Home
User Manual
Contents
1. BLACK WIRE RED WIRE Door Lock C If you have normal DC 12V Power supply only and want to use the controller as RELAY switch PLEASE set JUMPER J1 to 2 3 Connect the locking device to the COM amp NC NO 4 Jumper Instructions Jumper JP 1 Position A J1 set to 1 2 LOCK Connect the NO type lock to NO 12V amp LOCK OR Connect the NC type lock to NC 12V amp LOCK to keep door controller work steadily we do not suggest to connect electric lock directly with controller please use specific power supply as 4A above B J1 set to 3 4 PUSH Factory default setting Connect the PUSH to specific power supply PUSH C J1 set to 2 3 RELAY NO NC amp COM will act as relay switch no current output 5 Programming Original management pass word is 12345 and user password is 8888 1 Enter programming mode push gt input management pass word gt push e g push 123456 2 Function setup under programming mode circumstance 1 Modify management password push 0 gt input new management password gt push gt again input new management password gt push note password is 4 8 digital number 2 Add user card push 1 gt read card gt push 4 digit user defined ID gt push gt push e g push 1 read card push 0001 note a 4 digit user defined ID must be 0001 to 9999 cannot be duplicated b If need add mor
2. Open by card and password door can be opened if correct password is input 10 seconds after card is read Open by password door can be opened by inputting user password Attention the door controller supports 3 modes opening by card by password and by card and password 7 Hardware Reset Procedure Factory Reset procedure for door controller 1 switch off power and keep pushing RESET holding it 2 switch on the power and press RESET for 3 seconds then unhold it and reset procedure is completed Status the door controller goes into working status with 1 sound of buzzer Note 1 This procedure only change system password to default programming password 12345 and user password 8888 others remain the same 2 normally please don t use initialization back to default unless user forgets password Appendix 1 LED amp Buzzer Issue type Red light Green light Buzzer Normal working circumstance aon read valid card correct password light two short unlock beep open door ee button then light one short beep wrong password light ee a invalid card light m entry valid button light one short beep alert to prevent from unpacking glitter long beep programming status light light a a entry correct programming code light glitter quickly one short beep entry wrong programming code light three short beep Appendix 2 Content Packing list Access controller User manual 1 set 1 pi
3. e than 1 card push 1 gt read 1 card gt push 4 digit user defined ID read 2 card gt read 3 card gt push gt push e g push 1 read 1 card push 0005 read 2 card read 3 card push the 1 card will be 0005 2 card will be 0006 3 card will be 0007 c 3 4 ways to delete user card A Delete all user card push2 gt push 0000 gt push gt push B Delete the card read push2 gt read card gt push gt push C Delete more than 1 card read push2 gt read 1 card gt read 2 card gt read 3 card gt push gt push D Delete lost card push2 gt push 4 digit user defined ID gt push gt push 4 Setup for open mode A Open with reading valid card push 300 gt push gt push B Open with reading valid card and password push 301 gt push gt push C Open with reading valid card or correct password push302 gt push gt push note original setup is 302 for reading valid card or input password to open door 5 Setup for open door time Push 4 gt X X gt push gt push note XX is during 00 99 measure unit is second and default value is 3 seconds and 0 is added for less than 2 digitals 6 How to modify use password push 5 gt input 1 new password with 4 digit number gt push gt push gt again input 1 new password with 4 digit number gt push gt push to save 7 Anti breaking Mode To Disable anti breaking alarm mode factory d
4. ece
5. efault is disabled Push 600 gt push gt push To Enable anti breaking alarm mode Push 601 gt push gt push Please ensure the anti breaking switch is properly setup 8 Monitor Door open status To Disable monitor door open status factory default is disabled Push 700 gt push gt push To Enable monitor door open status Push 701 gt push gt push please connect the door sensor to DOOR IN amp MUL e when this monitor is enabled after the door open under authorization if the door is not closed after 1 minute the buzzer will make sound e when this monitor is enabled if the door is opened by force without card or password it will make alarm output at ALARM port Please use valid card to stop the alarm 9 Wrong Password Alarming To Disable wrong password alarming factory default is disabled Push 800 gt push gt push To Enable wrong password alarming Push 801 gt push gt push e when this Wrong Password Alarming is enabled if invalid card or wrong password is tried for 10 times it will make alarm output at ALARM port e when this monitor is enabled if the door is opened normally by card or password press 8 within 2 seconds after the lock open it will make alarm output at ALARM port this can act as emergency help Please use valid card to stop the alarm 6 User Operation Open by card under normal working environment door can be opened with 1 valid card
6. eved easily C Easy Programming adding new card delete card with master password 2 Product Specification working voltage DC 12V unlock current lt 1 5A static current lt 1A available card quantity 800 pieces Maximum card read distance 5cm RF card type Mifare 1 or compatible cards Key rings working temperature 40 C 70 C working moisture 10 90 size 117x117x21mm 3 Installation Unpack cross screw that fixes faceplate and motherboard then take off motherboard and get it assembled on side wall which is at the exit with attention on vertical orientation Alert Please ensure to switch off power before connecting lines and switch on power after all lines being connected well Please be sure that power voltage is 12v and that anode amp cathode are in place 3 Connection Diagram A If you have a specific power supply with timer control please connect it as below diagram PLEASE set JUMPER J1 to 3 4 PUSHI Power Supply NOCOMNC 12V GND PUSH BLACK WIRE Door Lock RED WIRE CO CLL CLI CL 12V GND PUSH COM NC LOCK AENT pri DOOR MUL BELL BELL I NO j 2 coo Door sensor Door Bell Open Switch Alarm B If you have normal DC 12V Power supply only please connect it this way PLEASE set JUMPER J1 to 1 2 LOCK O O LL CLI Cl 12V GND PUSHCOM NCLOCK ALARM hs DOOR MUL BELL BELL INO j i 2 iv Door sensor Door Bell Open Switch Alarm
7. ot cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment CE Mark Warning CE This is a class B product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Index 1 Product Description 2 Product Specification 3 Installation 4 Connection Diagram 5 Jumpers Instructions 6 Programming 7 User Operations 8 Hardware Reset Procedure Appendix 1 LED amp Buzzer 2 Contents 1 Product Description This is single door controller is a series of independent ones that are developed for the control of exits of office building intellectual building residential area public channel of building through which user can open door with respondent card can open with pass code or can with both respondent card and pass code then a simple door controller system solution program is made Comparing with similar products in the current market our product CK138 Mifare has the following advantages A High Security supporting wrong password alarming anti breaking alarming alarm signal output B Memory Backup chip circuit design programming is not required when replacing new unit user cards information can be retri
8. r CN2HK LIMITED Single Door Access Controller System CK 138 Mifare User Manual Please read this manual before operating this product ENG CEFE After you finish reading this manual store it in a safe place for future reference FCC STATEMENT C This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n