Home
FCC DoC TEST REPORT
Contents
1. D indicates 8cm and 9cm dual fans or L indicates 12cm fan These models have identical electrical design and construction except that they are different in I O ratings From technical point of view we only took the worst case model ISO P500D for test The EUT is power switching device designed for the use to transform AC mains to DC power used by PC system For more detail information about EUT please refer to user manual Test method According to the major function design the EUT was installed on PC system inside enclosure for test The test was carried out on EUT operational condition and the worst case test result was recorded and provided in this report Conducted emission test The system was setup with the EMI diagnostic software running The power line conducted EMI tests were run on the line and neutral conductors of the power cord and the results were recorded The effect of varying the position of the interface cables has been investigated to find the worst case configuration that produces maximum emission At the frequencies where the peak values of the emission exceeded the quasi peak limit the emissions were also measured with the quasi peak detectors The average detector also measured the emission either A quasi peak values were under quasi peak limit but exceeded average limit or B peak values were under quasi peak limit but exceeded average limit Radiated emission test The maximum readings were found by
2. CONDUCTING GROUND PLANE EXTENDS AT LEAST 0 5m BEYOND EUT SYSTEM FOOTPRINT LEGEND 1 Interconnecting cables which hang closer than 40 cm to the ground plane shall be folded back and forth forming a bundle 30 to 40 cm long hanging approximately in the middle between ground plane and table 2 TO cables which are connected to a peripheral hall be bundled in center The end of the cable may b terminated if required using correct terminating impedance The total length shall not exceed 1 m 3 IfLISN are kept in the test setup for radiated emissions it is preferred that they be installed under the ground if requires receptacle flush with the ground plane Cables of hand operated devices such as keyboards KEYPADs etc have to be placed as close as possible to the controller Non EUT components of EUT system being tested The rear of all components of the system under test shall be located flush with the rear of the table No vertical conducting wall used Power cords drape to the floor and are routed over to receptacle 99 SON Page 13 of 31 PEP Testing Laboratory REPORT NO E930560 NVLAP LAB CODE 200097 0 8 3 Radiated Emission Limits Limits for radiated disturbance of Class A ITE at a measuring distance of 10m Frequency Field Strength MHz dB u V m 30 to 230 40 230 to 1000 47 NOTES interference occurs 1 The lower limit shall 2 Additional provisions re
3. EN55022 B QP LISN L 32A LINE eut E930560 power AC 120V 60Hz memo Peak Value ISO P500D Over Limit Read Probe Freq Level Limit Line Level Factor MHz dBuV dB dBuV dBuV dB 1 4 0 207 56 58 6 74 63 32 56 40 0 10 2 0 305 47 91 12 19 60 10 47 60 0 16 3 0 497 38 97 17 08 56 05 38 60 0 20 4 0 783 36 81 19 19 56 00 36 40 0 20 5 1 282 36 47 19 53 56 00 36 01 0 20 6 1 762 37 10 18 90 56 00 36 60 0 20 7 3 436 31 58 24 42 56 00 31 00 0 20 8 6 769 30 31 29 69 60 00 29 59 0 26 9 13 768 34 48 25 52 60 00 33 21 0 61 10 17 661 44 55 15 45 60 00 43 00 0 81 Page 17 of 31 NVLAP LAB CODE 200097 0 RENAL ARRAS PEP Testing Laboratory Data 333 File EN55022 B AV EMI Date 2004 10 07 Time 11 40 35 es MT 561562 os 1 2 5 16 26 Frequency Trace 332 Site Conduction No 2 Mick Linko site Condition EN55022 B AV LISN L 32A LINE eut E930560 power AC 120V 60Hz memo Average Value ISO P500D Page 1 Over Limit Read Probe Cable Freq Level Limit Line Level Factor Loss Remark 1 0 205 51 38 2 02 53 40 51 20 0 10 0 08 Page 18 of 31 NVLAP LAB CODE 200097 0 RANA ARRAS PEP Testing Laboratory Data 806 File EN55022 B QP EMI Date 2004 10 07 Time 11 42 41 so Prequency Trace 65 Site Conduction No 2 Mick Linko site Condition EN55022 B QP LISN N 32A NEUTRAL eut E930560 power AC 120V 60Hz memo Peak Value ISO P500D
4. SUPPORT EQUIPMENT USED DESCRIPTION OF CONDUCTED EMISSIONS TEST DESCRIPTION OF RADIATED EMISSIONS TEST CONDUCTED EMISSIONS TEST SETUP PHOTO CONDUCTED EMISSIONS TEST DATA RADIATED EMISSIONS TEST SETUP PHOTOS RADIATED EMISSIONS TEST DATA LIST OF MEASURED INSTRUMENTS DUTIES OF THE RESPONSIBLE PARTY LABELLING REQUIREMENTS INFORMATION TO THE USER EUT PHOTOGRAPHS 11 12 15 16 21 22 24 25 26 27 28 Page 2 of 31 PEP Testing Laboratory REPORT NO E930560 VLAD NVLAP LAB CODE 200097 0 1 Scope Conformity DoC Responsible Party Address Contact Person Phone No Regulation Limitation Test Procedure Test Item Model No Serial No Place of Test gt Measurement Uncertainty The uncertainty of the testing result is given as below The method of uncertainty Calculation is provided in PEP Testing Lab document No QP T 28 A amp QP T 27 A Measurement and determination of electromagnetic emissions EME of radio frequency devices including intentional and or unintentional radiators for compliance with the technical rules and regulations of the Federal Communications Commission under EUT Docket 95 19 Declaration of CHANNEL WELL TECHNOLOGY CO LTD 3F 2 888 Jing Rd Tao Yuan City Taiwan R O C Jacky Hsieh Engineer 886 3 3163111 Fax No 886 3 3 160455 FCC Part 15 amp Part 2 Docket 95 19 CISPR 22 CLASS B ANSI C63 4 1992 Switc
5. Page 1 Over Limit Read Probe Cable Freq Level Limit Line Level Factor Loss Remark MHz dBuV dB dBuV dBuV dB 1 0 157 54 72 10 88 65 60 54 60 0 10 0 02 2 0 208 53 98 9 29 63 27 53 80 0 10 0 08 3 0 302 45 85 14 34 60 19 45 60 0 10 0 15 4 0 595 38 34 17 66 56 00 38 00 0 14 0 20 5 0 974 37 23 18 77 56 00 36 79 0 20 0 24 6 1 858 37 30 18 70 56 00 36 80 0 20 0 30 7 6 698 29 51 30 49 60 00 28 79 0 26 0 46 8 11 933 35 11 24 89 60 00 34 20 0 30 0 61 9 17 661 43 89 16 11 60 00 42 79 0 36 0 74 10 22 775 32 54 27 46 60 00 31 40 0 34 0 80 Page 19 of 31 NVLAP LAB CODE 200097 0 PARAL ARRAS PEP Testing Laboratory Data 338 File EN55022 B AV EMI Date 2004 10 07 Time 11 44 53 es lt ede LA rade gt 43 4 4 ede ek e 4 gt gt 150 2 0 5 1 2 5 16 26 30 Prequency MH Trace 227 Site Conduction No 2 Mick Linko site Condition EN55022 B AV LISN N 32A NEUTRAL eut E930560 power AC 120V 60Hz memo Average Value ISO P500D Page 1 Over Limit Read Probe Cable Freq Level Limit Line Level Factor Loss Remark 1 0 207 44 38 8 94 53 32 44 20 0 10 0 08 Page 20 of 31 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 REPORT NO E930560 NVLAP LAB CODE 200097 0 11 Radiated Emissions Test Setup Photos l
6. angle High m 31 533 18 50 11 50 30 00 26 80 10 63 0 53 19 46 177 0 1 0 47 975 20 61 9 39 30 00 28 62 10 84 0 71 19 56 148 0 1 0 66 478 18 94 11 06 30 00 29 24 8 22 0 86 19 38 197 0 1 0 144 160 18 23 11 77 30 00 20 79 15 60 1 18 19 34 183 0 1 0 170 561 17 87 12 13 30 00 20 94 14 86 1 37 19 30 171 0 1 0 218 978 19 69 10 31 30 00 26 08 11 33 1 50 19 22 243 0 1 4 Note 1 Level Read Level Antenna Factor Cable Loss Preamp Factor 2 Over Limit Level Limit Line Page 23 of 31 PEP Testing Laboratory VLAD REPORT NO E930560 NVLAP LAB CODE 200097 0 13 List of Measured Instruments Test Mode Instrument Model No Serial No Next Cal Date Cal Interval Advantest Spectrum R3261A 91720076 Jun 09 2005 1Year R amp S LISN EUT ESH2 Z5 831886 004 Apr 06 2005 1Year Conduction No 2 Kyoritsu LISN 2nd KNW 242 8 837 7 N A N A RF Cable No 4 N A Feb 19 2005 1Year R amp S Receives ESBI 845658 003 Sep 07 2005 1Year Schaffner CPA 9232 1012 Aug 21 2005 1Year Pre Amp SCHWARZBECK Antenna 9161 9161 4051 May 06 2005 1Year COM Power AH 118 Radiation Horn Ant 1GHz 18GHz 10095 May 21 2005 1Year OP No 3 RF Cable No 2 N A Feb 19 2005 Year 970 971 Precision Dipole Jun 27 2006 3Year m 30MHz 1GHz 9534 954 R amp S Signal Generator SMYOI 829846 038 Feb 16 2005 2Year Page 24 of 31 PEP Testing La
7. 560 NVLAP LAB CODE 200097 0 Page 31 of 31 DECLARATION OF CONFORMITY CERTIFICATE Responsible Party CHANNEL WELL TECHNOLOGY CO LTD Address 3F 2 888 Jing Gwo Rd Tao Yuan City Taiwan R O C Contact Person Jacky Hsieh Engineer Equipment Switching Power Supply Model No ISO Pxxxy 250 300 350 400 450 500 S D or L ISO xxxy 200 230 250 300 350 400 450 500 y D L or blank Traceability FCC Part 15 amp Part 2 Docket 95 19 Limitation CISPR 22 CLASS B Date of issued NOV 09 2004 Report No E930560 The device bearing the trade name and model specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63 4 1992 See Test Report if any modifications were made for compliance PEP certifies that no party to this application has been denied the NVLAP benefits pursuant to Section 5301 of the Anti Drug Abuse Act of 1988 21 U S C 853 a PED IN 2 Kus WR 2 p 3 Peter Kao NVLAP Signatory NVLAP LAB CODE 200097 0 DECLARATION OF CONFORMITY This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interfere
8. C ID DZL211106 Manufacturer ACER Model Number M S42 Power Supply 5Vdc from PS2 of PC Power Cord N A Data Cable 1 gt Shielded Non detachable 1 8m 2 gt Back Shell Metal Page 10 of 31 PEP Testing Laboratory amp REPORT NO E930560 NVLAP LAB CODE 200097 0 7 Description of Conducted Emissions Test 7 1 Conducted Emissions x1 5m wooden table 80 cm high is placed 40cm away from the vertical wall Two AMN are bonded to the grounding plane The EUT is powered from the designated AMN and the support equipment is powered from another designated AMN Powers to the AMN are filtered by a high current high insertion loss power line filters All electrical cables are shielded by braided tinned copper zipper tubing with inner diameter of 1 2 All interconnecting cables more than 1 meter were shortened by non inductive bundling serpentine fashion to a 1 meter length Sufficient time for the EUT support equipment and test equipment was allowed in order for them to warm up to their normal operating condition The RF output of the AMN was connected to the spectrum analyzer to determine the frequency producing the maximum EME from the EUT The spectrum was scanned from 150kHz to 30 MHz with1 5 sec sweep time The frequency producing the maximum level was re examined using Quasi Peak adapter The detector function was set to CISPR quasi peak mode The bandwidth of the receiver was set to 10kHz The EUT
9. ORT NO E930560 NVLAP LAB CODE 200097 0 1 Personal Computer 2 Keyboard KBS1 PS 2 3 Monitor MONI 15 4 Printer PRN1 6 Support Equipment Used CPU Intel Xeon 2 4GHz FCC ID Declaration of Conformity DoC Manufacturer IWILL Model Number DPL533 Power Supply Switching Power Cord Non Shielded Detachable 1 8m Data Cable N A FCC ID E5XKB5121WTHO110 Manufacturer BTC Model Number 5121W Power Supply 5Vdc from PS2 of PC Power Cord N A Data Cable 1 gt Shielded Non detachable 1 6m 2 gt Back Shell Metal FCC ID Declaration of Conformity DoC Manufacturer SAMSUNG Model Number 550S Power Supply Switching Power Cord Non Shielded Detachable 1 8m Data Cable 1 gt Shielded Non detachable 1 5m 2 gt Back Shell Metal FCC ID Declaration of Conformity DoC Manufacturer Hewlett Packard Model Number C2642E Power Supply Linear 30Vdc O P Power Cable Non Shielded Detachable 1 7m Data Cable 1 gt Shielded Detachable 1m 2 gt Back Shell Metal Page 9 of 31 PEP Testing Laboratory REPORT NO E930560 NVLAP LAB CODE 200097 0 5 Modem MODI x 2 6 Mouse MOUS 1 PS 2 FCC ID IFAXDM1414 Manufacturer ACEEX Model Number 1414 Power Supply Linear 9Vac O P Power Cable Non Shielded Detachable 1 7m Data Cable 1 gt Shielded Detachable 1m 2 gt Back Shell Metal FC
10. PEP Testing Laboratory REPORT NO E930560 VLAD NVLAP LAB CODE 200097 0 Test Item Model No Responsible Party Address Test Engineer Test Date Issued Date 12 3Fl Taipei NVLAP Signature FCC DoC TEST REPORT According to FCC Part15 Subpart B Switching Power Supply ISO Pxxxy where xxx 250 300 350 400 450 500 y S D or L ISO xxxy where xxx 200 230 250 300 350 400 450 500 y D L or blank CHANNEL WELL TECHNOLOGY CO LTD 3F 2 888 Jing Gwo Rd Tao Yuan City Taiwan R O C STEVEN CHEN OCT 07 2004 NOV 09 2004 Peter Kao Peter Kao President The test report shall not be reproduced except in full without the written approval of the laboratory The report must not be used by the client to claim product endorsement by NVLAP or any agency of the United States government This report is only for item test which described in page 5 The testing result in this report are traceable to national and international standard PEP TESTING LABORATORY 27 1 Lane 169 Kang Ning St Hsi Chih Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 Page 1 of 31 PEP Testing Laboratory REPORT NO E930560 NVAO NVLAP LAB CODE 200097 0 10 11 12 13 14 15 16 17 Table of Contents SCOPE PRODUCT INFORMATION EUT DESCRIPTION AND TEST CONCLUSION MODIFICATION S TEST SOFTWARE USED
11. boratory REPORT NO E930560 NVLAP LAB CODE 200097 0 14 Duties of The Responsible Party The responsible party upon signing or accepting the Declaration of Conformity as specified in Section 2 906 of the FCC Rules hereby agrees to the duties listed below 2 1073 a The responsible party warrants that each unit of equipment marketed under DoC is identical to the unit tested and found acceptable with the standards and that the records maintained by the responsible party continue to reflect the equipment being produced is within the variation that can be expected due to quantity production and testing on a statistical bass 2 1073 b The responsible party must have a written statement from the manufacturer or accredited test laboratory that the equipment complies with the appropriate technical standards 2 1073 c In case of transfer of control of equipment as in the case of sale or merger the new responsible party shall bear the responsibility of continued compliance of the equipment 2 1073 d Equipment shall be retested if any modifications or changes are made that could adversely affect the emanation characteristics of the equipment 2 1073 e If any modifications or changes made by anyone other than the responsible party the party making the modifications of changes if located within the U S becomes the new responsible part The new responsible party must comply with all provisions for the DoC includi
12. hing Power Supply ISO Pxxxy ISO xxxy N A PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 Frequency MHz 0 15 30 30 1000 Expanded Uncertainty Ue 1 4 dB 2 8 dB X 95 Confidence Level 2 Page 3 of 31 PEP Testing Laboratory REPORT NO E930560 VLAD NVLAP LAB CODE 200097 0 EUT Name b Model No c Chassis Used d Port Connector s e Power Rating f Condition of the EUT g Test Item Receipt Date 2 Product Information Switching Power Supply ISO P500D Steel N A Switching Power Supply Model No ISO P500D Input AC 120V 9A 60Hz 420W Output DC 3 3V 5 12V1 12V2 12V 5Vsb 22A 32A 14A 15 0 5 2 0 Prototype Sample V Engineering Sample Production Sample OCT 07 2004 Page 4 of 31 PEP Testing Laboratory REPORT NO 930560 NVLAP LAB CODE 200097 0 3 EUT Description and Test Conclusion The equipment under test EUT is Switching Power Supply model ISO 500y ISO 450y ISO 400y ISO 350y ISO 300y ISO 250y ISO 230y ISO 200y where y D indicates 8cm and 9cm dual fans L indicates 12cm fan or being blank indicates 8cm single fan and ISO P500y ISO P450y ISO P400y ISO P350y ISO P300y and ISO P250y where y S indicates 8cm single fan
13. nce that may cause undesired operation Responsible Party CHANNEL WELL TECHNOLOGY CO LTD Address 3F 2 888 Jing Gwo RD Tao Yuan City Taiwan R O C Contact Person Jacky Hsieh Engineer Phone No 886 3 3163111 Fax No 886 3 3160455 Equipment i Switching Power Supply Model No ISO Pxxxy 250 300 350 400 450 500 SD or L ISO xxxy 200 230 250 300 350 400 450 500 y D L or blank We hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable FCC Rules under the most accurate measurement standards possible and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the Commission s requirements
14. ng having test data on file demonstrating that the product continues to comply with all of the applicable technical standards 2 1075 a 1 The responsible party shall maintain records of the original design drawings and specifications and all changes made to the product that may affect compliance 2 1075 a 2 The responsible party shall maintain records of the procedures used for production inspection and testing to insure the conformance with the FCC Rules 2 946 a 1 The test report data shall be provided to the FCC within 14 days of delivery of request The test sample s shall be provided within 60 days of delivery of request 2 946 b In case involving harmful interference or safety of life or property the production sample must be provided within 60 days but not less than 14 days Failure to comply with such a request with the time frame shown may be cause for forfeiture pursuant to Section 1 80 of Part 1 of the FCC Rules The Responsible Party is the manufacturer system integrator or the importer as defined in Section 2 909 of the FCC Rules The Rules The Responsible Party for a DoC must be located within the United States as specified in Section 2 1077 Page 25 of 31 PEP Testing Laboratory REPORT NO E930560 NVLAP LAB CODE 200097 0 15 Labelling Requirements The sample label shown below shall be permanently affixed at a conspicuous location on the device instructions manual o
15. quired for cases where transition frequency Limits for radiated disturbance of Class B ITE at a measuring distance of 10m Frequency Field Strength MHz dB u V m 30 to 230 30 230 to 1000 37 NOTES interference occurs 1 The lower limit shall 2 Additional provisions required for cases where transition frequency PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C IN V TEL 886 2 26922097 FAX 886 2 26956236 REPORT NO E930560 NVLAP LAB CODE 200097 0 9 Conducted Emissions Test Setup Photo lt FRONT VIEW gt Page 15 of 31 PEP Testing Laboratory REPORT NO 930560 NVLAP LAB CODE 200097 0 10 Conducted Emissions Test Data Model No ISO P500D Frequency range 150KHz to 30MHz Detector Peak Average Value Temperature 28 C Humidity 59 Yo Test Data 801 333 LINE 806 338 lt NEUTRAL gt Note 1 Level Read Level Probe LISN Factor Cable Loss 2 Over Limit Level Limit Line Margin Page 16 of 31 Data 801 File EN55022 B QP EMI UR ERAS USERS PEP Testing Laboratory NVLAP LAB CODE 200097 0 Date 2004 10 07 Time 11 39 25 Cable Loss Remark 20 30 Page 1 501502 05 1 2 Frequency MHJ Trace 606 Site Conduction No 2 Mick Linko site Condition
16. r pamphlet supplied to the user and be readily visible to the purchaser at the time of purchase However when the device is so small wherein placement of the label with specified statement is not practicable only the trade name model number and the FCC logo must be displayed on the device per Section 15 19 b 1 1 C Trade Name Model Number Page 26 of 31 PEP Testing Laboratory REPORT NO E930560 NVLAP LAB CODE 200097 0 16 Information To The User For a Class B digital device or peripheral the instructions furnished the user shall include the following or similar statement placed in a prominent location in the text of the manual Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfe
17. rence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Page 27 of 31 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 REPORT NO E930560 NIV UG NVLAP LAB CODE 200097 0 17 EUT Photographs Model No ISO P500D 93056 0 Page 28 of 31 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 REPORT NO E930560 NVLAP LAB CODE 200097 0 Page 29 of 31 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 REPORT NO E930560 NVLAP LAB CODE 200097 0 E ANN 7 amp u 29 x a tA A as 2 CF wa loc oon aV TRIB e Bwana saan s ef ate Page 30 of 31 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 REPORT NO E930
18. support equipment and interconnecting cables were re arranged and manipulated to maximize each EME emission Each emission was maximized by switching power lines varying the mode of operation or resolution clock or data exchange speed scrolling H pattern to the EUT and or support equipment and powering the monitor from the floor mounted outlet box and the computer aux AC outlet if applicable whichever determined the worst case emission 7 2 Conducted Emissions Limits Frequency Maximum RF Line Voltage dB uV Class A Class B MHz QUASI PEAK AVERAGE QUASI PEAK AVERAGE 0 15 0 50 79 66 66 56 56 46 0 50 5 0 73 60 56 46 5 0 30 73 60 60 50 Remarks In the above table the tighter limit applies at the band edges Page 11 of 31 PEP Testing Laboratory amp REPORT NO E930560 NVLAP LAB CODE 200097 0 8 Description of Radiated Emissions Test 8 1 Radiated Emissions Preliminary measurements were made indoors chamber at 3 meter using broadband antennas broadband amplifier and spectrum analyzer to determine the frequency producing the maximum EME Appropriate precaution was taken to ensure that all EME from the EUT were maximized and investigated The system configuration clock speed mode of operation or video resolution turntable azimuth with respect to the antenna were noted for each frequency found The spectrum was scanned from 30 to 1000 MHz using logbicon antenna Abo
19. t FRONT VIEW gt lt REAR VIEW gt Page 21 of 31 PEP Testing Laboratory REPORT NO E930560 NVLAP LAB CODE 200097 0 12 Radiated Emissions Test Data Model No ISO P500D Frequency range 30MHz to 1GHz Detector Quasi Peak Value Temperature 28 C Humidity 59 Antenna polarization HORIZONTAL Test distance _10m_ Over Limit Read Antenna Cable Preamp Freq Level Limit Line Level Factor Loss Factor Azimuth Antenna MHz dBuV m dB dBuV m dBuV dB dB dB angle High m 48 156 17 81 12 19 30 00 25 82 10 83 0 72 19 56 176 0 4 0 66 546 19 41 10 59 30 00 29 79 8 15 0 87 19 40 193 0 4 0 147 289 19 79 10 21 30 00 21 86 16 11 1 24 19 42 154 0 4 0 166 222 16 75 13 25 30 00 19 18 15 61 1 34 19 38 24 0 4 0 200 553 19 97 10 03 30 00 2648 11 49 1 50 19 50 199 0 4 0 219 000 18 66 11 34 30 00 25 05 11 33 1 50 19 22 215 0 3 8 Note 1 Level Read Level Antenna Factor Cable Loss Preamp Factor 2 Over Limit Level Limit Line Page 22 of 31 PEP Testing Laboratory NVAO REPORT NO E930560 NVLAP LAB CODE 200097 0 Model No ISO P500D Frequency range 30MHz to 1GHz Detector Quasi Peak Value Temperature 28 Humidity 59 Antenna polarization VERTICAL Test distance _10m_ Over Limit Read Antenna Cable Preamp Freq Level Limit Line Level Factor Loss Factor Azimuth Antenna MHz dBuV m dB dBuV m dBuV dB dB dB
20. varying the height of antenna and then rotating the turntable Both polarization of antenna horizontal and vertical are measured The effect of varying the position of the interface cables has been investigated to find the configuration that produces maximum emission The highest emissions were also analyzed in details by operating the spectrum analyzer in fixed tuned quasi peak mode to determine the precise amplitude of the emissions Page 5 of 31 PEP Testing Laboratory REPORT NO 930560 NVLAP LAB CODE 200097 0 ISO Pxxxy Series I O List Output rating dc Model I P rating ac ri P500y 115 230Vac S DorL 9 5A 60 50Hz 115 230Vac IS DorL 8 5 60 50Hz 115 230Vac y 8 DorL 7 4 60 50Hz low 5V optional sid pe 115 230Vac Page 6 of 31 PEP Testing Laboratory REPORT NO 930560 NVLAP LAB CODE 200097 0 ISO xxxy Series I O Rating List Output rating dc acd REI ISO 500y 115 230Vac 9 5A ISO 450y 115 230Vac 8 5A ISO 400y 115 230Vac 7 44 potash o e Page 7 of 31 PEP Testing Laboratory REPORT NO 930560 NVLAP LAB CODE 200097 0 4 Modification s N A 5 Test Software Used A EMITEST program that continuously generates a complete line of repeating letter was the software used during test Page 8 of 31 PEP Testing Laboratory REP
21. ve linearly polarized double ridge horn antenna was used Final measurements were made outdoors at 10 meter test range using logbicon antenna and horn antenna The test equipment was placed on a wooden bench situated on a 1 5x1 meter area adjacent to the measurement area Sufficient time for the EUT support equipment and test equipment was allowed in order for them to warm up to their normal operating condition Each frequency found during pre scan measurements was re examined and investigated using Quasi Peak Adapter The detector function was set to CISPR quasi peak mode and the bandwidth of the receiver was set to 120kHz The turntable containing the system was rotated the antenna height was varied 1 to 4 meters and stopped at the azimuth or height producing the maximum emission Each emission was maximized by varying mode of operation or resolution clock or data exchange speed scrolling H pattern to the EUT and or support equipment and powering the monitor from the floor mounted outlet box and the computer aux AC outlet if applicable and changing the polarity of the antenna whichever determined the worst case emission Photographs of the worst case emission can be seen in radiated emission test photo Page 12 of 31 PEP Testing Laboratory amp REPORT NO E930560 NVLAP LAB CODE 200097 0 8 2 Test Configuration EUT NONCONDUCTIVE 5 TABLE 1 5 x 1 METER 80 cm TO GROUND PLANE j V IN T cm