Contents
1. cable 4 pin Rj765 cable 10 Rigging the TLD 612A WARNING Always secure an elevated TLD 612A with a safety cable as backup The TLD 612A may be installed in any orientation Before installing TLD 612As at elevation ensure that the Attachment hardware is in good condition and designed to support at least 10 times the fixture s weight Structure can support at least 10 times the weight of all installed fixtures Work area below is blocked from public access and make sure the work is performed from a stable platform When using more than one TLD 612A to create an LED curtain ensure that the TLD 612As are installed so that the correct pixel pitch can be achieved Min 160 mm Max 500 mm To rig a TLD 612A 1 Loosen the mounting brackets and slide the brackets to the desired length no less than 160 mm and no more than 500 mm apart 2 Turn the thumb screws fully clockwise until the bracket is locked in place 3 When using more than one TLD 612A to form a wider LED curtain 11 12 the fixtures need to be spaced 6 mm apart to obtain the correct 12 cm pixel pitch Connect and arrange the power and data cables Fasten the TLD 612A securely to a fixed surface or structure ensuring that the supporting structure and or hardware used can hold at least 10 times the weight of all the devices they support as well as all installed accessories If suspended from a rigging struc
2. D 612As can be configured and controlled when daisy chained together and connected to a computer using an Ethernet cable and up to five TLD 612A s per port can be daisy chained when one or more Ethernet switches are used TLD 612As can be configured using the SGM Artnet Configurator available from http www sgmlight com and controlled using a lighting controller or computer based Artnet controller Unpack the device and inspect it to ensure that it has not been damaged in transport The fixture is IP 65 rated This means that it is protected from ingress of dust and lower pressure jets of water from any direction Mounting bracket left Mounting bracket right Cabinet Connections moo WO gt LED pixel outputs from 1 to 6 rows Illustrated by LED Balls Cabling and connections Power in Data Data indicator indicator Power out Output 3 ethernet connector for artnet Output 1 Output 2 Output 4 G Output 6 RJ45 ethernet connector for artnet Output 5 The following connectors are used on the TLD 612A IP67 rated RJ45 Ethernet connectors for artnet input and output 3 lead power cable for power input and output with CEE cord caps 6 x RJ765 output connectors supply 12V DC power and data to the LED products RJ45 Power in RJ45 ethernet ethernet connector connector for artnet EO Artnet In
3. TLD 612 2 7 Artnet Pixel Driver TLD 612A dimensions All dimensions in mm Drawing not to scale TLD 612A USER MANUAL REV 2 2014 SGM Information subject to change without notice SGM and all affiliated com panies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are trademarks owned or licensed by SGM or its affiliates or subsidiaries English edition Contents Ml nee DT 6 qui YO Y X E X s 8 Caping and CONMNMECUONS ee ee te 9 Rigging the TLD 612A ins 11 Connecting AC DOWEr TTC 13 CGONNECUNO LED DIOS Se see ae eee ne 15 Configuring the device using an Android telephone via RFID 16 SEINE HT 17 SPECH EAU 1S asar i 18 Safety information WARNING Read the safety precautions in this section before installing powering or operating this product The TLD 612A is intended for professional use only It is not suitable for household use Review the following safety precautions carefully before installing or operating th
4. VAC 13A up to 8 TLD 612As can be daisy chained 115VAC 13A up to 4 TLD 612As can be daisy chained Power in Power Power link out link out Power out power connector 14 Connecting LED pixels The TLD 612A can drive six SGM LT 100s six SGM LT 200 or six strings of SGM LED Ball pixel luminaries each string can contain up to 56 led balls or any combination of the three product types These can be attached in any arrangement to the six output connectors on the TLD 612A The six LED pixel connectors on the TLD 612A are not designed to bear loads Always ensure that any attached LT 100s LT 200s and LED Balls are supported by other means than attachment to an TLD 612A connector 15 Configuring the device using an Android telephone via RFID As an alternative to connecting the device to power and using the SGM Artnet Configurator one or more TLD 612A devices can also be configured wirelessly via RFID using the SGM Tool app available from the Google Play Store installed on an Android smart phone that has NFC support ISO 15693 and ISO 18000 3 mode 1 compatible operating on 13 56 MHz 7k Hz carrier frequency 16 Service There are no user serviceable components inside the device Do not open the TLD 612A as doing so is likely to damage its ingress protection Consult your SGM dealer if the device operates abnormally is defective or otherwise in need of service or repair Upgrading the firmware We reco
5. e device Preventing electric shock N DANGER Risk of electric shock Do not open the device Do not open the device there are no user serviceable parts inside Ensure that power is cut off when wiring the device to the AC mains supply Ensure that the device is electrically connected to earth ground Do not apply power if the device is in any way damaged Do not immerse the fixture in water or liquid e Use only a source of AC power that complies with local building and electrical codes and has both overload and earth leakage protection Never attempt to bypass the fuse Always have defective fuses replaced with ones of the specified type and rating Verify that the power feed cable is rated for the total current draw of all daisy chained products WARNING Take measures to prevent personal injury Install only in a well ventilated space Do not paint cover or modify the device e Take precautions to prevent injury due to falls when working at height e Ensure that the device is always securely fastened with suitable hardware e For elevated installations always comply with relevant load dimensioning and safety standards and requirements Overview The TLD 612A is an Artnet pixel driver that can be used to drive six SGM LT 100s six SGM LT 200 or six strings of SGM LED Ball pixel luminaries each string can contain up to 56 led balls or any combination of the three product types Up to five TL
6. mmend that you to keep your device s firmware current Visit http www sgmlight com to obtain the most up to date firmware To perform firmware updates you need an SGM USB uploader cable P N 83062011 a Windows based personal computer and the SGM Artnet Configurator available from http www sgmlight com 17 Specifications PHYSICAL Length x width x height TTE 715 x 80 x 182 mm 28 2 x 3 2 x 7 2 in ji A E re Ne A 4 kg 8 8 Ibs CONSTRUCTION OS ae ae AE en I ae A dr eee E E TA Aluminum CS T MTM Black electrostatic powder coating INSTALLATION DEEE PEE AEE de en PEE EE a eee Any Minimum distance to combustible materials nina nine REI UU DEA E MEE dI SR 50 mm 2 in Distance between adjacent TLD 612As if pitch is to be maintained ooocccccccoonnccnnnccononccnnonononanonnnnnnnnancnnnnnnos 6 mm AMBIENT OPERATING CONDITIONS Maximum ambien Temperature o MM nnn 40 C 104 F Minimum ambient temperature 1 ee nest ee eee 10 C 14 F OPEL AUNG HEIM Rome 100 PP AO IP 65 18 PROGRAMMING AND CONTROL o D E ti ot S via PC running SGM Artnet Configurator Control of attached LED pixels via Artnet with three DMX channels per LED pixel SOWAS Upgrade zn via PC running SGM Artnet Configurator Wireless interface via RFID using an Android telephone that has NFC support and SGM Tools app Firmware UDC Ate Satriani iia via SGM USB
7. ture fasten the TLD 612A to a rigging clamp with an M10 bolt using the top hole in the mounting bracket Complete the rigging procedure by securing the TLD 612A with a safety wire using the hole in the mounting bracket This safety wire must be approved by an official body such as T V as a safety attachment for the weight that it supports The safety wire must be capable of supporting a static suspended load that is ten times the weight of the fixture Connecting AC power The TLD 612A can operate on any 100 240 V 50 60 Hz AC mains power supply Pre mounted CEE connectors are for protection only and should be replaced with a connector that meets local standards For temporary installations install a grounding type earthed industrial 3 pronged type B plug that complies with IEC 60309 or a comparable national standard and is rated 16 A minimum and use corresponding power outlet sockets Follow the connector manufacturer s instructions and all locally applicable laws and electrical safety codes For permanent installations have a qualified electrician hard wire the TLD 612A to the AC mains supply The device must be grounded earthed and be able to be isolated from AC power The AC power supply must incorporate a fuse or circuit breaker for fault protection 13 Daisy chain power to other TLD 612As When daisy chaining TLD 612As using the cables that are pre installed in the TLD 612A 230
8. uploader cable P N 83062011 CONNECTIONS Artnet data input output 2 x IP67 rated Avnet Abacus RJ 45 female sockets P N BENRJS 5EPFFJ SC7002 Pixel luminaire connections 6 x RJ765 connectors compatible with SGM LT 100 LT 200 and LED Balls ELECTRICAL PRO T ae aa a ee co ee E 100 240 V 50 60 Hz Maximum total power consumption full load ss 320 W Standby power with all outputs Off ae sa a ane ne ben mme an ipa eee 55 W Maximum standby power with no 1040 ii an 5 W FUSES Main fuses not user replaceable iris eeeeeeenensnnne 2 x T12A Power supply fuses not user replaceable ss 2 x T3 15A 19 TYPICAL POWER AND CURRENT ON o O 310 W 1 36 A 0 99 PF A5 E ADU C 310 W 1 30 A 0 99 PF APPROVALS sry pe EN 60950 1 ENG ee NER EN 55103 1 EN 55103 2 Specifications subject to change without notice 20 USER S NOTES 21 22 23 46GM SGM A S Soeren Frichs Vej 51 53 DK 8230 Aabyhoej Denmark Tel 45 70 20 74 OO info sgmlisht com vvvvw sgmlight com
Download Pdf Manuals
Related Search
Related Contents
King Canada KC-3105C User's Manual Fiche technique DEPRO SOLAGRIP D E F E I ES 古賀 琢也 の 取扱説明書 自己紹介編 manual de utilização do sistema online de apuração de pesquisa Insignia NS-LCD27FS Flat Panel Television User Manual Istruzioni per l'uso GIR Titan-Hyperion User manual Navigation Computer mit TS Software Dell PowerEdge R720 und R720xd Benutzerhandbuch Copyright © All rights reserved.