1. 31 User Manual Managed Meda Converter Chassis System If press the default for configuration of all MC all configuration will be reset to factory default until it shows Done lt NOTE gt Note the N A indicate Not Applicable 9 Update Firmware You can update the firmware of your system Normally this is done when a new version of firmware is released 32 User Manual Managed Meda Converter Chassis System Appendix A Connector Pinouts Port Connector The following table lists the pinout of the Ethernet Switch s 10 100Base TX ports For 10 100Base Pin1 3 Trans Receive Data For 10 100Base Pin2 6 Trans Receive Data 100BASE FX 100Mbp Ethemet implementation over fiber 100BASE TX 100Mbps Ethemet implementation over Category 5 and Type 1 Twisted Pair cabling 10BASE T The IEEE 802 3 specification for Ethemet over Unshielded Twisted Pair UTP cabling auto negotiation A feature on a port that allows it to advertise its capabilities for speed duplex and flow control When connected to an end station that also supports auto negotiation the link can self detect its optimum operating setup stack A group of network devices that are integrated to form a single logical device TFTP Trivial File Transfer Protocol Allows you to transfer files such as software upgrades from a remote device using your switch s local management capabilities 33 User
2. Receive Count Drop Count and Collision Count Media Port2 Type Current Model Link Status Receive Count Drop Count and Collision Count lt NOTE gt If the Status needs to be calculated from fresh please press the Reset botton to restart the counting lt NOTE gt This menu can also be read simply point the Left hand side of Managed Converter Chassis on the top graphic of Chassis 0 where the Chassis Hardware Switch is 3 3 CO MC Control Chassis gt Chassis 0 3 gt MC 1 8 gt COMC Control 16 User Manual MC Options Forwarding Mode Store Forward or Cut Through or Repeater or Auto Change Remote Control Disable or Enable Link Fault Pass Through Disable or Enable Media Port Type Current Model Port Mode Auto or 10HD or 10FD or 100HD er 100FD Flow Control Disable or Enable MDIX Disable or Enable Output Rate Full or 25 or 50 or 75 Input Rate Full or 25 or 50 or 75 Media Port2 Type Current Model Port Mode 100HD or 100FD Flow Control Disable or Enable Informing Way for Receiving Off Maintenance Frame or Far End Fault Pattern NOTE gt After configuration set need to press the Apply and Save buttons t
3. as CO side 6 Media Converter Terminal as CPE side 8 8 Slot Managed Converter Chassis 9 System Configuration 11 Connecting to Power 11 Chassis Stacking 11 Web Based Browser Interface 12 Logging on to The Managed Media Converter Chassis System 12 Main Menu 12 1 System Change 13 2 IP Configuration 14 3 Chassis 14 4 Monitor 22 5 SNMP Configuration 26 6 Alarm 27 7 Save 29 8 Default 31 9 Update Firmware 32 Appendix A Connector Pinouts 33 2 UserManual Managed Media Converter Chassis System Chapter Overview Technical Specifications This chapter contains the following models 1 Chassis Manager 2 Media Converter MC as CO side 3 Media Converter Terminal as CPE side 4 8 Slot Managed Converter Chassis System Configuration This chapter provides network managers and system administrators with information about how to configure the Managed Media Converter Chassis System via the Web Browser The reader of this document should be knowledgeable about network devices device configuration network management and Intemet browers The user is assumed to be network administrator or manager with an understanding of network operations Application and Connector Pinouts See Appendix A for more information 3 User Manual Managed Meda Converter Chassis System Technical Specification Chassis Manager Key Features e One channel media conversion between 10 100Base TX and 100Base FX e Support AUTO Negotiation and AU
4. 2 3 Netmask To set the Netmask the default is 255 255 255 0 24 Default Gateway To set the default Gateway address is 192 168 1 254 lt NOTE gt After configuration set need to press the Apply button to save the setting 3 Chassis 3 1 Chassis Hardware Monitor This section divide to 4 different Managed Converter Chassis with No on each Chassis unit 14 User Manual Managed Meda Converter Chassis System Chassis gt Chassis 0 3 gt Chassis HW Monitor i e e11 1 CD pat LITE Bee ee This section you can see the Chassis 0 3 Hardware Monitor Temperature Supply Voltage Value 12 Volts Suggest the normal condition 12 Volts 10 Fan Status There are 2 Fans in Chassis Status On or Off Active MC There are 8 slots for Media Converter or Chassis Manager Status Active or Inactive Uptime lt NOTE gt This menu can also be read simply point the Left hand side of Managed Converter Chassis on the top graphic of Chassis 0 3 where the Chassis Hardware Switch is 3 2 CO MC Status This section you can see the Media Converter 1 8 inside of Chassis 0 3 Chassis gt Chassis 0 3 gt MC 1 8 gt COMC Status 15 User Manual Operation Status Normal or Local loop test or Far end fault or Hardware fault or Software fault Media Port 1 Type Current Model Link Status
5. Limit C Suggest set on 45 C Fan Operation Time Limit Hours 1000 Hours or more 6 3 Alarm Mail Trap 28 User Manual Managed Media Converter Chassis System If you check the enable Alarm by SMTP system will send alarm information to the configured email address through the configured mail server 6 4 Alarm SNMP Trap SNMP enables network administrators to manage network performance find and solve network problems When SNMP Trap events are ON the device can send out trap messages automatically to the trap manager if configured 7 Save 7 1 Configuration of Chassis Manager 29 User Manual If press OK for the Are you sure column all changed configuration for Chassis Manager will be saved And Cancel will be no save 7 2 Configuration of all MC GU SU See EE CET Le ITI Ce RER CH Las Le Lea CH If press the save for configuration of all MC all previous changes of configuration will be starting to save until it shows Done lt NOTE gt Note the NA indicate Not Applicable 30 User Manual Managed Meda Converter Chassis System 8 Default 8 1 Configuration of Chassis Manager If press OK for the Are you sure column all configuration for Chassis Manager will be reset to factory default And all configuration for Chassis Manager will not be reset to factory default if Cancel will be pressed 8 2 Configuration of all MC
6. Terminal MC Auto Report for all Media Converter installed in the Chassis 23 User Manual Managed Meda Converter Chassis System 4 3 Total CPE MC Status Monitor gt Chassis 0 3 gt Total CPE MC Status This section you can see the Terminal MC Status for all Media Converter installed in the Chassis 4 4 Total Loopback Test Monitor gt Chassis 0 3 gt Total Loopback Test 24 User Manual This section you can see the Loopback Test Status for all Media Converter installed in the Chassis 4 5 Total MC Hardware Status Monitor gt Chassis 0 3 gt Total MC Hardware Status CN Seer eet eee mg SE er mg er mer See L b Ji llis J This section you can see the MC Hardware Status for all Media Converter installed in the Chassis 25 User Manual Managed Media Converter Chassis System 4 6 Chassis Monitor This section you can monitor all the 0 3 Managed Converter Chassis status 5 SNMP Configuration 26 User Manual Managed Meda Converter Chassis System System Contact Contact information for the system administrator responsible for managing system System Location Description of where your system is physically located Get Community public private Set Community public private 6 Alarm 6 1 Alarm Configuration Allows a network administrator to define alarm events 6 2 HW Alarm Configuration 27 User Manual Low Power Limit 0 100 96 High Temperature
7. browser IE explorer Netscape Communication etc to open up the Managed Converter Chassis monitering System Logging on to The Managed Media Converter Chassis System The default IP Address for the System is 192 168 1 10 and there is no need to type in both Login name and password as default just simply press OK to start the Main Screen 12 User Manual Managed Meda Converter Chassis System 1 System Change There are five items in the System Change menu Device Name New Password Old Password Version and Mac Address 1 1 Device Name This section is to set your own Device Name 1 2 New Password This section is to set your own New Password 1 3 Old Password This section is to verify the old password you set before 14 Version This is an indication of the Software version for reference 1 5 Mac Address This is the information of Mac Address of your Device lt NOTE gt After configuring the Device need to press the Apply botton to save the setting 13 User Manual Managed Media Converter Chassis System 2 IP Configuration There are 4 items in the IP Configuration DHCP IP Address Netmask and Default Gateway 2 1 DHCP To set the DHCP Enable or Disable 2 2 IP Address To allocate an IP Address for the Managed Converter Chassis the default IP is 192 168 1 10
8. 0m 328ft 100Base FX 50 or 62 5 125um Multimode fiber optic cable 9 or 10 125um Single mode fiber optic cable Switching Method Store and Forward Forwarding Rate 14 880pps for 10Mbps 148 81 Opps for 100Mbps Power Consumption 3W Max 8 User Manual Managed Meda Converter Chassis System Physical Specification Power 0 25A 12VDC Power Supply Operating Temperature C 45 C 32F 113 F Storage Temperature 10 C 70 C 14 F 158 F Humidity 5 95 non condensing Emission amp Compliance CE Mark Class A FCC Part 15 Class A Dimensions 80mm W x 124mm D x 20mm H 8 15 W x 4 88 D x 0 79 H Net Weight 160g 0 35lb 8 Slot Managed Converter Chassis Key Features Each Chassis Houses 8 Slots Converters e Slim 1U Height 19 Design to Save Space e Stackable up to Four Chassis up to 32 Converters e Hot Swappable Supports Power Redundancy Technical Specifications LED PWR1 For AC Power status PWR2 For DC Power status Fan 1 Fan 2 For Fan status STK IN STK OUT For stack port status Stacking Port RJ 45 Stacking Cable Cat 5 with Max Length of 1 Meter Terminal Block For Redundant Power 2 67A 12VDC 9 User Manual Managed Meda Converter Chassis System Environmental Specifications Power AC Input 100 240V DC Input 2 67A 12VDC Operating Temperature C 45 C 32F 113 F Storage Temperature 10 C 70 C 14 F 158 F Humidity 5 95 non condensing Emission a
9. 10Mbps 148 81 0pps for 100Mbps Power Consumption 4 2W Max Physical ification Power 0 35A 12VDC Power Supply Operating Temperature C 45 C 32 F 113 F Storage Temperature 10 C 70 C 14 F 158 F Humidity 5 95 non condensing Emission amp Compliance CE Mark Class A FCC Part 15 Class A Dimensions 80mm W x 124mm D x 20mm H 3 15 W x 488 D x 079 H Net Weight 160g 0 35lb Media Converter MC as CO side Key Features One channel media conversion between 10 100Base TX and 100Base FX Support AUTO Negotiation and AUTO MDIX for 10 100Base TX Port Fiber media allows Multi mode fiber using SC ST VF 45 MT RJ or LC connector Single mode fiber using SC or ST connector WDM single fiber bi direction transceiver Single mode WDM fiber Using SC connector e Builtin 128K bits RAM for data buffer 6 User Manual Managed Meda Converter Chassis System Status LEDs Used with a Managed Chassis Hot swappable when used with a managed chassis Technical Specification LED Per Unit PW FA Power Failure Alarm PerPot 10 00TX LK AT Link Activity FD CL Full duplex Colision 100FX LK AT Link Activity Ethernet Standards IEEE 802 3 10Base T IEEE 802 3u 100Base TX 100Base FX Cable 10Base T2 pair UTP Cat 3 4 5 up to 100m 3281 100Base TX 2 pair UTP Cat 5 up to 100m 328ft 100Base FX 50 or 62 5 125um Multimode fiber optic cable 9 or 10 125u
10. Managed Meda Converter Chassis System Preface The Managed Media Converter Chassis System supports the Media Converter Chassis to monitor the each Media Converter CO or Chassis Manager status and to configure advanced function of the Managed Converter Chassis Through Out band management via Web Browser utility to monitor configure the Managed Media Converter Chassis System This manual describes how to configure all Media Converter CO Chassis Manager and each Managed Converter Chassis which features eight slots of Meida Converters CO or Chassis Manager in one Managed Converter Chassis as well as the Remote side Terminal Media Converter CPE The system allow to have 4 Managed Converter Chassis on one Managed System by using IN OUT Port for stacking all you require to do is simply slide in one Chassis Manager to any of Managed Converter Chassis in order to manage the system To get the most out of this manual you should have an understanding of networking concepts such as bridging IEEE 802 3 10Base T Ethernet IEEE802 3u 100Base TX FX Fast Ethemet and local area networks LANs For more information about these topics please refer to the Appendix 1 User Manual Managed Meda Converter Chassis System Table of Contents Preface 1 Table of Contents 2 Chapter Overview 3 Technical Specifications 3 System Configuration 3 Application and Connector Pinouts 3 Technical Specification 4 Chassis Manager 4 Media Converter MC
11. Manual
12. TO MDIX for 10 100Base TX Port e Fiber media allows Multi mode fiber using SC ST VF 45 MT RJ or LC connector Single mode fiber using SC or ST connector WDM single fiber bi direction transceiver Single mode WDM fiber Using SC connector Atype WDM single fiber bi direction transceiver transmits with 1310nm wavelength and receives with 1550nm wavelength B type WDM single fiber bi direction transceiver transmits with 1550nm wavelength and receives with 1310nm wavelength e Built in 128K bits RAM for data buffer e Builtin CPU with 2M Bytes Flash amp 8M Bytes SDRAM e Status LEDs e Used with a Managed Chassis Hot swappable when used with a managed chassis e System Change Device Name New Password Old Password Version MAC address IP Configuration DHCP IP address Netmask Default Gateway Chassis Hardware Monitor Temperature Supply Voltage Value Fan Status Active MC Uptime e CO MC Status Operation Status Link Status Receive Count Drop Count Collision Count e CO MC Control Forwarding Mode Remote Control Link Fault Pass Through Port Mode Flow Control MDIX Output Rate Input Rate Informing Way for Receiving Off 4 User Manual Managed Meda Converter Chassis System CPE MC Auto Report CPE MC Status Status of power Status of receiving optical power Terminal link status MC status Informing way for optical receiving power off Status of loopback test Notification of link
13. edia Port2 Type Current Model Port Mode 100HD or 100FD Flow Control Disable or Enable Informing Way for Receiving Off Far End Fault Patten or Maintenance Frame lt NOTE gt After configuration set need to press the Apply button to save the setting 377 Loop back Test Chassis gt Chassisst0 3 gt MC 1 8 gt Loopback Test Status Final or Error Result OK or Message for error lt NOTE gt If you wish to retest for Loopback Test again please press the Apply botton for the most update status 3 8 MC Hardware Monitor Chassis gt Chassis 0 3 gt MC 1 8 gt MC HW Monitor 21 User Manual Temperature 45C Supply Voltage 2 5 Volts Supply Voltage 3 3 Volts Supply voltage 12 Volts NOTE gt Under the normal condition suggest the tolerance for all Supply Voltage should not exceed 10 4 Monitor 4 1 Total CO MC Status Monitor gt Chassis 0 3 gt Total CO MC Status This section divide to 3 different Managed Converter Chassis with No on each Chassis unit 22 User Manual This section you can see the MC Status for all Media Converter installed in the Chassis 4 2 Total CPE MC AutoReport Monitor gt Chassis 0 3 gt Total CPE MC AutoReport a Tw AS B Bm zs ver ama BH ADS Aa rx Sc orc EL CAL oc em Les DEL occa oS ee o a This section you can see the
14. m Single mode fiber optic cable Switching Method Store and Forward Forwarding Rate 14 880pps for 10Mbps 148 81 0pps for 100Mbps Power Consumption 3W Max Physical ification Power 0 25A 12VDC Power Supply Operating Temperature 0 C 45 C 32 F 113 F Storage Temperature 10 C 70 C 14 F 158 F Humidity 5 95 non condensing Emission amp Compliance CE Mark Class A FCC Part 15 Class A Dimensions 80mm W x 124mm D x 20mm H 3 15 W x 488 D x 079 H Net Weight 160g 0 35lb 7 UserManual Managed Meda Converter Chassis System Media Converter Terminal as CPE side Key Features One channel media conversion between 10 100Base TX and 100Base FX e Support AUTO Negotiation and AUTO MDIX for 10 100Base TX Port Fiber media allows Multi mode fiber using SC ST VF 45 MT RJ or LC connector Single mode fiber using SC or ST connector WDM single fiber bi direction transceiver Single mode WDM fiber Using SC connector e Built in 128K bits RAM for data buffer eStatus LEDs Wall mountable Extemal Power Adapter 0 25A 9 12VDC Technical Specification LED Per Unt PW FA Power Failure Alarm Per bot 10H00 TX LK AT Link Activity FD CL Ful duplex Collision 100FX LK AT Link Activity Ethemet Standards IEEE 802 3 10Base T IEEE 802 3u 100Base TX 100Base FX Cable 10Base T2 pair UTP Cat 3 4 5 up to 100m 328ft 100Base TX 2 pair UTP Cat 5 up to 10
15. minal link status Link Up or Link Down MC status Normal or Fault Informing way for optical receiving power off Far End Fault Pattem or Maintenance Frame Status of loopback test Normal or Fault Notification of link status for the terminal Support or Not Support Terminal link speed 100M or 10M Duplex for the terminal Full or Half 19 User Manual Managed Meda Converter Chassis System Capability of auto negotiation for the terminal Enable or Disable Number of interface in terminal 1 or More Than 1 lt NOTE gt If you wish to get the most recent remote status please press the Apply button forthe status 3 6 CPE MC Control Chassis gt Chassis t 0 3 gt MC 1 8 gt CPE MC Control MC Options Forwarding Mode Store Forward or Cut Through or Repeater or Auto Change Remote Control Disable or Enable Link Fault Pass Through Disable or Enable Media Port 1 Type Current Model Port Mode Auto or 10HD or 10FD or 100HD er 100FD Flow Control Disable or Enable MDIX Disable or Enable Output Rate Full or 25 or 50 or 75 Input Rate Full or 25 or 50 or 75 20 User Manual Managed Media Converter Chassis System M
16. mp Compliance CE Mark Class A FCC Part 15 Class A Dimensions 440mm W x 235mm D x 44mm H 17 32 W x 9 25 D x 1 73 H Net Weight 3Kg 6 6lbs 10 User Manual Managed Media Converter Chassis System System Configuration Connecting to Power The chassis system is equipped with two power connectors When the chassis is connecting with two powers you can have the redundant function AC power connector DC power connector AC 100V 240V 267A 12VDC Chassis Stacking The Stacking function allows up to four chassis to be interconnected via their Stacking ports This forms a four chassis stack that can then be managed and configured as thought the entire stack were a single chassis manager The chassis stack is then accessed through a single IP address The stacking ports are marked IN and OUT The RJ45 compliant cable must be connected from an IN port on one Switch to an OUT port on the next Switch in the stack The last two Switches at the top and bottom of the stack must also be connected from the IN port on one Switch to the OUT port on the other Switch In this way a loop is made such that all of the Switches in the Switch stack have the IN stacking port connected to another Switch s OUT stacking port NOTE chassis number is configured using the front panel switch Managed Meda Converter Chassis System Web Based Browser Interface The Managed Media Converter Chassis System is accessible using a Web
17. o save the setting 17 User Manual Managed Media Converter Chassis System 3 4 CPE MC AutoReport Chassis gt Chassisst0 3 gt MC 1 8 gt CPE MC AutoReport Status of Loopback test Not Test or Test Option B Support or Not Support lt Note gt If the Option B is support by Terminal side which can inform speed duplex and auto negotiation in terminal our default setting is Support TP port auto negotiation Enable or Disable TP port speed selection 100M or 10M TP port duplex mode selection Full or Half TP port flow control selection Enable or Disable TP port link Link Up or Link Down Fiber port flow control backpressure Enable or Disable Fiber port duplex mode Full or Half Fiber port signal detect On or Off MC power status Normal or Fault MC status Normal or Fault 18 User Manual Managed Meda Converter Chassis System Informing way for optical receiving power off Far End Fault Pattem or Maintenance Frame MC support multi port UTP 1 or More Than 1 Link Fault Pass Through Disable or Enable 3 5 CPE MC Status Chassis gt Chassis 0 3 gt MC 1 8 gt CPEMC Status Status of power Power On or Power Off Status of receiving optical power Normal or Fault Ter
18. status for the terminal Terminal link speed Duplex for the terminal Capability of auto negotiation for the terminal Number of interface in Terminal e CPE MC Control Forwarding Mode Remote Control Link Fault Pass Through Port Mode Flow Control MDIX Output Rate Input Rate Informing Way for Receiving Off Loopback Test MC Hardware Monitor Temperature Supply Voltage SNMP Configuration System Contact System Location Get Community Set Community e Alarm Alarm Configuration Hardware Alarm Configuration Alarm Mail Trap Alarm SNMP Trap TFTP Client for Software Upgrade Telnet SNMP V1 amp V2 Web Browser and TFTP Management Enterprise MIB e Used as with a Managed Chassis e Hot swappable in any Slot when used with a managed chassis e Able to Manage up to 32 CPE Converters Technical ification LED Per Unit PW FA Power Failure Alarm Per bot Console Activity Left LED Full duplex Collision Right LED 10 100TX LK AT Link Activity FD CL Ful duplex Collision 100FX LK AT Link Activity Ethemet Standards IEEE 802 3 10Base T IEEE 802 3u 100Base TX 100Base FX Cable 10Base T2 pair UTP Cat 3 4 5 up to 100m 328ft 5 User Manual Managed Meda Converter Chassis System 100Base TX 2 pair UTP Cat 5 up to 100m 328ft 100Base FX 50 or 62 5 125um Multimode fiber optic cable 9 or 10 125um Single mode fiber optic cable Switching Method Store and Forward Forwarding Rate 14 880pps for
Download Pdf Manuals