 Eose Network access INT 8 S t C SY Local address Between 1 16 digits Connection mode Point To Point v alah emg Wa digits Incoming Calis Overlap x Local sub address Between 1 4 digits fo Country Code Type of number Between 0 7 en l ISDN Version eae Numbering Plan indentification E Between 0 15 Refresh Write ISDN Setting System time setting Date dd mimn sy 0120172000 E Time hh lt mm 00 00 00 Day Sunday Set System Time E Connected 01 17 58 00 01 01 O Owu 1 The control PCB has an EEPROM containing master card software Enter the version of the master card software in System Version 2 ThelSDN module is a small PCB connected to the master PCB The ISDN module has an EEPROM containing ISM software Enter the ISM version in the ISM version box 3 Select Point to Point t
5. of purchase by the original purchaser In case of defects of materials or workmanship DTT will replace it free of charge This warranty applies to hardware software but does not include SIM Cards This warranty will not be honored if the device has been mishandled in any way We hope you enjoy our product and we will be happy to receive any comments you may have This will enable us to improve our products and the Technical Support that we give to every customer February 2006 Page 3 32 DTT BRI Gateway Table of Content Gening Star Caisse datos ca EAEE AEE baw aloware auimedd dled EE E oe 5 Check VOUT packag lems rossen E AEA EAE 7 The Dual Cell BRI Gateway Solution Overview cccceceeceeeeceeeeeeeeeeeneneeeeasnees seen ees eeeeeaee eases neesnaeaeesnenseaeesnsnsnaeananngegs 8 Chapter 1 Installing SIM Cards and Connecting the Cables ccccccceeeeeeeeeee esses eeeneneeeeeeneeseeeeeaeesesesnaeaeeensesnsenes 9 Chapter 2 Installing the Manager Application cccccccececeeeece sence ee cnee eens sees seen nee eaee seen nee ease ceeeaeas sane ceeeaeaseaeananas 11 Chapter 3 Configurations with the BRI Management application 00 ce cecceeeee eee ee eee eeeeeeeeeceeeeseeeaeneeaeeeeaenenanes 13 Chapter 4 Porn and SIM CUMING S sensio a a E a E a a 15 Chapter 4 1 Define Dial Settings for Each Port s assansnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnne 15 C
6. Cell BRI Gateway IP RS 232 BRII Management MS Windows Application An MS Windows PC Laptop shall be used to operate the BRI Management MS Windows application The BRI Management MS Windows application is used for configuration monitoring and usage reports generation via RS 232 Comport PC COM For monitoring reports and statistics it is recommended to keep the management application connected to the BRI gateway The Management Application provided is mandatory for configuring the BRI gateway operation and optional for monitoring and reports However it is highly recommended to leave the management application always connected to the BRI for on line monitoring reporting and performing configuration changes as required The BRI Management MS Windows application provides the following functionalities e Configuration Connections ports channels SIM cards and operational modes can be configured e Monitoring Call operations can be monitored from the Management Application Therefore you may wish to leave a computer permanently connected to the Multi Cell BRI system all time e Reports and statistics Calls report calls history antenna reception status logs and more can be generated for analysis in standard MS Windows data processing tools such as MS ACCESS and MS EXCEL February 2006 Page 8 32 DTT BRI Gateway Chapter 1 Installing SIM Cards and Connecting the Cables First you shall install the GSM SIM c
7. DTT BRI Gateway ISDN B RI to GSM Gate way Version 6 2 1 User Manual Connecting Landline Phones to Cellphones directly February 2006 Page 1 32 BRI Gat eway Usage Warnings 1 High voltage transients surges and other power irregularities can cause extensive damage It is the user s responsibility to provide a power protection system 2 Itis the user s responsibility to install operate and maintain the system in accordance with all applicable codes regulations and safety measures Trademark and Patents All trademarks patents and copyrights apply General Manual Notes Without BRlor notice and without obligation the contents of this manual may be revised to incorporate changes and improvements Every effort has been made to ensure that the information is complete and accurate at the time of publication Nevertheless DTT Itd cannot be held responsible for errors or commissions February 2006 Page 2 32 DTT BRI Gateway Dear Customer We thank you for purchasing our DTT BRI Gateway The information in this manual does not constitute a warranty of performance although the information has been compiled and checked for accuracy by DTT Ltd All our products are developed and produced by experienced engineers who aspire to achieve customer satisfaction utility value and reliability of products Warranty Policy The Dual Cell to BRI Gateway product you have purchased is under warranty of 12 months from the date
8. ards and later connect several cables and install the antennas to the BRI Gateway Installing the SIM Cards Insert the SIM cards into the Dual Cell as follows e On the bottom side of the Dual Cell open the SIM chambers by sliding the cover panels sideways e Open the SIM slots as follows Position the back of the Dual Cell as shown below grip the clip in the chamber and slide the clip toward yourself about cm e While the clip is slid toward you pull it upward and outward The end closest to you is on a hinge Insert the SIM so that contacts are facing down close the clip and close the cover panel February 2006 Page 9 32 DTT BRI Gateway Connecting the Cables e 12v power cable The device power cable is supplied with a power supply converter for covering all main voltage electricity services in the world Connect a 120V North America or 240V Europe power supply cable to the BRI Cell gateway e ISDN cable The regular ISDN cable is used to connect the system to the PBX serving the Office landline phones For the regular ISDN cable connect the ISDN line from the telephone switching unit in your office to the Multi Cell unit Connect the ISDN line to the RJ 45 socket labeled ISDN in the front of the Multi Cell unit as shown below e PC Comport RS 232 cable The RS 232 serial connection cable between the BRI and the PC with the BRI Management Application installed e Antenna Cables Connect the Antenna
9. ay ESt SOQ00001 Port 1 SIM 1 Setting Refresh Fredia AN Code 1 80k e Caller ID By network f Auto BECH Lock C BECH Lock 7 999 512 895 0 Disable i BECH Random RSSI select fom list Timer 0 250 0 Disable Operate ID 1 533339 O Any BCCH Lock Write SIM Setting Collapse all Expandall E Wite data complete successful 0017 17 00 01 01 Refer to the port and SIM setup window shown in the previous chapter The SIM can be locked permanently to a specific channel or it can be set to be locked temporarily to the channel with the strongest signal in the time of call generation To assign the SIM permanently to a specific channel in the BCCH Lock box enter a channel number between 1 124 or 512 885 inclusive To set the channel lock so that the SIM temporarily locks to the channel with the strongest signal at the time of the phone call enter 0 in the BCCH Lock box February 2006 Page 19 32 DTT BRI Gateway Chapter 5 ISDN and Time Settings This chapter describes the required and optional ISDN settings as well as the related time setting Chapter 5 1 ISDN Settings Each DTT Series BRI Gateway has a master printed circuit board PCB The ISDN card is a small PCB mounted on the master PCB The ISDN card is between ports in the DTT Series BRI Gateway and the external phones PBX switching unit COM Port ISDN rs ISDN Synchronization BRI Winner V 2 6 3
10. dvanced l mz USEIS 6 Select Complete and click next The Begin Installation window will open BRI v2 5 1 Ins allShield W izard EJ Ready to Install the Program i ae The wizard is ready to begin installation Click Install to begin the installation IF vou want to review or change any of your installation settings click Back Click Cancel to exit the wizard Installshield ai _ 7 Click Install The BRI Management application installs itself Wait all steps till a completion message will appear February 2006 Page 12 32 DTT BRI Gateway Chapter 3 Configurations with the BRI Management application After installing the manager application launch it and define the COMport to which the Dual Cell is connected to Launch the BRI Management application and define the Type of Connection between the management PC and the BRI Gateway After installing the BRI Management application launch it and define the Type of Connection between the PC and the BRI Gateway as described below PRI 1 Launch the BRI Management by pressing tees your PC desktop or by pressing Start gt Programs gt DTT gt BRI Manager The BRI Management application window will open AR System yer 2 6 4 Baggy Comat Main System Call Report B ch Port 4 Maribor Ext Port 1 Port not found CDMA Phone mmber Min Digis Belveren 2 7 Max Digts Belwesn 5 32 Inter ag
11. e 899720201072 0525974965 06 10 05 17 14 Voice 039720201072 0525974566 07 10 05 08 42 Voice 899720201072 0525974366 07 10 05 08 46 Voice 899720201072 0525974966 07 10 05 09 47 07 10 05 09 47 Voice 699720201072 05259745366 07 10 05 09 48 07 10 05 03 45 Total records 7 aL Export to Access p csv 1 xme Auto downloading is disable E Connected 9 03 45 01 01700 February 2006 Page 32 32 DTT BRI Gateway
12. ebruary 2006 Page 5 32 DTT BRI Gateway e Mandatory Tasks Port ISDN Channels Phone Numbers Configurations In order to operate the system ports and use the installed SIM cards and the ISDN connection a certain setups should be performed Refer to the following chapter that match your configuration needs Chapter 4 Port and SIM Settings Chapter 4 1 Define Dial Settings for Each Port Chapter 4 2 Define Type of Dialed Numbers Dispatch Mode Chapter 4 3 Define Minimum Amount of Time between Outgoing Calls Chapter 4 4 Define SIM Specifications Chapter 4 5 Define the Channel Lock Chapter 5 ISDN and Time Settings Chapter 5 1 ISDN Settings Chapter 5 2 Time and Date setting Chapter 6 B Channel Port Association e Optional Task Monitoring and reports The BRI Management MS Windows application enables you to monitor calls in real time It is recommended that the management application PC will be kept connected to enable fast response for configuration and continues monitoring of the system The BRI Management MS Windows application enables you to generate call reports and export the report files for additional analysis It is recommended that the management application PC will be connected via IP to enable flexible and continues connection with the monitored system Refer to Chapter 7 Monitoring Calls and Reports For getting the most updated Product Info on the Web February 2006 Page 6 32 DTT BRI Gateway Check your pac
13. eeeeeeeeeeeee eens eeeeeneeen eee snene eases nsnsneeaeasnsesesneeasesesesneteeeeasesnananas 26 Chapter 6 4 Port Allocation Mode SettingS ccccececccseeeeeeeeneee ee eee eens ee eeeeeeses ee eee ee eeeeeseeeeeesnensnaeaeasnsaeeaeaensesnaeneasanes 27 Chapter 6 5 Make Port Prefix SettingS ccccccccceeeceeeee sence cee ee eee ene n en ne eens nena e nese SEAS e OSes Ones eeeeeeeeeee 28 Chapter 7 Monitoring Calls and Reports ccccccccccceceeeeeeeee cena ee eecenene eases eases eases ee eeenseeeaseseaeasnaeesnaeeenaeaeeseaeasnenanas 30 February 2006 Page 4 32 DTT BRI Gateway Getting Started DTT team is glad you have chosen to use the DTT s Dual Cell GSM to BRI gateway for your needs we will do our best to make your installation efforts as well as day to day configuration and monitoring tasks be pleasant tasks as possible We wish you a smooth operation while greatly saving your office mobile phone calls This chapter is your Map for installation configuration and monitoring tasks and includes a short explanation on each stage as well as references for more elaborated explanations drawings and examples in the following chapters The following is a list of tasks you shall perform where you shall go over it sequentially or skip tasks that are optional and not required for your current needs It is advised that you will use the following tasks as your check up Do To List We advise that you will make a print this c
14. efine the activation time for the SIM Press the Time Table Tab The Time Table Tab with SIM Spec definition window will appear Now you can define the main SIM definitions and Time range and days that SIM will be enabled Enter SIM specifications l Enter the SIM phone number in the Phone number box 2 Enter the PIN code of the SIM in the PIN CODE box 3 Select a caller identification option in the Caller ID list o To enable the GSM network to set caller ID standards select Network o To enable identification of the SIM select CLIR Suppression o To disable identification of the SIM select CLIR Invocation If desired set an airtime limit at Maximum Number of Call Minutes Set Hours and Days that SIM is Active in the Time Table tab define hours and days that the SIM is active Days can be divided in up to four intervals 1 Select an interval 2 Enter the hours of the interval 3 Select days that this interval will be activated Select days of deactivation in the row BRI System Wer 2 en Port 1 SIM 1 Setting Refresh Predial PIN Code Oi Caller ID By network inet 0000 to 259 _ N M inz ing LO to Se wie SIM Sietting Colapse all Expand all EP Write data complete successful 00 06 36 00 01701 K G A wm n February 2006 Page 18 32 DTT BRI Gateway Chapter 4 5 Define the SIM Channel Lock BRISystem ver 2 6 1 Mai aba Prod ets B Ch Port Debug Monitor Exit af Gatew
15. g unit 9 Press Write ISDN Setting to send the ISDN settings to the Dual Cell unit Note The following three filed boxes in this window are only displaying the existing settings e Network access this box displays the type of telephone network connection NT or TE e Country Code this box displays the default country code setting EurolSDN e ISDN version this box displays the default ISDN version EurolSDN February 2006 Page 22 32 DTT BRI Gateway Chapter 5 2 Time and Date setting In the bottom part of the ISDN window set the date time and day Then press Set System Time to send the settings to the DTT Series BRI Gateway February 2006 Page 23 32 DTT BRI Gateway Chapter 6 B Channel Port Association Communication through a Dual Cell is performed via ports on one end and B channels_ on the other end Each Dual Cell has two ports Each port extends to a GSM module containing a SIM The GSM module communicates to the GSM network On the opposite end of the Dual Cell two B channels_ communicat to the switching unit GSM Cellphone Landline Incoming calls from switching unit to Phone ISDN card minimum digits example 050 787 4444 10 digits RJ 11 Outgoing calls from ISDN card to switching unit maximum digits 4 example 6001 4 digits GSM Module ISDN BRI 2 x B Channels Mapped into 2 operating GSM SIM Cards DTT Dual Cell BRI Gateway This chapter explains the
16. hapter 4 2 Define Type of Dialed Numbers Dispatch Mode annsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnennnnn nnna 16 Chapter 4 3 Define Minimum Amount of Time between Outgoing Calls ccccceeeeeeeecee eee eeeseeeenaeeeeeeeeneeaeeeeseees 17 Chapter 4 4 Define SIM Specifications ccc cccee cece eee ee eee ee eee eee ee ceeeneneeesne eases ease sea eeenseeensneeasaseasesnanasneeaesseanasnanas 18 Chapter 4 5 Define the SIM Channel LOCK siictvscuicorccceuee conosctousenmcscrebeseucdudatbeminssuesaddavendedsincdessiede ese vedsasecandesetasedeadoavelcs 19 Chapter 5 ISDN and Time Settings scicscccdcietatieuecncmatcmonencimentatecescnembanstionaandatnanrveenmnedsdeneididansctwiwed AA a aia aa 20 CRFS k ODN SENOS eanan iE EE AAE EA EEE EEE Ei 20 Chapter 5 2 Time and Dat settling scncincsccedetcnnesedianndssondecseuniseedaetnemeiswsneasusantscnihen duiehansaadis qnemseinniealenaimednniasiunntaunasmneneres 23 Chapter 6 B Channel Port Association s sansnsnnnnnnnnnnnnnnnnnnrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nunen nanen nnn nnnne mnnn nnmnnn 24 Chapter 6 1 B Channel to In house phone number association ccccecc ee eee cece eee ee eee ceeeeeneeaeeceeeneeaeaeeeeaenenanaenananes 26 Chapter 6 2 In house phone number and GSM ASSOCIAtION cccccee cee ce eee e nescence eens cee eeeeaeaeeeeesneeaeasneeesneeenenaes 26 Chapter 6 3 Network Prefixes SettingS ccccccccceeeeee
17. hapter and put notes on each stage when completed e g V mark when done Mandatory Check that all Package items delivered in your package Refer to Check your Package Items chapter for checking that all items that should be in your package Mandatory Install The Management Application On the PC Laptop allocated for the system management install the MS Windows Management Application with the provided CD Refer to Chapter 2 Installing the Manager Application chapter for all items that should be in your package Mandatory SIM cards installation and connections Install SIM Cards Install Power Supply and 12v Power Cable Install Antennas Install ISDN cable Install RS 232 Comport cable for PC serial COM port connection O O O O Refer to Chapter 1 SIM Cards Installation and Cables Connecting for specific and detailed guidelines Mandatory General configurations In order to operate the system mandatory basic setups should be performed in using serial RS 232 via PC COM port Refer to Chapter 3 Configurations with the BRI Management application Mandatory system configuration Use the RS 232 connection and BRI Management MS Windows application You can use this method for later day to day management for monitoring and reports of the BRI gateway activity Gateway system via IP is highly recommended as you can have the management done remotely from the system via internet connection F
18. it paua Belver 1 200 Send complete Choore from list Intercell Timer in Second i Se BO T ET 324011243 peat SRG J TT Colapse all Expara all 2 Disconnected lane February 2006 Page 13 32 DTT BRI Gateway Select Connection Please select the number of com that you want to connect and press ok to continue COM 1 Cancel 3 Select the Com Port to which the DTT Series BRI Gateway is connected to These options described in the following sub chapters After installing the Manager and defining the port connection define port and SIM settings as described in the following chapter After establishing communication between the auxiliary computer and the DTT Series BRI Gateway define groups of telephones in your office as described in the following chapter February 2006 Page 14 32 DTT BRI Gateway Chapter 4 Port and SIM Settings This chapter describes port dial settings as well as timetables and channel locks for SIM cards used Chapter 4 1 Define Dial Settings for Each Port Press Main Setting to define dial settings for each port The Port Setting window opens To define port dial settings click a port and proceed as described on the following pages BRI System ver 2 6 1 GSM Port 1 Setting Min Digits Between 2 7 Max Digits Between 5 32 Inter digit pause Between 1 200 Send complete Choose trom Es Intercall Timer in Second Write Port Sitting Cola
19. kage Items Please verify your package contains the following components Some were ordered specific before installation e Main Hardware Device The Dual Cell BRI gateway e 110 220V 50 60Hz Electric Power converter to 12V with cables supplied e Software Installation CD Installation kit of the Dual Cell Manager CD for MS Windows Management Application this User Manual file and additional auxiliary utilities e 2 GSM Antennas To be installed to the BRI gateway e RS 232 Serial PC COMport connection cable RJ 45 to RS 232 COM we ll be referred as Comport cable in this manual February 2006 Page 7 32 DTT BRI Gateway The Dual Cell BRI Gateway Solution Overview The Dual Cell BRI gateway that will be referred as the BRI gateway in short is a device that connects your desk phones directly to cellular phone networks This gateway completely bypasses the local landline telephone company Two desk phones can be connected to each Dual Cell gateway via a Phone switching unit often a PBX type switch Each port in the Dual Cell gateway contains a SIM A SIM is a smart card that contains information such as the GSM network and phone number billing and verification Id The Dual Cell can be configured to direct phone calls through the most economical SIM One Location in the World Another Location in the World T j all eon a E a if K uS a te GSM GSM Cellphones Base Stations GSM Base Stations Cellphones Dual
20. ngs Allocation Mode p Cyclic C Random The manner in which a phone call is directed to a port is determined in this frame e f By Prefixes is selected then the DTT Series BRI Gateway directs a call through a port according to the defined prefixes of the telephone number prefix Using the example above If a user dials 051 333 4444 the phone call would be directed as 051 GSM extension If one GSM network is designated for both ports then select the manner in which ports will be selected o Cyclic indicates that ports will be selected in a cyclic manner for example if the first call is via port 1 the following call will be directed through port 2 the third call will be directed through port 1 and so forth o Random indicates that ports will be selected at random for example port 2 port 2 port 1 port 2 port 2 port 1 port 1 and so forth e f Static is selected each ISDN B channel and its respective telephone is linked permanently to a port as defined in the prefixes table frame An ISDN B channel and its respective telephone can be switched as described below February 2006 Page 27 32 DTT BRI Gateway Chapter 6 5 Make Port Prefix Settings PortPretizes Setting Port number 8 Channel prefix Stock W Port 1 E ch 1 W Port 2 B ch 27 2 Port prefix settings are made in the upper left frame of this window and associates channel to a prefix entry of GSM operator extensions If Prefix is set to 0 the
21. o Point or Multipoint in the Connection mode box 4 Inthe Incoming Calls box select the interface of incoming calls from the switching unit to the ISDN card Overlap pulse or In Block packet in conformity with the setting in the switching unit e f Overlap is selected then proceed to step 5 e If In Block is selected then enter a value in a ring signal parameter The box labeled Minimum number of called number digits from ISDN is a ring signal parameter This parameter determines when a ring signal will be initiated in calls coming from the switching box to the ISDN card Enter the minimum number of digits of incoming phone numbers in this box for example 050 787 444 10 digits February 2006 Page 21 32 DTT BRI Gateway 5 If you have more than one DTT Series BRI Gateway on site enter the address of each DTT Series BRI Gateway unit in the Local address box This entry can accept number between 1 and 20 digits 6 If you have sub addresses of DTT Series BRI Gateway enter the sub address of each DTT Series BRI Gateway unit in the Local sub address box This entry can be between 1 and 4 digits 7 Inthe Type of Number box select the Type Of Number TON of calls from the ISDN card to the Switching unit as defined in the switching unit 8 The Numbering scheme protocol from the ISDN card to the switching unit is set at Number Plan Identification NPI Set this parameter as defined in the switchin
22. phone connected to the port of the channel can call to any GSM operators the SIMs support with no limit 1 Check a port to activate it 2 Assign a prefix group numbers to ports Using the above example if you have placed a SIM of GSM network Blue in GSM port 1 and prefix group 1 includes prefixes of the Blue network then enter 1 in the prefix column in the row of Port 1 3 If you want ports permanently linked to B channels and you want to change the order of connections proceed as follows a Click a cell in the B channel column and drag the cell to the Stock column PortPretizes Setting Port number 8 Channel prefix Stock i Port 1 B ch 1 W Port 2 2 EB ch 2 Sei ee b Click the remaining cell in the B channel column and drag it to the row of the desired port PortPretises Setting Port number amp 8 Channel prefix Stock W Port 1 1 W Port 2 B ch 1 2 B ch 2 February 2006 Page 28 32 DTT BRI Gateway c Drag the cell in the Stock column to the desired position in the B channel column PortPretizes Setting fas Port number 8 Channel prefix Stock W Port 1 E ch 7 W Bort 2 B ch 1 2 February 2006 Page 29 32 DTT BRI Gateway Chapter 7 Monitoring Calls and Reports This chapter explains how to monitor calls and review reports Monitoring Calls To monitor calls press The monitor screen opens Taa Monitor Gateway Monitor a Version of slave pagam uuu 061005 _ USE
23. pse al Expand all amp Connected 01 03 25 00 01 01 February 2006 Page 15 32 DTT BRI Gateway Chapter 4 2 Define Type of Dialed Numbers Dispatch Mode You can define manual or automatic dispatch Select the mode In which telephone numbers are dispatched to the GSM network e To dispatch phone numbers manually in the Send Complete list select HASH In this mode after you dialed all digits of a phone number press to send the phone number e To dispatch phone numbers automatically in the send complete list select OMIT Then set three additional parameters a Define the length of phone numbers that will be dialed from the port within a range 1 Inthe Min Digits box enter the number of digits of the shortest phone number that will be dialed from this port li Inthe Max Digits box enter the number of digits of the longest phone number that will be dialed from this port b Define the Inter Digit Pause This parameter defines a waiting time after a digit is pressed before the number is automatically dispatched to the GSM network If this parameter is set too low then incomplete phone numbers may be dispatched if the user pauses briefly while dialing If this parameter is set too high then users would have to wait a long time before a number is dispatched The inter digit pause is activated after the minimum number of digits have been dialed In many situations two or three seconds may be appropriate for thi
24. s parameter Each unit of this parameter is 50 milliseconds For example to set an inter digit pause of 3 seconds enter a value of 60 in this box 60 50 milliseconds 3 000 milliseconds 3 seconds When a port is set to auto dispatch phone numbers after the user has dialed the maximum number of digits or when an inter digit pause has occurred then the number is dispatched automatically February 2006 Page 16 32 DTT BRI Gateway Chapter 4 3 Define Minimum Amount of Time between Outgoing Calls Setup the minimum amount of time between outgoing calls in the Intercall Timer box Set this parameter according to limitations of the GSM network In many situations two seconds may be an appropriate value for this parameter Define a Period Where SIM Time Limitations will be restored In the Day of restore call limit box enter the number of days desired to define a period where SIM time limitations will be restored SIM time limitations are defined in the Maximum Number of Call Minutes box in the SIM Settings window After making port settings you MUST press Write Port Setting to send the settings to the DTT Series BRI Gateway unit Then make settings for each SIM as explained in the following section February 2006 Page 17 32 DTT BRI Gateway Chapter 4 4 Define SIM Specifications In order to define a specific SIM setting you shall point on the specific SIM in the Port SIMs tree on the Left side of the Main screen First we will d
25. s via antenna cables as shown below DISCOVERY telecom BRI Winner V 2 6 3 build 10 February 2006 Page 10 324T BRI Gateway Chapter 2 Installing the Manager Application Before operation configuration settings must be made in the DTT Series BRI Gateway Configuration is done in an auxiliary computer Configuration is done in an auxiliary PC with the BRI Management MS Windows Application provided for MS Windows operating system Install the BRI Management application into an MS Windows PC 1 Insert the BRI Management installation CD disk into the CD drive of the PC 2 In Windows Explorer navigate to the installation CD drive Install BRI v2 5 1 q Setup exe installshield Software Corpora A 3 Double click The Installation me will open to install the BRI Management Application BRI v2 5 7 InstallShield Wizard Welcome to the InstallShield Wizard for BRI v2 5 1 The InstalShveld Wizard vali install BAI v2 5 1 on yow computer To continue click Next February 2006 Page 11 32 DTT BRI Gateway 4 Click Next 5 The Setup Type window will open BRI v2 5 1 Installshield Wizard B f Setup Type Select the setup type to install Please select a setup type G Complete PLE All program features will be installed Requires the most disk space B i E an i a i Bai Custom L Select which program features you want installed Recommended for a
Download Pdf Manuals