Home

Ammonia Nitrogen, Nitrate-Nitrite Nitrogen

image

Contents

1. SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014 SWI 12 01 Using the DailySolids xls Spreadsheet SOP 12 Solids Page 8 of 11 Prior to July 2013 one criteria limit was applied to all duplicates regardless of the test and only one limit was applied to all certified reference material Individual limits criteria is now applied to individual testcodes for Duplicates CRM amp Repeats These values reside on a hidden worksheet in the DailySolids xls workbook and are reviewed updated every 2 years or whenever the method validation data is calculated Supporting Work Instructions Analytical Services Branch Environmental Standard Division CTYPE TestCode QClimits DuplSmpl TDSwv 10 0 DuplSmpl TSSwv 11 0 DuplSmpl TS 7 0 DuplSmpl TSwv 7 0 DuplSmpl TVSwv NQC DuplSmpl TVS 4 0 DuplSmpl TVSSwv 11 0 DuplSmpl TVSS 11 0 RefMat TDSwv 9 3 RefMat TSSwv 11 0 RefMat TS 11 0 RefMat TSwv 11 0 Repeat TDSwv NQC Repeat TSSwv 6 0 Repeat TS 7 0 Repeat TSwv 60 Repeat TVSwv 6 0 Repeat TVS 7 Q Repeat TVSSwv 6 0 Repeat TVYSS NQC Currently only the Quality Assurance Officer can unlock and change these values If for some reason the hidden worksheet is removed from the workbook the following VBA Program error will occur Reportit to the QA Officer immediately Microsoffwisual Basic Run time error 9 Subscript out of range Add Comments In order to import the data and QC into the LIMS the comments must match those in
2. 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 2 of 11 TapE OF CONCOS ses ce seccnddurcva came sscecouesndannedsausbusleeue teaauiecueidinee eeetesecesudaannsasadiecosncoseue 2 PE OGU ClO iccsvcsutasncatuvenssciadas A E EER 3 User Name wwdanalySt sdcivncosersderdoianccndedsanstanenstieannsaosuamanstetamscannneeiaaameesenneeeuanaanens 3 IND OTN Ga the Baten aaiecsstsiarkvoensasdsawanesranteaeeenssaciariadeediiadenasious T 4 Add GO Tie Saline IB AUC nren E E EEEE 4 ON OG BUN GOR cc strewmrcccnnteerdiesecettendneciesnnetbesnessanectsecennee dene EEE AEO 5 DIEE EE AAI EO T T T T E E T E E T 5 Repeat Reweigh ssssssesssssssssnsnensrnrnrennnrnrrernrnennrnrnrnnrnenrrnr rnrnrnrnnrnenrnnrrrurrnrnne 5 SIDE DINE eare E E ee ee ee ee ee eee 6 CRM OF FRM siancsaasaseoecenasantahserstenuspameaidacesianieaesataoressauaedede Mice AEE 6 SCL HOLM Gla accavasactearisanpeanasa vie ntaansge a a Eten nane eersapiacsveerinarert nits 6 Sample 6 a a ee oh ee rrr 7 EV AW CVO eiin E a Be a 7 iia ceaue nidet eters ances teases 7 OA OC CaCO AUOF erre E a vanes A a oe seareneneeee O 7 Control Limits and OC Calculation wivssiscitedics Aiii anarei Enin ikae AANE E aa 7 Add COMMENT ririciriisrerrini naia aa a aa aa E aai 8 PRING CO FOIGGK sapisssttqectisssorciaarineagbetaceaid T a N a En 9 Deleting Cleaning the Folders Nernst ccsceccceecesscusnneeneeeeessecusnaneeeeent
3. Batch is sent to the folder as a backup historical data Deleting Cleaning the Folders Delete Files from Folder A function has been added that will automatically delete all files from any of the Folders selected in the Import Export Form Simply select the folder and select the delete button The application compares the last modified date with the current date and deletes all files more than 7 days old File Recovery If a batch was already printed Print to Folder then a copy of it is in the monthly log Open the monthly log select the batch right click on the tab and move to DailySolids xls spreadsheet If the icons or row 8 of HomePage is copied in the batch then the functions can be reused SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions Analytical Services Branch Environmental Standard Division SWI 12 01 Using the DailySolids xls Spreadsheet SOP 12 Solids Page 10 of 11 Every time a batch is loaded the workbook is automatically saved The workbook is also set to Backup which forces a backup copy to be made by both the user or by the automated program An additional copy is also made every time the program is closed called LastSaveBeforeClose xls and a copy goes on the C drive In the event that the network is down users can log onto the local PC drive C and continue using the spreadsheet The user will have to automatically save a copy to G drive when t
4. This opens the Solids Import Export user form in Figure 1 Select the Folder that the Batch was created in from the Batch km Creation Process NEWPCC SE amp WE Solids I X All the Batches in that folder will be listed in the drop down S lect the Folder list If your batch is not listed YOU HAVE SENT IT TO oC NEWPCC Waters ANOTHER FOLDER See LIMS USER MANUAL to change the n a N r default location when creating batches j ER E Ii Select the batch from the list and double click the selection You will then be prompted yes or no to continue withythe download A new worksheet will be created in DailySolids xls workbook and named according to the batch name You will then have the option to delete the batch from the Folder Yet FileImport To Import Batch Select Batch and dbl click C Add to the Same Batch Delete Files from Folder Deleting Batch Files 2 Do you want to DELE fe Batch glT est lg Exit Figure1l Form Solids Import Export Add to the Same Batch Create the first Batch and load it into the DailySolids xls program as described above Create the second Batch with the same Batch Name and extension Send it to the section folder Select the Add to the same Batch option and select the Folder where the Batch was sent to Select from the drop down list and double click You can add as many batches as you wish as long as they are named the same If the B
5. guidelines only IW Average This function is for TSSavg testcode only which issused for the Industrial Waste samples This function compares the values from 2 3 samples one result and two duplicates calculates and enters the average of the closest two values and highlights the third number with the comment Not used in calculation In addition the Job Number and TestCounter are removed and the QACode in column 4 becomes empty When the results are imported into the LIMS these results do not get entered into the LIMS even though they appear on the spreadsheet QA QC Calculator The reason for building the QA directly into the spreadsheet is to catch the errors before it s too late Refer to the Solid Method for corrective action This function calculates the RangeRatio of the Duplicates and Repeats reweigh compares it to the established control limits of 3 standard deviations and inserts a comment If the QC fails corrective action can be taken immediately Redo the test reweigh etc RangeRatio is the Result Expected Result which is the DupISmple Result The target is 1 0 Sample blanks are also calculated and compared to the control limits The Minimum Detectable levels is set at 4 mg L therefore the SmpIBlank should be O mg L 4 mg L CRMs and HRMs are calculated as Recovery 100 is the target and are compared to the established control limits of 3 Standard Deviations Control Limits and QC Calculations
6. Q City of Winnipeg Environmental Standards Division Winnipeg Analytical Service Branch Supporting Work Instructions Parent SOP 12 Solids Procedure ID SWI 12 01 DailySolids Revision Date March 3 2014 Total Pages 11 Authorized By Steve Fletcher Supervisor of Analytical Services Notice Only one printed control copy is issued and is located in the Analytical Services Laboratory The controlled copy is signed and dated by the Supervisor of Analytical Services Only the Controlled Copy Documentation is to be used in the laboratory This controlled copy cannot be photocopied or reproduced without authorization Electronic copies are accessible in PDF format from an intranet folder N Environmental Standards Analytical Services SOP PDFs and the method folder Hyperlinks to external documents highlighted in green font are functional in the electronic version of this document when the user has permission and the document is viewed within the City of Winnipeg s intranet site and the above mentioned folder Latest revisions are highlighted in blue print All hand written amendments except for spelling or grammatical errors must be approved immediately by the Laboratory Supervisor or Quality Assurance Officer who shall initial and date the amendments The procedure shall be formally revised and reissued as soon as practicable SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12
7. atch name is different the Import File function in the LIMS will not work SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 5 of 11 Additional buttons on the form are visible above the Exit when the form is opened from any other worksheet other than the HomePage SE amp WE C Iw ee 04 QC Batch Builder Select the Folder C FileImpor zhi Select this button to add the QA QC to the worksheet instead To Import Batch _ Of building it in the LIMS Make sure you have the CRM or Select Batch and dbl click HRM Reference number and certified expected values before oOo B continuing 0 Add to the Same Batch oe You can also load the QA QC BatchBuilder by double clicking ReformatHomePage the cell that has the following Delete Files from Folder Form Sample No 385828 lt lt lt lt ae QA QC Batch Builder The following blue form WEP gee appears Blue color Print to Folder may vary based on the operating system and Exit default window settings Duplicate Select the sample n column C with the QACode Result and select the Duplicate button on the QA Form Before Selecting the button verify that you have the correct sample by checking the Sple displayed in the form caption to the left
8. e spreadsheet The QC is calculated based on the control limits set in the method validation and from the Consensus values of the Certified or House Reference Material The program does not keep track of all the QA If there are any discrepancies with the LIMS the LIMS is correct because it is always updated with the latest QA results The spreadsheet serves more as an early warning signal of problems with the batch At that stage corrective action can be taken immediately so that the data is still reportable DailySolids xls is a Microsoft Excel workbook and all default Microsoft functions apply For example Excel does not allow two worksheetsato have the same name If you use the same batch number in this workbook you will get an error message that is not related to the Visual Basic Code that resides within this application All users must have basic knowledge of MS Excel prior to using this workbook There is no active code or Visual Basic running when the program is used Almost all code is activated through one of the buttons on the form or double click event programmed into it If an error code occurs please right down the error message orerromeode number for further assistance Note The user forms and functions may differ slightly from those shown in this manual Upgrades are frequently done to improve and expand the functionality of the DailySolids xls All programming is i Visual Basic for Applications VBA and written by the a
9. esggnnaanes 9 Fle RECOVETY ririoneiirirsrsresiriner ys a a aar niner Tn rE 9 Reformatting the Home Page Gey Ry ccccccccscccsseecceeceescceseeeerteessseeuuaaeeeeeenteeggeeaantes 10 SOM Wale Wedge srine r ania TE ERE 10 PERELE E c T sna E E E E A E E 11 Referenced Text and MAMAE ccc ccccccescccsccnseneeeeeensececneatreeeessecuunneeeeeentesgggeaantes 11 REVISION FUSCOLY acres Wes N E S AA EE TA 11 pice ET See TTT ETE ETT E T T 11 SWI 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 3 of 11 The DailySolids xls is an excel workbook with a spreadsheet used for recording calculating data evaluate Batch QC and flag non conformance on the Solids Methods Total Suspended Volatile and Dissolved Through user forms and programmed functions the batches created from the LIMS Batch Creation process are imported into the spreadsheet The Batch QC is also created from the spreadsheet instead of the LIMS When the Batch Data is complete a file is then created into a standard format that allows importing the results and quality control data into the LIMS A copy is also created into a monthly folder This Application Method describes all the functions and procedure for using the spreadsheet The program uses WinWedge to capture the weights from the analytical balance directly into th
10. he network is up and running The users should make an additional copy for themselves or print it out Reformatting the Home Page A new function has been added to the Import Export form For this spreadsheet to work efficiently it s important that the HomePage retains the exact formatting Rows or columns Should never be added to the HomePage nor should any additionalinformation words or numbers be included added The HomePage is correct when there are six empty rows the word Batch is in cell AZ and the word END is in cell AA7 Selecting the Reformat HomePage will add all of the Headings text lines and color scheme Opening the DailySolids xls workbook should automatically open WinWedge if not then do the following Open the software wedge WinWedge and double click the Zoom In and OUT cell that has the following Figure 9 Zoom room In and Out This will change to an expanded view and the row that you re in will be highlighted in blue making it easier to follow The cursor will automatically go to the first empty cell in the yellow column Figure 10 Balance View SampleNu mber 106499 106499 106499 106499 106501 106501 E m m m h SWI 12 01_DailySolidsWksht doc SampleName Best Brand Meats Ltd Best Brand Meats Ltd Best Brand Meats Ltd Best Brand Meats Ltd Rothsay Rothsay Sample Volume mLs 20 20 20 20 Zu Vessel ID 30 Ve
11. of lt lt lt lt above and the name above the buttons These correspond to the sample row that you selected TONOA D ar sample Nu 1 JobNumber mber sampleName QACode TestCodel 44 36223 3650920 VW Mixed Liquor Result TSSw F Repeat Reweigh Select the sample and select the Reweigh button and the sample reweigh will be inserted directly below It will have the QACode Repeat SWI 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 6 of 11 Sample Blank The blank or DI Water will appear directly below the sample that you select CRM or HRM This program works independently from the LIMS and is not connected to the LIST of CRMs The next three screens are to enter the information which appears in a drop down list in the LIMS Batch QC Builder When you select the CRM you will be prompted for the following information Certified Reference Material OF Enter the LIMS CAMH ok for Total Suspended Solids 1 for Total Solids for Total Disolved Solids Since the CRMs have different values for Suspended Total and Dissolved Solids you must select one of the options to assign the correct TestCode i e TSSwv or TSwv or TSwv Zero is the default value and most widely used TSSwv so you can select OK without changing the n
12. ssel Wt g 18 065 17 7172 17 9639 ffl fe 15 1962 16 0566 a7 Sass Vessel amp Sple Wt 8 15 0696 ee 1 S6BS if eeu 16 0814 a7 Sass Sample Wt g 0 0039 0003F 0 0033 0 0037 0 0031 U 0053 aan ana Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 11 of 11 Zero the analytical balance and then place the vessel gooche onto the balance Select the send keystroke on the balance and the weight will be entered in the active cell in the spreadsheet When the weighing is completed select the balance icon again to resume the normal view and deactivate the colored rows Referenced Text and Manuals SOP 12 Solids Total Suspended Volatile amp Dissolved SOP 50 section LIMS Batch Creation Process amp File Import Procedure Balance Manuals located in balance room History Original Version April 13 2005 Version2 Skipped mS Sepiginibeh 10 2010 Current Version 5 New format and SWI 12 01 formerly SOP 81 Includes separate criteria for calculating Duplicates Repeats and CRM recoveries Updated forms and include Error Message SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014
13. the LIMS Double click the following cell to open the Comments Form SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 9 of 11 Open Comments Form The drop down list has been shortened to include only the Comments appropriate to this method Add Comments and Result Codes Sample 106499 Best Brand eats Ltd Result Codes Enter Exit WN Result Select the sample in column c that you want to add a comment to Select from the dropdown list add other comments in the first box and select the Enter The result code is a negative numerical value 99 Print to Folder After the Results are complete calculated resultsrand QA select the Open Batch Import Export Form and select the Print to Folder A file will be created in the wwdanalyst g FileImport The file will have the same name s the original Batch filename and extension Log into the LIMS under your owngusername select the Enter Results by Computer File and type in the path and extension Ex g FileImport gl50410s xls Note the Batch name appears on the worksheet in last row of column B Monthly Log On the first day of the month when a batch is printed to folder a new monthly folder is automatically created in the Solids Data folder in the wwdanalyst G drive A copy of every
14. umber The next prompt follows Expected Yalue 4 Enter the Expected Value for Siwy Cancel Get Formula Select this button to enter the formula into the spreadsheet The formula is dependent on the testcode If a sample volume is required and has not been entered yet you will be prompted for the volumes SWI 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 7 of 11 Sample olume mg L 0K Enter the Sample Yolurne for _ OK 106499 Best Brand Meats Ltd _ Cancel m Sample Volume It is easier to enter the sample volumes directly into the spreadsheet first Exit the user form enter the volumes and then return to the Get Formula button If you cancel the above prompt the date analyst code units and the formula in the second last column on the right is still inserted You will not have a formula in the Analytical Results column This is a safety measure to ensure that a volume has been entered in order toget a result Sample volume is dependent on the amount of sample that iSefiltered Entering the sample volumes for each sample as compared to preset values actually reduces operator errors Preset volumes are usually taken for granted and carnveasily be forgotten when a different volume is used Any recommended sample volumes in the method are
15. uthor Comments and suggestions for improvements are greatly appreciated In order for all analysts to use the same program a generic user named wwdanalyst was created This allows the programs DailySolids xls PipetteCal xls etc to reside on the wwdanalyst G drive which serves two purposes You can logon any networked computer as wwdanalyst and logon the LIMS under your own username This allows you to create batches directly into one of the following folders labeled by work section NEWPCC SE WE WPCC Industrial Waste and Water Resources The batch can be imported from these folders into the DailySolids xls using any network computer in the laboratory In addition back ups are automatically and routinely created so that there is a minimal chance of losing data You only need to use the balance computer when weighing because the balance is connected via RS232 com port connection with the computer SW1 12 01_DailySolidsWksht doc Date Printed 3 3 2014 Supporting Work Instructions SWI 12 01 Using the DailySolids xls Spreadsheet Analytical Services Branch SOP 12 Solids Environmental Standard Division Page 4 of 11 Note Some of the colors of the forms shown in this document may vary due to the computers default display settings and theme To import the batch information Select the worksheet named HomePage Open Batch Select and double clicked the Open Batch Import Export cell DE ee

Download Pdf Manuals

image

Related Search

Related Contents

Pressostat/type I.L.S. Nouveau  ・仕様 ・圧力損失    Sony VPCZ11FHX Marketing Specifications  La technique sous sa plus belle forme  Istruzioni Combi - Systec Therm AG  K334 - カーメイト  京都府福知山市花火大会での火災事故を受け  Kaba elo Programmer  

Copyright © All rights reserved.
Failed to retrieve file