Home

-LEGO`

image

Contents

1. LC 1 Irrigation timer User s manual ECO IRRIGATION EQUIPMENT LC 1 ASSEMBLY INSTRUCTIONS UPPER COVER CONTROLLER LOWER COVER 22 4 SCREWS MOUNTING BRACKET RELEASE LEVER MANUAL OVERRIDE ACTUATOR O RING Make sure you do not loose FLOW DIRECTION PLASTIC VALVE VALVE ASSEMBLY Screw the actuator clockwise until it reaches the bottom of the cavity NOTE small O RING Parker 2 006 must first be inserted as shown DO NOT USE TOOLS TO TIGHTEN THE ACTUATOR DO NOT OVER TIGHTEN IT Connect the valve assembly to the water line Make sure that flow arrow on the valve shows the right flow direction Once connected to the water system turn on the water to detect eventual leakage OPEN and CLOSE the valve with the actuator manual override Return the override to AUTO Please note you have to turn the red arrow all the way 180 to the desired position CONTROLLER ASSEMBLY for valve mounting only Connect the mounting bracket to the back of the controller using the 4 screws FINAL ASSEMBLY Place the controller assembly over the actuator until it snaps into position Make sure the actuator wire 15 ree and clear out of the bracket WIRE CONNECTION Do not remove the rubber plug on the bottom of the controller Use the hardened tip of the wire to punch a hole in it and thread the wires through Using a coin remove the lower cover and connect the w
2. will operate every 3d day To reset back to 0 press 74 amp simultaneously Press advance to the next program step a g5 pre BP 58 Press set the hours of the 1rst starting time for this station 25 set the minutes 4 A __5 Press advance to the next program step and program additional watering starts for this station on the same day Press E o advance to the next program step manual A i Press A o open the valve of the flashing station Manua Press 4 close the valve VW Press o to AUTO RUN OFF GENERAL INFORMATION Battery replacement As soon as the low battery indicator BATT flashes the 9V battery must be replaced After battery disconnection the program will remain in memory for 10 seconds until reconnection to the new battery Operating conditions The controller is designed for outdoor operation However it is recommended to place it in a protected area Keep the cover closed at all times In winter the controller can be removed from the valve and stored indoors for better protection Only the actuator wires should be disconnected By keeping the battery connected the program will remain in memory until reconnection of the controller Manual override The manual override allows you to open or close the valve mechanically The actuator 15 factory set on AUTO TO OPEN THE VALVE t
3. BUTTONS 1 NEXT STEP button Used to advance program steps 2 DAY STN button 3 HRS ON button Used to change HOURS or ON unction 4 MIN OFF Used to advance MINUTES or OFF unction ed Used to advance DAYS or STATIONS SET TIME DAY WATERING TIME DAYS ON OFF 5 CONTROL PANEL START 2 START 3 DISPLAY INDICATORS 5 DAYS OF THE WEEK 6 PROGRAM STEPS INDICATOR 7 BATT indicates low battery 8 STATIONS indicators 9 OFF The controller is in RAIN OFF mode 10 DAY CYCLE indicates irrigation programming by interval of days between waterings PROGRAM STEPS The display shows Do Press Dad to set today s day DAY to set present hour mu i Press to set the minutes Press FEY advance to the next program step 1 V Press P to set the hours of the watering duration for this station 2 Mi fe Press to set the minutes 0 30 L Press 24 to advance to the next program step a4 Press you not want to irrigate on the flashing day SE Press irri he flashing d 52 ress to irrigate on the flashing day WZ Press to stay with Press toselect your DAY the weekly 1 this station will program operate every day 8 Select 2 this station will DAY CYCLE operate every 2nd day Select 3 this station
4. ires the terminal blocks as shown below CONNECT THE BLACK amp WHITE wire to Plus and the BLACK wire to Minus BATTERY CONNECTION Battery not supplied Connect a 9V ALKALINE battery and place it into its compartment The display will flash 3 times showing all the segments followed by the OFF command resetting the actuators to the CLOSE position Close the lower cover WALL MOUNT Mount the unit on a wall by sliding the 2 slots found on the back of the unit over 2 screw heads place 90mm apart D WALL MOUNT 3 IMPORTANT INFORMATION The button leads you through the programming steps Ifyou are lost or wish to go to press Ladd continuously for a few seconds until display shows press again to advance to FCS Ue se which is the automatic running stage Press to start programming again Auto return If within minutes you do not touch any button the controller will automatically go to HRS MIN If you press A or A continuously the digits will advance quickly HRS MIN Setting reset if you press A and A simultaneously the digits will reset back to 0 Watering days can be programmed in two ways 1 You can identify the day of the week for watering SUN MON TUE etc 2 You can choose the number of interval between waterings a 2 day cycle means that the watering will take place every two days CONTROL
5. urn the arrow COUNTER CLOCKWISE 180 and return 180 i 80 it back to AUTO the valve is open to open to close TO CLOSE THE VALVE Turn the arrow CLOCKWISE 180 and return it back to AUTO the valve is closed TO LOCK THE VALVE If you wish keep the valve in either OPEN or CLOSED position keep the arrow pointed in 180 direction without returning it to AUTO in any of the 2 previous steps TO RESUME AUTOMATIC OPERATION return the arrow to AUTO Design and engineering LEGO IRRIGATION ISRAEL Printed in Israel Distributed by

Download Pdf Manuals

image

Related Search

LEGO` lego legoland legoland california legoland tickets legoland hotel lego star wars lego store lego ideas lego sets lego builder legoland water park lego batman lego spike lego games lego movie lego flowers legoland san diego lego ninjago lego instructions lego fortnite lego technic lego videos lego pick a brick lego jurassic world legoland florida

Related Contents

  Owner`s Manual  ViridianX5LGen2Manua.. - Viridian Green Laser Sights  User`s Manual - Projector Central  Manual del usuario  

Copyright © All rights reserved.
Failed to retrieve file