AiCOM-5012 User Manual

image

Contents

1. 39 System Port Profile Port Serial Setting Port Serial Configuration Local TCP Port 4000 Port Profile SOERA Mode Command Port 4001 Mode Serial to Ethernet Management Flush Data Buffer After 0 ms Save Reboot Delimiter Hex 0 ff 1 00 2 00 3 00 4 00 Mode Ethernet to Serial Flush Data Buffer After 0 ms Delimiter Hex 0 ff 1 00 2 00 3 00 4 00 Apply Figure 5 29 Port Profile MICROSENS GmbH amp Co KG MICROSENS The following table describes the labels in this screen Label Description Serial to Ethernet Flush Data Buffer After The received data will be gueued in the buffer until all the delimiters are matched Whenthe buffer is full 4K Bytes or after flush S2E data buffer timeout the data will also be sent You can setthe time from 0 to 65535 seconds Delimiter You can define max 4 delimiters OO FF Hex for each way The data will be hold until the delimiters are received or the option Flush Serial to Ethernet data buffer times out 0 means disable Factory default is 0 Ethernet to serial Flush Data Buffer After The received data will be gueued in the buffer until all the delimiters are matched Whenthe buffer is full 4K Bytes or after flush E2S data buffer timeout the data will also be sent You can setthe time from 0 to 65535 seconds Delimiter You can define max 4 delimiters OO FF Hex for each way The data will be hold until the deli
2. Password Changed When password of device changed a notification will be sent Access IP Blocked When the host accesses the device with blocked IP addresses a notification will be sent Redundant Power Change When status of power changed a notification will be sent Redundant Ethernet Change When status of Ethernet port changed a notification will be sent DCD changed When DCD Data Carrier Detect signal changes it indicates that the modem connection status has been changed A Notification will be sent DSR changed When DSR Data Set Ready signal changes it indicates that the data communication eguipment is powered off A Notification will be sent RI changed When RI Ring Indicator signal changes it indicates an incoming call Notification will be sent CTS changed When CTS Clear To Send signal changes it indicates that the transmission between computer and DCE can proceed A notification will be sent Port connected In TCP Server Mode when the device accepts an incoming TCP connection this event will be trigger In TCP Client Mode when the device has connected to the remote host this event will be trigger In Virtual COM Mode Virtual COM is ready to use A notification will be sent Port disconnected In TCP Server Client Mode when the device lostthe TCP link this event will be trigger In Virtual COM Mode When Virtual COM is not
3. IC Refresh 3 Apply Only a Apply and Save Figure 5 7 Network Setting The following table describes the labels in this screen Label Description Using DHCP BOOTP IP Address automatically assigned by a DHCP server in your network Static IP Address Manually assigning an IP address All devices on the network must have the same subnet mask to communicate Subnet Mask on the network Gateway Enter the IP address of the router in you network Enter the IP address of the DNS server The DNS server translates domain DNS Server names into IP address Redundant When the connection between master link and LAN fails the DS can automatically switch to another LAN port within10mS and still guarantees a Switch Mode non stop connection Switch Daisy Chain support to reduce usage of switch ports Table 5 3 Network setting 18 MICROSENS GmbH amp Co KG MICROSENS PPPoE PPPoE Point to Point Protocol over Ethernet Device can use PPPoE mode to connect the Network Input the username and Password then click Connect button If the device has been connected the Link Status will become the Link up and device will get an IP address from PPPoE server Click Disconnect button to disconnect the PPPoE connection Wire PPPoE PPPoE Setting User Name Password Link Status Link down Disconnect IC Refresh 3 Apply Only a Apply an
4. Notified Items Hardware Reset Cold Start I Software Reset Warm Start I F Login Failed fz FP IP Changed jz P Password Changed ja I Access IP Blocked fis Redundant Power Changed Redundant Ethernet Changed System Log Settings Server IP Port 192 1 68 0 33 514 Using Current Host s Log Server IC Refresh 3 Apply Only a Apply and Save Figure 5 11 Notification The following table describes the labels in this screen Label Description SNMP Trap To notify events by SNMP trap Email Notification To notify events by Email Syslog Notification To notify events by Syslog Notify items Events to be notified Apply Apply current setting Apply and Save Apply and save current setting Table 5 5 Notification 21 MICROSENS GmbH amp Co KG MICROSENS Management General Security Networking DDNS Notification Management Upgrade Firmware Save Load IV Web Management Enable Goto Web Management Telnet Management Enable Goto Telnet Management V SNMP Management Enable SNMP Management Settings Community Location Contact Trap Serverl Trap Server2 Trap Server3 Trap Server4 Refresh 25 Apply ony ar Apply and Save Figure 5 11 Management The following table describes the labels in this screen Label Description Web Management Enable To
5. The following table describes the labels in this screen Label Description Encryption with SSL Use SSL to encrypt data Map Virtual COM Select a Virtual COM Name to map on Max Connection The number of Max connection can support simultaneous connections are 5 default values is 1 Idle Timeout When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed O indicate disable this function Factory default is 0 Table 5 10 Virtual COM Not allowed to mapping Virtual COM from web Service Mode TCP Server Mode In TCP Server Mode DS is configured with a unique Port combination on a TCP IP network In this case DS waits passively to be contacted by the device After a connection is established it can then proceed with data transmission TCP Server mode also supports up to 5 simultaneous connections so that multiple device can receive data from the same ser
6. MS655400X can automatically switch to another LAN port within 10mS and still guarantees a non stop connection MS655400X also supports switch mode you can use Daisy Chain to reduce the usage of Ethernet switch ports Secondly the MS655400X can simultaneously transfer data into 5 host PCs This feature can assure all critical data that saved in different host PC to avoid Ethernet break or host PCs failure MS655400X also Support the data encryption with SSL so it can assure the data transfer safely Thirdly the MS655400X provides dual redundant power inputs on DC power jack and terminal block MS655400X also provides NAT pass through function so that you are able to manage MS655400X inside or outside the NAT router It is easy for different IP domain to use MS655400X You can configure and mange the device server easily by using the windows management tool VCOM Therefore MS655400X is the best communication redundant solution for current application of serial devices Software Features 7 Redundant Dual Ethernet Ports Recovery time lt 10mS E Switch Mode Supported Daisy Chain support to reduce usage of switch ports E NAT pass through User can manage MS655400X through NAT router E PPPoE for internet connection E Data Encryption with SSL for Security data transfer m DDNS for domain name service m Redundant Power Inputs 12 48VDC on power jack and terminal block MICROSENS GmbH 8 Co KG 1 3 MICROSENS Redundant multi
7. Server 2 SNMP Server 3 SUUD Saree 4 Figure 5 3 5 1 2 Using VCOM 5 1 2 1 Explore device servers VCOM will broadcast to the network and search all available DS devices in the network The default IP address of device is 192 168 16 1 and selects the searching device you wish to use and press Add button You can set static IP address or in DHCP client mode to get IP address automatically Finally click OK button to add the device 3 VCOM Manager a anexa Eile Device Configuration Options Help T a 7 Mi veom Device Firmware x i a 4p 4 7 R Wizard Wizard Wizara Broadcast 39 nl 4 rd Pig See Bix EI VCOM Manager A 3 C alive E waning amp Device List 9 E Device List M not available E VCOM List Numbd IP address MAC Address Name Model Status fi Setup Wizard f i ab IP Collection a a Y System Log Broadcast Searching New Devices E 192 168 16 1 MS655400 MS655400X Alive Lock Cancel Clear All Add JA Alot of IPs need to be re config Your best BP choice Group IP Wizard Click here Figure 5 4a 15 MICROSENS GmbH amp Co KG MICROSENS 5 1 2 2 Configure device servers General settings This page includes the setting of device name SNTP server and Auto IP Report General Security Networking DDNS Notification Management Upgrade Firmware Save Load Model Power TH 208 E LA
8. TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP Alive Check connection is not alive the connection will be closed and the port will be freed O indicate disable this function Factory default is 0 Connect on The TCP Client will build TCP connection once the connected serial device is Startup started Connect on Any The TCP Client will build TCP connection once the connected serial device starts Character to send data Table 5 21 TCP client mode 44 MICROSENS GmbH amp Co KG MICROSENS Service Mode UDP Client Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can Uni cast or Multi cast data from the serial device server to host computers and the serial device can also receive data from one or multiple host i Industrial Ethernet Device Server Web 192 168 16 1 https 192 168 16 1 29 Google Industrial Device Server Help System Service Mode Port Serial Setting per Serial Configuration Service Mode UDP Mode oa soote Listen Port 4000 Host start IP Host end IP Send Port Management r OE 2 65535 3 65535 4 65535 Save Reboot Figure 5 33 UDP client mode 5 2 1 3 Management 45 Access IP Control Access IP Control Settings allow you to add or block the remote host IP addresses to prevent unauthorized access Ifhost s IP address
9. is in the accessible IP table then the host will be allowed to access the DS You can choose one of the following cases by setting the parameter 1 Only one host with a special IP address can access the device server IP address 255 255 255 255 e g 192 168 0 1 255 255 255 255 MICROSENS GmbH amp Co KG MICROSENS 2 Hosts on a specific subnet can access the device server IP address 255 255 255 0 e g 192 168 0 2 255 255 255 0 3 Any host can access the device server Disable this function by un checking the Enable IP Filter checkbox Firefox Go i Industrial Ethernet Device Server Web mr A 192 168 16 1 https 192 168 16 1 2 Google P A Industrial Device Server Help System Access IP Control List Port F 7 P a si hili Serial Setting Enable IP Filtering Not check this option will allow any IP to have assessibility No Activate the IP IP Address Netmask Management Access IP Control List SMTP SNMP Conf System Event Conf A Save Reboot Ga NOW ke wn Figure 5 34 Access IP SMTP SNMP Conf Email Server configuration includes the mail server s IP address or domain If the authentication is required specify your name and password There are 4 Email addresses that you can specify to receive the notification SNMP Server configuration includes the SNMP Trap Server IP address Community Location and Contact There are 4 SNMP
10. of MS655400X are shown as below 1 Screw holes for wall mount kit and DIN Rail kit 2 Din Rail kit 3 Wall Mount kit Figure 3 4 Rear Panel 11 MICROSENS GmbH amp Co KG MICROSENS Cables 4 1 Ethernet Cables The MS655400X has standard Ethernet ports According to the link type the MS655400X use CAT 3 4 5 5e UTP cables to connect to any other network device PCs servers switches routers or hubs Please refer to the following table for cable specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 Table 4 1 Cable Types and Specifications 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data Pin Number Assignment 1 TD TD RD Not used Not used RD Not used MINI OD wm HR WIN Not used Table 4 2 RJ 45 Pin Assignments 12 MICROSENS GmbH amp Co KG MICROSENS The MS655400X supports auto MDI MDI X operation You can use a straight through cable to connect PC to MS655400X The following table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin Number MDI port MDI X port 1 TD transmit RD receive 2 TD transmit RD receive 3 RD receiv
11. the buffer is full 4K Bytes or after flushE2S data buffer timeout the data will also be sent You can set the time from 0 to 65535 seconds 25 MICROSENS GmbH amp Co KG MICROSENS Force TX Interval Time Force TX interval time is to specify the timeout when no data has been transmitted When the timeout is reached or TX buffer is full 4K Bytes the queued data will be sent 0 means disable Factory default value is 0 Table 5 9 Serial settings Service Mode Virtual COM Mode In Virtual COM Mode The driver establishes a transparent connection between host and serial device by mapping the Port of the serial server serial port to local COM port on the host computer Virtual COM Mode also supports up to 5 simultaneous connections so that multiple hosts can send or receive data by the same serial device at the same time Serial Settings Service Mode Notification port Service Mode Virtual COM Mode Virtual COM Settings I Encryption with SSL Data Port 4000 Control Port 4001 Multilink Max Connections 1 v Destination Host 1 Idle Timeout g 0 65535 Seconds 7 Edit IP Port Number Map Virtual COM Alive Check 420 0 55535 Seconds Virtual COM Mode Misc COM Name Waiting for YCOM connect E ET IC Refresh 26 JE rear 2 sp ta Figure 5 15 Virtual COM MICROSENS GmbH amp Co KG MICROSENS
12. va 4 gle P A B Industrial Device Server Help TCP Server Port 4000 Idle Timeout 0 0 65535 seconds Alive Check 40 0 65535 seconds Max Connection 1 max connection 1 5 Apply Figure 5 31 TCP Server Mode The following table describes the labels in this screen Label Description Data Encryption Use SSL to encrypt data Telnet Negotiation Full Telnet command symbol compatible TCP Server Port Set the port number for data transmission Idle Timeout When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package in each defined time 42 MICROSENS GmbH amp Co KG MICROSENS interval Alive Check to remote host to check the TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 Max Connection The number of Max connection can support simultaneous connections are 5 default values is 1 Table 5 20 TCP server mode Service Mode TCP Client Mode In TCP Client Mode dev
13. 000 rQ Auto Scan g 8 Ato Sn to eQ Auto Scan o EA Auto Soan 30 Figure 5 18 UDP mode MICROSENS GmbH amp Co KG MICROSENS Notification Specify the events that should be noticed The events can be noticed by E mail SNMP trap or system log Serial Settings Service Mode Notification V SNMP Trap V Email Notification V Syslog Notification SNMP Settings Email Settings Syslog Settings Notified Items DCD Changed CTS Changed M DSR Changed M Port Connected M RI Changed Port Disconnected Email to Mail Server Mail to IC Refresh 3 Apply Only ae Apply and Save Figure 5 19 Notification The following table describes the labels in this screen Label Description DCD changed When DCD Data Carrier Detect signal changes it indicates that the modem connection status has changed Notification will be sent DSR changed When DSR Data Set Ready signal changes it indicates that the data communication equipment is powered off A Notification will be sent RI changed When RI Ring Indicator signal changes it indicates that the incoming of a call A Notification will be sent CTS changed When CTS Clear To Send signal changes it indicates that the transmission between computer and DCE can proceed A notification will be sent Port connected In TCP Server Mode when the device accepts an incomi
14. 1 2 Ready 1 Red On Power is on and booting up Red Blinking Indicates an IP conflict or DHCP or BOOTP server did not respond properly 2 Green On Power is on and functioning normally Green Blinking Located by Administrator ETH1 2 Link ACT Amber ON Blinking 10 Mbps Ethernet 51 MICROSENS GmbH amp Co KG MICROSENS Green ON Blinking 100 Mbps Ethernet Serial TX RX LEDS Red Serial port is receiving data Green Serial port is transmitting data Power Reguirements Power Input PWR1 12 48VDC in 3 pin Terminal Block PWR2 12 48VDC in power jack Reverse Polarity Protection Present at terminal block Power Consumption 4 Watts MAX Software Utility Utility VCOM for Windows NT 2000 XP 2003 VISTA which include Device discovery Auto IP report Device setting run time change no rebooting Access control list Group setting Device monitoring Serial port monitoring Log info Group Firmware update Serial Mode Virtual Com TCP Server TCP Client UDP Serial Tunnel TCP Alive Check Timeout Inactivity Timeout Delimiter for Data Packing Force TX Timeout for Data Packing Multiple Link 5 Hosts simultaneous connection Virtual Com TCP server TCP Client UDP VCOM Driver Windows NT 2000 XP 2003 VISTA Configuration Web HTTPS console SSH console VCOM for Windows NT 2000 XP VISTA Environmental Ope
15. Auto Report Interval 0 seconds Ethernet Mode Ethernet Mode Redundant Switch Apply Figure 5 23 IP configuration MICROSENS GmbH amp Co KG MICROSENS The following table describes the labels in this screen Label Description DHCP BOOTP Obtain the IP address automatically from DHCP server Static IP Address Assigning an IP address manually Subnet Mask Set the subnet mask to communicate on the network Gateway Enter the IP address of the router in you network DNS Server Enter the IP address of the DNS server to translate domain names into IP address Auto IP Report The device server will report its status periodically At VCOM gt IP collection option show the device server status The report interval is 0 indicate disable this setting default But you can set the other IP or Port Switch Mode Redundant When the connection between master link and LAN fails the DS can automatically switch to another LAN port within10mS and still guarantees a non stop connection Switch Daisy Chain support to reduce usage of switch ports 35 Table 5 15 IP configuration PPPoE setting PPPoE Point to Point Protocol over Ethernet Device can use PPPoE mode to connect the Network Input the username and Password then click Connect button If the device has been connected the Status will become the Link up and d
16. MICROSENS Industrial Device Server User s Manual MS655400X Version 1 00 Aug 2011 1 MICROSENS GmbH 8 Co KG MICROSENS Table of Content GETTING TO KNOW YOUR DEVICE SERVER 3 1 1 About the MS655400X Serial Device Server 3 1 2 Software Features 3 1 3 Hardware Features 4 HARDWARE INSTALLATION 4 2 1 Install MS655400X on DIN Rail 4 2 1 1 Mount MS655400X on DIN Rail 4 2 2 Wall Mounting Installation 6 2 2 1 Mount MS655400X on wall 6 HARDWARE OVERVIEW 7 3 1 Front Panel 7 3 2 Front Panel LEDS 8 3 3 Top Panel 9 3 4 Bottom Panel 9 3 5 Rear Panel 11 CABLES 12 4 1 Ethernet Cables 12 MANAGEMENT INTERFACE 14 5 1 VCOM 14 5 1 1 Install IVCOM 14 5 1 2 Using VCOM 15 5 1 2 1 Explore device servers 15 5 1 2 2 Configure device servers 16 5 1 2 3 Configure serial port 24 5 2 Configuration by Web Browser 32 5 2 1 Connect to the Web page 32 5 2 1 1 System 33 5 2 1 2 Port serial setting 38 5 2 1 3 Management 45 5 2 1 4 Save Reboot 49 5 3 Configuration by SSH Console 50 5 3 1 Connect to DS 50 TECHNICAL SPECIFICATIONS 51 2 MICROSENS GmbH amp Co KG MICROSENS Getting to Know Your Device Server 1 1 1 2 About the MS655400X Serial Device Server MS655400X is an innovative 1 port RS232 422 485 to 2 ports LAN redundant device server To assure the agility and security of critical data MS655400X offers many powerful features for HW amp SW redundant functions When the connection between master link and LAN fails the
17. N IP Address LAN MAC Address Version Networking 1 2 Locate On Device Name Location DeviceServer DEFAULT Using SNTP Time Server I Auto IP Report 1 Refresh Figure 5 5 General settings The following table describes the labels in this screen Label Description Device Name location You can set the device name or related information By clicking Locate On button you can locate the serial server s position Input the SNTP server domain name or IP address port and select the Time Set SNTP zone By Clicking the Get current Host button you will get your local IP and then Set Auto IP Report set the Report interval time The device server will report its status periodically Table 5 1 General settings At IP collection option show the device server status The report interval is O indicate disable this setting default But you can set the other IP or Port MICROSENS GmbH amp Co KG Security General Security Networking Access IP Table IP1 Mask Enabled IP2 Mask I Enabled IP3 Mask Enabled IP4 Mask Enabled IP5 Mask Enabled DDNS Notification Management MICROSENS Upgrade Firmware Save Load Password New Password Confirm New Password Old Password Change Password IP6 Mask T Enabled IP Mask M Enabl
18. Provider Choose the DDNS service Provider Hostname You must first apply an account from the DDNS service Provider such as www dyndns org then register with the dynamic DNS service Input the fixed hostname you got from the DDNS service Account and Input the Account and Password you have registered from the DDNS service Password Provider Check WAN IP Device will check the IP address Status at interval time you set Schedule Table 5 16 DDNS Setting Authentication You can set the password to prevent unauthorized access from network Input the Old password and New password to change the password Factory default is no password EEE E Industrial Ethernet Device Server Web M IME e 7 192 168 16 1 https 192 168 16 1 e 28 Googe Pla En 37 Industrial Device Server Help System User Authentication System Information SNTP Configuration Old Password IP Configuration DDNS Configuration New Password User Authentication Port Confirm New Password Serial Setting Management Apply Save Reboot Figure 5 27Authentication MICROSENS GmbH amp Co KG MICROSENS 5 2 1 2 Port serial setting Serial configuration System Port Serial Setting Serial Configuration Port Profile Service Mode Management Save Reboot Industrial Ethernet Device Server Web ul amp 7 192168161 htt Ema 192 168 16 1 Google 214 EE Industrial Device Server H
19. a new firmware with specified file Firmware Reboot Device Reboot the device server warm start Table 5 23 Save Reboot 49 MICROSENS GmbH amp Co KG MICROSENS 5 3 Configuration by SSH Console 5 3 1 Connect to DS You can use SSH Tool e g PUTTY to access SSH console of DS The SSH console interface is shown below Default username and password are admin EP 192 168 16 1 PuTTY E Figure 5 38 SSH 50 MICROSENS GmbH 8 Co KG MICROSENS Technical Specifications Network Interface 2x 10 100Base T X which support Redundant Dual Ethernet Ethernet or Switch Mode support Auto recover less than 10ms connector RJ 45 Protection Built in1 5KV magnetic isolation ICMP IP TCP UDP DHCP BOOTP ARP RARP DNS SNMP Protocols MIB II HTTPS SSH Serial Interface Interface 1x RS232 RS422 4 2 Wire RS485 Which can be configured by VCOM Connector Male DB9 Serial Baud Rate 110 bps to 460 8 Kbps Data Bits 5 6 7 8 Parity odd even none mark space Stop Bits 1 1 5 2 RS 232 signals TxD RxD RTS CTS DTR DSR DCD RI GND RS 422 signals Tx Tx Rx Rx GND RS 485 4 wire signals Tx Tx Rx Rx GND RS 485 2 wire signals Data Data GND Flow control XON XOFF RTS CTS DTR DSR Serial Line Protection Built in15KV ESD protection LED Indicators PWR
20. addresses you can specify to receive the notification SysLog server configuration includes the server IP and server Port This option need to use with VCOM MICROSENS GmbH amp Co KG 47 MICROSENS System Industrial Device Server E mail Address 2 E mail Address 3 E mail Address 4 SNMP Trap Server SNMP Server 1 SNMP Server 2 SNMP Server 3 SNMP Server 4 EE E Industrial Ethernet Device Server Web gt 7 192168162 https 192 168 16 2 P SMTP SNMP Configuration Serial apie l hna g SMTP Server Port 25 Management My server requires authentication Access IP Control List User Name SMTP SNMP Conf System Event Conf Password Save Reboot EHTS E mail Address 1 Help Figure 5 35 SMTP SNMP conf System Event Conf Specify the events that should be notified to the administrator The events can be alarmed by E mail SNMP trap or system log Figure 5 36 SMTP SNMP conf cee industrial Ethernet Device Server Web 7 1921681641 https 192 168 16 1 2 4 BE Industrial Device Server Help System System Event Configuration 3 Fort Device Event Notification Serial Setting x Hardware Reset Cold Start E SMTP Mail El SNMP Trap Syslog Management Software Reset Warm Start SMTP Mail E SNMP Trap E Syslog Access IP Control List Login Fa
21. available this event will be trigger A notification will be sent 48 Table 5 22 System event conf MICROSENS GmbH 8 Co KG MICROSENS 5 2 1 4 Save Reboot Industrial Ethernet Device Server Web e J 192 168 16 1 https 192 168 16 1 C S8 Google PA BD Industrial Device Server Help System Factory Default Reset to default configuration Click Reset button to reset all configurations to the Port default value Serial Setting Reset Management Restore Configuration You can restore the previous saved configuration to Device Server Save Reboot File to restore Durchsuchen Restore Backup Configuration 4 You can save current EEPROM value from the Device Server as a backup file of configuration Backup Upgrade Firmware Specify the firmware image to upgrade Firmware Durchsuchen Upgrade Reboot Device Please click Reboot button to restart device Figure 5 37 Save Reboot The following table describes the labels in this screen Label Description Load default configuration except settings of Network If you want load all Factory Default factory default you should press Reset button about the five seconds on the device Hardware restore Restore Restore the previous exported configuration Configuration Backup Export the current configuration to a file Configuration Upgrade Upgrade to
22. d Save Figure 5 8 PPPoE Setting MICROSENS GmbH amp Co KG MICROSENS DDNS The Dynamic DNS service allows you to alias a dynamic IP address to a static hostname allowing your computer to be more easily accessed from various locations on the Internet General Security Networking DDNS Notification Management Upgrade Firmware Save Load MV DDNS Enable DDNS Setting Service Provider dyndns static Hostname Account Password E H 5368 1 1879 Check WAN IP Schedule E very Hour v Start at eli Minute IC Refresh MTU EE Figure 5 10 DDNS Setting The following table describes the labels in this screen Label Description Service Provider Choose the DDNS service Provider Hostname You must first apply an account from the DDNS service Provider such as www dyndns org then register with the dynamic DNS service Input the fixed hostname you got from the DDNS service Account mand Input the Account and Password you have registered from the DDNS service Password Provider 20 Table 5 4 DDNS setting MICROSENS GmbH 8 Co KG MICROSENS Notification Specify the events that should be notified to the administrator The events can be alarmed by E mail SNMP trap or system log General Security Networking DDNS Notification Management Upgrade Firmware Save Load SNMP Trap Email Notification IV Syslog Notification Syslog Setttings
23. e TD transmit 4 Not used Not used 5 Not used Not used 6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Table 4 2 MDI MDI X pins assignment Note and signs represent the polarity of the wires that make up each wire pair MICROSENS GmbH amp Co KG MICROSENS Management Interface 5 1 VCOM VCOM is a powerful Windows utility for DS series It supports device discovery device configuration group setup group firmware update monitoring functions etc It is easy for you to install and configure devices over the network 5 1 1 Install IVCOM Step 1 Execute the Setup program click start after selecting the folder for VCOM si Installing VCOM Manager Destination Directory a y c AProgram Files COM Manager a lt Required 7056 K 5 Available 7855000 K Bowe Figure 5 1 Step 2 When installation complete successfully then click OK Ta Installing VCOM Manager Installation was completed successfully med S Figure 5 2 Step 3 Check for your selection 14 MICROSENS GmbH amp Co KG MICROSENS Industrial Device Server me System SMTP SNMP Configuration Serial Port Emas semings eel g SMTP Server Pon 25 Management pope perega aa User Name Pamword Email Sender Email Address 1 Email Address 2 Email Address 3 Emal Addross 4 SNA Trap Server SUMP Server 1 SNMP
24. ed IP8 Mask Enabled IP3 Mask Enabled IP10 Mask T Enabled IP11 Mask J Enabled IP12 Mask T Enabled IP13 Mask Enabled IP14 Mask Enabled IP15 Mask P Enabled IP16 Mask T Enabled i Refresh Figure 5 6 Security The following table describes the labels in this screen Label Description Accessible IP Setting masks To prevent unauthorized access by setting host IP addresses and network Password setting You can set the password to prevent unauthorized access from your server Factory default is no password Table 5 2 Security Network Setting Device can connect the Network by wire You must assign a valid IP address for DS before attached in your network environment Your network administrator should provide you the IP address and related settings The IP address must be unique within the network otherwise DS will not have a valid connection to the network You can choose from three possible IP configuration modes Static DHCP BOOTP The Factory Default IP address is 192 168 16 1 17 MICROSENS GmbH amp Co KG MICROSENS General Security Networking DDNS Notification Management Upgrade Firmware Save Load Wire PPPoE V Using Static IP P Using DHCP BOOTP Static IP Settings IPAddess 192168034 00 Netmask 255 255 2550 000 Gatway 19216801 0 DNS1 19216801 DNS2 LL Ethernet Mode Redundant Mode C Switch Mode
25. elp Serial Configuration Port1 Port Alias Port0 Interface RS232 X Baud Rate 38400 Data Bits 8v Stop Bits 1 X Parity None Flow Control None M Force TX Interval Time 0 ms Performance Throughput Latency Apply Figure 5 28 Serial configuration The following table describes the labels in this screen Label Description Port Alias Remark the port to hint the connected device Interface RS422 RS485 2 wires RS485 4 wires 110bps 300bps 1200bps 2400bps 4800bps 9600bps 19200bps RR 38400bps 57600bps 115200bps 230400bps 460800bps Data Bits 5 6 7 8 Stop Bits 1 2 1 5 Parity No Even Odd Mark Space Flow Control No XON XOFF RTS CTS DTR DSR 38 MICROSENS GmbH amp Co KG MICROSENS Force TX interval time is to specify the timeout when no data has been Force TX Interval transmitted When the timeout is reached or TX buffer is full 4K Bytes the Time queued data will be sent 0 means disable Factory default value is 0 Throughput This mode optimized for highest transmission speed Performance Latency This mode optimized for shortest response time Apply Activate settings on this page Table 5 18 Serial configuration Port Profile Firefox e Soy 192 168 EZ Industrial Ethernet Device Server Web 161 https frees 192 168 16 1 gt W Googie n Help Industrial Device Server
26. enable management from Web Click Goto Web Management button to access web Telnet Management Enable To enable management by Telnet Click Goto Telnet Management button to execute Telnet command SNMP Management Enable To enable management by SNMP SNMP Management Settings To configure SNMP related settings 22 Table 5 6 Management MICROSENS GmbH amp Co KG MICROSENS Upgrade Firmware General Security Networking DDNS Notification Management Upgrade Firmware Save Load Firmware Image Browsing Upgrade Figure 5 12 Upgrade Firmware The following table describes the labels in this screen Label Description Browsing Browse the file and upgrade Upgrade Enable the firmware upgrade Table 5 7Upgrade Firmware Save Load General Security Networking DDNS Notification Management Upgrade Firmware Save Load Save Configuration to Flash Apply and Save Load Default D Load Default Reboot Device Reboot Device Import Export Configuration Import o Export ie Refresh 3 Apply Only a Apply and Save Figure 5 13 Save Load 23 MICROSENS GmbH amp Co KG MICROSENS The following table describes the labels in this screen Label Description Save Configuration Save current configuration into flash memory to Flash Load default configuration except the ne
27. evice will get an IP address from PPPoE server Click Return button return the IP Configuration default page MICROSENS GmbH amp Co KG MICROSENS E Industrial Ethernet Device Server Web gt 7 192168161 https 19216816 1 9 Googie n Industrial Device Server Help System PPPoE Setting System Information SNTP Configuration User Name IP Configuration DDNS Configuration Password User Authentication Port Status Link down Serial Setting Disconnect Management Save Reboot Figure 5 24 PPPoE setting DDNS Configuration The Dynamic DNS service allows you to alias a dynamic IP address to a static hostname allowing your computer to be more easily accessed from various locations on the Internet Firefox EC Industrial Ethernet Device Server Web gt E 192168161 https 192168161 8B Google System DDNS Setting System Information SNTP Configuration DDNS i IP Configuration Enable Disable DNS Configurati Sanica Pronii User Authentication est ezip Port Host Name Serial Setting Account Management Password Check WAN IP Schedule EveryHour start at 0 0 Save Reboot Figure 5 26 DDNS setting Industrial Device Server Help MICROSENS GmbH 8 Co KG MICROSENS The following table describes the labels in this screen Label Description Service
28. ial device at the same time 27 MICROSENS GmbH amp Co KG Serial Settings porti MICROSENS Service Mode Notification Service Mode fice Server Mode x TCP Server Mode TCP Server 5 ettings Misc Telnet Negotiation Idle Timeout g 0 65535 Seconds Data Port 4000 eQ Auto Scan Alive Check 140 0 65535 Seconds Control Port 4001 Multilink Max Connections 1 Refresh Destination Host 1 5 IC Refresh Apply Only ar Apply and Save Figure 5 16 TCP Server mode The following table describes the labels in this screen Label Description Encryption with SSL Use SSL to encrypt data Data Port Set the port number for data transmission Telnet Negotiation Full Telnet command symbol compatible Auto Scan Scan the data port automatically Idle Timeout When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check Max Connection The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP connection is not alive the connectio
29. icate disable this function Factory default valueis 0 If Multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 Max Connection The number of Max connection can support simultaneous connections are 5 default values is 1 Table 5 19 Virtual COM mode Not allowed to mapping Virtual COM from web 41 MICROSENS GmbH amp Co KG e ees E Industrial Ethernet Device Server Web System Service Mode Port Serial Setting poni Serial Configuration Data Encryption Enable Disable Port Profile Service Mode Service Mode TCP ServerMode v Management Save Reboot MICROSENS Service Mode TCP Server Mode In TCP Server Mode DS is configured with a unique Port combination on a TCP IP network Inthis case DS waits passively to be contacted by the device Afterthe device establishes a connection with the serial device it can then proceed with data transmission TCP Server mode also supports up to 5 simultaneous connections so that multiple device can receive data from the same serial device at the same time 192 168161 ht 192 168 16 1
30. ice can establish a TCP connection with server by the method you set Startup or any character Afterthe data has been transferred device can disconnect automatically from the server by using the TCP alive check time or Idle timeout settings eg E industrial Ethernet Device Server Web ES 8 7 192 168 16 1 https 192 168 16 1 Google P Industrial Device Server Help System Service Mode Port Serial Setting Fort Serial Configuration Data Encryption Enable Disable Port Profile Service Mode Service Mode TCP ClientMode Management Destination Host 4000 Idle Timeout 0 0 65535 seconds Save Reboot Alive Check 40 0 65535 seconds Connect on Startup Any Character Destination Host Port 1 65535 2 65535 3 65535 4 65535 Apply Figure 5 32 TCP client mode MICROSENS GmbH amp Co KG MICROSENS The following table describes the labels in this screen Label Description Data Encryption Use SSL to encrypt data Destination Host Set the IP address of host and the port number of data port When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will be freed and try to Idle Timeout connect with other hosts 0 indicate disable this function Factory default valueis0 If Multilink is configured only the first host connection is effective for this setting The serial device will send
31. iled E SMTP Mail E SNMP Trap E Syslog evens IP Address Changed El SMTP Mail E SNMP Trap El Syslog Password Changed E SMTP Mail C SNMP Trap Syslog Save Reboot E Access IP Blocked SMTP Mail El SNMP Trap E Syslog E Redundant Power Changed E SMTP Mail E SNMP Trap E Syslog Redundant Ethernet Changed F SMTP Mail E SNMP Trap E Syslog Port Event Notification DCD Changed E SMTP Mail E SNMP Trap Syslog DSR Changed E SMTP Mail SNMP Trap L Syslog RI Changed F SMTP Mail SNMP Trap E Syslog CTS Changed E SMTP Mail E SNMP Trap E syslog Port Connected SMTP Mail SNMP Trap E Syslog E Port Disconnected E SMTP Mail SNMP Trap E Syslog MICROSENS GmbH amp Co KG MICROSENS The following table describes the labels in this screen Label Description Hardware Reset Cold Start This refers to starting the system from power off contrast this with warm start When performing a cold start DS will automatically issue an Auto warning message by sending E mail log information or an SNMP trap after booting Software Reset Warm Start This refers to restart the computer without turning the power off When performing a warm start DS will automatically send an E mail log information or SNMP trap after reboot Login Failed When an unauthorized access from the Console or Web interface a notification will be sent IP Address Changed When IP address of device changed a notification will be sent
32. miters are received or the option Flush Ethernet to Serial data buffer times out 0 means disable Factory default is 0 40 Table 5 18 Port Profile Service Mode Virtual COM Mode In Virtual COM Mode the driver establishes a transparent connection between host and serial device by mapping the Port of the serial server serial port to local COM port on the host computer Virtual COM Mode also supports up to 5 simultaneous connections so that multiple hosts can send or receive data by the same serial device at the same time MICROSENS GmbH 8 Co KG MICROSENS System E2 Industrial Ethernet Device Server Web e 192 168 16 1 htt Service Mode Port Serial Setting Serial Configuration Port Profile Service Mode Management Save Reboot 192 168 161 9 Googe Pla D Industrial Device Server Help Port1 Data Encryption Enable Disable Service Mode Virtual COM Mode Idle Timeout 0 0 65535 seconds Alive Check 40 0 65535 seconds Max Connection 1 v max connection 1 5 Apply Figure 5 30 Virtual COM mode The following table describes the labels in this screen Label Description Data Encryption Use SSL to encrypt data Idle Timeout When serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed and the port will be freed and try to connect with other hosts 0 ind
33. n will be closed and the port will be freed 0 indicate disable this function Factory default is 0 The number of Max connection can support simultaneous connections are 5 default values is 1 28 Table 5 11 TCP Server mode MICROSENS GmbH amp Co KG MICROSENS Service Mode TCP Client Mode In TCP Client Mode device can establish a TCP connection with server by the method you have settled Startup or any character Afterthe data has been transferred device can disconnect automatically from the server by using the TCP alive check time or Idle time settings Serial Settings Service Mode Notification porti Service Mode TCP Client Mode TCP Client Mode TCP Client Settings Misc Encryption with SSL Idle Timeout 0 0 65535 Seconds Destination Host Port Alive Check a0 0 85535 Seconds 4000 r9 Auto Scan Connect on Startup Z Enable Control Port 4001 Multilink Destination Host Port 1 eX Auto Scan 2 eQ Auto Scan 3 eQ Auto Scan 4 eQ Auto Scan IC Refresh 3 Apply Only PS Apply and Save Figure 5 17 TCP Client Mode The following table describes the labels in this screen Label Description Encryption with SSL Use SSL to encrypt data Destination Host Set the IP address of host Port Set the port number of data port When serial port stops data transmission for a defined period of time Idle Time
34. nd ein Passwort Ausgabe der Website cgi bin Benutzername admin Passwort essesseesl Abbrechen Figure 5 21 Certificate Only if password is set 32 MICROSENS GmbH amp Co KG MICROSENS Step 4 The system information will be shown as below ET EZ Industrial Ethernet Device Server Web 3 192168 161 https 192 168 16 1 Industrial Device Server Help System System Information Port Serial Setting System Name MS655400X IP Address 192 168 16 1 Management MAC Address 00 60 A7 03 D3 4B Firmware Version 1 00 Save Reboot Figure 5 21 System information 5 2 1 1 System Time SNTP LEE tes E Industrial Ethernet Device Server Web gt a gt 192168161 https 192168 161 z ELS Google P s PE E ts Industrial Device Server Help System Basic Setting System Information SNTP Configuration Device Server IP Configuration MSOs DDNS Configuration Time User Authenticatio a z oy SNTP Enable Disable Port Serial Setting Time Zone GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna v Local Time 11 03 45 Management Fri Nov 25 2011 03 45 00 GMT Time Server pool ntp org Port 123 Save Reboot Console Telnet Console Enable Disable Figure 5 22 Time SNTP 33 MICROSENS GmbH amp Co KG MICROSENS The following table describes the labels in this screen Label Desc
35. ng TCP connection this event will be trigger In TCP Client Mode when the device has connected to the remote host this event will be trigger In Virtual COM Mode Virtual COM is ready to use A notification will be sent 31 MICROSENS GmbH amp Co KG MICROSENS In TCP Server Client Mode when the device lostthe TCP link this event will be Port disconnected trigger In Virtual COM Mode When Virtual COM is not available this event will be trigger A notification will be sent Table 5 13 Notification 5 2 Configuration by Web Browser 5 2 1 CONNECT TO THE WEB PAGE Step 1 Input the IP address of DS with https 192 168 16 1 in the Address input box of IE Step 2 Click Yes button on the dialog box Security Alert Information you exchange with this site cannotbe viewed orchanged by others However there is a problem with the site s security certificate 6 The security certificate was issued by a company you have not chosen to trust View the certificate to determine whether you want to trust the certifying authority The security certificate date is valid The name on the security certificate is invalid or does not match the name of the site Do you wantto proceed View Certificate Figure 5 20 Certificate Step 3 Input the name and password then click OK Authentifizierung erforderlich x 2 https 192 168 16 1 verlangt einen Benutzernamen u
36. out the connection will be closed and the port will be freed Idle Timeout and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package in each defined 29 MICROSENS GmbH amp Co KG MICROSENS time interval Alive Check to remote host to check the TCP connection Ifthe TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 Connect on Startup The TCP Client will build TCP connection once the connected serial device is started Connect on Any Character The TCP Client will build TCP connection once the connected serial device starts to send data Table 5 12TCP Client mode Service Mode UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can Uni cast or Multi cast data from the serial device server to host computers and the serial device can also receive data from one or multiple host Serial Settings Service Mode Notification porti Service Mode UDP Mode vl UDP Mode UDP Settings Listening Port 4004 r9 Auto Scan Multilink Destination Host Begin Destination Host End Sending Port i 192 168 0 1 ta 1192 168 0 100 10
37. ple host devices 5 simultaneous in Virtual COM TCP Server TCP Client mode UDP Secured Management by HTTPS and SSH Versatile Modes Virtual Com Serial Tunnel TCP Server TCP Client UDP Event Warning by Syslog Email SNMP trap and Beeper Various Windows O S supported Windows NT 2000 XP 2003 VISTA Hardware Features Redundant Power Inputs 12 48 VDC on terminal block and power jack Operating Temperature 10 to 60 C Storage Temperature 40 to 85 C Operating Humidity 5 to 95 non condensing Casing IP 30 2 10 100Base T X Ethernet port Dimensions W x D x H 72mm W x125 mm D x3imm H Hardware Installation 2 1 Install MS655400X on DIN Rail Each MS655400X has a Din Rail kit on rear panel The Din Rail kit helps MS655400X to fix on the Din Rail It is easy to install the MS655400X on the Din Rail 2 1 1 Mount MS655400X on DIN Rail Step 1 Slant the MS655400X and mount the metal spring to Din Rail MICROSENS GmbH amp Co KG MICROSENS Metal Spring Figure 2 1 Step 2 Push the MS655400X toward the Din Rail until you heard a click sound Figure 2 2 MICROSENS GmbH 8 Co KG MICROSENS 2 2 Wall Mounting Installation Each MS655400X has another installation method for you A wall mount panel can be found in the package The following steps show how to mount the MS655400X on the wall 2 2 1 Mount MS655400X on wall Step 1 Remove Din Rail kit Figure 2 3 Step 2 Use 6 scre
38. rating Temperature 10 to 60 C 14 to 140 F Operating Humidity Storage Temperature 5 to 95 Non condensing 40 to 85 C 40 to 185 F 52 MICROSENS GmbH amp Co KG MICROSENS Mechanical Dimensions W x D x H 72mm W x125mm D x31mm H Casing IP 30 protection Regulatory Approvals Shock IEC 60068 2 27 Free Fall IEC 60068 2 32 Vibration IEC 60068 2 6 EMI CISPR EN55022 class A EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EMS EN61000 4 5 Surge EN61000 4 6 CS 53 MICROSENS GmbH 8 Co KG
39. rial port is transmitting data Serial Red Blinking Serial port is receiving data Table 3 1 Front panel LEDs MICROSENS GmbH 8 Co KG MICROSENS 3 3 Top Panel The Top panel components of MS655400X are shown as below 1 Terminal block include PWR1 12 48V DC 2 Power Jack include PWR2 12 48V DC 3 RJ45 Ethernet Connector 2 10 100Base T X Ethernet interface 1 2 3 DC12 48V PWRI_ PV R2 Auto MDI MDIX MA ANL KO GO Figure 3 2 3 4 Bottom Panel The bottom panel components of MS655400X are shown as below Figure 3 3 1 Reset button 5 seconds for factory default 2 Male DB9 connector Serial interface of RS 232 422 485 2 wire 4 wire DB9 connector 9 MICROSENS GmbH 8 Co KG MICROSENS Pin RS 232 RS 422 pate toits 1 DCD RXD RXD 2 RXD RXD RXD 3 TXD TXD TXD DATA 4 DTR TXD TXD DATA 5 GND GND GND GND 6 DSR 7 RTS 8 CTS 9 RI RS 232 mod act as DTE Table 3 2 Pin assignment 3 DIP Switch Termination for RS 422 485 DIP 1 DIP 2 Termination Configuration ON ON Termination for long distance 4 wire RS485 422 ON OFF Reserved OFF ON Termination for long distance 2 wire RS485 OFF OFF No termination for RS485 422 short distance Table 3 2 DIP Switch MICROSENS GmbH amp Co KG MICROSENS 3 5 Rear Panel The rear panel components
40. ription Name You can set the name of DS SNTP Enable the SNTP server Time zone After you set the SNTP enable select the time zone you located Time server Input SNTP server domain name or IP address and Port Console Telnet Console SSH is included for security reasons In some cases you may need to disable this function to prevent unauthorized access from internet The factory default is enable tees Table 5 14 Time SNTP IP Configuration You must assign a valid IP address for DS before attached in your network environment Your network administrator should provide you with the IP address and related settings The IP address must be unique and within the network otherwise DS will not have a valid connection to the network You can choose from three possible IP configuration modes Static DHCP BOOTP The Factory Default IP address is 192 168 16 1 34 Industrial Ethernet Device Server Web System Information SNTP Configuration IP Configuration Static M IP Configuration DDNS Configuration IP Address 192 168 16 1 User Authentication Port Netmask 255 255 255 0 Serial Setting Gateway 192 168 16 254 Management DNS Server 1 192 168 16 254 DNS Server 2 Save Reboot C 192 168161 https 192 168 161 B Googie Pla Industrial Device Server Help System IP Configuration Auto IP Report Auto Report to IP Auto Report to TCP Port 9
41. s the labels in this screen Label Description Port Alias Remark the port to hint the connected device Interface RS422 RS485 2 wires RS485 4 wires 110bps 300bps 1200bps 2400bps 4800bps 9600bps 19200bps SS es 38400bps 57600bps 115200bps 230400bps 460800bps Data Bits 5 6 7 8 Stop Bits 1 2 1 5 Parity No Even Odd Mark Space Flow Control No XON XOFF RTS CTS DTR DSR eas Dene Throughput This mode optimized for highest transmission speed Latency This mode optimized for shortest response time Serial to Ethernet Delimiter You can define max 4 delimiters OO FF Hex for each way The data will be hold until the delimiters are received or the option Flush Serial to Ethernet data buffer times out O means disable Factory default is 0 Flush Data Buffer After The received data will be queuing in the buffer until all the delimiters are matched When the buffer is full 4K Bytes or after flush S2E data buffer timeout the data will also be sent You can set the time from 0 to 65535 seconds Ethernet to Serial Delimiter You can define max 4 delimiters OO FF Hex for each way The data will be hold until the delimiters are received or the option Flush Ethernet to Serial data buffer times out 0 means disable Factory default is 0 Flush Data Buffer After The received data will be queuing in the buffer until all the delimiters are matched When
42. twork settings If you want to load Load Default all factory default you need to press Reset button on the device Hardware restore Reboot Device Reboot the device server warm start Import Configuration Restore the previous exported configuration Export Configuration Exported current configuration to a file to backup the configuration Table 5 8 Save Load 5 1 2 3 Configure serial port Serial Settings Serial Settings Service Mode Notification porti Port Alias Port0 Baudrate 32400 StopBits f4 Performance Throughput E Parity No x Flow Control No Flow Data Bits g Interface RS232 Delimiter Settings Serial to Ethemet Ethernet to Serial Delimiter 1 Delimiter 2 Delimiter 3 Delimiter 4 HEX HE HE HEX Enabled Enabled Enabled Enabled Flush Serial to Ethernet Data Buffer After 0 0 65535 ms The received data will be gueueing in the buffer until all the delimiters are matched When the buffer is full 4K Bytes or after flush S2E data buffer timeout the data will also be sent Force TX interval time 0 0 65535 Ims data1 Jihter llime data 2 Jihtemaltime data3 The received data will be queueing in TX buffer until TX interval time is timeout or TX buffer is full 4K Bytes the data will also be sent 0 is disable i Refresh Figure 5 14Serial Settings 24 MICROSENS GmbH amp Co KG MICROSENS The following table describe
43. ws that can be found in the package to combine the wall mount panel Just like the picture shows below Figure 2 4 6 MICROSENS GmbH 8 Co KG MICROSENS The screws specification shows in the following two pictures In order to prevent MS655400X from any damage the size of screws should not be larger than the size that used in MS655400X Pozidrive Figure 2 5 Hardwa re Overview 3 1 Front Panel Figure 3 1 1 Product description of MS655400X 2 LED for PWR1 and system status When the PWR1 links the green led will be light on 3 LED for PWR2 and system status When the PWR2 links the green led will be 7 MICROSENS GmbH amp Co KG light on LED of 10 100Base T X Ethernet port 1 LED of 10 100Base T X Ethernet port 2 MICROSENS LED of serial port Green for transmitting red for receiving 3 2 Front Panel LEDS The following table describes the labels that stick on the MS655400X LED Color Status Description On DC power 1 activated PWR1 Green Red 7 A Indicates an IP conflict or DHCP or BOOTP Red blinking server did not respond properly On DC power 2 activated PWR2 Green Red ae Indicates an IP conflict or DHCP or BOOTP Red blinking i server did not respond properly Green On Blinking 100Mbps LNK ACT ETH1 Green Amber Amber On Blinking 10Mbps LNK ACT Green On Blinking 100Mbps LNK ACT ETH2 Green Amber Amber On Blinking 10Mbps LNK ACT Green Blinking Se