Home

993801 WRS-6 Manual

image

Contents

1. pump to cool before servicing Basin Screen Remove 4 1 4 20 screen cover plate screws plastic cover plate seal ring and screen Clean inlet screen using a mild detergent and water Examine O ring and if deformed replace with new O ring See replacement parts table Basin Sediment may build up in basin causing pump to oper ate improperly Remove 10 1 4 20 screws from cover Remove cord grommet and loosen cords to allow slack and then remove cover Remove pump and clean basin using a mild detergent and water Reassemble in reverse order Torque screws 18 20 in lbs If pump alignment plate is removed it must be reinstalled per pump alignment diagram Figure 1 Typical Installation CORD GROMMET INCLUDED 3 VENT PIPE FILTER ACCESS COVER WITH O RING FILTER Ps WN E AX A UNION 1 1 2 INTAKE COVER O RING LITTLE GIANT PUMP MODEL 6 CIA NOT INCLUDED E 8 FT POWER CORD L w SS SS AS Ss ds e e a a i i a a a Pump Sediment or lint can clog pump and cause improper operation If necessary remove pump and pull off the pressed in screen Clean using a mild detergent and water and reinstall Plastic pump base may also be removed to clean around impeller and inside base Remove the six base screws and clean base using a mild detergent and water Do not remove impeller When reinstalling base be sure seal ring is seated properly in groove and torque screws to 10 1
2. 5 in lbs See pump manual for other information For any other pump repair return the pump to a Little Giant authorized service center 1 1 2 CHECK VALVE 1 1 2 UNION 1 1 2 DISCHARGE PIPE BASIN COVER BASIN ee 1 1 2 DISCHARGE PIPE i A 15 56 3 8 DIA BLEED HOLE bae ee ad a re a a ae IN DISCHARGE PIPE LITTLE GIANT PUMP MODEL 5 CIA FE E E a En 10 63 DIA 13 98 DIA B FT POWER CORD i CORD GROMMET INCLUDED BASIN COVER E7 uy ES ee o EA AAA 1 1 2 CHECK VALVE 22 VENT PIPE ee FILTER ACCESS COVER A WITH O RING 1 1 2 UNION FILTER it 1 1 2 DISCHARGE PIPE 1 1 2 INTAKE COVER O RING ITEMS NOT INCLUDED WITH WRS 6 BASIN KIT H al ih ft im SS Mi Mem my 00 ara BASIN 1 1 2 DISCHARGE PIPE 3 8 DIA BLEED HOLE IN DISCHARGE PIPE LITTLE GIANT PUMP MODEL 6 CIA 10 563 DIA 13 88 DIA Figure 2 REPLACEMENT PARTS AMEN PARTS MENE CIA UC e iss reesen o ee foma senza 1 Figure 3 1 MOUNTING HOLE LINES UP WITH LOCATING RIB ON THE INSIDE OF THE BASIN PLATE ALIGNMENT DIAGRAM POSITION THE PUMP LOCATING PLATE INSIDE THE BASIN AS SHOWN THIS WILL ALLOW PROPER ALIGNMENT OF MOUNTING HOLES WHEN INSTALLING THE BASIN COVER A OTHER POSITION WILL NOT ALLOW ASSEMBLY OF COVER SPECIFICATIONS MODEL NO VOLTS HERTZ WATTS 5 SHUTOFF FT UN Wass 15 60 18 FOR TROUBLESHOOTING INFORMAT
3. ION SEE PUMP OWNERS MANUAL INCLUDED WITH WRS 6 BASIN KIT ONE YEAR LIMITED WARRANTY For one year from date of purchase Little Giant will repair this unit if defective in material or workmanship Warranty service is available by returning the unit pre paid to the factory For further details please consult the warranty statement on carton This warranty gives you specific legal rights and you may also have other rights which vary from state to state For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 Pour des parties ou la r paration entrez s il vous plait en contact ooooooo ooo 1 888 572 9933 Pour laide technique entrez s il vous plait en contact 1 888 956 0000 Para partes o la reparacion por favor p ngase en contacto 00c eee eeee 1 888 572 9933 Para la ayuda t cnica por favor p ngase en contacto 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com Form 993801 09 24 2009 2007 Franklin Electric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc
4. Littie GIANT Franklin Electric Co Inc P O Box 12010 Oklahoma City OK 73157 2010 405 947 2511 Fax 405 947 8720 www LittleGiantPump com CustomerService WTS fele com WRS 6 Wastewater Removal System with 6 CIA Pump CEN INTRODUCTION This instruction sheet provides you with the information required to safely own and operate your product Retain these instructions for future reference The product you have purchased is of the highest quality work manship and material and has been engineered to give you long and reliable service This product has been carefully tested inspected and packaged to ensure safe delivery and operation Please examine your item s carefully to ensure that no damage occurred during shipment If damage has occurred please con tact the place of purchase They will assist you in replacement or repair if required READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OPERATE OR SERVICE YOUR PRODUCT KNOW THE PRODUCT S APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE DESCRIPTION This unit is designed to pump wastewater from laundry trays washing machines sinks or dehumidifiers It is not designed to pump raw sewage fluids other than water or fluids with solids Inlet screen will remove many solids over 1 8 diameter
5. but large amounts of solids can clog screen and result in pump failure Maximum fluid temperature is 125 F Unit is designed to fit under most sinks so in many cases it is not necessary to recess the unit into the floor ITEMS TO PURCHASE NOTE Some state or local codes require all electrical and or plumbing connections to be made by a licensed contractor It is the customer s responsibility to determine codes involved and to comply with these codes If user can install unit items to purchase are 1 Inlet piping with trap and union Basin cover has 1 1 2 FNPT fitting 2 Discharge piping with swing check valve and union Basin cover has 1 1 2 FNPT fitting 3 Vent piping Basin cover has 2 FNPT fitting SAFETY GUIDELINES y 1 CAUTION To reduce the risk of electric shock pull plug before servicing this pump 2 Read all instructions and safety guidelines thoroughly Failure to follow the guidelines and the instructions could result in serious bodily injury and or property damage 3 Check local electrical and building codes before installation The installation must be in accordance with these regulations 4 During normal operation the pump is immersed in water Use caution to prevent bodily injury when working near the pump a Remove plug from the receptacle prior to touching servic ing or repairing the pump b To minimize possible fatal electrical shock hazard use extreme care when changing fuse
6. o the basin Use pipe joint Compound and hand tighten only on plastic fittings Do not reduce below 1 1 2 piping 3 Plumb discharge Using 1 1 2 threaded pipe plumb discharge to basin cover fitting Use a swing check valve no more than 3 from top of basin cover and a union Be sure check valve is installed in proper flow direction If check valve is installed backwards no water will flow out of unit Be sure discharge piping is sealed with pipe joint compound and that lift height of pump is not exceeded Hand tighten only on plastic fittings 4 Plumb vent Plumb vent using 2 threaded pipe to fitting in basin cover Use pipe joint compound on threads and hand tighten only on plastic fittings The basin must be vented in accordance with state and local codes The vent is essential for proper switch operation and must not be omitted or restricted CAUTION Do not use a mechanical vent with this product A mechanical vent will Cause improper operation of the auto matic switch 5 Test unit Connect power cord to electrical supply as stated in ELECTRICAL CONNECTIONS section Secure power cord to piping with ties or tape Fill unit with water through inlet Pump should turn on with 7 10 of water in tank and turn off when 1 3 of water is left in tank MAINTENANCE WARNING Before performing any maintenance shut off water inlet and disconnect power cord from supply outlet Pump may become hot during operation Allow
7. s Do not stand in water while changing fuses or insert your finger into fuse socket ELECTRICAL CONNECTIONS All wiring must meet local codes and a licensed electrical contractor is recommended The pump is supplied with a 3 prong vented plug Plugs must be plugged into a grounded receptacle and vent tube must remain unobstructed for proper pump operation Pump should be on a separate circuit with fuse or circuit breaker and ground fault circuit interrupter GFCI Be sure electrical supply matches pump nameplate data Do not use extension cord If installed in basement plug connection should be 4 or more above floor especially if basement floods Be sure electrical connections cannot be reached by rising water Under no circumstances should outlet box or receptacle be located where it may become flooded or submerged by water INSTALLATION All plumbing must meet local codes A licensed plumbing con tractor is recommended All fixtures connected to the WRS 6 Basin Kit must be vented according to state and local codes 1 Determine proper location for unit Locate unit so that inlet is gravity fed Unit will not draw water up from a lower level Position and level basin Keep basin away from any item that could puncture basin Position selected should be convenient to inlet discharge and vent piping and electrical supply 2 Plumb inlet Using 1 1 2 threaded pipe plumb inlet to basin cover fitting Use a P trap and a union next t