1. Oona WN Purifire Filter The Purifire filter supplied in your fireplace is reusable and washable The filter should be cleaned or replaced on average once a year To clean the filter gently tap filter on a hard surface to dislodge any loose dirt or debris and then clean with water No soap or cleaning products are recommended The filter size is 20 x 10 x 1 inches rated at MERV 10 17 www sylvane com 1 800 934 9194 To replace filter 1 Remove fireplace from mantel 2 Filter can be accessed from the top rear of the unit Figure 8 3 Grasp filter and slide filter is straight up T 4 Replace or clean filter Figure 8 Purifire Filter NOTE If after market air filter is used ensure it is installed according to the J manufacturer s recommended instructions ete Glass Cleaning The glass is cleaned in the factory during the assembly operation During shipment installation handling etc the glass may collect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the glass can be cleaned with a damp cloth To prevent scratching do not use abrasive cleaners or spray liquids on the glass surface Fireplace Surface Cleaning Use a cloth dampened with warm water only to clean painted surfaces of the electric fireplace Do not use abrasive cleaners 18 www sylvane com 1 800 934 9194
2. Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 5 www sylvane com 1 800 934 9194 Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Model and Serial Number Information If you have any questions regarding our products please have the product model and serial numbers available upon calling Dimplex customer service or technical support To locate the model and serial number labels see below Figure 1 Record the Model number Serial number and CAT number on the front cover of this manual for future reference Figure 1 Serial Number SERIAL No XX Model Number Part Number Al eS RSK OF ELECNE HOHE o NOT OPEN CALEN TADO DE JO NO USER m ies INSIDE vec 120 W MODEL NO ISQUE o ec FLECTROUE grid UVRIR E71416 AUCUNE PIECE eel A TAER A CINTERIEUR MADE IN an WIS paras RIESGO DE ERE RD NO ABRIR 4 995 707 AND 5 642 580 NO HAY PARTES ADENTRO QUE EL USUARIO PUEDA REPARAR FURTHER PATENTS PENDING CSSSS3 Bel www sylvane com 1 800 934 9194 Site Selection and Pr
3. Sleep Timer Down Sleep Timer Up Purifire Speed Down Purifire Speed Up Press H Flame amp Heat On Off button 4 to turn fireplace on Press J Temperature Up to raise thermostat or I Temperature Down to lower the thermostat Press both J Temperature Up and I Temperature Down to change F to C C Light Dimmer Control While the fireplace is running repeatedly press the L Dimmer Up or 12 www sylvane com 1 800 934 9194 K Dimmer Down button to increase or decrease the brightness of the upper lights D Flame Speed Control While the fireplace is running press the N Flame Speed Up button to increase the speed of the flame or press the M Flame Speed Down to decrease the speed of the flame E Sleep Timer The Sleep Timer automatically shuts off the fireplace after a preset time from 30 minutes to 8 hours During fireplace operation to set the sleep timer press the P Sleep Timer Up button Set the timer from 30 minutes through 8 hours The fireplace will automatically turn off when the sleep timer reaches zero 0 minutes The sleep timer can be cancelled at any time by pressing the O Sleep Timer Down button repeatedly until the sleep timer displays 0 F Purifire The Purifire includes a high efficiency filter to help improve the quality of air Press the G Purifire On Off button to turn the Purifire function on When the Purifire function is on the Purifire sym
4. Five Year Limited Warranty Products to which this limited warranty applies This limited warranty applies to the following model of your newly purchased Dimplex electric fireplace DF3015 and to newly purchased Dimplex fireplace surrounds mantels and trims This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory Nunavut or Northwest Territories or in any of the 50 States of the USA and the District of Columbia except for Hawaii and Alaska This limited warranty applies to the original purchaser of the product only and is not transferable Products excluded from this limited warranty Light bulbs and Purifire filters are not covered by this limited warranty and are the sole responsibility of the owner purchaser Products purchased in Yukon Territory Nunavut Northwest Territories Hawaii or Alaska are not covered by this limited warranty Products purchased in these States provinces or territories are sold AS IS without warranty or condition of any kind including without limitation any implied warranties or conditions of merchantability or fitness for a particular purpose and the entire risk of as to the quality and performance of the products is with the purchaser and in the event of a defect the purchaser assumes the entire cost of all necessary servicing or repair What this limited warranty covers and for how long Products other than fireplace surrounds mantels and tri
5. costs and transportation costs to and from the authorized dealer s or service agent s business and all labour costs Such costs shall not be the responsibility of Dimplex On site or in home services not provided under this warranty may be performed at the purchaser s specific request and expense at Dimplex s then current rates for such services What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CONTRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUNITIVE EXEMPLARY CONSEQUENTIAL OR INCIDENTAL LOSS COST OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE MAINTENANCE USE OR INABILITY TO USE THE PRODUCT EVEN IF DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH 21 www sylvane com 1 800 934 9194 LOSSES COSTS OR DAMAGES OR IF SUCH LOSSES COSTS OR DAMAGES ARE FORESEEABLE IN NO EVENT WILL DIMPLEX OR ITS OFFICERS DIRECTORS OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES COSTS OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER How State and Provincial law apply This limited warranty gives you specific legal rights and you may also have o
6. bol will flash When off the symbol will be solid The default setting for the Purifire is set at low speed Press the Q Purifire Speed Down or the R Purifire Speed Up buttons to change between low and high speeds Press the G Purifire On Off button to turn the Purifire function off H Flame amp Heat On Off Button Press the H Flame amp Heat On Off button 4 to turn the Flame Heat function on When B Set Temperature is higher then A Room Temperature the heat will come on To turn the heat off lower the B Set Temperature so that it s setting is lower then the A Room Temperature The default temperature setting is 72 F 22 C NOTE When using the remote control the heater runs on a thermostat Press the J Temperature Up or Il Temperature 13 Child Lock Figure 5 1 Move Child Lock tab www sylvane com 1 800 934 9194 Down buttons to adjust the set temperature Once the desired set temperature is reached the heater will turn off The heater will cycle on and off to maintain the desired set temperature Figure 5 Depress tab on the Unlocked Locked battery cover on the back of the remote e transmitter and remove ayia a the battery cover E a H Move Child Lock tab to the right to lock the AAR remote transmitter Child Lock Tab back to the left to unlock the remote transmitter Replace the battery
7. ch is in the Flame and Flame amp Heat positions the fireplace unit will not operate with the remote control Initialization Button Used to synchronize the supplied remote control with the fireplace Remote Control The remote control has a range of approximately 50 feet 15 25 m it does not have to be pointed at the fireplace and can pass through most obstacles including walls Itis supplied with 243 independent frequencies to prevent interference with other units Battery Installation 1 Figure 4 Depress tab on the battery cover on the back of the remote transmitter and remove battery cover l Install two 2 AAA batteries into the Baligiics N remote control included Ensure Child Lock is in the unlocked Child Lock position Figure 4 r Replace the battery cover NOTE When the BAT symbol is present on the remote control it is recommended to replace the batteries promptly to maintain full functionality of the remote fireplace The remote transmitter has a battery backup time of only several hours 10 www sylvane com 1 800 934 9194 Remote Control Initialization 1 2 Plug cord into a 120 Volt wall outlet Ensure the Main On Off Switch located in the switch box on the fireplace in the lower right hand corner is in the On position Set the Three Position Manual Control Figure 3B to the Remote po
8. cover NOTE To temporarily unlock the remote transmitter press in order Temperature Down then J Temperature Up then K Dimmer Down When the remote transmitter s backlight is illuminated the Child Lock is bypassed When the backlight is off the Child Lock is re activated Frequency Interference If the fireplace does not respond properly to the remote control the remote operating frequency may have to be reset The remote control can send another frequency code to the circuit board to eliminate interference 1 Simultaneously press the O Sleep Timer Down button and the Q Purifire Speed Down button on the remote control COD will appear in place of the sleep timer digits Release the O Sleep Timer Down button and the Q Purifire Speed Down button Press the Initialization button on the unit Figure 3C 14 www sylvane com 1 800 934 9194 5 Press the H Flame amp Heat On Off 4 button on the remote Your remote will now have a different frequency communicating with the fireplace Maintenance WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire electric shock or damage to persons Light Bulb Replacement Allow at least five 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log
9. crew bulbs counter clockwise Figure 7 Log Ember Bed Set Log Set Assembly in front of fireplace Disconnect the Log Set Assembly s LED wire harness from unit 9 Insert new bulbs and screw in clockwise 10 Reconnect the LED wire harness 11 Install the Log Set Assembly by placing the front bottom edge of 16 www sylvane com 1 800 934 9194 the Ember Bed in the track behind the control panel Once in place push down on the back edge of the Ember Bed until the rear tab snaps into place under the Mirror Figure 7 NOTE Ensure the Log Set Assembly is installed tightly under the back ledge to prevent light leakage 12 Slide front glass back into position and attach trim Upper Light Bulb Requirements Quantity of two 2 clear chandelier or candelabra bulbs with an E 12 small socket base 15 Watt rating Do not exceed 15 Watts per bulb To access the upper light bulb area Slide fireplace out of mantel Remove four 4 Phillips screws from right side of trim Figure 6 Remove trim Slide glass to the right side of the fireplace to remove Figure 6 Remove Upper Light Bracket Figure 6 Upper bulbs are located in the upper left and upper right corners of the fireplace 7 Unscrew bulbs counter clockwise 8 Insert new bulbs and screw in clockwise 9 Re install Upper Light Bracket 10 Slide front glass back into position and attach trim
10. ember bed exterior disappears There are three 3 bulbs under the log set assembly which generate the flames and embers and two 2 bulbs above that illuminate the log exterior Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the number of times you need to open the unit to replace light bulbs Care must be taken when removing the log set as the log set contains LED s and wires Lower Light Bulb Requirements Quantity of three 3 clear chandelier or candelabra bulbs with an E 12 small socket base 60 Watt rating Example GE 60BC or Philips 60CTC Do not exceed 60 Watts per bulb To access the lower light bulb area 1 Slide fireplace out of mantel 2 Remove four 4 Phillips screws from right side of trim Figure 6 3 Remove trim 15 www sylvane com 1 800 934 9194 Figure 6 Upper Light Bracket Upper Bulbs Lower Bulbs Log Set Assembly Front Glass Trim 4 Slide glass to right side of fireplace to remove Figure 6 5 Pull the front edge of the plastic Log Set or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the mirror Figure 7 IMPORTANT Only handle the Log Set Assembly by the Ember Bed or plastic grate NOTE Log Set Assembly fits tightly into firebox some force may be necessary to remove co NO Uns
11. eparation This section provides instructions for selecting a location and preparing the site to install the fireplace into your Dimplex mantel surround 1 Select a suitable location that is not susceptible to moisture and is away from drapes furniture and high traffic For ease of electrical hook up you may wish to locate the fireplace near an existing outlet refer to NOTE 1 Store the fireplace in a safe dry and dust free location NOTE 1 A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the current rating of the circuit breaker WARNING Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire electric shock or injury to persons Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electric shock and injury to persons Do not attempt to wire your own new outlets or circuits To reduce the risk of fire electric shock or injury to persons always use a licensed electrician NOTE The dimensions of the fireplace are 30 1 4 inches 768 mm
12. ers or service agents of Dimplex authorized to provide limited warranty services e For products other than surrounds mantels and trims for the period ending at midnight on the first anniversary of the date of first purchase Dimplex will in its sole discretion either repair or replace such defective product or part without charge If Dimplex is unable to repair or replace such product or part or if repair or replacement is not commercially practicable or cannot be timely made Dimplex may in lieu of repair or replacement choose to refund the purchase price for such product or part This limited warranty entitles the purchaser to on site or in home warranty services Accordingly Dimplex will be responsible for all labour and transportation costs associated with the repair or replacement of the product or part except as follows i charges may be levied for travel costs incurred to travel to the purchaser s site where the product is located if the purchaser s site is beyond 30 miles 48 km from the closest 20 www sylvane com 1 800 934 9194 service depot of Dimplex s dealer or service agent and ii the purchaser is solely responsible for providing clear access to all serviceable parts of the product For products other than surrounds mantels and trims for the period commencing at 12 01 a m on the day after the first anniversary of the first purchase and ending at midnight on the fifth anniversary of the date of first purc
13. for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or other water container 8 Do not run the cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over 9 To disconnect the unit turn the controls off then remove the plug from the outlet 10 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage to the heater 11 To prevent a possible fire do not block air intake or exhaust in any manner Do not use on soft surfaces like a bed where openings may become blocked 12 All electrical heaters have hot and arcing or sparking parts inside Do not use in areas where gasoline paint or flammable liquids are used or stored or where the unit will be exposed to flammable vapors 13 Do not modify the electric fireplace Use it only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons www sylvane com 1 800 934 9194 14 Avoid the use of an extension cord Extension cords may overheat and cause a risk of fire If you must use an extension cord the cord must be No 14 AWG minimum size and rated no less than 1875 Watts 15 Do not burn wood or other materials in the electric fireplace 16 Do not strike the fireplace glas
14. hase this limited warranty entitles the purchaser to replacement parts only without charge If Dimplex is unable to replace such part or if replacement is not commercially practicable or cannot be timely made Dimplex may in lieu of replacement choose to refund the purchase price for such part The purchaser shall not be entitled to on site or in home warranty services The purchaser shall be responsible for all expenses incurred for the removal of the part and installation of the replacement part including without limitation all shipping costs and transportation costs to and from the authorized dealer s or service agent s place of business and all labour costs Such costs shall not be the responsibility of Dimplex For surrounds mantels and trims for the period ending at midnight on the first anniversary of the date of first purchase Dimplex will in its sole discretion either repair or replace such defective surrounds mantels and trims or part thereof without charge If Dimplex is unable to repair or replace such product or part or if repair or replacement is not commercially practicable or cannot be timely made Dimplex may in lieu of repair or replacement choose to refund the purchase price for such product or part The purchaser shall not be entitled to on site or in house services The purchaser is responsible for all expenses incurred for repair or replacement of such product or part including without limitation all shipping
15. ial Number Information PAGE 6 Site Selection and Preparation PAGE 7 Fireplace Installation PAGE 8 Operation o n a vena eee att eck mete PAGE 9 Maintenance 2 2 6 5 os ee eda eeeae eau PAGE 15 Warranty aaa wey ha o s eee i PAGE 19 www sylvane com 1 800 934 9194 IMPORTANT INSTRUCTIONS Please Retain This User s Guide For Future Reference When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before using the electric fireplace 2 The heater is hot when in use To avoid burns do not let bare skin touch hot surfaces The trim around the heater outlet becomes hot during heater operation Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from the front of the unit 3 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the unit is left operating and unattended 4 Always unplug the electric fireplace when not in use 5 Do not operate any unit with a damaged cord or plug or if the heater has malfunctioned or if the electric fireplace has been dropped or damaged in any manner Return heater to authorized service facility for examination electrical or mechanical adjustment or repair 6 Do not use outdoors 7 The electric fireplace is not intended
16. ies to any implied warranties that may exist under applicable law Some jurisdictions do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to the purchaser What this limited warranty does not cover This limited warranty does not apply to products that have been repaired except by Dimplex or its authorized service representatives or otherwise altered This limited warranty does further not apply to defects resulting from misuse abuse accident neglect incorrect installation improper maintenance or handling or operation with an incorrect power source What you must do to get service under this limited warranty Defects must be brought to the attention of Dimplex Technical Service by contacting Dimplex at 1 888 DIMPLEX 1 888 346 7539 or 1367 Industrial Road Cambridge Ontario Canada N1R 7G8 Please have proof of purchase catalogue model and serial numbers available when calling Limited warranty service requires a proof of purchase of the product What Dimplex will do in the event of a defect In the event a product or part covered by this limited warranty is proven to be defective in material or workmanship during i the 5 year limited warranty period for products other than fireplace surrounds mantels and trims and ii the 1 year limited warranty period for surrounds mantels and trims you have the following rights e Limited warranty service will be performed solely by deal
17. ms covered by this limited warranty have been tested and inspected prior to shipment Subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 5 years from the date of the first purchase of such products as follows a a repair or replacement warranty on defective products or parts including in home services for the first 1 year following the date of first purchase and b thereafter a replacement of parts warranty on defective products and parts with no in home services for the 4 year period commencing on the first anniversary of first purchase and ending on the fifth anniversary of the date of first purchase Dimplex fireplace surrounds mantels and trims covered by this limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 1 year from the date of first purchase of such products Warranty services do not include in home services The above section is a summary only of your warranty rights Please review the remaining provisions of this warranty for your specific rights 19 www sylvane com 1 800 934 9194 The limited 5 year warranty period for products other than fireplace surrounds mantels and trims and the limited 1 year warranty period for fireplace surrounds mantels and trims also appl
18. s 17 Always use a certified electrician should new circuits or outlets be required 18 Always use properly grounded fused and polarized outlets 19 Disconnect all power supply before performing any cleaning maintenance or relocation of the unit 20 When transporting or storing the unit and cord keep in a dry place free from excessive vibration and store so as to avoid damage CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICABLE PARTS INSIDE SAVE THESE INSTRUCTIONS NOTE Procedures and techniques that are considered important enough to emphasize amp CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment amp WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury illness or death NOTE This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures
19. sition right position Press and hold the Initialization Button on the unit Figure 3C While holding the Initialization Button press the Flame Heat On Off button 4 or the Purifire On Off button B on the remote control transmitter Release the Initialization Button on the unit Press the Flame Heat On Off button 4 to turn the Flame Heat function on or press the Purifire On Off button to turn the Purifire function on Resetting The Temperature Cutoff Switch Should the heater overheat an automatic switch will turn the heater off and it will not come back on without being reset The temperature cutoff switch can be reset by unplugging the unit waiting five 5 minutes and plugging the unit back in amp CAUTION If you need to continuously reset the heater unplug the unit and call Dimplex North America Limited at 1 888 346 7539 Please have your model and serial number ready when calling 11 www sylvane com 1 800 934 9194 Remote Control Functions B roam mooaD gt pD PE feat er eto Room Temperature Set Temperature Light Dimmer Control Flame Speed Control Sleep Timer Purifire Purifire On Off Flame amp Heat On Off Temperature Down Set Temperature Ls SEZ Nw 30O Sc Dimplex POMOZSErRES Temperature Up Dimmer Down Dimmer Up Flame Speed Down Flame Speed Up
20. ther rights which vary from jurisdiction to jurisdiction The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty Dimplex North America Limited m 1367 Industrial Road Cambridge ON m ex Canada N1R 7G8 1 888 346 7539 e www dimplex com 2010 Dimplex North America Limited Approved for use in the United States and Canada Printed in China 22
21. tion 1 The power cord can be lead from behind the trim and along the wall to an outlet near the fireplace Option 2 A new outlet can be installed inside the new frame construction Plug the unit into a 15 Amp 120 Volt outlet If the cord does not reach you may use an extension cord rated for a minimum of 1875 Watts amp CAUTION Clearance for air circulation beneath the fireplace insert is provided by six 6 rubber feet Do not install the fireplace insert directly on carpet or similar surfaces which may restrict air circulation If installing the fireplace in a carpeted area place a one piece solid flat surface under the fireplace insert Ensure that all six of the insert s feet rest securely on this surface Operation Electric Fireplace Manual Controls The manual controls for the fireplace are located in the lower right hand corner Figure 3 Figure 3 A Main On Off Switch Supplies power to the Three Position Manual Control Switch 9 B www sylvane com 1 800 934 9194 Three Position Manual Control Switch Remote right position The unit is operated with the remote control Flame center position The flame effect is turned on Flame amp Heat left position The flame effect and heater are turned C on simultaneously When the manual control is in the Flame amp Heat position the heater does not run on the remote operated thermostat NOTE When the manual control swit
22. wide x 25 inches 648 mm high x 10 inches 267 mm deep The viewing area is 30 inches 765 mm wide and 20 inches 511 mm high The fireplace does not require any additional venting www sylvane com 1 800 934 9194 Fireplace Installation Install the fireplace assembly into the mantel refer to mantel assembly instructions NOTE 1 A15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the current rating of the circuit Figure 2 breaker IMPORTANT If pee not using a Dimplex mantel the fireplace must be installed in an 30 enclosure with the 775 mm following 11 4 MINIMUM 298 mm lt internal opening dimensions Figure 2 New Wall Construction 1 Select a suitable location that is not susceptible to moisture and is away from drapes furniture and high traffic Place the fireplace in the desired location to see how it will look in the room Mark the desired location on the floor and store the fireplace in a safe dry and dust free location Use studs to frame an opening of 30 inches 775 mm wide x 25 654 mm inches high x 11 inches 298 deep www sylvane com 1 800 934 9194 Op
23. www sylvane com 1 800 934 9194 X Dimplex Owner s Manual Model Numbers DF3015 Serial Number Model Number Part Number Valued Customer Thank you and congratulations for purchasing a Dimplex electric fireplace Over the years valuable memories will occur around the warmth and comfort of your fireplace Thank you for allowing our product to be the backdrop for those special moments 7207500100rev08 www sylvane com 1 800 934 9194 QUICK REFERENCE GUIDE 1 Prior to the first use of the fireplace verify the following e Are the circuit breakers for the socket the unit uses on e Are the light bulbs in your fireplace loose to check follow the instructions for replacing the light bulbs under the maintenance section of this manual 2 The heater on your fireplace may emit a slight harmless odor when first used This odor is a normal condition caused by the initial heating of internal heater parts 3 The information regarding the model of your fireplace can be found on the rating plate See page 6 for location 4 If you have any technical questions regarding the operation or service of your fireplace have your Model and Serial Number ready and contact Dimplex North America technical support at 1 888 DIMPLEX 1 888 346 7539 before returning the product to the point of purchase www sylvane com 1 800 934 9194 CONTENTS Important Instructions PAGE 4 Model and Ser