Acroprint ATR120 Electronic Time Clock (beige) User Manual

image

Contents

1. Setting the two color printing and internal signal tone Time cards can be audited much easier by highlighting in red punches outside the normal work schedule Using the internal audible signal will remind your employees of start and stop times in their work schedule You can even have a warning signal two minutes before start time to alert your employees This program allows for a total combination of 32 scheduled events Events can be selected to allow a ribbon color change or a signal tone or a combination of both Each event can be programmed for the time of day in hours and minutes and the day of week The events available are Clock to print in RED Clock to print in RED with SIGNAL Clock to print in BLACK Clock to print in BLACK with SIGNAL Clock to SIGNAL without a color change Note The default ribbon color is black The clock has to be programmed at a specific time to print in red Once a color change occurs the clock will print in that color until an opposite color change is activated The following is a sample schedule of events for a 8 00 AM to 5 00 PM work schedule with a one hour lunch period from 12 00 Noon to 1 00 PM 13 00 This schedule has the clock printing in RED at 8 01 AM to 12 Noon Any late in or early out punches will print in RED The clock will print in BLACK during the lunch period Then printing in RED at 1 01 PM 13 01 until 5 00 PM 17 00 At 5 00 PM the clock will print in BLACK allowing for exit punches At
2. TIME CLOCK WORLD 888 534 5994 ATR120 USER MANUAL II HI Iv VI VII VII Table of Contents ai rapa l QVEIVIEW Les Jason dE Ta SUDO 1 1 A CCESSOLIES 1 2 P ck ge 2 Location of Components parmanente epi matte 3 Getting Started sia E 3 Installing clock dial battery ececccesecssecseeeeeeeeeeeeeeeeeseeeeeeeeeeeresteneenteensees 3 Setting the ad da h as 4 Programming Hints jus essere iss ga repente tada a a 4 Selecting day Of Week E TE 5 Seto te time maia cana Sad sata Lada cana sted 7 Setting the year month and date 0 0 cccecseescesceeeceesceeeceeeeeeeeecsaeeseeeneeeseeenes 7 Setting Daylight Saving Time cccccceessesseesseeeeeeeceeeceeeeseceseceaecnsecaeeneeenes 8 Setting the day change 9 Setting the printing 9 Setting the two color printing and internal signal 10 Setting signal duration sis esa ceececevectedececeeetevedsouccediedecdecesthceveedevesecesceee 13 Setting auto col
3. The ATR120 has built in diagnostics to guide you in maintaining your time clock These Error Codes when occurring will be seen on the display Code Meaning of Error Check E 01 Clock motor or sensor failure Unplug and reconnect power cord or turn the program switch on off twice letting the clock readjust E 03 Card positioning Contact dealer or factory E 05 Card does not feed correctly Re insert card and print E 30 Printer head fails to return to position home Contact dealer or factory Can t change color Check that the ribbon is installed correctly Contact dealer or factory The card can t be returned Make sure there are no obstructions in card receiver Contact dealer or factory E 37 Sensor cannot locate card Contact dealer or factory E 38 Printer head jammed Contact dealer or factory E 40 Wrong password entered Enter the correct password 21 For any other Error Codes contact your dealer or Acroprint Time Recorder To return to the original Factory settings press the reset switch located on the back of the clock next to the PRO switch When resetting the clock make sure the PRO NOR is in the NOR position After resetting enter the PRO mode to reprogram the clock 22
4. indicating the day change time Five o clock AM is the default time for the day change to take place This is the time that the ATR120 will change to printing the time on the next row for the next day You may want to change this to another time such as midnight 00 00 e Press button four to adjust the hour 00 23h the day change should take place OUT3 flashes in the lower right hand corner of the display indicating this setting has not been saved e Press button six one time to save the day change time setting Setting the printing format The ATR120 will print in standard minutes 60 or in decimal hundredths 100 of an hour For example 12 45 will be printed 12 45 in the standard minute format or as 12 75 if hundredths is chosen PM hours are indicated by minutes being over scored Example Two fifteen in the afternoon would print as 02 15 in 12 hour format or 14 15 in 24 hour format e Press button one once If you are entering the programming mode for the first time press button one five times to set the printing format The display should now read Cd 60 indicating the ATR120 is set to print standard minutes e Press button five to change the printing format The display will toggle back and forth between Cd 60 and Cd 100 with OUT3 flashing in the lower right hand corner Cd 100 represents minutes being printed in a decimal hundredths format e Press button six once to save the print format OUT3 will no longer be displayed
5. The display should now read S2 0 0 The ending date for Daylight Saving Time is set exactly the same as the beginning date Press button four to set the month 1 12 with 1 January 2 February etc The display reads S2 0 0 with OUT3 flashing in the lower right hand corner of the display Press button four until the month Daylight Saving Time should end is set Press button five to set the day of the month OUT3 flashes in the lower right hand corner of the display Press button five until the day Daylight Saving Time should end is set Press button six to save the month and day Daylight Saving Time should end OUT3 will no longer be displayed indicating this setting has been saved The display will return to the starting date Note The starting and ending dates for Daylight Saving Time must be set each year Both the starting and ending dates must be set for Daylight Saving Time to be operational At midnight on the starting date the clock will automatically advance one hour At midnight on the ending date the clock will go back one hour For 8 example on the first date of Daylight Saving Time the clock will advance from midnight to 01 00 At midnight on the last day the clock will change from 00 00 to 23 00 Sefting the day change time e Press button one once If you are entering the programming mode for the first time you will need to press button one four times to set the Day Change Time The display should read 5 00
6. period 3 9 second Tuesday of pay period 3 10 second Wednesday of pay period 3 11 second Thursday of pay period 3 12 second Friday of pay period 3 13 second Saturday of pay period 3 14 second Sunday of pay period 6 e Press button six to save your settings OUT3 is no longer displayed Setting the time Make sure the ATR120 is in programming mode Press button one once to start setting the current time This mode starts the clock timing device The display indicates the time at which the clock is currently set Depending on how long you have been in the program mode the display may advance from the default setting of 00 5 00 Press button four to set the hours 24 hour format 0 23 with 0 midnight The display reads 00 6 00 with OUT3 flashing in the lower right hand corner Advance to the correct hour Note Hold down button four to rapidly advance the hour Press button five to set the minutes The display reads 00 6 50 with OUT 3 flashing in the lower right hand corner Advance to the correct minutes Press button six to save the time setting OUT3 disappears The seconds reset to 0 Setting the year month and date Press button one once twice if just entering the programming mode to set the year month and date The display indicates the last programmed year month and date with the default being 99 1 1 Press button three to set the year The display reads 00 1 1 with OUT 3 flashing in the lower right h
7. pulled in and printed Do not attempt to pull the card out during the printing operation or to insert any objects other than time cards Doing so can result in damage to printer VIII Maintenance Several simple suggestions may extend the life of your ATR120 e Close the anti dust cover after operation e When the case is dirty wipe it with a damp soft cloth If necessary a mild detergent may be used Do not use any type of thinner or other chemical for cleaning because the chemical could damage or discolor the case Replacing the ribbon When the printing on the time card becomes light or hard to read it will be necessary to replace the ribbon Use the ATR122 replacement ribbon cassette Attempting to re ink the cassette will cause permanent damage to the printer a 7 x 7 pe O O Press these areas To open the front cover turn the clock on its back and remove the two outer screws Stand the clock upright with the back facing you With both thumbs press down on IN1 and OUT3 buttons while using your fingers to push cover away two 060 o 05 19 Next remove and discard the pin and clip Remove the ribbon cassette by first sliding it left and then upwards as shown by the illustration A amp B Place the new ribbon into the ATR 120 It is not necessary to replace the pin and clip Turn the ribbon feed knob counterclo
8. the lower right hand corner The 5 represents five seconds Press the fifth button to choose the signal duration from 0 to 60 seconds e Once you have chosen the signal duration press button six one time to save it OUT3 will no longer be displayed Setting auto column shift print position This feature may not be appropriate for all installations The auto column shift is a special feature for installations where most or all employees arrive and depart at the same time Employees who arrive or depart at different times may be required to manually reset the card column position Failure to do so will result in printing in the wrong location on the time card For ease of operation of the ATR120 caution should be used in selecting this feature If the auto column shift position is manually changed the clock will return to the scheduled auto position after 7 8 seconds The auto column shift feature allows for a total of 18 horizontal moves It is recommended that a program chart be used to create a schedule to assist in programming this feature A sample program chart is shown below for an 8 00 AM to 5 00 PM shift with lunch between 12 00 Noon and 1 00 PM Employees may punch in after 7 30 AM Employees start lunch at 12 00 PM and must take at least a 15 minute lunch to punch in IN2 column AT 5 00 PM the clock will advance to OUT2 Overtime punching is allowed after 5 30 PM And a minimum of 30 minutes is permitted before moving to the colum
9. will print in RED allowing for quick and easy auditing of exception punches The built in signal can be programmed to audibly denote start and stop work times The large analog clock face not electronically synchronized with the digital display is easy to read from across the room With a built in battery back up auto daylight saving adjustments and a perpetual calendar the ATR120 Time Clock will always print the correct time Specifications Power Source 115VAC 60Hz Power Consumption 0 3V Clock Accuracy 3s per week Ambient Temperature 23 F 104 F 5 C 40 C Ambient Humidity 20 80 Analog Clock 1 AA Battery 1 5V Size 8 1 W x 8 85 H x 4 93 D 205mm W x 225mm H x 125mm D Accessories To assure proper operation please use the accessories designed to work with the ATR120 ATR121 Weekly Bi Weekly Time Card Part Number ATR122 Two Color Replacement Ribbon Cassette Part Number Features Compact design for desktop or wall mounting Weekly or bi weekly pay periods Digital display shows time and date and is synchronized with dot matrix printer 9 pin dot matrix printer that allows for 12 or 24 hour amp 60 100 print format Easily distinguish printing time between AM and PM PM minutes or hundredths are over scored 8 00 8 00 PM 2 color red black cassette ribbon can be programmed so punches outside of schedule will print in red Built in signal tone to denote start and stop times Daylight Saving Time and
10. 5 30 17 30 the clock will return to RED to note OT punches or late outs The clock will return to BLACK at 07 30 in the morning to allow for IN punches for that day The internal signal will sound at 8 00 AM 12 00 1 00 PM and 5 00 PM audibly notifying start and stop times On the chart on the next page the IN OUT under each event denotes the event selection shown on bottom of the display during the programming of these events 10 Print in i Print Black Black i amp Signal OUTI IN2 Event Time Description of Event 1 8 00 SIGNAL Only to denote start of work schedule 2 8 01 Color changes to RED to denote late or early lunch punches 3 12 00 SIGNAL noting start of lunch period and color change to BLACK SIGNAL 4 13 00 SIGNAL Only to denote end of lunch period 5 13 01 Color change to RED to show late in punches or early end of day out punches 6 17 00 SIGNAL to denote end of work schedule and color change to BLACK 7 17 30 Color change to RED to indicate possible overtime 8 0730 Color change to BLACK to allow morning in punches When the display shows 01 5 00 Press button two to select the event IN1 print in red or OUT1 print in black etc Press button three to confirm the event OUT3 will continue to flash Press button four to select the hour of the event Press button five to select the minute the event will occur To have the event occur each day Recommended press button six to save the event and advance to t
11. and corner of the display Press button three until the correct year is set Press button four to set the month 1 12 with 1 January 2 February etc OUT3 flashes in the lower right hand corner of the display Press button four until the current month is set Press button five to set the date OUT3 flashes in the lower right hand corner of the display Press button five until the current date is set Press button six to save the year month and date settings The display should show the correct month and date 7 Setting Daylight Saving Time Press button one once If you are entering the programming mode for the first time you will need to press button one three times to set Daylight Saving Time The display reads S1 0 0 with S1 indicating the start of Daylight Saving Time Press button four to set the month 1 12 with 1 January 2 February etc The display reads 51 0 0 with OUT3 flashing in the lower right hand corner of the display Press button four until the month Daylight Saving Time should start is set Press button five to set the day of the month OUT3 flashes in the lower right hand corner of the display Press button five until the day Daylight Saving Time should start is set Press button six to save the month and day Daylight Saving Time should start OUT3 will no longer be displayed indicating this setting has been saved The program will automatically switch to setting the ending date for Daylight Saving Time
12. ckwise until the ribbon is taut Close the front cover ribbon feed knob IX Troubleshooting cassette ribbon Possible Cause Clock does not accept time cards AC power is OFF Power cord is disconnected AC fuse blown DC fuse blown Still in program mode Worn ribbon Ribbon cassette not seated correctly Printing in wrong Incorrect pay period starting position day Time card inserted incorrectly Printing head fuse blown Printing light Not printing Ribbon cassette not seated correctly AC power is off Power cord is disconnected AC fuse blown Clock stopped Restore power Restore cord to outlet Replace AC240V 1A fuse Replace DC 12V 2A fuse Return switch to NOR position Replace ribbon cassette Reinstall ribbon cassette Set correct day Insert card correctly Replace DC 12V 1 5 Amp fuse Reinstall ribbon cassette Restore power Restore cord to outlet Replace AC240V 1A fuse Analog clock slow or Battery weak Replace AA battery stopped Out of synchronization Reset to digital display 20 Location of fuses The fuse panel is located on the back of the ATR120 in the lower left corner To access fuses disconnect the power from the clock and remove the screw securing door Replace blown fuse with only the same rated fuse Do not substitute EE ETO Fuse Panel Error Codes 1 Printer Head Fuse 1 5A DC 12V 2 AC Fuse 1A AC 240V 3 DC Fuse 2A DC 12V
13. el into place for easy access when setting the clock If you remove the locking tab we suggest you keep the tab To remove the locking tab unfasten the screw located in the front cover and remove the screw and clip The screw and clip may be stored by securing it into the post screw hole below where it was removed It is not necessary to remove the locking tab to install the battery or to adjust the clock dial time setting Once the front cover is open you will be able to install the battery and to set the time on the dial Opening the front cover also allows you to access the ribbon cassette V Setting the ATR120 Programming Hints The ATR120 incorporates features to make the task of time and attendance faster and easier The simplest way to program the ATR120 is to set all of the functions at one time while in the program mode Although you may set functions independently it is recommended that you follow the program sequence When programming the time and the time of day for events to occur the display will show time in a 24 hour format i e 3 00 PM will be 15 00 To place the clock in the program mode set the program switch located on back of clock in the upper left corner from NOR to PRO top position This now activates the 6 manual card positioning switches IN1 OUT 1 etc on top of the clock to function as program switches With the dust cover open you will find that these program switches a
14. eset to original settings by pressing the RESET switch on back of clock next to the program switch Doing so will reset ALL functions requiring the ATR120 to be re programmed e Press button one once If you are entering the programming mode to set or adjust the password press button one ten times The display indicates 00 00 e Press button four to choose the first two digits of the password You may use any digits from 00 to 99 OUT3 flashes in the lower right corner of the display e Press button five to choose the last two digits of the password You may use any digits from 00 to 99 OUT3 flashes in the lower right corner of the display e Press button six one time to save the password setting The flashing OUT3 disappears Once the password has been set when you enter the program the ATR120 will display 0000 The password must be entered and button six pressed then the time clock will display and enter program mode If the password is incorrect then the ATR120 will beep and Error Message E 40 is displayed You will not be allowed to enter the programming mode until the correct password is entered Exiting program mode When you have finished programming the ATR120 reset the program switch on the back of the clock to the NOR position and press button one once to return to the normal mode The ATR120 will now display the current time and date and is ready for operation VI Installing your ATR120 The ATR120 can be instal
15. he back of the ATR120 to the PRO position The display indicates 1 31 5 e Press button four once The display reads 2 1 The 2 indicates this is a weekly pay period OUT3 flashes in the lower right hand corner of the display This will flash until the changes are saved e Press button five to choose the current day of the week for your weekly pay period 2 1 Monday 2 2 Tuesday 2 3 Wednesday 2 4 Thursday 2 5 Friday 2 6 Saturday 2 7 Sunday e Press button six to save your settings OUT3 is no longer displayed For biweekly pay periods you must select the current day of week within the pay period Example if the current day of the week today is Monday you must choose which Monday the first 3 1 or second Monday 3 8 of the pay period e Enter the programming mode by setting the switch on the back of the ATR120 to the PRO position The display reads 1 31 or the last setting e Press button four twice The display reads 3 1 The 3 indicates this is a biweekly pay period OUT3 flashes in the lower right hand corner of the display This will flash until the changes are saved e Press button five to choose the first day of your weekly pay period 3 1 first Monday of pay period 3 2 first Tuesday of pay period 3 3 first Wednesday of pay period 3 4 first Thursday of pay period 3 5 first Friday of pay period 3 6 first Saturday of pay period 3 7 first Sunday of pay period 3 8 second Monday of pay
16. he next scheduled event 02 5 00 If you do not want an event to occur each day you may select the day s of the week you want the event to occur After selecting the minute the event will occur press button two At the bottom of the display the event indicator will be displayed and OUT 3 will be flashing As the top of the display SUN will be flashing To select SUN press button three or to advance to MON press button two Remember to use button three to save the day of the week Cycle between buttons two and three as 11 necessary to set the day s the event should occur on The event will occur on the day s shown across the top of the display It is recommended that a program chart be used to create a schedule to assist in programming this feature The typical company uses eight events similar to the previous example on page 11 Printin Printin Signal Print Red amp Print Black Red Black Signal amp Signal INI OUT1 IN2 INI IN2 OUTI IN2 Setting signal duration The ATR120 can be set to produce a signal lasting from zero 0 0 to sixty 60 seconds with the default being five 5 seconds e Press button one once If you are entering the programming mode to set or adjust of the signal duration press button one seven times The display should now read 5 indicating the signal will sound for five seconds e Press button five to change the signal duration The display indicates 5 with OUT3 flashing in
17. led in any normal office environment It may be installed on a smooth flat surface or wall mounted No special wiring is needed However 16 we recommend installing the ATR120 on a separate power circuit We do not recommend using a power strip Always follow basic safety precautions when using this product to reduce the risk of injury fire or electric shock Caution e Read and understand all instructions in the ATR120 User s Manual before installing and operating this time clock e Do not install the ATR120 in areas where it may be exposed to direct sunlight or high temperatures such as near a heater e Do not install the ATR120 where it may be exposed to excessive dust or to high humidity resulting in condensation e Do not use this product near water or when you are wet If the product comes in contact with any liquids unplug the electric cord immediately Do not plug the product back in until it has thoroughly dried e Securely install the time clock on a stable level surface or if wall mounting the ATR120 follow the wall mounting instructions to install it securely on the wall Place the time clock where no one can step or trip over the cord Do not place objects on the power cord that can cause damage or abrasion e If this product does not operate normally please consult the Troubleshooting section of this manual Wall mounting 1 Following the diagram insert a screw about 94cm to 124cm above the floor Allow ab
18. n OUT3 at 6 00 PM OUT3 1 0730 1200 1215 17 00 1730 18 00 1 EE EE e E Re Es 13 Use this chart to plan your Auto Column Shift times To program the auto column shift e Press the first button one time to advance to programming the auto column shift feature If you are entering the programming mode to adjust the auto column shift position you will need to press the first button eight times The display indicates 01 5 00 with all days of the week displayed 01 indicates the event sequence number 01 18 5 00 indicates the default time 5 00 AM of the event e Press button two to advance through column selections The column position INI OUTI icons will flash at the bottom of the display The day of week icons are displayed at the top IN1 First In Punch of the shift OUT1 Out Punch Lunch 14 IN2 In Punch Lunch OUT2 Out Punch end of shift IN3 In Punch Overtime Period OUT3 Out Punch Overtime Period e Select the column position by pressing button three The column position icon at the bottom of the display will stop flashing ALL days of the week will appear at the top of the display To select this move everyday of the week recommended press button six to select and to advance to the next column selection e Toselect certain day s of the week after pressing button three to select column position icon at bottom of display will stop flashing press button two and SUNday icon will flash a
19. out 1 8 between the screw head and the wall 5 47 1 8 j 6 61 gt 7 95 OD 17 A ES ols Following the diagram insert screws at positions B and C Place a screw anchor in the wall at position D Use the two screws M4X10 to attach the wall mounted frame to the bottom Wal mounting of the time clock Line up the keyholes on the back of the time clock with the screws in the wall Slide the ATR120 downwards to firmly mount it on the wall Place a screw in the bottom hole of the wall mounting frame to secure it to the wall Operating your ATR120 The Clock will print in the column indicated by the red light above the IN OUT buttons Press the appropriate IN or OUT button to choose the print position for time cards The print position will not change until another column button is pressed If an auto shift schedule is programmed then the ATR120 will automatically shift from column to column If manually changed while in auto shift the clock will return to the programmed position after 7 or 8 seconds In Morning Out Lunch IN Lunch Out End of Day OT In OT Out IN1 OUTI1 IN2 OUT2 IN3 OUT3 18 To print insert a time card into the receiver with the pay period selected facing you Note The clock cannot differentiate the pay period and will print on either side of the time card The card is automatically
20. perpetual calendar Password for program protection Package Contents Unpack the time clock and check its contents to ensure that it and all of the accessories shown below are included a Time Recorder b Manual Wall mounting diagram Manual Ea gt f Screw M4X10 2 d Screw and anchor e Wall mounting 4pcs each frame uns y g Battery gt eS Z E Z HI Location of Components Rear Cover 1 Anti dust cover 2 Time card receiver 3 In Out advance buttons 6 4 Analog clock Clock dial 5 Display 6 Program mode switch 7 Reset return to original factory settings 8 Wall mounting keyholes 9 Fuse access door IV Getting started Installing clock dial battery The front cover must be opened before the clock dial battery can be installed Opening the front cover also allows you to set the clock s analog time You will need to do this occasionally to synchronize the clock dial to the digital display and printer To open the front id two id cover turn the clock on its back and remove the two outer screws on bottom of clock Stand the clock upright with the back facing you With both thumbs press down on INI and OUT3 buttons while using your fingers to push cover away rad Press these areas J The clock dial panel is shipped locked into place You have the option of removing the tab that locks the clock pan
21. re numbered 1 6 to simplify programming the ATR120 The first switch on the top left of the clock IN1 functions as the feature selection switch and will advance you through the program mode This switch also allows you to skip over a feature and advance to the next feature without programming Once a feature is selected switches OUT2 through IN3 will be used for programming We ll refer to the switches as buttons one through six The last switch on the right button six or OUT3 is used to save the program selection to memory IMPORTANT If OUTS is flashing in the lower right corner of the display the programmed changes have not been saved IN1 OUT1 IN2 OUT2 IN3 OUT3 O O O O O O 1 2 3 4 5 6 Select Save Programming Switches gt When in the PRO mode To return to the original factory settings press the RESET button located to the left of the PRO NOR switch on back of the clock Note Each time you modify the program you must press button six to save the program changes OUT3 flashes in the lower right corner of the digital display until the programming change is saved If OUT3 is flashing in the lower right corner of the display the program changes have not been saved Selecting day of week The ATR120 can be programmed for either weekly or biweekly pay periods For weekly pay periods program the time clock as follows e Enter the programming mode by setting the switch on t
22. t top of display Press button three to select that day Press button two to advance to the next day Pressing button two without pressing button three will skip that day of the week Press button six to save selections and advance to next event e To select the hour for the column change press button four e To select the minutes for the column change press button five e Remember to press button six to save and advance to the next programming sequence Each sequence is programmed the same way Selecting how the hour will print The ATR120 will print hours in either 12 or 24 hour format e Press button one once If you are entering the programming mode to adjust the hour printing format you will need to press button one nine times The default setting is 24H e Press button four to toggle between 12 and 24 hour printing format 12H and 24H OUT3 flashes on the display e Press button six to save the hour printing format OUT3 no longer flashes on the display 15 Setting the password The ATR120 allows for the use of a four digit number as a password to protect programmed settings When the password is set you will be asked to enter it cach time you enter the programming mode It is recommended that if a password is used that you write it down and store it in a safe place If an incorrect password is entered you will be prevented from entering the programming mode Note If correct password cannot be entered the clock can be r
23. umn shift print position errar 13 Setting how the hour will print ccceccscecsseesseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenaees 15 Setting the ee a 16 Exiting program mode 16 Installing your ATR120 tos s o 16 Wall mounting cise cctee iced hone Tia wai a wa Re eee ees 17 Operating your ADR aaa 18 MALE ACE 19 Replacing the 19 IX Troubleshooting Location OffUses sc cabendo ses relata Te S E A ada E SSI AS Leio Sd ih 21 Error COJES 21 l Introduction Overview The ATR120 is an electronic across the card time clock which can be used for a weekly or a biweekly pay period The unique ATR121 Time Card offers a weekly time card on the front and a biweekly time card on the back The day progresses across the card from left to right in six columns This is accomplished by pressing one of the card positioning buttons IN OUT on top of the clock The pay period day of week moves down the card top to bottom You may select the time of day you want this day change to occur You may also select the starting day of your pay period during the easy set up procedure The ATR120 offers two color printing so employee punches outside normal punch times

Download Pdf Manuals

image

Related Search

Related Contents

Accelerated Interoperability & Troubleshooting HP Networks, Rev  KitchenAid KUIO18NNVS1 User's Manual  LIMPIADOR DEL SISTEMA DE ADMISIÓN 02 03 0140 Aplicaciones  Makita XLC02R1W Use and Care Manual  SC 1332  El servicio regular le ayudará a mantener su motocicleta H  Operating Instructions - ACS-CONTROL  取扱説明書 - オーム電機  LG 42PX3DCV User's Manual  Mounting and operating instructions EB 8222 EN  