Home
SD3 DIAGNOSTICS SYSTEM
Contents
1. rr e ee o nU eig e UR EU ERR EHI TO IRSE HUE I E ode 28 2 10 Check Versi n Sicilia 37 2 11 SerialDiagriostics Meng iii ii LIMA A e e ERE s lito 38 2 12 Resolving SD3 Tester related problemS i 44 3 SD3 RRE le e D e dE EE 45 3 1 SD3 Diagnostics Software Operation enemies 46 St Main Menia oa eee eR e dede idee dn e e E tee e mee ec tes de te eed 46 3 1 2 Error MENU Rolih edin A ic 47 3 1 3 Paramotor Ml o ideo arr eed rec tiven z cel ia de 52 3 1 4 Diagnostics MNU rail ed mpl al e Gl Re e Dee 55 3 1 5 Acquisition 2000570000 56 3 1 6 Information ici A A e redi aae dee 59 4 BASIC SD3NET PG Software iii Rte iti cri 60 4 1 Introduction ini Rein EIE ede e UIS oe EM ne LLLA eee li 61 4 2 Update MENU coin GRA ai 62 4 2 1 Update ECU Software ocn uere be RO ERI Rr rti a 63 4 2 2 PC Dee E CN 64 64 4 3 PC Communication Menu aaa RA 65 4 3 1 Running the software on the PC nne nene nennen nnne nennen 66 4 3 2 SDS Tester Settiligs i sh gore cade eo ertet he dee Soh deal ie eats sate 69 4 4 Tester Data Men cinisello nihil alia 70 4 4 1 Print ciim 70 4 4 2 Acquisition Menu ct n reet e as 72 4 4 3 Print file and acquisition file management sse nnne 83 4 5 MaintehanceMenu der dani NA Ear Pi cete R y Edel 83 4 5 1 Set Communications parameters i 84 4 52 Workshop data eue ee UE Od EH D or RR RR E NT Re HEN
2. SD3 wireless board SD3 Manual 095970324 SD3 Quick Reference Installation CD ROM 095970326 8 metal point rods for Multimeter PC USB Wireless board For further information about the cabling wires please refer to chapter 7 Page 7 SD3 Diagnostics System User Manual 1 3 SD3 diagnostics system presentation The SD3 Diagnostics System is an electronic device for the diagnostics of electronic control units ECU installed in modern vehicles The SD3 diagnostics system is a palmtop device with a backlit color LCD display and a membrane keypad with twenty keys it is also equipped with e three standard RS232C serial lines e six standard ISO9141 CARB KEYWORD 2000 serial lines two standard CAN serial lines e multimeter in volts up to 200 V d c and Ohm up to 1 Mohm It can be interfaced to a PC containing the software required to update the ECU diagnostics software through one of the following lines e standard RS232C serial line USB serial line e Ethernet 10 100Mbit network e Ethernet Wireless 802 11b network For better efficiency and faster data transfer between the PC and the SD3 unit we suggest you use the USB line or an Ethernet Wireless network for communications Warning the SD3 Tester keypad can be used as remote control for the PC software for all communications lines except the serial lines SD2 Emulator The SD3 diagnostics system can be used with SD2 Diagnostics software in the emulator mode
3. Esc if this does not take place the Tester will in any case interrupt the command after a set time In both cases the Tester returns to the screen shown in fig 3 1 4 1 3 1 5 Acquisition Menu From the main diagnostics sw menu select ACQUISITION MENU to enter the menu where you can acquire data parameters and errors constantly requested of the ECU In particular a submenu is displayed offering the possible options ACQUISITION WITH DISPLAY ACQUISITION WITHOUT DISPLAY ACQUISITION IN TEXTUAL MODE see figure 3 1 5 1 Select one of the above menus and a screen appears The left side of this screen presents a list of all parameters implemented in the ECU and the right side shows a list of the errors Use the arrows to scroll through the data contained in the selected list press Tab to move the item selected to the other list or press confirm When a parameter error is pressed pressing the enter key selects or deselects if it was already selected the highlighted data On the other hand while if you press confirm you move on to the next menu typical of each acquisition mode A counter at the foot of the page indicates the individual report number element totals selected number element totals selectable even if the latter depends on the selected data acquisition mode Two smaller initially empty lists echo the data you have selected reporting in particular on the right the selected parameters and on the left the errors selecte
4. SD3 Diagnostics System User Manual 1 1 Minimum system requirements The PC where the basic SD3NET software and Diagnostics Software are to be installed should have the following minimum system requirements Hardware Pentium processor 2800 MHz 256 Mb RAM Free space on Hard Disk 850 Mb SVGA 16 bit color video card 1024x768 small font Keyboard mouse and color monitor One free communication line of the following types o One RS232C serial port o One USB port o Ethernet 10 100 network card o Wireless connection CDROM player Software Microsoft Windows XP Home or Professional suggested Service pack 1 or Windows 98 SE ME Service Pack 1 or Microsoft Windows 2000 Service pack 4 Internet Explorer amp 6 0 Service pack 1 1 2 Suitcase contents The SD3 Diagnostic System is supplied with a suitcase containing SD3 Tester Serial cable for SD3 SD2 connection to PC SD3 CBL01 095970327 Multimeter cable SD3 CBLO2 095970328 Power supply feeder SD3 CBLO5 095970331 EOBD SD3 diagnosis cable SD3 CBL06 095970332 Diagnosis cable with SD2 bridle SD3 CBLO7 095970333 Connection cable for feeding among SD2 and SD3 bridle SD3 CBL08 095970334 Cigar lighter socket feeder SD3 CBL09 095970335 ISO 1 extension SD3 CBL10 095970336 ISO 2 extension SD3 CBL 11 095970337 SD2 B CAN adapter SD3 CBL 12 USB cable 095970330 10 100 Mbps Ethernet cross over cable 095970329
5. The latter must be transferred to the SD3 tester through the basic SD3NET software and using the special SD2 Porting CD Never use the old SD2 CD If you wish to run diagnostics in STANDALONE mode follow the old SD2 instructions If instead you wish to run diagnostics using the SD2 software on the PC you must first press the START SD2 EMULATOR COMMUNICATIONS button on the SD3 tester Be careful because in this mode the only communications line possible between the PC and the SD3 is the RS232C serial line Multimeter The SD3 Diagnostics System has an integrated multimeter that can take measurements in Volts up to 200 V dc and Ohms up to 1 Mohm This function can be selected from the SD3 Tester main menu Scantool OBD The SD3 Diagnostics System has an integrated Standard Scantool OBD software This system makes it possible to automatically check for systems able to support the service engine shift Once the control unit has been identified by the software you can check some parameters errors supplied by the system itself This function can be selected from the SD3 Tester main menu Page 8 SD3 Diagnostics System User Manual 1 4 Power supply voltage The SD3 requires a voltage between 8 and 16 V DC which is supplied either by the battery of the vehicle being tested or by the power supply provided with the product 1 5 Installation instructions for the SD3 The SD3 does not require any installation it only needs
6. 01 service Page 28 SD3 Diagnostics System User Manual For all menus except the errors screen pressing enter at this level calls up a screen with a list of the ECUs that have been initialized This makes it possible to filter the system responses that is to display the parameters for that given ECU BD Page 29 SD3 Diagnostics System User Manual EOBD EOBD Fig 2 9 2 Page 30 SD3 Diagnostics System User Manual SERVICE HI PARAMETERS Service 01 Parameters In this menu all dynamic parameters requested continuously supported by the previously selected ECU and only these are displayed To move through the windows use the SD3 tester keys following the rules indicated above in the paragraph on serial diagnostics See fig 2 9 4 Page 31 SD3 Diagnostics System User Manual EOBD 503 W SD3NET i EOBD EOBD EOBD INITIALIZED ECU PAGE 1 3 rpm VEHICLE SPEED 0Dh SPARK ADVANCE CYLINDER 1 0Eh Km h AIR TEMPERATURE 0Fh INTAKE AIR GROUND 10h S o OTTLE POSITION 11h SELF ADAPTIVE MIXTURE RATIO BANK 2 09h FAST CORRECTION OF MIXTURE RATIO KO2 BANK 2 08h SELF ADAPTIVE MIXTURE RATIO BANK 1 07h FAST CORRECTION OF MIXTURE RATIO KO2 BANK 1 06h WATER TEMPERATURE 05h v UNE rs Gem Gm rr mr e GE 5 EE Fig 2 9 4 Page 32 SD3 Diagnostics System User Manual Service 02 FFD In this menu the Free
7. 30 BOSCH SW N BOSCH SW VER 3000 HOMOLOG N CUSTOM BYTE 2000000000 SHOP CODE PRODUCTION DATE 31140205 Fig 3 1 6 1 Press Esc to return to the diagnostics software main menu in fig 3 1 1 1 use the up down arrows to scroll through the information list Page 59
8. CD Double click on SETUP EXE The installation wizard will now run A window will be displayed for the selection of the language to use during the program installing The installation wizard displays a start window Click on NEXT to continue You will be prompted to install Microsoft Framework NET 1 1 if it is not present Always confirm and proceed with installation You are asked to name the directory in which the program will be installed we recommend leaving the default setting Click on NEXT to continue You are asked to name the directory DATA in which the program will be installed we recommend leaving the default setting Click on NEXT to continue The last window gives a summary of the previous selections Press NEXT and the system starts copying the program to your PC When the installation has terminated you will be asked to reboot your PC This is essential for the program to operate correctly When the PC has been rebooted the SD3NET icon will appear on the desktop 1 9 USB Driver 1 Insert the USB Adapter 2 Respond to the prompts as they appear lf you are prompted for the drivers enter d where d is the location of the CD ROM drive where the nstallation CD is inserted 3 During the installation process you may receive prompts for the Windows installation CD Insert the CD for your Windows operating system and indicate the correct path Your computer goes through a brief installation process during which it displa
9. CORRECTION WITH BATTERY VOLTAGE AIR FLOW METER KNOCK SIGNAL MOT PLAUSIB ACCELERATOR PEDAL POTENTIOMETER 1 40 AIR FLOW METER LOW INPUT Fig 3 1 5 2 Acquisition with display The screen displays the trend in time for the parameters selected in different graphs but which all share the abscissa time Each graph displays the current value unit of measure if present space on the grid both in the direction of the abscissa horizontal step and ordinate vertical step graph limits both for time and the value taken on by the parameter Throughout the period the value is displayed a file is created in the non volatile memory that can be handled with a special PC sw menu Press Esc to exit the graph menu and interrupt saving the data to file Acquisition without display Even though dialogue with the ECU is immediately active to start acquisition to file you must select the special button START ACQUISITION and press enter The counters in the yellow box will then begin counting the value sampling moment and the progressive number of samples acquired Press END ACQUISITION to interrupt data acquisition to file and reset the counters You can start the procedure again by pressing START ACQUISITION once more These keys can be selected either by using the arrow or Tab keys Press Esc to exit this menu any acquisition in progress will be interrupted and return to the previous screen Acquisition in textual mode For each param
10. HEP SiS 85 Mee E OT 86 4 5 4 Vehicle Database 5 EE IRI n ai n e bnt a go Re REL Hi e feto datos 87 4 5 5 Select Language EE 88 4 5 6 Transfer Operating System 89 4 6 Informationi Men era ceps tre laki ei Rr ge ia nia a EE bis 90 b Problem solving x e tee o ee e Lia e p E EE dep ae te tet ere et 91 5 1 The screen remains yellow when the tester is switched om 92 5 2 The communication through serial line does not work 92 5 3 The communication by network cable does not work 92 Page 2 SD3 Diagnostics System User Manual 5 3 1 Tester joint to a local Mii Dee epe ret b ene ks 92 5 3 2 Tester directly joint to the PG ci ENA tee edt did dre EH db 92 5 3 9 General probl amp ms iden cd ee te ei ZNE e nd ie edet 92 5 4 The wireless communication does not work properly eene 93 5 4 1 Tester connected to an access point 93 5 4 2 Tester connected in point point mode A 93 5 4 3 ai IN eve ode DADA 93 5 5 The USB communication does not work properlY eene 93 5 6 When the tester is switched on it displays a screen WAIT SOFTWARE DOWNLOAD 94 5 7 When the tester is switched on it blocks the yellow screen to restore it does not appear 94 5 8 When the tester is switched
11. NAB AIRBAG TRW DIAGNOSI DOPPIA CONTROLLO MOTORE SINISTRO CONTROLLO MOTORE DESTRO BO VOLANTE MOMO VANO BAULE MAGNETI MARELLI TYRE PRESSURE BERU SISTEMA PARCHEGGIO VALEO QUADRO STRUMENTI MAGNETI M PORTA PASSEGGERO MAGNETI M PORTA GUIDATORE MAGNETI MA NODO IMPERIALE DIGITEK NODO FRENANTE BOSCH CONTROLLO SOSPENSIONI SACH CAMBIO ROBOTIZZATO MAGNETI CLIMATIZZATORE DELPHI BODY COMPUTER MAGNETI MARE ASSETTO PASSEGGERO BITRON ASSETTO GUIDA BITRON PORTA GUIDATORE MAGNETI MA RADIO NAVIGATORE BLAUPUNKT NODO IMPERIALE DIGITEK NODO FRENANTE BOSCH CONTROLLO SOSPENSIONI SACH CAMBIO ROBOTIZZATO MAGNETI NCM CONTROLLO MOTORE BOSCH MOT 00 CD CO CO CD CO CD CD CO CD CD CO CO CO CO CD CO CO CD CD CO CD co CO CO CO oda x Fig 2 10 1 Page 37 SD3 Diagnostics System User Manual 2 11 Serial Diagnostics Menu The Serial Diagnostics Menu lets you run the ECU diagnostics programs loaded into either the SD3 or SD2 from the PC Select DIAGNOSTICS and press Enter to display the list of diagnostics programs pre loaded into the Tester if no programs have been pre loaded the device will display fig 2 11 1 SYSTEM MESSAGE Fig 2 11 1 Press Enter or Esc to return to the Main Menu If the device contains diagnostics programs you will be guided through selection of the diagnostics you wish to run To select a diagnostics program you are almost always required to specify the Manufacturer of the vehicle in which the ECU is installed t
12. address to be inserted depends on your network configuration but it must never be the same as the PC address Normally this information is provided by the network administrator The last choice for the Wireless network is the name of the access Point For this configuration see the access Point manual The Wireless address must be different from the Ethernet line IP address they must be on different subnetworks e g LAN 192 28 2 50 Wireless 172 28 2 50 Examples of settings See Ethernet 10 100 Mbit line selection ACCESS POINT POINT POINT SELECTION The Wireless Net can work either in Access POINT mode that means the SD3 Tester is connected via radio to an Access Point device that joins it to a wider Lan Net that is formed by several devices PC or in POINT POINT mode That means the SD3 Tester is connected via radio directly to one PC and not to a wider PC Net ADVANCED It allows to configure the data protection WEP on the Wireless transmission 40 bit or 104 bit protection By selecting one of the two entries it will be possible to choose a key 5 characters for the 40 bit protection and 14 characters for the 104bit protection This key must be set within the operating system of the wireless PC IMPORTANT NOTE P m L or M characters must not be present in the key SD3 Diagnostics System User Manual 353 v V spaner B mposrazrone AMBIENTE CONFIGURAZIONE IMPOSTAZIONE SICUREZZA W
13. deleting errors has its ovvn particular menu since it implements a precise service service 4 of the OBD protocol Here too the ECU is not preselected Rather error deletion always refers to ALL currently active systems The OBD protocol requires that deletion be performed only when the engine is off a dialog box message reminds you of this fact The outcome of the operation is indicated after the command is issued See fig 2 9 7 Page 34 SD3 Diagnostics System User Manual 503 v e SD3NET LI EOBD Soen EOBD EOBD V ERROR ENVIRONMENT INITIALIZED ECU DELETING ERRORS Fig 2 9 7 Service 09 Info In this menu some information regarding the specific ECU message counter VIN if supported are displayed as though they were dynamic parameters To move through the windows use the SD3 tester keys following the rules indicated above in the paragraph on serial diagnostics See fig 2 9 8 Page 35 SD3 Diagnostics System User Manual zoso C EOBD Fig 2 9 8 Page 36 SD3 Diagnostics System User Manual 2 10 Check Versions The CHECK VERSIONS menu lets you display the versions of the diagnostics software installed on the SD3 tester in the following format fig 2 10 1 MANUFACTURER Model system Version Date Release FERRARI F137 NBC Body Computer 090000 1 00 21112003 6 2 Press the button with the printed icon to print these data Press Esc to return to the Main Menu
14. periods The address to be inserted depends on your network configuration but it must never be the same as the PC address Normally this information is provided by the network administrator Examples of settings e PC not part of a corporate network Use an Ethernet 10 100 Mbit Crossover cable supplied with the SD3 tester PC SETTINGS IP Address 172 28 2 100 Subnetmask 255 255 255 0 SD3 SETTINGS IP Address 172 28 2 36 Subnetmask 255 255 255 0 Page 17 SD3 Diagnostics System User Manual Page 18 e PC within a corporate network Use an Ethernet 10 100 Mbit network card not supplied with the SD3 tester PC SETTINGS 1 Address depends on the network administrator Subnetmask depends on the network administrator SD3 SETTINGS IP Address have the network administrator provide a static IP address Subnetmask get this information from the network administrator For problems related to the net configuration refer to chapter 5 or contact the net installer Wireless Address This field lets you in put an IP Internet Protocol Address Together with the following field SUBNETMASK this address identifies the SD3 Tester within the TCP IP network using a Wireless network Remember that this field is only displayed and valid if the card has been inserted in the SD3 Tester Both the IP address and the subnetmask are 32 bit 4 digit numbers ranging from 0 to 255 separated by periods The
15. the parameters for the communications line between the PC and the SD3 Tester fig 2 4 2 SD3 Tester PC communications line On the left side of the screen you can select the SD3 Tester PC communications line The following choices are available USB line e Serial RS232 line e Ethernet 10 100 Mbit Wireless line Press one of the three buttons to select the desired communications line It will only become effective after you have pressed CONFIRM Remember the selection must also be made on the Basic SD3NET software of the PC that will be connected to the SD3 On the right side of the screen you can select all addresses configuring the use of the Ethernet IP LAN SUBNET MASK network fig 2 4 2 Page 16 SD3 Diagnostics System User Manual GER spaner gt AMBIENTE CONFIGURAZIONE SELEZIONA CANALE DI COMUNICAZIONE USB RS232 SUBNETMASK SELEZIONE RETE 255 255 IP STAZIONE PC GATEWAY LAN PORT LAN PC IDENTIFICATIVO WIRELESS SD3 HE 28 3 119 255 255 255 255 50000 E IP WIRELESS ACCESS POINT PUNTO PUNTO ACCESS POINT GATEWAY WIRELESS 5 255 0 119 2 CONFERMA LA Fig 2 4 2 LAN Address The first field lets you input the IP Internet Protocol address Together with the next field SUBNETMASK this address identifies the SD3 Tester within the TCP IP network Both the IP address and the subnetmask are 32 bit 4 digit numbers ranging from 0 to 255 separated by
16. to be configured with the diagnostics software to be used The downloaded software are stored in the non volatile memory of the SD3 unit The SD3 is equipped with a battery powered clock which can be set and checked on the PC through a special software menu 1 6 General Description The figures below provide a diagram of the upper part containing the power supply and diagnostics connectors front part of the SD3 unit containing the display keypad and ON light and the lower part containing a flap which provides access to the connectors used to hook up an American PS2 keyboard for the PC and two PCMCIA connectors used for any hardware expansions e g flash expansions Wireless card through external boxes The ten keys at the bottom of the screen are used to input data numbers letters into the diagnostics software The directional arrows and the TAB key feature function repetition if the key is held down continuously In all menus hold down Switch and Esc for 4 seconds to reset the SD3 Tester software This speeds up restarting the device if the software crashes the Tester does not respond to keypad commands The top holds the following see fig 1 6 1 The power button One 25 pin connector for power and serial diagnostics lines on the power button side One 9 pin connector male for hook up to the PC in the centre One 9 pin connector female for Multimeter inlet One Ethernet 10 100 Mbit connector One USB connec
17. 95 SD3 DIAGNOSTICS SYSTEM USER MANUAL SD3 Diagnostics System User Manual Contents PRECAUTIONS AND SAFETY MEASURES ii 4 Dataplatevand Warranty ia aa ob sat ute n audi ote 5 Warranty E E ede etre Pee es dad eee c dee ceder POR ee rs i Recette 5 1 General information 222 22 22 n EMANE ESEE EESEEESNEAS EENEN EENE EESEEES EEN En SEEE EEEn E EnEn 6 1 1 Minimum system reguirements ee 7 1 2 Suitcase CONTENTS zi ono aset Ee EIE airis 7 1 3 SD3 diagnostics system presentation i 8 1 4 Power s pply voltage iaia elio D e e E RP LE 9 1 5 Installation instructions for the GI 9 1 6 General De scriptlom i oi bete oe GI e a e on e e EROR n dali 9 DESDE T 9 1 8 Installing the Basic SD3NET software on the PDC 11 9 USB Drivers UM 11 2 SD3 Operation tpe anale ott debes ad eed av aaa 12 2 1 Start SCEN E M 13 272 EIC 14 2 3 SD3 System HW SW Information Mem 15 2 4 SD3 Contiguratlor Menu eut I eerie or pe ei do opo b d ananas l detail 16 2 5 Start PC Communications Mem 21 2 6 Start SD2 Emulator Communications 6225 23 2 7 Tools Selection Men ioni etin dt e dtd eee doi Fr A tut eed dete dde eins 25 2 752 Data deleting eee ete cene Ba E Seite AA 27 2 8 Expansions Menlu 2 eee i il AE 28 2 9 OBD SCANTOOL SCREEN
18. ART PC COMMUNICATIONS menu enables dialogue with the PC software to update diagnostics programs and to download the acquisition files from the Tester to the PC Select START PC COMMUNICATIONS and press Enter to open the Menu shown in fig 2 5 1 The information that appears in the window depends on the communications mode selected Serial RS232 mode A LED goes on and blinks as long as the unit is in communication with the PC Ethernet Wireless mode As soon as the PC software Basic SD3NET software and or control unit diagnostics software activates a connection with the SD3 Tester the IP address of the user or users connected to the Tester is displayed in the window In addition a LED goes on and blinks as long as the unit is in communication with the PC except when files are being transferred As soon as the PC software is disconnected from the SD3 Tester it disappears from the screen USB mode A LED goes on and blinks as long as the unit is in communication with the PC Press Esc to return to the Main Menu Do not press Esc on the Tester while data is being exchanged with the PC as this would interrupt the communications in progress Page 21 SD3 Diagnostics System User Manual 503 W sD3NET O LINK TESTER 313 PC PRESS ESC TO EXIT PC lt gt SD3 LAN COMMUNICATION USER CONNECTED 172 28 3 115 SISTEMA DIAGNOSTICO SD3FERRARI MASERATI Fig 2 5 1 Page 22 SD3 Diagnostics System User Manual 2 6
19. IRELESS IMPOSTAZIONE SICUREZZA WIRELESS mme asma im 128 BIT abcdefghilmni CONFERMA SD3NET PC IP Address for Direct Printing In menus that permit data printouts errors parameters information it is possible to send this information directly to the PC printer using the SD3 tester under the following conditions e The communications line between the SD3 tester and the PC must be an Ethernet or Wireless line basic SD3NET software must be active on the SD3NET To identify the PC containing the SD3NET system you must select its IP address The IP address is a 32 bit 4 digit number between 0 and 255 separated by periods This information can be obtained either by asking the network administrator or by following the procedure below e From the PC press the START button at the bottom left e Select RUN For Windows XP 2000 NT type in CMD and click OK for Windows 98 ME type in command e Input IPCONFIG and press ENTER The IP address is the address following the words IP Address 172 28 3 3 for example GATEWAY LAN It is possible to select an IP address to perform the tcp ip packets gateway PORT LAN PC It is possible to select the gate relevant to the TCP IP address to the PC Warning This value 50000 must not be changed presently it will be used for future new versions of SD3NETPC Page 19 SD3 Diagnostics System User Manual Select the USB line Select the RS232 li
20. ND GEAR ENGAGEMENT 3RD GEAR ENGAGEMENT 4TH GEAR ENGAGEMENT 5TH GEAR ENGAGEMENT 6TH GEAR ENGAGEMENT REVERSE GEAR ENGAGEMENT NEUTRAL ENGAGEMENT Fig 3 1 4 1 If we select a particular diagnostics and press Enter we enter a guided procedure which uses user prompts and sends signals to the ECU to effect the desired implementations If for example we need to switch off the engine to run the command a screen similar to the one in fig 3 1 4 2 will be displayed The requested condition is displayed Engine Status Off the parameter is constantly checked by the Tester Engine rpm comparing the value requested and the value read The condition must be maintained for a few seconds before being deemed satisfactory and moving on to issuing the next command During this period pressing Esc displays the menu shown in fig 3 1 4 1 Page 55 SD3 Diagnostics System User Manual SD3 v Q sD3HET M 11139 ncn 139 nch MASERATI M139 HCH CONTROLLO MOTORE BOSCH MOTRONIC DIAGHOSIS MENU DYNAMIC PARAMETERS CHECK ENVIRONMENT INJECTOR 1 INITIALIZED ECU STATO MOTORE SPENTO ENGINE REVOL aaa Fig 3 1 4 2 When the condition has been satisfied the Tester will send the actuation command to the ECU in case of an incorrect response from the ECU an error window is displayed Test Failed otherwise a window is displayed with the name of the test underway fig 3 18 12 You can interrupt the command by pressing
21. Start SD2 Emulator Communications Menu Select START SD2 EMULATOR COMMUNICATIONS and press ENTER to open the screen shown in fig 2 6 2 that will upload the modules necessary to the SD2 emulator At the end of the upload it could last a while depending on how many SD1 SD2 ECU are installed the window 2 6 1 will be shown This menu enables dialogue with the diagnostics software on the PC developed for the SD2 the SD1 software transferred on the SD2 as well You can use the SD3 Tester as though it were an SD2 Tester Do not hook up to the vehicle using the EOBD wiring SD3 CBLO06 supplied for new vehicles rather use a harness like the 502 SD3 CBLO7 to be connected to the EOBD wiring that the shop already owns As for the SD2 tester in this operating mode it is possible use the SD3 keypad to control the SD2 PC software WARNING gt This menu uses a serial RS232 communications line USB or LAN WIRELESS lines cannot be used The various Basic SD3NET software packages will automatically set this serial line upon exiting the previously set communications line for normal operations is automatically restored gt Do not use basic SD2 software to update the SD3 tester gt The basic SDSNET PC software can update the SD2 diagnostics system software Warning on some systems to use the RS232 serial line can cause problems of connection Press Esc to return to the Main Menu Do not press Esc on the Tester while data is being exch
22. The Expansions Menu makes it possible to run non diagnostics programs for the ECUs downloaded from the PC for example oscilloscope Select EXPANSIONS and press Enter to display the list of programs preloaded into the Tester If no programs are loaded into the Tester Press Enter or Esc to return to the Tools Selection Menu 2 9 OBD SCANTOOL SCREEN From the main diagnostics sw menu select OBD SCANTOOL to enter the OBD On Board Diagnostic menu This software serves for diagnosis of vehicle systems that implement the Scantool protocol that is the diagnostics protocol controlling the vehicle s pollution emissions No selection is planned since the software communicates with all control units in the vehicle that support the protocol Press enter to immediately load the diagnostics software indicated by a red bar Once it has loaded a window prompts you to turn the key to ON and press confirm to initialize the system see figure 2 9 1 If there is no dialogue with the vehicle a message prompts you to check the connection between the tester and the control unit If the initialization process is completed successfully a list of the control units initialized appears typically engine and clutch The individual ECUs are identified through the protocol wake up address its only characterizing element see fig 2 9 2 Press enter to call up the main menu in fig 2 9 3 The diagnostics functions are characterized by a number ex
23. a red bar indicating the progress Page 41 SD3 Diagnostics System User Manual 503 v U sD3NET MODULE LOADING IN PROGRESS MASERATI M139 TUTTI NCR CAMBIO ROBOTIZZATO MAGNETI MARELLI ISO 1 LINE SD3 FERRARI MASERATI DIAGNOSTICS SYSTEM Fig 2 11 5 If an error screen appears during the diagnostics software selection phase the diagnostics software that caused the load run problems must be reinstalled through the PC software If the selected software was an SD2 emulator you will be prompted for the communications line prompted to input the special SD2 harness SD3 CBL07 and finally the software will be run presenting the same 502 graph For a description of software operation see the SD2 user s manual contained in the SD3Net CD in the 5 languages under the ManualSD2 directory Fig 2 11 6 Be aware of whether you are connected to an EOBD outlet SD3 CBLO6 In this case you must turn off the SD3 Tester connect the special SD2 harness SD3 CBL07 and then start the ECU selection process over again Once you have completed the activity with this SD2 emulation diagnostics program SD3 will be automatically reset Page 42 SD3 Diagnostics System User Manual SOSPENSIONI BILSTEIN F56 1501 IMPOSSIE I LE MODRLITA IL Ta I T H PREMERE UH TASTO Versione Software su Tester Fig 2 11 6 Page 43 SD3 Diagnostics System User Manual 2 12 Resolving SD3 Tester related problems After having
24. anged with the PC as this would interrupt the communications in progress 503 v sooner PREMERE ESC PER USCIRE COMUNICAZIONE TRAMITE SERIALE EFFETTUARE COLLEGAMENTO SERIALE TESTER PC STRUMENTI ESPANSIONI SISTEMA DIAGNOSI SD3 FERRARI MASERATI fig 2 6 1 Page 23 SD3 Diagnostics System User Manual Fig 2 6 2 Page 24 SD3 Diagnostics System User Manual 2 7 Tools Selection Menu The TOOLS SELECTION lets you use the tools available on the SD3 such as the Multimeter Select TOOLS SELECTION and press Enter to display the menu shown in fig 2 7 1 To choose one of the options just highlight it with the up down arrows or tab key and press Enter Press Esc to return to the Main Menu SD3NET PRIVATI CANCELLAZIONE DATI AGGIORNAMENTO ABBONAMENTO ESCI Fig 2 7 1 2 7 1 Multimeter Menu The Multimeter menu permits use of a Voltmeter and Ohmmeter integrated with the Tester Select MULTIMETER and press Enter to display the Menu shown in fig 2 8 1 Page 25 SD3 Diagnostics System User Manual VOLTMETER OHMMETER VOLT 0 00 os 500000 00 1000000 00 Fig 2 8 1 The Voltmeter operates in the range 200V dc 4 auto range scales with a precision of 0 5 of the full scale The Ohmmeter operates in the range 0 1 MOhm 4 auto range scales with a precision of 0 5 of the full scale To use the Multimeter attach the SD3 tester cable to the 9 pin connect
25. aving highlighted a particular error press Enter to view any additional information regarding the problem An example is given in figure 3 1 2 3 Page 48 SD3 Diagnostics System User Manual MASERATI F133 NCR CAMBIO ROBOTIZZATO MAGNETI MARELLI BEYOND MAXIMUM THRESHOLD DIAGNOSIS COMPLETED ERROR PRESENT WARNING LAMP STATE ON COUNTER 64 SYSTEM CONDITIONS 100007 POT ENGAGEMENT 1023 POT SELECTION 0 CLUTCH REF 462 ENGINE REVOL 0 INPUT RPM 0 WHEEL TURNS 0 HYDRAULIC CIRCUIT PRESSURE 100bar SYSTEM TIME ON SV CORR FOR EVEN GEAR ENGAGEMENT Oma SV CORR FOR UNEVEN GEAR ENGAGEMENT Oma 1 2 3 SPEED SELECTION SV 0 CORR CLUTCH SV Fig 3 1 2 3 Use the arrow keys to scroll lists of information Esc returns to the Display Errors page fig 3 1 2 1 In the screen shown in fig 3 1 2 3 pressing the printer icon key writes on the Tester disk a file with the errors encountered and all associated information The screen which displays while the file is writing will look like the one shown in fig 3 1 2 4 These files can be transferred to the PC and printed out see par 4 4 The Tester stores them in non volatile memory and hence they will stay in memory even after the Tester is switched off Nevertheless to prevent wasting Tester disk space it is best to periodically transfer the files to the PC disk through the special SD3NET PC menu and delete them from the tester disk Page 49 SD3 Diagnostics System Use
26. ays the errors status No Error or the list of errors encountered If there are any errors in the ECU s memory the screen will be similar to the one shown in fig 3 1 2 1 The bar above the errors is yellow if the ECU is connected and diagnostics are running and is red if the link between the ECU and the Tester fails In the latter case a page similar to the one shown in fig 3 1 2 2 is displayed prompting you to check the connection and confirm your desire to attempt initialization again Press Enter to try again or Esc to return to the screen shown in fig 3 1 1 1 In the case shown in fig 3 1 2 1 some errors are displayed on a single page PAGE 1 1 on the yellow bar If more than 11 errors are present there will be more than one page To scroll through the various pages use the up down arrows or flip through the pages using key 8 PGUP or 9 PGDN SD3 v e SD3NET in u139 NER ERATI F139 NCR CAMBIO ROBOTI MAGHETI MARELLI Fig 3 1 2 1 Page 47 SD3 Diagnostics System User Manual 503 v e SD3NET m M133 RCR GHETI MARELLI ECU NOT INITIALISED PAGE 1 1 P1730 PUMP RELAY DRIVER P1757 SV FOR EVEN GEAR E P1758 CLUT v TIMEOUT ERROR CHECK THE CONNECTIONS BETWEEN THE TESTER AND THE ECU TO INITIALISE THE ECU TURN THE KEY TO MARCIA AND PRESS ENTER PRESS ESC TO EXIT Fig 3 1 2 2 Press Esc to return to the screen shown in fig 3 1 1 1 Press tab to highlight the various errors one by one After h
27. d for acquisition see fig 3 1 5 2 Selections not permitted if for example the maximum number of elements has been exceeded is indicated in a special dialog box Page 56 SD3 Diagnostics System User Manual Once you have selected all the elements you wish to acquire press enter with the confirm button selected and you can move on to the next screen MASERATI F133 NCR CAMBIO ROBOTIZZA MAGNETI MARELLI FLEET Fig 3 1 5 1 Page 57 SD3 Diagnostics System User Manual 3 MASERATI 139 HCM CONTROLLO CH MOTRONIC ENGINE REVOL 30 FRONT RH LAMBDA SENSOR CIRCUIT ENGINE TEMPERATURE 31 FRONT RH LAMBDA SENSOR LOW CIRCUIT INTAKE AIR TEMPERATURE 32 FRONT RIGHT OXYGEN SENSOR HIGH CIRCUIT INTAKE AIR 33 REAR RH LAMBDA SENSOR CIRCUIT IGNITION ANGLE REAR RH LAMBDA SENSOR LOW CIRCUIT REAR RH LAMBDA SENSOR HIGH CIRCUIT ENGINE FILLING RH B AND LH B FRONT LAMBDA SENSORS THROTTLE ANGLE RH B AND LH B REAR LAMBDA SENSORS AIR FLOW 38 FRONT LH LAMBDA SENSOR CIRCUIT BATTERY VOLTAGE 39 FRONT LH LAMBDA SENSOR LOW CIRCUIT VEHICLE SPEED 3A FRONT LEFT OXYGEN SENSOR HIGH CIRCUIT FRONT LAMBDA SENSOR VOLTAGE CYL 1 2 3 10 11 12 REAR LH LAMBDA SENSOR CIRCUIT REAR LAMBDA SENSOR VOLTAGE CYL 1 2 3 10 11 12 REAR LH LAMBDA SENSOR LOW CIRCUIT NOMINAL RPM IN IDLE CONDITION S3D REAR LH LAMBDA SENSOR HIGH CIRCUIT CANISTER PURGE VALVE OPENING S3E SENSOR FOR ENVIRONMENT AIR TEMPERATURE INJECTION TIME
28. eter this menu reports the current value read by the ECU and if it is an analog value it also reports the minimum and maximum value for each constantly updated datum For acquisition with display the data save begins automatically when you enter the menu and terminates when you press Esc At the foot of the page the number of samples acquired to that point is displayed along with the sampling instant expressed in milliseconds which is updated constantly Page 58 SD3 Diagnostics System User Manual 3 1 6 Information From the diagnostics software main menu in fig 3 1 6 1 select the ECU Information menu and press Enter to display information on the hardware and software versions of the ECU The information displayed depends on the particular ECU involved in the diagnostics a possible implementation is shown in figure 3 1 6 1 The Diagnostics SW Version refers to the program running on the Tester all the other information refers to the ECU itself In the screen shown in fig 3 1 6 1 pressing the print icon writes on the Tester disk a file containing the information displayed These files can be transferred to the PC and printed out see par 4 4 The Tester stores them in non volatile memory and hence they will stay in memory even after the Tester is switched off emmer EZ MASERATI M139 HCH CONTROLLO MOTORE BOSCH MOTRONIC DIAGNOSIS SW VER 10 00 04 DTD 07 01 04 MASERATI HW N 181228 00 BOSCH HW N 1026120695 BOSCH HW VER
29. fig 3 1 3 2 The text is on a yellow background if the ECU is connected and diagnostics are running and on a red background if the link between the ECU and the Tester fails In the latter case a page similar to the one shown in fig 3 1 2 2 is displayed prompting you to check the connection and confirm your desire to attempt initialization again Press Enter to try again or Esc to return to the screen shown in fig 3 1 3 1 Page 52 SD3 Diagnostics System User Manual 503 v e SD3NET im M133 RCR AGHETI MARELLI SELECTION POTENTIOMETER TRAVEL 02h CLUTCH PRESSURE PLATE TRAVEL 03h 000 98 CLUTCH PRESSURE PLATE REFERENCE 04h Ha HYDRAULIC CIRCUIT PRESSURE 05h nu WATER TEMPERATURE 06h mn BATTERY VOLTAGE 07h w O LEVER STATUS 08h mmm ENGINE RPM 09h Em rpm GEARBOX PRIMARY SHAFT RPM 10h Sa rpm CAR SPEED 11h nu Km h REOUESTED GEAR 12h m Fig 3 1 3 2 In the case shown in fig 3 1 3 2 there are 11 parameters displayed on a single page PAGE 1 1 on the yellow bar If there were more than 12 parameters there would be more than one page To scroll through these pages use the up down arrows or flip through the pages using the number keys 8 PGUP and 9 PGDN There are generally two types of parameters e Analogue parameters such as engine rpm the value of the parameter and its dimensions are displayed e Digital parameters such as Vehicle Control Status the decoded value is shown in its ac
30. he vehicle and ECU model and finally the system to be tested If more than one serial line is available for the diagnostics routine you will be prompted to specify which one to use This is not normally the case because the SD3 automatically selects the default line set during vehicle design Therefore the last passage is hidden to the user on the contrary if you have selected diagnostics of the previous SD2 system the procedure requires you to set the diagnostics line as well The procedure thus starts with selection of the Manufacturer from among the diagnostics programs loaded into Tester The display can appear as shown in fig 2 11 2 Page 38 SD3 Diagnostics System User Manual MANUFACTURER USER SELECTION Fig 2 12 2 Select the Manufacturer with the arrow keys and press Enter to confirm You can flip through the pages by pressing key 8 previous page and 9 next page or if the unit is connected to an outside keypad by pressing PGUP and PGDN Press Esc to return to the Main menu If for instance we select FERRARI and press Enter a page similar to the one shown in fig 2 12 3 will be displayed Page 39 SD3 Diagnostics System User Manual CAR Fi37 USER SELECTION Fig 2 12 3 For this window the above rules apply At the bottom of the window appears a field which displays the previous selection FERRARI If we select F137 and press Enter a page similar to the one shown in fig 2 11 4 wil
31. l be displayed Page 40 SD3 Diagnostics System User Manual ECU SYSTEM NAB AIRBAG TRW CSG SERVOGUIDA SAGEM PROXY NCM DIAGNOSI DOPPIA NCM CONTROLLO MOTORE SINISTRO BOSCH MOTRONIC NCM CONTROLLO MOTORE DESTRO BOSCH MOTRONIC NYO VOLANTE MOMO NVB VANO BAULE MAGNETI MARELLI NTP TYRE PRESSURE BERU NSP SISTEMA PARCHEGGIO VALEO NOS QUADRO STRUMENTI MAGNETI MARELLI NPP PORTA PASSEGGERO MAGNETI MARELLI NPG PORTA GUIDATORE MAGNETI MARELLI NIM NODO IMPERIALE DIGITEK NFR NODO FRENANTE BOSCH NCS CONTROLLO SOSPENSIONI SACHS SKYHOOK NCR CAMBIO ROBOTIZZATO MAGNETI MARELLI USER SELECTION Fig 2 11 4 For this window the rules given above for selecting the Manufacturer apply At the bottom of the window appears a field which displays the previous selection FERRARI F137 If we select NBC Body computer MARELLI and press Enter we enter the serial line selection screen or the diagnostics software Let us assume that we do not need to select the serial line this is rarely necessary and in any case follows the same procedure outlined in the points already covered After having made all the required selections the tester will automatically request the vehicle serial code to the ECU Then we enter the diagnostics software Note the vehicle serial code request will not be repeated until the user will not quit the ECU SYSTEM selection window Loading the software required for diagnostics of the selected program is accompanied by
32. more than the specified voltage Use only the battery power cord or power supply feeder provided with the product Do not operate the device if it is malfunctioning If the device is damaged have it serviced by a qualified service technician Page 4 SD3 Diagnostics System User Manual Dataplate and warranty The dataplate is located beneath the supporting platform and bears the manufacturer s trademark and the model and serial number for the device Write down the serial number in the space below and quote it when asking for information about the device SD3 Serial nl Warranty FERRARI MASERATI warranties the SD3 diagnostics system for 24 twenty four months from the date of purchase indicated on the delivery note supplied by FERRARI MASERATI During the warranty period FERRARI MASERATI will replace free of charge any parts with manufacturing or material defects acknowledged by FERRARI MASERATI The warranty does not cover accidental damage or damage incurred during shipping or due to incorrect use of the device Service under warranty does not renew or prolong the period of validity of the warranty For any service requirements contact Servizio Assistenza Tecnica FERRARI S p A v Abetone Inf re 41053 Maranello MO ITALY Servizio Assistenza Tecnica MASERATI S p A 322 v Ciro Menotti 41100 Modena ITALY Page 5 SD3 Diagnostics System User Manual 1 General information 2530 LDragnos S D Page 6
33. ne Once you have selected the line just connect the cable If the line selected is RS232 RS232 PC cable see chapter 7 The communication can be extremely slow and one could not be able to use some systems If the line selected is USB USB cable see chapter 7 If the connection is via LAN recommended cross over cable see chapter 7 No cable needed in case of wireless connection Press Language to modify the language used in the SD3NET screens fig 2 4 1 Press the button just below the language flag to confirm your choice and automatically exit the window To void without saving press Esc or press the cancel key The language selected on the SD3 only affects the messages for the routine software which selects and runs the diagnostics programs basic SD3NET software The diagnostics software language on the other hand is selected in the PC initialization software to avoid any possible inconsistencies make certain that the PC and SD3 are both using the same language Press Esc to return to the previous menu WARNING TO SAVE TESTER DISK SPACE THE DIAGNOSTICS SOFTWARE IS ONLY DOWNLOADED IN ONE LANGUAGE DEPENDING ON THE BASIC SD3NET SOFTWARE SETTINGS ON THE PC TO SET THIS SOFTWARE TO ANOTHER LANGUAGE YOU MUST SELECT THE DESIRED LANGUAGE ON THE PC AND THEN UPDATE THE TESTER LANGUAGE SD3NET LANGUAGE SETTING Fig 2 4 3 Page 20 SD3 Diagnostics System User Manual 2 5 Start PC Communications Menu The ST
34. not used since there are no higher level screens At page bottom the number of subscription days left will be displayed ATTIVAZIONE COMUNICAZIONE CON IL PC Page 14 SD3 Diagnostics System User Manual 2 3 SD3 System HW SW Information Menu Select INFORMATION to open a window see fig 2 3 1 displaying the version of the basic SD3 operating software the amount of space available in the Tester s non volatile memory Free Space on Disk and the Serial Number of the Tester which is also marked on the dataplate on the back of the device under the supporting platform Press Enter to return to the Main Menu You can print the displayed information by pressing Enter on the print icon 503 v V sD3NET INFORMATION ENVIRONMENT SD3 Sistema di Diagnosi Ferrari Maserati SYSTEM RELEASE BASIC SOFTWARE SD3NET LOADER VERSION MPC860 TESTER OPERATING SYSTEM APPLICATION SOFTWARE GRAPH DFC30 MANAGER UGL GRAPHICS PRIMITIVES 01 15 00 13 01 2004 01 16 03 12 2003 b2 08 03 12 2003 01 26 03 09 2003 1 01 04 23 12 2003 1 05 00 18 11 2003 TESTER DISK SPACE 55926784 bytes CA BATCH NUMBER SERIAL NUMBER 0001 0442 SISTEMA DIAGNOSTICO SD3 FERRARI MASERATI Fig 2 3 1 Page 15 SD3 Diagnostics System User Manual 2 4 SD3 Configuration Menu Select SD3 configuration to activate the menu where you can select from the possible Tester configurations Fig 2 4 1 Fig 2 4 1 Press Communications to select
35. on it shows the unblock environment 94 5 9 No tester in LAN available within the Communication selection environment 94 ER Ee e ee TEE 95 6 1 Diagnostics Software Operation ii 96 6 1 1 PG Error Men iii A iii 98 6 1 2 PC Parameter Meri nior ur e REPETI RARE PORA IS UHR RUE RATER 100 6 1 3 Cycle MENU perc viet dep m ee ni ee ai SG a ee 101 6 1 4 Acquisition Men nene de da E ep laiki pade lai 103 L e Lei e EE 106 7 1 Description ofthe ee ne EE 107 le EE 113 Page 3 SD3 Diagnostics System User Manual PRECAUTIONS AND SAFETY MEASURES Before connecting and starting up the SD3 diagnostics system you must study the operating instructions carefully especially the safety warnings This will eliminate any doubt about how the Tester is used from the very outset It will prevent you from running the risk of personal injury or damaging the unit The device is not user serviceable All repair procedures must be carried out by qualified personnel only Precautions against personal injury Use a suitable power cord To eliminate the risk of fire only use the supplied power cord or one specified for use with the device Avoid electrical overload To avoid the risk of injury and fire do not supply any of the device s inputs with more than the specified voltage Precautions against damage to the device Use a suitable power voltage Do not power the device with
36. or The red and black pins are used by the Voltmeter and the blue pins are used by the Ohmmeter Press Esc to return to the Tools Selection Menu Page 26 SD3 Diagnostics System User Manual 2 7 2 Data deleting The Data Deleting environment allows deleting the data on the Tester and to free space on the disk When the tester is switched on the data deleting environment shows a second submenu just like in figure 2 7 2 1 SD3HET PRIVATI CANCELLA TUTTE LE ACQUISIZIONI CANCELLA TUTTE LE STAMPE ESCI Fig 2 7 2 1 Selecting DELETE ALL DIAGNOSIS SW one will delete from tester all the diagnosis sw previously downloaded This means it will not be possible to execute them newly and in case of use it will be necessary to download them again Selecting DELETE ALL ACQUISITIONS one will delete from tester s disk all the present acquisitions Selecting DELETE ALL PRINTS one will delete from tester s disk all the prints After choosing one of the present entries the screen of the figure 2 7 2 2 will be displayed Page 27 SD3 Diagnostics System User Manual CANCELLA TUTTI SW DIAGNOSI CANCELLA TUTTE LE ACQUISIZIONI PROCEDO CON LA CANCELLAZIONE LA CANCELLAZIONE E IRREVERSIBILE PROCEDO CON LA CANCELLAZIONE LA CANCELLAZIONE E IRREVERSIBILE Fig 2 7 2 2 By pressing YES the deleting will be definitive and irreversible pressing NO one will return back to the previous menu 2 8 Expansions Menu
37. r Manual SD3 v e SD3NET m M139 NCR MASERATI F13 AMBIO ROBOTIZZATO MAGNETI MARELLI Pensa zm PRINT ERRORS FILE P1730 PUM PRINT ERRORS HAIT P1756 SV P1758 CLU P1790 CLU Fig 3 1 2 4 Press the DELETE icon to delete the errors from the ECU The screen which appears is similar to the one shown in fig 3 1 2 5 At the end of the procedure a window is displayed with the result of the delete as returned by the ECU Delete OK Delete Failed Page 50 SD3 Diagnostics System User Manual 503 v e SD3NET i M133 RCR INITIALIZED ECU Fig 3 1 2 5 Page 51 SD3 Diagnostics System User Manual 3 1 3 Parameters menu Select Parameters menu and press Enter to go to the dynamic parameters page The parameters are usually displayed sorted into dimensional types hence from the screen shown in fig 3 1 1 1 the program goes to a screen similar to the one shown in fig 3 1 3 1 Select them as for all other menus select using tab and arrow keys Enter to confirm Esc to return to the previous menu 503 M SD3NET M139 HER e MASERATI F133 NCR CAMBIO ROBOTIZZATO MAGNETI MARELLI NUMERICAL PARAMETERS 2 SNAPSHOT A0 A1 SNAPSHOT A2 A3 SNAPSHOT A4 A5 SNAPSHOT A6 Fig 3 1 3 1 Select one of the options and press Enter to go to a menu in which the Tester continuously prompts the ECU to determine the current value of the parameters The screen will be similar to the one shown in
38. sed The following operational description covers the standard diagnostics menu for a ECU developed in parallel with the SD3 itself and serves to give general indications on how the various diagnostics menus perform it should be understood that each diagnostics program will have its own specific documentation After the screen shown in fig 2 12 5 which may display for half a minute or so the real diagnostics software starts execution If execution is successfully completed a screen similar to the one in fig 3 1 1 1 will be displayed 503 v e SD3RET IC M139 RCR M139_NcR MASERATI F139 NCR CAMBIO ROBOTIZZATO MAGHETI MARELLI PARAMETER ENVIRONMENT ACTIVE DIAGNOSES ENVIRONMENT ACQUISITIONS ENVIRONMENT ECU IDENTIFICATION ENVIRONMENT EXIT Fig 3 1 1 1 The diagnostics main menu contains the various available menus in this case Errors Parameters Diagnostics Acquisition Information Exit Select the menus in the same way as for all other screens select with the arrows or tab keys Enter to confirm Esc to return to the previous menu From the program s main menu press Esc or select Exit and confirm to return to the ECU selection screen At the top the current selection is displayed FERRARI F137 NBC MARELLI Page 46 SD3 Diagnostics System User Manual Select Errors and press Enter to go to an menu in which the Tester continuously prompts the ECU for any errors stored in its memory It then displ
39. tor One Connector to hook up a CRT VGA monitor 1 7 Self test To quickly check that the device is functional connect the power supply for example with the cord and the mains power supply press the power button and check that the led lights up Within 20 30 seconds the start icon appears on the display The SD3 has a resettable fuse If it is activated because of an internal fault or due to the external cabling wait a few minutes to allow it to reset If when you switch on the SD the display does not light up wait a few minutes and repeat the procedure Fig 1 7 1 Page 9 SD3 Diagnostics System User Manual 3 m 880588 Fig 1 7 3 Page 10 SD3 Diagnostics System User Manual 1 8 Installing the Basic SD3NET software on the PC Always check the minimum system requirements To install the Basic SD3NET software on the PC proceed as follows 1 2 3 ooN 10 11 12 13 14 Power up the PC where the program has to be installed Insert the program CD supplied with the SD3 in the CD drive If the user has enabled the AUTORUN function on the CD drive the installation wizard will launch automatically in this case go to point 7 otherwise continue the procedure below Using your mouse double click on MY COMPUTER When the computer resources window opens double click on the CD icon where the SD3NET program has been inserted Double clicking opens a window showing the contents of the
40. tual meaning Pressing the print icon button writes on the Tester disk a file with the file name and the parameter values for the selected menu The screen which displays while the file is writing will look like the one shown in fig 3 1 3 3 These files can be transferred to the PC and printed out see par 4 4 The Tester stores them in non volatile memory and hence they will stay in memory even after the Tester is switched off From the Parameters Menu in fig 3 1 3 2 press Esc to return to the main diagnostics software menu shown in fig 3 1 3 1 Page 53 SD3 Diagnostics System User Manual ETI MARELLI PARAMETERS PRINT ENVIRONMENT HA Page 54 SD3 Diagnostics System User Manual 3 1 4 Diagnostics Menu Select the Active Diagnostics Menu and press Enter to send control signals to the ECU The Active Diagnostics menu is the one menu that could differ from one ECU to another the one described here is only one of the possible implementations The active diagnostics screen will look something like the one in fig 3 1 4 1 The various active diagnostics are arranged in a menu The various options are selected as in all other menus select using tab and arrow keys Enter to confirm Esc to return to the previous menu To exit from the help screen press Enter or Esc 503 y e SDSNET M ui29 ncn 4139 RCR MASERATI F133 NCR CAMBIO ROBOTIZZATO MAGNETI MARELLI FO DIAGNOSIS MENU 1ST GEAR ENGAGEMENT 2
41. turned on the SD3 Tester if nothing is displayed on the screen run the following checks Check that the Green light on the upper part of the Tester is on f this light is off check that the EOBD plug has been inserted into the vehicle correctly or if it is a 110 220 Volt network connection check whether the outside power supply is connected properly If the light is on wait 60 seconds and then try to reboot If the SD3 Tester still does not go on but the light is on reboot the tester by pressing KEYS 1 and 2 on the numeric keypad simultaneously and keeping them pressed for 20 seconds If the words WAIT FOR SOFTWARE DOWNLOAD appear on the screen download the Basic SD3NET PC program Operating System and then install the Basic SD3 SOFTWARE from the Update ECU SW screen REMEMBER IN PERFORMING THIS TYPE OF UPDATING YOU CAN ONLY USE THE SERIAL OR USB LINES FOR COMMUNICATIONS BETWEEN THE PC AND THE SD3 TESTER Should one be unable to sort out these problems please contact the After Market Service Page 44 SD3 Diagnostics System User Manual 3 SD3 Diagnostics Software Page 45 SD3 Diagnostics System User Manual 3 1 SD3 Diagnostics Software Operation The SD3 tester makes it possible to distribute and update diagnostics software developed as new vehicles are released Each diagnostics software will be different from all others depending on the particular ECU it tests and also the version of the software being u
42. ys several windows indicating what is currently installing Page 11 SD3 Diagnostics System User Manual 2 SD3 Operation Page 12 SD3 Diagnostics System User Manual 2 1 Start Screen When the SD3 is switched on an introductory screen appears see fig 2 1 0 displaying the FERRARI MASERATI logo this will remain on the display for a few seconds or until you press ESC SISTEMA DIAGNOSTICO SD3 FERRARI MASERATI Fig 2 1 0 If no keys are pressed for several minutes the SD3 goes into energy saving mode turning off the display light when the unit is in this mode just touch any key to simply switch on the display again Remember the continuous scrolling feature is implemented for the directional arrows and tab key feature hold one of these down to scroll through the list of options the cursor cycles back to the beginning when the end of the column or row is reached to prevent accidentally accessing other menus the other keys do not have this feature The start screen is shown in fig 2 1 0 Page 13 SD3 Diagnostics System User Manual Pressing Enter or Esc in the start screen calls up the Main menu see fig 2 2 1 The Main Menu provides access to the pages where you can configure the SD3 connect the PC for updates and where you can select and run the diagnostics programs To choose one of the options just highlight it with the up down arrows and or Tab key and press Enter In this screen the Esc key is
43. ze Frame Data are displayed if present These are the parameters that delimit an error present or saved at that moment in the ECU that the ECU saved when the problem occurred The error is reported on the first line of the screen as P CODE If there are no errors or if no data has been saved a special dialog box provides this information and invites you to continue To move through the windows use the SD3 tester keys following the rules indicated above in the paragraph on serial diagnostics See fig 2 9 5 503 v e SD3NET C EOBD zoso EOBD E BD FREEZE FRAME DATA EN PRIA NN a pires teri 7 d s TERR or i NAR aa 77 Fig 2 9 5 Service 03 Errors This menu does not present a previously selected ECU as mentioned above In fact all errors present in all currently active ECUs are reported as P CODE that is standardized alphanumeric code The particular node containing the error is indicated by displaying the address of the ECU itself next to the error code If a given DTC Diagnostic Trouble Code is present on more than one ECU all the addresses are displayed To move through the windows use the SD3 tester keys following the rules indicated above in the paragraph on serial diagnostics See fig 2 9 6 Page 33 SD3 Diagnostics System User Manual SD3 v QX sD3HET d osn C EOBD NO ERROR Fig 2 9 6 Service 04 Deleting errors Contrary to serial diagnostics
Download Pdf Manuals