Home

Sono-Trak® Doppler

image

Contents

1. An internal super capacitor allows the electronics assembly to retain all parameter information and current totalizer value for up to ten days Power Failure Backup Ul 2 Pa emco flow systems Standard Interface LCD Display LED Indicators 2 line 16 characters per line high resolution Yellow Echo signal received High alarm or low alarm activated Green Power available 12 keys tactile feedback Note Keypad lockout is available through internal switch Keypad Display Panel Rate selection Totalizer selection K factor selection Analog output set Low flow cutoff set Update time damping set High low alarm set Fps or mps selection Totalizer reset Output Setting Function 4 to 20 mA output scaling set in velocity from keypad High and low alarm set points entered in velocity from keypad Alarm Setting Function Rate Indication 4 digit LCD velocity or volume user selectable Feet per second fps gallons per minute gpm cubic feet per second English units and million gallons per day Note Gallons refers to U S gallons Metric units Meters per second mps liters per second lps and cubic meters per second Totalizer Indication 11 digit LCD English units Gallons cubic feet acre feet and millions of gallons Note Gallons refers to U S gallons Metric units Liters and cubic meters Update Time Damping 0 to 99 sec entered from keypad Low Flow Cutoff 0 to 2 5 fps 0 to 0 76 m
2. Electronics Enclosure Transducers 12 O clock Position Cross Section of Pipe with Mounted Transducers 6 O clock Position Figure 1 Mount the transducers side by side between 7 and 11 o clock Figure 2 Secure the transducers in place Cabling The standard cable length between the electronics enclosure and the transducers is 25 7 6 m Custom cable lengths up to 5000 1524 m are available Display Module A user friendly easy to read display provides continuous real time flow rate velocity and totalization measurements in user selectable engineering units On screen prompting and a full function 32 character dual line alphanumeric keypad entry make programming effortless The display reads pulse voltage and analog rates and it includes built in high low limit alarms 4 to 20 mA signals and an echo light to indicate whether the signal is producing accurate readings 3 Pa emco flow systems Specifications Fluid Conditions Measured Fluid Homogenous liquids with Newtonian flow profiles sludges slurries sewage wastewater and other fluids containing suspended particles State of Flow Axis symmetric flow in pipe filled with fluid Fluid Type Liquids containing suspended particles of at least 35 ppm at 40 u at 0 2 density of undissolved solids or air bubbles Measurable Fluid 40 to 300 F 40 to 149 C Temperature Range Velocity Range 0 1 to 40
3. FLOW SYSTEMS EMC 0da Sono Trak Doppler Ultrasonic Flow Meter The Sono Trak Doppler ultrasonic flow meter is a non invasive ultrasonic flow metering system Based on the principles of the Doppler effect it calculates flow velocity by sensing and measuring the frequency shift in motion from reflective materials within a liquid Benefits e Non invasive design e Low cost simple installation Fits pipe sizes from 1 to 100 25 to 2540 mm outside diameter Rugged and maintenance free no moving parts No pressure drop and no costly process shutdowns Reliable and accurate flow readings typically provides 2 0 full scale accuracy and 0 1 repeatability Features e Automatic gain control as flow profile changes so does the electronics signal e Noise immunity to variable frequency drive VFD e User friendly easy to program display with on screen prompting and keyboard entry e Digital signal allows for cable lengths up to 5000 1524 m e AC or DC operation e Fixed and portable units available Overview The Sono Trak Doppler flow meter uses advanced signal processing technology that dramatically increases the accuracy of flow rate measurement Its accuracy ratings are typically 2 0 of full scale accuracy and repeatability is 0 1 of reading This flow metering system uses two transducers mounted side by side operating as ultrasonic signal transmitters and rece
4. fps 0 04 to 12 19 mps Flow Sensitivity 0 05 fps 0 02 mps Piping Conditions Pipe Diameter Range Volumetric indication 1 to 100 25 to 2540 mm diameter Pipe Including but not limited to carbon steel stainless steel ductile iron cast iron FRP PVC fiberglass Teflon and most concrete lined or coated pipes Pipe Lining Including but not limited to tar epoxy mortar rubber Teflon PVC and glass Measurement Accuracy Accuracy Typically 1 to 3 of full scale based on straight run of piping of 20 diameters upstream and 10 diameters downstream Note Accuracy is a function of flow profile 3 to 5 of full scale based on straight run of 10 diameters upstream and 5 diameters downstream 5 to 10 of full scale based on straight run of 5 diameters upstream and 3 diameters downstream Linearity 0 5 of full scale Repeatability 0 1 of full scale Response Time lt 1 sec Electronics Enclosure Dimensions 9 21 H x 7 21 W x 5 09 D 285 mm x 183 mm x 129 mm Weight 12 Ib 5 45 kg Materials Flame retardant fiberglass reinforced polyester with lockable latch gray in color Environmental Rating NEMA 4X IP65 Ambient Temperature Range 13 to 132 F 25 to 55 C lt 100 RH Ambient Humidity A general specifications a Transducers Transducer heads 4 85 L x 1 33 W x 1 35 D 123 mm x 33 8 mm x 34 3 mm Daaa Digitizer 4 45 L x 2 50 W x 1 10 D 113
5. ivers The measurement is obstructionless and produces no associated pressure drops With no moving parts to wear over time the Sono Trak Doppler flow meter is virtually maintenance free and is available in both fixed and portable units Suitable Fluids The Sono Trak Doppler flow meter is suitable for fluids containing suspended particles or bubbles with at least 35 parts per million ppm at 40 p or larger and a minimum of at least 0 2 density difference from liquid medium Pa emco flow systems Applications e The Sono Trak Doppler flow meter easily measures most all liquids containing particles or air bubbles Some materials well suited for measurement include Agricultural water Abrasives Asphalts Concrete Drudge flows Drilling mud Large contaminates Extremely viscous substances e Grout Hazardous wastes Municipal sludge and wastes Paper pulp Rendering products Reservoirs and runoffs Rivers and streams e Sludge e Slurries e Suspended solids Installation Considerations The Sono Trak Doppler flow meter is available in fixed and portable units The fixed unit consists of e Electronics enclosure e Digitizer e Two transducers and 25 cable 7 6 m e Tiedown kit e Sonic coupling gel e User manual In addition portable units include e 12 V 2 2 AH battery e 110 VAC battery charger o Tote handle and side latch e Field transport case Custom cable leng
6. mm x 63 5 mm x 28 mm Weight 2 3 Ib 1 kg Housing Material Cast aluminum Mounting Mount to the outside of pipe by means of stainless straps nylon belts or bungee and steel chain Crystal Wedge Material Epoxy resin all transducer models Environmental Rating NEMA 6 IP67 Ambient Temperature Range 4 to 130 F 20 to 54 C Ambient Humidity lt 100 RH Transducer Cable Standard Cable 25 7 6 m 2 twisted pairs 24 AWG belfoil shield Note Custom cable lengths are available Maximum cable length 5000 1524 m Power Fixed Units 110 VAC or 220 VAC at 50 60 Hz AC line voltage selectable via internal selector switch 12 VDC DC operation enabled by internal selector switch Portable Units Internal gel cell 8 hour continuous operation built in battery Recharge time is 12 hours using the external power adapter charger or DC auto cigarette lighter Power Adapter Charger Standard adapter 115 VAC 50 60 Hz 10 input delivering 12 VDC 500 mA output Optional adapter 230 VAC 50 60 Hz 10 input delivering 12 VDC 500 mA output 10 W typical Power Consumption 4 to 20 mA DC 700 Q maximum load resistance internally fused active output Analog Output Signal Alarm Output When on AC power 15 VDC Active alarm High alarm switched 15 VDC 500 mA Low alarm switched 15 VDC 500 mA When on battery power 12 VDC Active alarm High alarm switched 12 0 VDC 500 mA Low alarm switched 12 0 VDC 500 mA
7. ps entered from keypad A value of 1 to 256 entered from the keypad depending upon sensor type default is 90 Hz correction factor K Factor Totalizer Reset Totalizer can be manually reset to zero from the keypad general specifications a gt Mo Sono Trak Doppler 233 93 mm 9 21 2723 129 29 mm 5 09 Power Cable Transducer Cable Alarms 4 to 20 mA Access Access Access fixed unit options only Figure 4 1 Dimensions Pa emco flow systems Fixed and Portable Models The Sono Trak Doppler flow meter is available in fixed wall mounted models or portable models Fixed Sono Trak Doppler Inclusions Portable Sono Trak Doppler Inclusions The complete EMCO product line for liquid gas and steam applications includes industrial inline vortex industrial insertion vortex and turbine commercial vortex electromagnetic and clamp on ultrasonic flow products For more information refer to the EMCO Industrial Flow Product Guide www emcoflow com FLOW SYSTEMS EMCO a For information on EMCO industrial flow products contact EMCO Flow Systems e 2150 Miller Drive e Longmont CO 80501 E EE Pana ASA T 800 356 9362 or 303 682 7060 e F 303 682 7069 e sales emcoflow com e www emcoflow com SL ST Doppler 350 03 2M 2 07 Sono Trak is a registered trademarks of Spirax Sarco Inc
8. ths of up to 5000 1524 m are available Doppler Placement The ideal placement of the Sono Trak Doppler flow meter is within 20 diameters of straight run upstream and 10 diameters of straight run downstream between the meter and any disturbance of the flow however the meter has worked with straight runs of as little as 5 diameters upstream and 2 diameters downstream Piping Conditions The Sono Trak Doppler flow meter fits pipe diameters from 1 to 100 25 to 2540 mm e Pipes should be cleaned with all paint and scale removed e Horizontal pipe mounting is recommended Clamp on mounting The Sono Trak Doppler flow meter is configured with clamp on transducers When installed the transducers sense fluid flow through a pipe and send this information to the system electronics The electronics then convert transmit and display the received data External clamp on sensors are ideal for smooth clean pipe surfaces and are installed without shutting down flow When clamp mounting the flow meter attach the sensors side by side in a position approximately 7 to 11 o clock on the outside of the pipe Use stainless straps nylon belts or bungee straps and a steel chain to secure the clamps in place general specifications a Use only a sonic coupling medium to transmit the energy from the transducer crystals through the pipe wall and into the flow to be measured Any type of non fibrous grease or gel will suffice