1. To enable or disable the chime feature 1 Scroll until the display shows Chime and then press Enter The current setting will flash 2 Scroll to toggle the chime feature on or off and then press Enter The setting will stop flashing 3 Press Status to exit A solid bell icon will appear in the display when the chime feature is enabled Special chime The special chime feature allows you to install motion sensors in a patio or at the front door and be notified when someone is approaching those areas These motion sensors are not used for intrusion protection The panel will chime three times if the special chime mode is enabled Note If there are no special chime sensors in your system the special chime option will not appear in the menu To enable or disable the special chime feature 1 Scroll until the display shows Special Chime and then press Enter The current setting will flash 2 Scroll to toggle the special chime feature on or off and then press Enter The setting will stop flashing 3 Press Status to exit An outlined bell icon will appear in the display when the special chime feature is enabled Note This menu option will not appear if special chime sensors are not in your system FCC compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against
2. Press Motions 2 Enter your code when the display shows Enter Code if a code is required The display shows Motions speaks Motions On and the Motions button lights The panel starts an exit delay and sounds exit beeps in groups of three until the exit delay expires To arm doors windows and motion sensors level 4 1 Press Doors Windows 2 Enter your code when the display shows Enter Code if a code is required 3 While the panel is in the process of arming press Motions The display shows Doors Windows amp Mot ions speaks Doors and Windows On Motions On and the Doors Windows and Motions buttons light up The panel starts an exit delay and sounds exit beeps in groups of four until the exit delay expires Silent exit Press Silent after you arm the system to silence status beeps The silent exit feature silences the status beeps that accompany the exit delay The panel will still beep at the beginning and end of the exit delay Note Enabling silent exit doubles the exit delay time Alarms The system provides a series of alarms that indicate an unusual occurrence When an alarm is active the display shows Alarm Alarm Alarm Press Status To cancel the alarm enter a valid master or user code After alarms are canceled the system will be disarmed System status Press Status no code is required to cause the system to display and speak the following types of information e Alarm condi
3. harmful interference when the equipment is operated in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment In accordance with FCC requirements of human exposure to radio frequency fields the radiating element shall be installed such that a minimum separation distance of 20 cm is maintained from the general population FCC ID B4Z 801 IXT2 This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada IC 1175C 8011
4. GE Security Simon XT TableTop Quick Operation Guide Content Contact information 1 Operation 1 Arming and disarming 2 Alarms 2 System status 2 Touchpads and key fobs 3 Status beeps 3 Alarm sirens 3 Panel indicator lights 3 Trouble beeps 3 Programming 4 Contact information For contact information see our Web site www gesecurity com Operation Use this document to quickly begin operating your Simon XT TableTop security system model 600 1054 95R ITT Refer to your Simon XT TableTop User Manual for full operating details and programming options Note The default master code is 1 2 3 4 when the security system is shipped from the factory You should change your code after your system is installed To operate the security system e Use the front panel buttons to arm disarm the system when you enter or exit your home and to determine which sensors are active and the system status e Use the three fast action keys to communicate with the central monitoring station to report police fire or emergency alarms e Use a combination of the panel buttons and the display menu to program certain user features This method is used by your installer to establish your system configuration Refer to your Simon XT TableTop User Manual Table 1 below describes the panel keys and features Table 1 Panel keys and features Control Description Piezo siren Provides alarm beeps and status beeps LCD display Pro
5. XT2 This device has been designed to operate with the antenna indicated below and having a maximum gain of 2 dB Antennas having a gain greater than 2 dB are strictly prohibited for use with this device The required antenna impedance is 50 ohms Taoglas TG 09 0113 Antenna is supplied with the system Simon XT TableTop Quick Operation Guide
6. ble 2 below describes the arming levels that you can set from the control panel Table 2 Arming levels Level Function Description 0 Subdisarm If your system includes 24 hour protection sensors you must subdisarm the panel before accessing these areas to avoid causing an alarm Environmental sensors such as smoke or carbon monoxide detectors stay active at all times 1 Disarm In this level only 24 hour sensors are active 2 Arm door and This level arms the door and window window sensors sensors while leaving the interior exterior motion sensors disarmed 3 Arm motion sensors This level arms the interior motion interior sensors while leaving the exterior door and window sensors disarmed 4 Arm doors windows _ This level arms all sensors and motion sensors To disarm level 1 1 Press Disarm 2 Enter your code when the displays shows Enter Code The panel displays and speaks Disarmed the Disarm button lights up and the panel beeps once To arm doors and windows level 2 1 Ensure that all doors and windows are closed 2 Press Doors Windows 3 Enter your code when the displays shows Enter Code if a code is required The panel displays Doors Windows speaks Doors and Windows On and the Doors Windows button lights up The panel starts an exit delay and sounds exit beeps in groups of two until the exit delay expires To arm motion sensors level 3 1
7. m is able to automatically test itself for e Power failures e Low batteries e Nonworking sensors e Communication trouble with the central monitoring station When your system detects one of the problems above six rapid beeps sound every minute until the trouble condition is corrected To stop the trouble beeps press Status or arm and then disarm the system while the trouble condition exists Trouble beeps will resume 4 hours later unless the trouble condition is corrected Refer to your Simon XT TableTop User Manual for details Programming Your Simon XT TableTop security system allows you to program certain user options such as access codes time schedules or the system time Refer to your Simon XT TableTop User Manual for programming options and details Chimes Use the chime feature to signal when a protected door is opened while the system is disarmed The panel chimes twice when a chime sensor is tripped if the chime mode is enabled This feature allows you to be notified when family members are going in and out of your home The chime and special chime features are turned on or off in the System menu Note If there are no chime sensors in your system the chime option will not appear in the System menu Your installer may have programmed the system to speak the sensor name or make a custom chime sound when a chime sensor is tripped The chime sound if programmed will be played in place of the standard chime beeps
8. stop beeps for 4 hours No activity beeps Twenty beeps every minute for 5 minutes feature must be programmed by the installer Alarm sirens Exterior and interior sirens make three different alarm sounds on the premises each indicating a different type of alarm Sirens are programmed by the installer to time out and stop sounding after a specified time Table 4 below describes the siren sounds used by the security system Simon XT TableTop Quick Operation Guide Table 4 Siren sounds Function Fire Intrusion Emergency Interior and Temporal 3 Steady Fast on off panel siren Exterior siren Temporal 3 Steady Note Temporal 3 refers to a continuous pattern of three siren pulses then off for 1 5 seconds three siren pulses then off for 1 5 seconds Panel indicator lights Table 5 below describes the front panel indicator lights Table 5 Indicator light Button When button light is on When button flashes Doors Windows Doors and windows armed Doors and windows armed and no entry delay on otions Motions armed Motion sensors armed and latchkey on Disarm System disarmed System subdisarmed Status System trouble open System in alarm sensor or bypassed sensor Enter There are no open sensors Chime solid bell Door will cause chime Special chime Motion will cause chime outlined bell Latchkey on key Latchkey feature on Trouble beeps Your security syste
9. tions e Alarm history e Trouble conditions Simon XT TableTop Quick Operation Guide e Open sensors e Bypassed sensors The Status button blinks when an active alarm exists The Status button is lit when an abnormal condition such as a trouble or open sensor exists in the system You can clear certain status entries from the system such as old alarm history by pressing Disarm after checking the status Touchpads and key fobs You can use touchpads and key fobs to control the security system from remote locations in and near your home Interfacing with the system using a touchpad is similar to using the panel Refer to the Simon XT TableTop User Manual and the touchpad or key fob documentation for details Status beeps The panel sounds status beeps to alert you to various system events and conditions as shown in Table 3 below Table 3 Status beeps Activity Beep response Doors Windows Exit delay and entry delay beeps sound two times every 5 seconds and two times per second during he last 10 seconds otions Exit delay and entry delay beeps sound three times every 5 seconds and three times per second during he last 10 seconds Doors Windows Exit delay and entry delay beeps sound four times and Motions every 5 seconds and four times per second during he last 10 seconds Disarm One beep Chime Two beeps Special chime Three beeps Trouble beeps Six beeps every minute Press Status to
10. vides a 2 x 16 character array that displays a Doors Windows otions Disarm Status Silent Bypass Emergency cross Police star Fire flame Microphone Scroll up scroll down arrows 2010 GE Security Inc variety of phrases and icons Press to arm perimeter sensors Press to arm interior sensors Press to turn off intrusion burglary protection for your system Only intrusion burglary sensors are disarmed Environmental sensors such as smoke and carbon monoxide detectors stay active at all times Press to determine system status Press to silence exit beeps when arming Press to bypass a sensor Press and hold for 2 seconds or press twice quickly to call the central monitoring station and notify them of a nonmedical call for help Use to communicate with the central monitoring station after an alarm Press to scroll through lists of similar items P N 466 2388 e REV A ISS 18MAY10 Control Description Enter Press to select a particular menu item or commit to panel memory a menu item that has just been programmed Numeric keypad Press the keys 0 to 9 and to enter access codes or other numerical data Press to turn lights on Press to turn lights off Speaker Provides voice output and sound key beeps While the panel is idle the text displays Display line 1 Arming level Display line 2 HH MM x Time and status icons Arming and disarming Ta

Download Pdf Manuals

image

Related Search

Related Contents

Samsung WA10F3VFC/XTC คู่มือการใช้งาน  American Dryer Corp. ADG-531HS User's Manual  PAINEL DE COMANDO MANUAL DE INSTALAÇÃO  Smartphone  30 ET 31 DEC 08 - Jared Gradinger  Quantum LTO-3HH  Pour des espaces ouverts et diversifiés  SWAT-24X Manual - Earthquake Sound  Comment s`inscrire sur le guichet virtuel  Leame Primero 3  