Home

Frequently Asked Questions

image

Contents

1. ASPIRE RE Frequently Asked Questions Where can I find the User Manual for the handheld tabletop controller RFHDCSG RFTDCSG You can access the User Manual for the handheld tabletop controller by clicking the link below User Manual What prevents 2 different Z Wave networks from interfering with each other Each Z Wave network has a unique Home ID that is held within the primary controller and assigned to all devices in the corresponding network How many devices nodes can be included in 1 Z Wave network A Z Wave network can hold a maximum of 232 devices nodes including the primary controller What is the maximum stated transmission range of a Z Wave device 60 feet with no obstructions however the more obstacles between devices the weaker the signal will be What is the frequency of the Z Wave signal 908 MHz Do all RF devices repeat the RF signal All devices repeat the RF signal except for the RF9500 battery operated switch and the handheld tabletop and scene controllers To control devices that are not directly in range of the controlling device Device 1 the signal can be carried by a maximum of 3 intermediate devices with the 5th device being the destination as shown below Device 1 gt Device 2 gt Device 3 gt Device 4 gt Device 5 COOPER Wiring Devices ASPIRE RE Frequently Asked Questions What is a scene A scene is a combination of lighting or appliance devices select
2. ect the Shift Primary option Then initiate the Replication Receive function from the secondary controller What is association An association is a feature that you can program to allow a device Source in your network to control another device destination The source device can only be a dimmer or switch For example an association is required to create a 3 way between 2 RF switches or dimmers In such a case 2 associations must be programmed the first would be from the Master to the Accessory the second from the Accessory to the Master If you are using a Z Wave controller from another manufacturer they may use another term for association What is the maximum number of devices that can be associated to 1 Aspire RF switch dimmer For each source device 5 associations can be programmed If you are using the HS2 for Aspire RF automation software 1 association is automatically created between the software and each device in the network therefore only 4 other associations can be programmed for each source device My controller does not support association How do I set up 3 ways and 4 ways In this case the only way to create a 3 way or 4 way is by using the traditional wired solution in which only the Master switch dimmer would be RF capable but the Accessory switches dimmers would be non RF and wired directly to the Master For dimming use RF9534 as the Master and RF9542 as the Accessory bot
3. ed by the user that can be controlled as a group by the wireless system Once you ve created your network you can program up to 64 scenes For example you can create a Movie scene that dims the overhead light and turns on accent lights What is an event An event is a scheduled one time or recurring program that launches a scene at a desired time You can program your controllers to create and control up to 32 events in your home For example if you plan on a romantic dinner you can schedule an event to automatically start a scene which dims the lights for the dinner How many scenes and events can be created using the Aspire RF handheld tabletop controller 64 scenes and 32 events can be created How many primary controllers can 1 Z Wave network have How many secondary controllers can 1 Z Wave network have Multiple What is the difference between primary and a secondary controller Only a primary controller can install include a device into a network However either type of controller can be used to uninstall exclude a device from the network COOPER Wiring Devices N ASPIRE RE Frequently Asked Questions Can a secondary controller become a primary controller 2 controllers can swap their status with each other via Replication allowing a secondary controller to become a primary controller and vice versa To do so initiate the Replication Send function from the primary controller and sel
4. h dimmers require a neutral wire For switch use RF9518 as the Master and RF9520 as the Accessory both switches require a neutral wire wo COOPER Wiring Devices ASPIRE RE Frequently Asked Questions What is the longest ramp time meaning slowest ramp rate that can be configured for an Aspire RF dimmer 4 minutes and 14 seconds 4 14 I need to replace a device that has stopped working Do I need to re program all my scenes and events that included that device No The Replace function in the Devices menu on the handheld tabletop controller will retain all information for that device and assign it to the newly installed replacement device If don t want to access my home network from outside the house do I need a RFBER or RFTCP RFBER or RFTCP are necessary to access the network from a tablet phone application from inside or outside the house over the internet Otherwise you do not specifically need an RFBER or RFTCP A handheld tabletop controller will be sufficient to create control the network from within the house Where can find the drivers for the RFUSB PRO The drivers are available on the RFUSB PRO product webpage Or you can click the link below Drivers 1925 0015 13 COOPER Wiring Devices

Download Pdf Manuals

image

Related Search

Related Contents

85 dB(A) - Oleo-Mac  User Manual - Team Total Solutions  Manuale Utente  Loops in Chain Manual  Un outil pour façonner la ville    442 Bedienungsanleitung und technische Information  Ponceuse Orbitale à Disque  HP 2009m Setup Poster  Hitachi CP-X450  

Copyright © All rights reserved.
Failed to retrieve file