Home

USER MANUAL - Conference Room AV

image

Contents

1. Figure 10 Cable Pass through Insert P N 80 000399 9 7 Adjusting the Height of the Inner Frame If needed you can adjust the inner frame height to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers 2 Raise or lower the inner frame to the required height insert the screws and tighten them in place 6 Using the TBUS 1AxI Once the TBUS 1Axl is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 11 Video Conference Communicatio TBUS 1AxI Display Kramer i Switcher Ethernet Scaler 33333333 3 gt gt gt gt 33 gt 3 3 Ethernet M VGA 4 A Computer Graphics ea GP Power Amplifier Source Laptop Projector with Speakers Figure 11 TBUS 1Axl Boardroom Installation TBUS 1Axl Using the TBUS 1AxI KEN 7 Technical Specifications of the Assembled TBUS 1AxI POWER SOURCE Single Socket Assemblies AC power limits Universal 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs
2. AC 50 60Hz 5A Maximum 5A per power outlet Dual power sockets are used for TBUS 1Axl with two or four power sockets Dual Power Socket Assemblies Power Specs Universal TS 2U 80 001899 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet USA TS 2US 80 001999 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Germany and EU TS 2DE 80 002199 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet France TS 2FR 80 002299 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet TS 2IT 80 002399 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet TS 2AU 80 002499 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet TS 2IL 80 002699 220V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet South Africa TS 2ZA 80 002599 ki amp 220V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet TBUS 1AxlI Your TBUS 1Axl Enclosure 4 4 Power Cord Options You can order any of the following power cords to use with a modular TBUS Power Cord Type Description P N eWT10V North America CACIUS 110V eW125V apan CACIP 1250 6f220V Europa CACIEU 20V ev250V UK CACIK 250v erasov India C ACIIN 50V tU250V 10A China C ACICN 250V tU250V10A South Aca C ACIZA 250V To use one power cord for a 4 socket configuration you can order any of the following types of power cords separately Power Cord Type Description P N 110V Y
3. bracket grooves on both sides of the unit see Figure 2 item 7 4 Verify proper alignment of the unit before tightening the mounting screws 5 Tighten both mounting butterfly screws upward until they reach the table surface from underneath Tighten firmly see Figure 9 6 Tighten the locking butterfly screws downward until tight against the mounting bracket Figure 9 Inserting TBUS 1Axl into the Prepared Opening 5 5 Connecting the Cables When replacing blank inserts with connector inserts for example VGA audio HDMI and so on 1 Insert the cables to their appropriate connectors from underneath 2 Secure the cables to the tie holes on the TBUS 1AxI Do not secure the cables too tightly or too loosely Leave a small amount of slack 5 6 Inserting the Pass through Cables To insert the pass through cables for example to connect a laptop do the following 1 Remove the two screws attaching the split pass through bracket Remove the split grommet Insert the cable through the rectangular opening Open the split grommet slightly and insert the required cables Place the split bracket around the grommet and position this assembly over the inner frame Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure
4. including power sockets for the USA Germany the Europlug Belgium France Italy South Africa Israel and Australia A Universal socket for general use is also available see the compatibility restrictions in the table below The Single Power Socket Assemblies Power Socket Power Specs Type Universal TS 1U 80 000899 100 240V AC 50 60Hz SA Maximum JA per power outlet Power Specs Power Socket Type USA TS 1US 80 000999 100 240V AC 50 60Hz 5A EE Maximum 5A per power outlet Germany and EU TS 1DE 80 001299 100 240V AC 50 60Hz SA Maximum 5A per power outlet Belgium and TS 1FR 80 001399 France 100 240V AC 50 60Hz SA k k Maximum 5A per power outlet South Africa TS 1ZA 80 001699 100 240V AC 50 60Hz SA Maximum 5A per power outlet TBUS 1Axl Your TBUS 1Axl Enclosure Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not compatible with South African plugs Power Socket Power Specs Type TS 1IT 80 001499 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TS 1AU 80 001599 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TS 1IL 80 001799 220V
5. inner frame power socket assembly power cord and other inserts for the TBUS 1Axl enclosure are purchased separately 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables Go to http www kramerelectronics com to check for up to date user manuals a complete list of Kramer wall plates and module connectors application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer TBUS 1Axl away from moisture excessive sunlight and dust 2 2 Glossary Inner frame The inner frame fits into the TBUS enclosure Universal socket The Universal socket fits almost all power cords worldwide Insert The insert is fitted in the inner frame Go to our Web site to check for a variety of single and dual sized inserts 3 Overview The TBUS 1Axl is a modular furniture mounted connection bus enclosure that is easily installed
6. into a table or podium top Once assembled the TBUS 1Axl lets you connect any equipment to the room s presentation system installations via cable access or passive interfaces see Figure 1 When the cables are not in use they can be stored inside the unit covered by the lid and out of sight In addition the TBUS 1 Ax features e A modular design letting you tailor the TBUS 1Axl according to your requirements e A black anodized or brushed clear aluminum lid with a special opening for cable pass through note that other customized colors can also be ordered e Height adjustment screw holes to set the inner frame ordered separately to the desired height e Single or dual power socket openings that are suitable for any of the following power sockets for the USA Germany the Europlug Belgium France Italy Australia Israel South Africa or Universal for use anywhere see compatibility restrictions in Section 7 Order the power sockets separately from Kramer Electronics Figure 1 TBUS 1Axl inside a Table Do not place heavy objects on top of the TBUS 1Axl TBUS 1Axl Overview EI 4 Your TBUS 1Axl Enclosure SS lt SSsgss VSVSVsSsess Figure 2 TBUS 1Axl Enclosure Top View Feature Function 1 Black Anodized Brushed Includes an opening for cable pass through covers the inner Clear Textured Lid frame leaving the table surface neat and tidy 2 Outer Rim Fits over the table surface A p
7. power cord Specifications are subject to change without notice at http www kramerelectronics com LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below What is Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will n
8. KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 1 Axl Table Connection Bus P N 2900 300055 Rev 3 TBUS 1Axl Quick Start Guide This page guides you through a basic installation and first time use of your TBUS 1Axl For more detailed information see the TBUS 1Axl user manual and modular instruction sheets You can download the latest manual at http www kramerelectronics com Step 1 Check what s in the box A TBUS 1Axl Table Connection Bus Enclosure Kf 1 Cut out Template M 2 table clamps A 1 Quick start guide AH 6 self locking ties AH 1 User Manual Step 2 Prepare the TBUS 1Axl for mounting Step 3 Prepare the table for mounting Cut out an opening in the table using the cut out template Step 4 Install the TBUS 1Axl to the table Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Glossary 3 Overview 4 Your TBUS 1Axl Enclosure 4 1 TBUS 1Axl Optional Inner Frames 4 2 TBUS 1Axl Accessories 4 3 Power Socket Options 4 4 Power Cord Options 5 Installing the TBUS 1Axl 5 1 Assembling the Inner Frame 5 2 Installing the Inner Frame 5 3 Cutting an Opening in the Table 5 4 Inserting the TBUS 1AxlI through the Cut Out Opening 5 5 Connecting the Cables 5 6 Inserting the Pass through Cables 9 7 Adjusting the Height of the Inner Frame 6 Using the TBUS 1Axl 7 Technical Specifications of the Assembled TBUS 1Axl Figures Figure 1 TBUS 1Axl
9. ONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the o
10. be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If it is decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTR
11. f this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product How to Obtain a Remedy under this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will
12. gers to bring the inner frame to the desired position screw and tighten it in place using the height adjustment screws supplied with the inner frame Inner frame kits come with assembly instructions 9 3 Cutting an Opening in the Table To cut an opening in the table 2 Place the included cut out template that is included with your TBUS 1Axl on the surface ofthe table exactly where you want to install the TBUS 1AxI Attach the template to the table with the included screws if using the cut out template Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 8 not to scale The thickness of the table should be 76 2 mm 3 inches or less 152 2mm 191 2mm Figure 8 Cut out Dimensions 4 Unscrew and remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale template from our Web site Kramer Electronics is not responsible for any damage caused to the 5 4 Inserting the TBUS 1Axl through the Cut Out Opening To install TBUS 1Axl in the opening 1 Remove the protective rubber guard from around the outer rim of the TBUS 1Axl housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 9 3 Takethe support brackets under the table and place them into the support
13. in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs Maximum 5A per power outlet Maximum 5A per power outlet Maximum 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A per power outlet 100 240V AC 50 60Hz 5A Maximum 5A per power outlet 220V AC 50 60Hz 5A Maximum 5A per power outlet 220V AC 50 60Hz 5A Maximum 5A per power outlet Dual Power Kit Assemblies 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet USA 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet 220V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet 220V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Australia Israel South Africa Universal Germany and EU France Israel South Africa FUSE RATING OPERATING TEMPERATURE RANGE OPERATING HUMIDITY RANGE 10 to 90 RHL non condensing STORAGE TEMPERATURE RANGE 20 to 70Deg C STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS 22 1cm x 18 2cm x 13cm 8 17 x 5 88 x 5 13 W D H WEIGHT TBUS 1A 1 5kg 3 31bs approx Table clamps 0 26kg 0 57Ibs Metal template 0 125kg 0 28Ibs Power cord six self locking ties metal template T 6 3A 250V 5 to 45 Deg Centigrade ACCESSORIES OPTIONS Inner frames passive wall plates and interfaces power socket kits
14. inside a Table Figure 2 TBUS 1Axl Enclosure Top View Figure 3 TBUS 1Axl Inner Frame P N 80 000299 Figure 4 Installing a Kramer TOOL Figure 5 Installing the T TBLANK TOOL Blank Figure 6 T RC8IR P N 80 000599 Figure 7 RC 8IR Faceplate holesTable Connection Bus Figure 8 Cut out Dimensions Figure 9 Inserting TBUS 1Axl into the Prepared Opening Figure 10 Cable Pass through Insert P N 80 000399 Figure 11 TBUS 1Axl Boardroom Installation OS O O R OO NNN Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Thank you for purchasing the Kramer TBUS 1Axl enclosure which is ideal for boardrooms conference and training rooms Note that the
15. into the appropriate frame P N 80 000399 or P N 80 000499 instead of two power sockets Inner Frame Attachment hole Faceplate Attachment hole IR IN Opening Faceplate Attachment hole Inner Frame Attachment hole Figure 6 T RC8IR P N 80 000599 Remove the RC 8IR Faceplate 1 Before installing the T RC8IR unscrew the two faceplate attachment screws and remove the RC 8IR faceplate Faceplate Attachment holes KRAMER Figure 7 RC 8IR Faceplate holesTable Connection Bus TBUS 1AxtI Installing the TBUS 1Axi EEE 2 Place the T RC8IR over the RC 8IR enclosure so that both face plate holes are aligned with the face plate holes on the RC 8IR enclosure and the IR IN receiver fits into the IR IN opening 3 Insert the faceplate screws through the T RC8IR and RC 8IR enclosure faceplate holes and tighten Installation Instructions To install the T RC8IR 1 Insert the T RC8IR assembly through the dual power socket opening from beneath 2 Use the two power socket screws to tighten the T RC8IR assembly in place 5 1 6 Installing the SI 1VGA RC 3TB To install the SI 1VGA RC 3TB module place it under the designated opening in the T1AF 14L P N 80 000699 and then screw and tighten it in place using two screws supplied with the inner frame 5 2 Installing the Inner Frame To install the inner frame 1 Place the inner frame inside the TBUS 1Axl enclosure 2 Set the required height using your fin
16. nline product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction TBUS 1Axl For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect the unit from the power supply before opening and servicing
17. nserts 4 blank inserts T1AF 44 P N 80 000499 2 openings for 4 power sockets 2 cable pass through inserts 2 blank inserts T1AF 14L P N 80 000699 1 opening for 1 power socket 1 opening for Kramer SI 1VGA RC 3TB 2 cable pass through inserts 2 blank inserts T1AF 1T3 P N 80 005199 1 opening for 1 power socket 2 openings for 3 Kramer TOOLS T1AF 14T P N 80 005299 1 opening for 1 power socket 1 opening for 1 Kramer TOOL 2 cable pass through inserts 2 blank inserts Custom made inner frames can be designed if required Contact Kramer Electronics for more details 4 2 TBUS 1Axl Accessories Accessories Description Inserts You can install any wall plate devices as well as any of the single or dual inserts see our Web site for details T RC8IR P N 80 000599 1 special panel to fit the Kramer RC 8IR Control Panel into the appropriate frame P N 80 000399 or P N 80 000499 instead of two power sockets T 2INSERT P N 80 00006699 The T 2INSERT kit can be installed inside a single power socket opening and includes 1 single cable pass through insert 1 dual cable pass through insert T TBLANK P N 80 005099 This TOOL blank covers a TOOL opening for the T1AF 1T3 P N 80 005199 and T1AF 14T P N 80 005299 inner frames TBUS 1Axl Your TBUS 1Axl Enclosure 4 3 Power Socket Options A choice of one or more power sockets per inner frame is available in several versions
18. ot become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty 1 Elect to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty I
19. rotective rubber guard protects the outer rim during shipping Remove it before installing the unit Inserted into the table cut out 4 TOOL Height Adjustment Used for installing Kramer TOOLS Screw Holes Tie Holes Insert the self locking tie through the holes to fix the pass through cables to the inside walls of the unit 6 Bracket Slits For attaching the two mounting brackets on opposite sides 7 Rubber Protectors Protect the table surface when mounting the unit and ensure soft tightening to the table underside one for each clamp Locking Butterfly Tighten to lock the mounting butterfly screw one for each Screws clamp Mounting Butterfly Tighten to secure the unit to the table surface one for each gt Screws clamp 10 Mounting Brackets 2 Place in the bracket slits after inserting the enclosure into the clamp Table Clamping Set table for securing the unit to the table surface one for each 11 Inner Frame Height For adjusting the height of the mounted inner frame Adjustment Screw Holes 4 1 TBUS 1Axl Optional Inner Frames The following inner frames can be installed in the TBUS 1Axl enclosure Inner Frames for TBUS 1A TBUS 1Axl Your TBUS 1Axl Enclosure Specifications define what you can include in this inner frame T1AF 16 P N 80 000299 1 opening for 1 power socket 2 cable pass through inserts 4 blank inserts T1AF 26 P N 80 000399 1 opening for 2 power sockets 2 cable pass through i
20. tion cm Split Grommets a apart slightly to insert cables Z Split Brackets Support the split grommet for the pass through cables 3 Blank Plates Four blank covers that can be replaced with wall plates as required Power Socket Opening Suitable for a single power socket or the T 2INSERT Adjustable Height Screw For adjusting the height of the inner frame Holes Mounting the Power Socket Assemblies To mount the power socket place the power socket under the frame in its appropriate place and tighten with the two screws supplied Power socket kits come with assembly instructions Mounting a Kramer TOOL To mount a TOOL for example to the T1AF 14T as shown in Figure 4 1 Screw the spacers to their designated places one on each side 2 Insert the TOOL from beneath through the TOOL opening 3 Screw the screws one on each side through the frame holes and spacers Sessa ssS SVSSVsVsss oeoeeeooe Step 2 Figure 4 Installing a Kramer TOOL Installing the TOOL Blank To install the T TBLANK as shown in Figure 5 1 Insert the T TBLANK from beneath through the TOOL opening 2 Screwthe screws one on each side through the frame a see THSSSSE S a Step 1 Figure 5 Installing the T TBLANK TOOL Blank TBUS 1Axl Installing the TBUS 1Axl 5 1 5 Mounting the Special Panel for RC 8IR The Kramer T RC8IR for the TBUS 1Axl Table Connection bus is used to fit the Kramer RC 8IR Control Panel
21. version 6ft North America C ACY US 91 000399 220V Y version 6ft Europe C ACY EU 91 000499 240V Y version 6ft UK C ACY UK 91 000599 5 5 1 5 1 1 Installing the TBUS 1Axl To install the TBUS 1Axl perform the following steps 1 Assemble the inner frame see Section 5 1 2 Install the inner frame see Section 5 2 3 Cutan opening in the table see Section 5 3 4 Insert the unit through the opening and secure to the table see Section 5 4 5 Connect the cables see Section 5 5 6 Insert the pass through cables see Section 5 6 7 Adjust the height of the inner frame see Section 5 7 Assembling the Inner Frame The modules mounted on the inner frame can include single inserts and or dual inserts as well as power sockets and various Kramer devices This section describes how to assemble these modules Each module kit comes with detailed assembly instructions Mounting the Inserts You can rearrange or remove any of the plates mounted on the inner frame and replace them with Kramer passive wall plates or connector modules for interfacing A V type signals To mount a Kramer insert or connector module 1 Unscrew the two screws that fasten the blank plate to the inner frame and remove the blank plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 1Axl Inner Frame P N 80 000299 Feature Func

Download Pdf Manuals

image

Related Search

Related Contents

Tubes CE - Accueil GREEN VIA  1PH813/1PH816  gs6 features - AV-iQ  Obstacle detection using V-disparity: Integration to the CRAB rover    Connecting M1™ to your Scope: You Have Choices  Riyadh College of Technology  Turbidímetro de Laboratorio Código: 45  TELÉFONO ALAMBRICO  00 - A Voz de Portugal  

Copyright © All rights reserved.