1. Carefully rotate the pliers and apply pressure to each side of the connector pushing the top and bottom together IMPORTANT There is only one way to connect the 4 Way Power Splitter to the power supply and PS Link Connectors Make certain the icons match before connecting Connect the 4 Way Power Splitter to the PS Link Connectors and to the power supply BEFORE plugging the power supply into the AC outlet IMPORTANT There is only one way to connect the PS Link Connector to the power supply Make certain the icons match before connecting Connect the power supply to the PS Link Connector BEFORE plugging the power supply into the AC outlet A IMPORTANT Use Garden Stakes where CabLED strip will be installed on the ground outside Install so CabLED or connectors will NOT be submerged in water A IMPORTANT Do not coil the strip into a tight circle with a diameter less than 20cm 8 inches ELECTRICAL RATING To avoid any malfunctions of the system and to protect against electrical shock fire or physical injury please observe the following This system has been designed to work with 100 240 volt AC current Connection to a line voltage other than that may create a safety and fire hazard and may damage the system If you are unsure of the type of power supply to your home consult your local power company or a qualified service technician GROUNDING INSTRUCTIONS This product must be grounded If it should malfunction or breakdown grounding
2. 25M 49 2 82 Ft Connect to Power Matching the icons connect the PS Link Connector to the power supply Plug the power supply into the AC outlet A IMPORTANT Connect the power supply to the PS Link Connector BEFORE plugging the power supply into the AC outlet a A IMPORTANT The CabLED 8000 system is designed to work ONLY with the power supplies connectors mounting options and accessories listed Do NOT substitute other products as they may damage your system A IMPORTANT Do not plug into outlet until power supply is secured Place power supply near outlet and off the ground so there is no chance of it being submerged in water A IMPORTANT Risk of fire and electric shock Uncoil flexible CabLED light strip prior to plugging into receptacle A IMPORTANT The connectors consist of two parts a top and bottom which are partially assembled at the factory DO NOT push the connectors together before you are ready to install A IMPORTANT The CabLED strip may ONLY be cut every 18cm 7 09 inches indicated by a cut line on the LED side of the strip When you are measuring for your installation if the total length in inches is not a multiple of 7 then adjust the plan of your layout to use the nearest cut line marked on the strip IMPORTANT When using pliers that do not cover the entire surface of the connector hold the connector and strip steady so the CabLED strip remains in position
3. provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor is able to result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded Do not modify the plug provided with the product If it will not fit the outlet have a proper outlet installed by a qualified electrician Ground Fault Circuit Interrupter GFCI protection should be provided on the circuits or outlet to be used for the outdoor use flexible lighting product Receptacles are available with built in GFCI protection for this measure of safety If you are unsure of the type of outlet consult a qualified service technician to install a GFCI receptacle POWER SOURCE Do not modify the plug provided with the product If it will not fit the outlet have a proper outlet installed by a qualified electrician Damaged or deformed power cords are hazardous and should be replaced immediately by a qualified service technician OPERATION Do not operate with the flexible light tightly coiled Do not puncture cut shorten or splice the flexible lighting Unplug the
4. C bLED QPTILED CabLED Strip Dimension Cut CabLED Strip Install Connectors Cut CabLED strip to desired length along the cut mark indicated every 18cm 7inches A With the LED side facing up slide one CabLED strip into the opening in bottom half of one side of the connector until it reaches the end Repeat with the other CabLED strips in the other sides of the connector if required T i o E 5 a E x a a E o a 121 OI ol O ome Oo x k 1 s a PS Link C LC J Cabl p 180mm J Link Connector Connector umper Cable 5 5mm m Front view ao x a ai o x Side view Connectors L Connector T Connector U Connector CabLED Component Layout 4 Way Power Splitter Connects four CabLED strips to one power supply Install between power supply and four PS Link connectors This diagram illustrates possible layouts for the CabLED 8000 Series i Refer to the Component Overview for additional information PS Link Connector Used in ALL installations Connects CabLED strip to power supply l Connector Connects two lengths of CabLED strips in a straight line Use to extend a length of CabLED strip Jumper Cable Connects two CabLED strips with a 10cm 4inches 15 2cm 6inches 30 5cm 12inches 61cm 24inches 101 6cm 40 inches f
5. lexible cable AC Outlet L Connector Connects two CabLED strips at a right angle T Connector Connects three CabLED strips in a flexible T shape U Connector Connects two CabLED strips parallel to each other for twice the brightness or a balance of colour temperature l Connector Connectors X Connector Connects four CabLED strips at flexible angles End Cap Used in ALL installations Protects end of CabLED strip that is not connected to a connector L Connector T Connector U Connector U Connector CabLED Strip Specification Install 4 Way Power Splitter The CabLED strip uses CREE High Brightness LED lights set every inch and can be cut every 18cm 7inches A Match the icons on each PS Link Connector with the icons on the 4 Way Power Splitter Repeat the same connection method with the power supply and 3500K 6500K o o o o a fo Input Voltage 24V 5 ii e s e ChE a aa ea Power i o o o o i a Lifetime i 35 000h AN Install End Cap A Slide End Cap onto CabLED strip that will have no connector The End Cap protects the CabLED strip StorageTemperature 25 60 Max Connection Length 25m With 70 lumen maintenance Mounting Options Bridge Bracket Holds CabLED strip securely in place using two screw
6. om the AC outlet SERVICE Always remove the AC power adapter from the electrical outlet before adjusting or inspecting the system Inspect your system periodically Do not open dismantle or attempt to repair the CabLED strip or the bottom half of the connectors There are no user serviceable parts Do not open the cabinets of accessories or power supply There are no user serviceable parts Opening the cabinets may present a shock hazard and any modification to the product will void your warranty Do not attempt to service the components yourself If water or any metal objects such as paper clips wire or staples accidentally fall inside then disconnect from the power source immediately and consult an authorized service center b ce ee MKT 452 04 11 QPTILEyYD Email info optiled com Website www optiled com
7. s ol Channel Bracket It installs easily with one screw and is barely visible after CabLED strip is snapped into place Channeling CabLED strip snaps securely into channeling that runs the length of the installation Angle Channeling Angle Channeling fits into the corner of two surfaces and directs the light at a 30 degree angle You may install it so the light points up or down CabLED strip snaps securely into Angle Channeling that runs the length of the installation Edge Bracket Use for flush mount installations such as along a baseboard Suitable for use in high traffic areas Garden Stake Use for outdoor ground installations Holds the CabLED above ground so it will not be submerged in water and adjusts to direct the angle of light from 0 to 135 degrees May be used with Channeling Mark Placement for Brackets Install Channel Bracket Install Bridge Bracket A Install Angle Channeling A Double sided tap Ng Double sided tape 18 Watt 24VDC 30 Watt 24VDC 60 Watt 24VDC 100 Watt 24VDC Install Edge Bracket A B Adjust placement if necessary when tightening screws Install Garden Stake B Power Supply Select the correct power supply determine the length of CabLED strip needed Recommended Length of CabLED Strip Up to 4 5M 14 7 Ft 4 5 7 5M 14 7 24 6 Ft 7 5 15M 24 6 49 2 Ft 15
8. to prevent physical injury Products should be installed in accordance with the user manual current electrical codes and or the current National Electric Code NEC Improper installation may cause a possible shock or fire hazard To avoid electrical shock and or damage to the system do not handle the components with wet hands Always make sure the CabLED strip is disconnected from the power source before cutting connecting mounting or modifying in any way Do NOT dismantle the CabLED strip itself Do not coil the strip into a tight circle with a diameter less than 20cm 8 inches or bend it in half as it may damage the LEDs embedded in the CabLED strip Do not subject the flexible CabLED strip to continuous flexing Do not use if there is any damage to the light or cord insulation Inspect periodically CabLED connectors have sharp pins inside Follow instructions when handling Use only CabLED connectors mountings and power supply Carefully follow the instructions to install and mount Secure this flexible strip using only the hangers or clips provided Do not secure this product or its cord with staples nails or like means that may damage the insulation CLEANING Clean only with a dry or slightly damp cloth Do not use any acid or alkaline liquids cleansing agents or solvents Unplug the system from the wall outlet before cleaning NON USE PERIODS When left unused for long periods of time the system should be unplugged fr
9. unit and the AC power adapter from the electrical outlet during electrical storms or when unused for long periods of time to prevent damage For outdoor use units make sure that all connections and the end cap in the last segment are tightly secured to preclude the entry of water Do not exceed the recommended length of CabLED strip listed for each power supply Do not look directly into the LED lights when lit They are powerful and could damage your vision LOCATION Place power supply well above the ground or in an area they will NOT be submerged in water or other liquids The CabLED strip and components are rated IP65 weather proof only Do not submerge the flexible lighting in liquids or use the product in the vicinity of standing water or other liquids Keep all components away from extreme heat sources such as heating vents radiators electric heaters and fire pits Do not cover this product as the covering may cause the flexible light to overheat and melt or ignite Do not submerge the flexible light in liquids or use the product in the vicinity of standing water or other liquids Do not route the cord or flexible lighting through walls doors windows or any like part of the building structure Place CabLED strip so it will not shine directly into people s eyes INSTALLATION Safety measures must be observed at all times during the installation of this product Use proper safety gear and tools during the installation process
Download Pdf Manuals
Related Search
Related Contents
Canon PIXMA iP4500 Instruction Guide 1746-south-melbourne-market-roof-specs P - KIND Audio Affichette imprimable 取扱説明書 - 郵便ポスト専門店 ポストショップオンライン TCM 130 Step Code BA Software API User Manual V2 Manuel d`utilisation - Mitsubishi Electric American Standard Colony Soft 4275.551 User's Manual Bunn Speed Brew SBB Coffee Maker Copyright © All rights reserved.