Home

Batshop7Quickstart guide - HY-LINE

image

Contents

1. 604 231 7777 e Fax 1 604 231 7755 e Toll Free 1 800 565 5228 USA amp Canada only e E mail service cadex com e Mail Cadex Electronics Inc 22000 Fraserwood Way Richmond BC Canada V6W 1J6 Attn Service Cadex and the Cadex logo are trademarks of Cadex Electronics Inc 2002 Cadex Electronics Inc All rights reserved N Made and printed in Canada 22000 Fraserwood Way Richmond BC Canada V6W 1J6 N Tel 1 604 231 7777 pn Fax 1 604 231 7755 oO E mail Info cadex com pu N 3 gt D 33 Cadex Batteryshop QuickStart Guide This booklet provides basic information and instructions for installing setting up and using Cadex Batteryshop including e Installing Cadex Batteryshop e Preparing battery analyzers for Cadex Batteryshop Setting up other devices e Starting Cadex Batteryshop e Setting up Cadex Batteryshop e Servicing batteries e Product and technical support Note Comprehensive documentation for Cadex Batteryshop can be found in the On line Help file with Batteryshop running Press F1 Minimum system requirements e AC72 C74 C74ER C Series firmware 1 1 or better or C72 C74 C74ER firmware 6 12 or better or the C7000 battery analyzer firmware 3 53 or better Contact Cadex for the C7000 firmware upgrade kit e Dedicated computer with Windows XP 2000 Professional 32 bit e 1000 MHz or better CPU 160 MB free hard drive space 256 MB RAM with one analyzer 512 MB RAM wit
2. Cadex Batteryshop QuickStart Guide Basic Battery Service Procedures continued 3 Under Analyzers click Analyze Battery to display the Analyze Battery Battery Information dialog box 4 Click By Model or By Battery ID 5 Enter the battery model number or battery ID you want to service e In the database grid area find and double click the record for the battery model number or battery ID you want to service OR e Type the model or battery ID number in the appropriate text box OR e Click Browse to search for the required battery information The status bar at the bottom displays Ready to accept batteries once you enter a valid model or battery ID number 6 lf you are servicing batteries by Battery Model e Enter the customer jo 2 coe name to include it in the service record You can also click Browse to select the customer from the database e Under Analyze Mode choose Single to service one battery or Batch to service several batteries of the same model 7 To print a battery service report and label when service is completed select check Auto Print Service Report and Auto Print Service Label 8 Set the target capacity and select the program to run See the Cadex Batteryshop Online Help or the analyzer User s Manual for details about programs Tange Cages FS 9 Insert the battery to start servicing If you are servicing more than one battery of the same model insert the next battery w
3. ENTER to select choose SYSTEM SETUP then OUTPUT DEVICES then SERIAL PORT DEVICE and finally BATSHOP 3 Press ENTER to confirm then press ESC twice Starting Cadex Batteryshop e Double click the Cadex Batteryshop icon on the desktop OR e Click Start on the Windows Task Bar point to Programs then point to Batteryshop and then click Cadex Batteryshop Setting up Cadex BatteryShop The first time you start Cadex BatteryShop the Setup Wizard opens automatically Follow the on screen prompts to set up these items e Enter site information You must enter the serial number on the back of the Cadex Batteryshop CD case and the name and phone number of your work site before setup will continue e Specify serial COM ports to which Cadex battery analyzers are connected via RS 232 interface Do not include ports connected to any other device or USB COM Ports to which C Series analyzers are connected e Format service reports and Battery ID and service labels e Set the default service due period for battery services e Setreporting and security options These settings can be changed in System Setup See the Cadex Batteryshop Online Help for more information Cable Connections BatteryShop comes with USB cable s to connect the analyzer to the PC The Analyzer comes with a null modem RS 232 cable to connect the analyzer to the PC Use the USB cable or the RS 232 cable but not both to connect the analyzer to the PC www cadex c
4. h more than one analyzer e Color monitor 16 bit 1024 x 768 resolution mouse keyboard e UPS uninterruptible power supply and 2 Gb free hard drive space if you want to collect Real time data e USB port or RS 232 port for each battery analyzer USB2 Hub for multiple CSeries battery analyzers USB COM port multiport adapter for C72 C74 C74ER C7000 battery analyzers Cadex Batteryshop QuickStart Guide Setting up other devices Before you start Cadex BatteryShop for the first time you must set up your label and standard Windows printers for printing labels and reports For C Series battery analyzers you will need to install a C74xx USB COM Port Driver found on the BatteryShop CD and you may need a USB2 hub for multiple C Series battery analyzers Instructions for installing DYMO label printer drivers and USB support are in the Cadex BatteryShop PDF Manual found on the BatteryShop CD Note You must install printer drivers for standard report and label printers for correct operation of Cadex BatteryShop The standard printer should be set as the default Windows printer Windows comes with a large selection of drivers for standard printers Follow Dymo LabelWriter setup instructions and BatteryShop PDF Manual for more information on the setup of the Dymo LabelWriter 400 Printer The recommended label size for the Dymo LabelWriter is 30334 2 1 4 in x 1 1 4 in Installing Cadex Batteryshop 1 Insert the Cadex Batterys
5. hen the Service started message appears 10 Repeat steps 4 through 9 to set up another battery service 11 Click Done when you have no more batteries to service 12 You can also service a battery by selecting a favorite battery model or battery ID or by entering battery parameters directly See the Cadex Batteryshop Online Help for details Product and Technical Support Online Helo and PDF Manual Cadex Batteryshop Online Help and PDF Manual contains information on features and step by step instructions to help you get the most out of your battery maintenance software Under Help click Help to open Cadex BatteryShop online Help or Press F1 Web Resources The Cadex Web site provides extensive support for Cadex Batteryshop Visit our Web site at www cadex com for the following e Frequently Asked Questions e Articles and technical papers e Updates to the battery models database including Quicktest matrices e Downloadable Custom Programs e Updates to Batteryshop s online Help and QuickStart Guide e Downloadable firmware updates for Cadex 7200 and Cadex 7400 battery analyzers e Technical support papers www cadex com Technical Support If you have a technical problem with Cadex Batteryshop or the Cadex battery analyzers you can contact our Technical Support department by phone fax e mail or mail The Technical Support phone lines are open 8 00 AM to 4 30 PM Pacific Time Monday through Friday e Phone 1
6. hop CD in your CD ROM drive 2 Click Start on your Windows task bar and then click Run 3 Inthe dialog box that appears type n setup exe where n is the drive letter for your CD ROM drive For example if your CD ROM drive is drive D you would type d setup exe 4 Follow the prompts on the screen e f the setup program finds a previous version click Yes to upgrade The setup program backs up your existing database and then copies the data to the new database after it installs Cadex Batteryshop e The default installation location is C Program Files Batshop but you can specify another drive and or folder e If the setup program prompts you to update system files choose Yes and allow the system to reboot The setup program restarts automatically allowing you to complete the installation If it does not restart automatically repeat steps 2 and 3 If you have any problem installing Cadex Batteryshop see the ReadMe txt file on the Cadex Batteryshop CD Preparing battery analyzers for Cadex Batteryshop Preparing C72 C74 C74ER C Series C72 C74 C74ER or C7000 analyzers 1 From the global display press MENU 2 Using Aor VY to scroll through options and ENTER to select choose SYSTEM SETUP then SERIAL PORT DEVICE and finally BATTERYSHOP 3 Press ENTER to confirm then press ESC twice Preparing C7000 and C7000 ER analyzers 1 From the global display press MENU 2 Using 1 or S2 to scroll through options and
7. om Connect one end of the USB cable to the analyzer and the other end to the PC If you power ON the analyzer with the USB cable connected the PC will detect the new USB device and prompt for USB Driver install files only if the driver was not previously installed Browse to the USB folder on the BatteryShop CD to install the required drivers and walk through the remaining screen prompts on the PC Servicing batteries 1 Turn on the analyzer s and start Cadex Batteryshop Do not insert any batteries yet although you can insert the battery adapters 2 Under Analyzers click Connect Cadex Batteryshop starts communicating with analyzers connected to the mapped COM ports The main window displays an icon for each connected analyzer that is turned on The top half of the icon shows number of the COM port to which the analyzer is connected followed by a dash and the first two digits of the analyzer model name The bars in the bottom half of the icon represent the analyzer s battery service stations The color of the bar indicates the station s status ese win wow non hat