1. 28 use only attachments or tools rated for 200 PSI for working pressure or less CAUTION DO NOT PRESSURIZE YOUR TANK UNTIL YOU HAVE INSTALLED ALL NECESSARY PORT FITTINGS AND ACCESSORIES a Apply sealant to threads of fittings prior to assembly and hand tighten each part then use a wrench for an airtight connection b Do not over tighten if your port fittings are made from brass since brass threads can be stripped The fittings need to be only airtight c Always release air from tank before servicing or repairs d Wear safety glasses or goggles when operating this product WARNING DRAIN TANK AFTER EACH USE FAILURE TO DRAIN TANK AND REMOVE CONDENSATION WILL CAUSE TANK TO RUST PREMATURELY a To remove any accumulated condensation inside the tank bleed pressure from tank until pressure is approximately 5 PSI to 20 PSI b Drain water from tank by opening the drain cock valve c If drain cock valve is plugged release all air pressure from the tank Remove and clean the drain cock valve then reinstall d After water has been drained close the drain cock IMPORTANT Please observe air tank s Date of Manufacture stamped on tank leg Replace air tank 2 to 5 years from date air tank was first used or use the date of manufacture as reference Your adherence to air tank draining guidelines will determine the replacement date of your air tank RUSTED TANKS CAN FAIL CAUSING EXPLOSIONS OR FATAL INJURIES Discard tank immediately if ta
2. Your Vital Air Source 2 5 GALLON AIR TANKS PART NO 91025 VIAIR Your Vital Air Source PART NO 91028 IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 2 5 GALLON AIR TANKS Please read this instruction manual carefully prior to operating this product Pay particular attention to the CAUTION and WARNING statements in this manual Failure to comply with these instructions could result in personal injury or property damage Retain these instructions for future reference NOTE Your air tank comes with six 1 4 NPT port openings to allow installation in many configurations on your vehicle To insure safe and trouble free use of your air tank we strongly recommend that you install a drain cock and a safety pressure relief valve IMPORTANT a Tank P N 91025 is rated for 150 PSI maximum working pressure and Tank P N 91028 is rated for 200 PSI Do not over pressurize Overpressuring may result in death or serious injury b Tank is not to be used as a breathing device c Always wear ANSI approved safety glasses when operating air tank d Bleed pressure from tank after each use and before servicing or adding attachments e P N 91025 use only attachments or tools rated for 150 PSI for working pressure or less f P N 910
3. nk is rusted NOTE When using safety pressure relief valve point the safety pressure relief valve away from your body Use the pull ring on the safety relief valve to open the relief valve to vent any pressure inside the tank before attempting to service tank USER MANUAL 2 5 GALLON AIR TANKS 2 5 GALLON AIR TANK PARTS LIST B C A D E F G Sj e O E SB B P a A Vibration Isolators 6 pcs Brass Inserts 6 pcs Mounting Bolts M11 x 35mm 4 pcs Mounting Bolts M11 x 45mm 2 pcs Washers 4 pcs Locking Washers 4 pcs Hex Nuts 4 pcs QMMOOW LS See Fig 1 below for Mounting Hardware Assembly Fig 1 NOTE We have included 6 pcs of rubber bushings in your tank mounting hardware You have the option of using two layers of rubber bushings on one of your tank legs to slightly tilt tank toward drain hole to improve drainage when using a drain cock TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE S CORRECTIVE ACTION Tank loses air pressure 1 Air leaks from fittings 1 Locate leak by applying soap amp water solution Tighten fittings as needed Tank leaks 1 Pinhole from internal rusting 1 Replace tank immediately of tank Can t get air from tank 1 Low tank pressure 1 Tank pressure must exceed tire pressure Increase tank pressure USER MANUAL LIMITED WARRANTY VIAIR Corporation warrants this product when properly installed and under normal conditions of use to be free fr
4. om defects in workmanship and materials for a period of one year from its original date of purchase To receive warranty service or repair please contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE Your Vital Air Source 15 EDELMAN IRVINE CA 92618 TEL 949 585 0011 FAX 949 585 0188 www viaircorp com
Download Pdf Manuals
Related Search
Related Contents
Philips FWD132/98 User's Manual GrassMate User Manual User`s Manual Mode d`emploi Bougie LED en cire motif eur Folie 1 VS12-B200LA 電池格納部 取扱説明書(PDF、5MB) OM, GTV200, 1999-01 Bedienungsanleitung Alcatel E259 Samsung ME73BR Инструкция по использованию Copyright © All rights reserved.
Failed to retrieve file