Home

ART Power MINI 2000 (LCD)

image

Contents

1. Tel 90 216 365 82 21 pbx Faks 90216 420 97 70 Web VVVVVV artronic com tr E posta artronic artronic com tr
2. ARTronic ART Power MINI 500 LED ART Power MINI 1000 LCD ART Power MINI 2000 LCD INVERTER USER MANUAL Important Safety Information Before installing ART Power MINI 500 1000 1500 2000VA please read the following information carefully and save this manual for further reference Disregard of these safety notes may endanger life or health as well as the function of the equipment Special attention must be paid to the CAUTION and WARNING statements in this manual CAUTION 10 To reduce risk of injury charge ONLY lead acid type rechargeable batteries Other types of batteries may cause damage and injury DO NOT operate the ART Power MINI if it has been dropped or damaged in any way DO NOT expose ART Power MINI to rain snow or liquids of any type ART Power MINI is designed for indoor installation only NEVER charge a frozen battery DO NOT obstruct the ventilation openings Risks of electric shock Heat sinks are live Disconnect the AC sources and the DC source from this unit before servicing Risk of electric shock This unit receives power from more than one source Disconnect the AC sources and the DC source from this unit before servicing Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel The sum of the leakage current of the ART POWER MINI and the connected equipment should not exceed 3 5mA Risk of explosion if battery is incorrectly connected or rep
3. ies is an electronic product that has been designed and built to take lovv DC voltage povver from batteries and convert it to standard AC povver like the current you have at home The ART Povver MINI series is a DC to AC vvith auto line to battery transfer and integrated charging system ART Povver MINI series povvers from AC povver and DC source serving as an extended run UPS When AC cable is connected to a wall socket utility power goes to connected equipment s and or charges the battery set via charging system In UPS mode the ART Power MINI series automatically converts battery energy into AC power for backing up the connected devices Features Automatic line to battery switchover High efficient DC to AC conversion minimizing energy loss e Rack Tower design for flexible placement e Built in enhanced charger Intelligent 2 stage charger control for efficient charging and preventing overcharger Provides overload protection Auto restart while AC recovery Multi function LED LCD indications and buzzer alarms Operation amp Installation 1 Front Panel Controls and LED Indicators Shown below are the controls and indicator lights on the front panel of ART Power MINI series OUTPUT LED LED SERIES FAULT LED INVERTER MODE LED 1 il MAINS MODE LED POWER ON OFF Power On Off Power ON OFF button is shown as above Once inverter has been properly installed and batteries are connected press this butto
4. inuously ENVIRONMENT 0 40 C Lovv Battery Voltage in Battery Mode Beeps every 2 seconds AUDIBLE ALARM 7 mm 7 249x270x93 PHYSICAL Net Weight Kg 3 1Kg 3 6Kg 3 9Kg 3 9Kg Deep Discharge Overcharge Short Circuit Overload Battery Short Over Voltage Under Voltage 11 Troubleshooting 1 Battery VVeak Re charge battery No LED LCD display Battery defective 2 Battery replacement 2 Power switch is not 3 Press and hold power pressed switch 1 AC Input missing 1 Check AC input Mains normal but connection works in inverter mode 2 Input protector is effective 2 Reset the input protector 1 Verify that the load matches the capability specified in the specs 1 Remove some non Overload iti critical load Back up time is not enough Battery voltage is too low a 7 7 If any abnormal situations occur that are not listed above please call service personnel immediately Alarm buzzer beeps Overload continuously Appendix A Input output cables gauge Battery cables Models copper wire gauge copper wire SOOVAMAVDC 12VDC At Atleast20AWG 20AVVG At Atleast10AWG 10AWG 1000VA 12VDC At least 20AVVG At least SAWG 1500VA24VDC At least 18AWG At least SAVVG 2000VA24VDC At least 18AVVG At least SAVVG 12 ARTronic The art of electronics ARTronic Elektronik San M m Tic A S Adres MES Sanayi Sitesi Kap s Kar s Kuru Sk No 26 Y Dudullu stanbul
5. laced VVARNING 1 Provide adequate ventilation from the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment Input output AC wiring and battery cables must be rated for 75 C or higher Using cables diameter please refer to appendix A according to different models The inner diameter of the copper ring terminal vvhich is used to connect battery cables to ART Povver MINI DC terminals should be no less than mm For battery installation and maintenance read the battery manufacturer s installation and maintenance instructions prior to operating PERSONAL PRECAUTIONS 1 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes Avoid touching eyes while working near batteries NEVER smoke or allow a spark or flame in the near vicinity of a battery Remove personal metal items such as rings bracelets necklaces and watches while working with batteries Batteries can produce short circuit current high enough to make metal melt and can cause severe burns lf a remote or automatic generator start system is used disable the automatic starting circuit or disconnect the generator to prevent accident during servicing INTRODUCTION Thanks for purchasing the ART Povver MINI 500 1000 1500 2000VA Properly used this product vvill give you many years of reliable service The ART Power MINI ser
6. motor or inductive load such as the fridge of 1KW the motor of 800W air cooler PC having risk of rebooting and so on In this mode the Inverex series operating voltage in mains mode is within 170 280Vac with the same output voltage The line sensitivity is higher B Select VVide setting to save energy n this mode the operating range of voltage for the Inverex is 90 280Vac hence the output voltage will be the same as the MAINS input voltage The Inverex unit in this mode has a lower sensitivity You can connect and use only for some special load such as lamp fan AC Input Connections Battery Connection Step 1 Pinch the bottom of DC input cover and Open it Step 2 Following battery polarity guide located near battery terminal Tighten the M5 nut Do not place anything between the flat part of battery terminal and the battery cable rig terminal or overheating may occur Caution DO NOT place anything between battery cable ring terminals and battery terminals The terminal stud is not designed to carry current Apply Anti oxidant paste to terminals after terminals have been torqued Battery Cable Connection 8 Step 3 Connect battery cables to your batteries The battery must be vvired to match the units DC input voltage specifications 12V for ART Power MINI 500 1000 24V for ART Power MINI 1500 2000 12 24V Battery ART Povver MINI In addition the batteries can be wired to provide additional r
7. n and Inverter will turn on automatically and works in mains mode or inverter mode according to input AC sources status When press this button again Inverter will turn off automatically Mains Mode LED The green LED will blink or light steadily when power mains is normal Inverter Mode LED The Yellow LED will light when power mains is abnormal And unit will work in inverter mode Fault LED The red LED will light when fault occurs 2 Front Panel Controls and LCD Indicators Shovvn belovv are the controls and indicator lights on the front of Digital ART Povver MINI LCD SERIES LED POWER ON OFF LCD Display Specification When press the pouer suitch lightly the INVERTER works in normal mode Including in off charging mode and fault mode when LCD start to work it will display all information for 3s _ _ 5 INPUT BATTERY QUTPUT LQAD FALILT LOAD LEVEL BATTERY CAPACITY LINE MODE BACKUP MODE 1 When in normal mode it will display as below 2 When in battery mode it will display as below And the mark will flicker every 1 second 3 When in fault mode it will display as below FAULT character and the reason of fault only Note the fault code vvill be shovved in fault mode 4 Load level definition Load level Load bar indication 5 Battery capacity definition level Battery bar indication Battery voltage 11 22V Batter
8. un time The various wiring configurations are as follows Series Connection Wiring batteries in series increases the total output voltage This voltage MUST match the DC voltage requirements of the ART Power MINI unit or it may damage both the ART Power MINI unit and or the batteries z l ART Power MINI F 500 1000VA 12W Battery m ART Power MINI 1500 2000VA Parallel Connection Wiring batteries in parallel increases the total run time the batteries can operate the AC loads The more batteries connected in parallel the longer run time the loads can be povvered from the ART Power MINI unit ART Power MINI 500 1000VA O Series Parallel Connection Series parallel configuration increases both the battery voltage to match the DC requirements of ART Povver M N unit and run time for operating the AC loads Battery ART Power MINI 1500 2000VA 12 Battery 10 SPECIFICATION MODEL ART Power ART Power ART Power ART Power MINI 500 VA MINI 1000 VA MINI 1500 VA MINI 2000 VA CAPACITY 300W 1000VA 600W 1500VA 900W 2000VA 1200VV Nominal 220 230 240VAC nput Voltage Range 170 280 or 90 280VAC Nominal Frequency 50 60Hz Auto Detection INVERTER MODE OUTPUT Modified Sine wave Efficiency Efficiency DC to AC to AC gt 80 COUTO a TRANSFER Transfer Time Time Typical 8ms 20ms max Beeps every 0 5 second Beeps cont
9. y voltage 11 11 5V 22 23V Battery voltage 11 5 12 5V 23 24V Battery voltage lt 12 5 25V 26 will flicker every 1 second 6 VVhen over load the mark 7 When battery low the mark vvill flicker every 1 second Rear Panel amp Output Description Shovvn belovv are the components on the rear panel of ART Povver MINI series H 5 00000 00 0000 0 O OOOO EH Enn Hn nx Ennnun nooo nooo 0 233 3 22 030 0 3 1 mimimimimimimimimimimim 23 o DC Input Connector Battery Terminal AC Input Connector Output Receptacle s Input Voltage Range Selector Input voltage range is defined in 70000 AC connection Before having AC connection match the power requirements of connected devices with the power output of ART Power MINI to avoid overload Consult a qualified electrician and follow local code for the proper wire sizes connectors and conduit requirements A Select Narrow setting for general electrical appliance such as tube light energy saving lamp TV Juicer amp mixer etc but it is not suitable to meet high power

Download Pdf Manuals

image

Related Search

Related Contents

Uniden 6035 + 1 Cordless Telephone User Manual  Enterovirus Real Time RT-PCR Kit User Manual For In Vitro  Avaya 1400 Series DCP phones User's Manual  NETWORK POWER MONITOR R8 / NPM-R8  Juliet-PK  

Copyright © All rights reserved.