Home
User Manual
Contents
1. A IGE D RTNMxxxx D Idxxx D GDxxx iT MIN GY Important Information General Before using your ALGE TIMING device read the complete manual carefully It is part of the device and contains important information about installation safety and its intended use This manual cannot cover all conceivable applications For further information or in case of problems that are mentioned not at all or not sufficiently detailed please contact your ALGE TIMING representative You can find contact details on our homepage www alge timing com Safety Apart from the information of this manual all general safety and accident prevention regulations of the legislator must be taken into account The device must only be used by trained persons The setting up and installation must only be exe cuted according to the manufacturer s data Intended Use The device must only be used for its intended applications Technical modifications and any misuse are prohibited because of the risks involved ALGE TIMING is not liable for damages that are caused by improper use or incorrect operation Power supply The stated voltage on the type plate must correspond to voltage of the power source Check all con nections and plugs before usage Damaged connection wires must be replaced immediately by an authorized electrician The device must only be connected to an electric supply that has been installed by an electrician according to IEC 60364 1 Never touch the mains
2. Subject to changes Page 3 of 12 A IGE D RTNMxxxx D Idxxx D GDxxx 1 In General This manual applies for all D IDxx D RTNMxx and D GDxx LED Matrix display systems Between all of these diplay systems the only differences are at the pixel spacings and the resolution 2 Connections Temperature sensor OPTION Connection for timing device and external power supply 12 VDC OPTION RS232 and RS485 OPTION RS232 for ALGE TIMING timing device OPTION Ethernet Range 90 130VAC or 180 260V 50 60Hz ajust according to country I Always check the switch setting 110 230V at switching power supply open casing before initial operation at a new location USA 110V Europe 230V 3 Configurations All LED fullmatrix displayboard of type D xxx will be configured with the PC Software Dis playStudio Please refer to the separate manual for this DisplayStudio software 3 1 Network connection Together with your D xxx displayboard a Cross Patch network cable is provided This en ables a direct connection between control computer and displayboard In case that the dis playboard is used in a network with hubs and switches you have to use a simple network cable straight instead of the Cross Patch cable 3 2 IP address P addresses enable a logic addressing of devices hosts in IP networks like e g the inter net One host possesses at least one unique IP address An IP address of IP version 4 nor mally appe
3. plug with wet hands Never touch live parts Cleaning Please clean the outside of the device only with a smooth cloth Detergents can cause damage Never submerge in water never open or clean with wet cloth The cleaning must not be carried out by hose or high pressure risk of short circuits or other damage Liability Limitations All technical information data and information for installation and operation correspond to the latest status at time of printing and are made in all conscience considering our past experience and knowl edge Information pictures and description do not entitle to base any claims The manufacturer is not liable for damage due to failure to observe the manual improper use incorrect repairs technical modi fications use of unauthorized spare parts Translations are made in all conscience We assume no liability for translation mistakes even if the translation is carried out by us or on our behalf Disposal If a label is placed on the device showing a crossed out dustbin on wheels See drawing the European directive 2002 96 EG applies for this device Please get informed about the applicable regulations for separate collection of electrical and electronical waste in your country and do not dispose of the old devices as house hold waste Correct disposal of old equipment protects the environment and humans against negative consequences C K Copyright by ALGE TIMING GmbH All rights reserved Any dup
4. red framed box so that the first three lines of figures correspond with those in the upper box Click on Change the formerly red figure should now be black e You have to change the IP addresses as mentioned below so that the displayboard can communicate with the computer ATTENTION You should never use the addresses xxx XXxX XXX 1 Or XXX XXX XXX 255 since these P addresses were formerly used for special network applications We cannot guarantee that these addresses will work properly Modem IF Configuration Ethernet Address 00 06 55 01 11 C2 IF Address 192 168 1 100 Subnet Mask 255 255 255 0 Gateway 192 168 1 253 e After activating the button Change the IP address in the search window of Network Device Toolkit will turn black Now you have an operating network Page 6 of 12 D RTNMXxxxx D Idxxx D GDxxx ALGE IMPORTANT With WindowsXP Sevicepack2 the communication via netwerk must be re leased at the first start of the application Windows Sicherheitswarnung Der Windows Hrewall hat aus Sicherheitsqrimden einige Funktionen dieses Progamms geblockt Soll dieses Programm weiterhin geblockt werden Name NodEm Utility Suite Application Herausgeber Yipee Inc Weiterhin blocken Nicht mela blocken Der Windows Firewall hat die Annahme von Verbindungen aus dem Intemet oder einem anderen Netzwerk fur dieses Programm geblockt Sie konnen die Spermung aufheben wenn Sie das Pr
5. Guest players who were in the field 20 24 Home players who were and who are currently in the field 25 29 Guest players who were and who are currently in the field 30 34 Players of the team exchanging player s who are currently in the game 40 44 Players of the team exchanging player s who were in the game 50 54 Players of the team exchanging player s who were and are in the game hxx Home player name typed from command console xx can be 0 11 tal Guest player name typed from command console xx can be 0 11 IXX Home player number typed from command console xx can be 0 11 XX Guest player number typed from command console xx can be 0 11 Mxx Messages typed from command console xx is message number can be 00 19 Those variables are entered from Scoreboard software or Basketball statistic soft ware Page 9 of 12 A IGE D RTNMxxxx D Idxxx D GDxxx 4 2 1 Loading of start lists This function serves for the usage of the displayboard together with timing devices Before the run starts you can load a start list into the display This will remain stored until a new start list or a new display list will be loaded You can find the tool ExcelToDisplay in the DisplayStudio under tool ExcelToDisplay Excel To Display Software x With open you can load the excel file Player Names With send you can transmit the start list to the _L Klaudia display _ 5 Martina _ Martina Sonja Eathar Ines Nic
6. RTNM P7 7 46 4 6 Data protocol Data protocols are not publizied in the standard manual On request we will provide you with informal protocols in English 7 Adjustment of input voltage The switching power supplies are situated in the casing quantity according to type of display All switching power supplies have to be commutated to the corresponding input voltage 110 230VAC switch Schalter Page 11 of 12 A IGE D RTNMxxxx D Idxxx D GDxxx TIMING Page 12 of 12
7. ars as a series of four figures between 0 and 255 while each will be separated by a dot e g 192 168 0 34 or 127 0 0 1 Every used device within a network must possess an own unique IP address This means that there are at most 2 possibilities 4 3 billion addresses Page 4 of 12 D RTNMxxxx D Idxxx D GDxxx ALGE D xxx displayboards must receive an appropriate IP address for communication with the PC Software DisplayStudio Also the computer at which DisplayStudio is installed must be con figured correctly In order to configure an IP address of a D xxx displayboard in a non configured network a special cofiguration software is installed together with the installation of DisplayStudio At point 3 2 1 you can find a description for adjusting an IP address with the help of Network Device Toolkit 3 2 1 Network Device Toolkit This program serves for basic adjustments like setting the IP address at your displayboard D xxx Below we describe how an IP address of a displayboard can be arranged for its network lf you use a network with more than 2 user these settings should be managed by a system administrator e Connect displayboard D xxx with provided Cross Patch to the computer and switch on both devices e Start PC Software programs ALGE TIMING DisplayStudio Network Device Toolkit EE Display Studio Nodem PING E Nodem Utility Suite Deinstallieren Afterwards click button Search in the
8. d Score HOME in 2 time period Score GUEST in 2 time period Score HOME in 3 time period Score GUEST in 3 time period Variable Description o B00 Score HOME 3 digit clear leading zeros B01 Score GUEST 3 digit clearleadingzeros o B02 Time minutes S B30 B31 B32 B33 B34 B35 Page 8 of 12 NO NO O 00 D RTNMxxxx D Idxxx D GDxxx ALGE B36 Score HOME in 4 time period B37 Score GUEST in 4 time period B38 Sign for ball possession HOME or set HOME volleyball B39 Sign for ball possession GUEST or set GUEST volleyball B41 Number of timeouts HOME team B42 Number of timeouts GUEST team B40 Game Period has value E for extra time period B43 Attacking Time B44 Attacking Time or TimeOut B45 Penalty HOME that expires first when only one penalty is shown format PP mm ss B46 Penalty GUEST that expires first when only one penalty is shown format PP mm ss B47 Misconduct penalty HOME that expires first when only one penalty is shown format MPP mm ss B48 Misconduct penalty GUEST that expires first when only one penalty is shown format MPP mm ss 589 5850 a Far Ho Ho HS Hoz Hos oF Gxx GUEST player name xx is player number from 00 to 99 A U gt lt x lt Player name leaded with player number Depending on xx is 0 4 5 Home players currently in the field 5 9 5 Guest players currently in the field 10 14 Home players who were in the field 15 19
9. isport usage Variable BOO Description Score HOME 3 digit clear leading zeros B01 Score GUEST 3 digit clear leading zeros B02 Time minutes B03 Time seconds B04 Time 1 10 seconds B05 Remaining TimeOut time B06 HOME team name B07 GUEST team name B08 GUEST team name left allignment B09 Number of fouls HOME team B10 Number of fouls GUEST team B11 Last player who committed a foul B12 Number of fouls for that player B13 1 point ratio HOME team B14 2 points ratio HOME team B15 3 points ratio HOME team B16 2 and 3 points ratio HOME team field B17 Number of fouls HOME team B18 1 point ratio GUEST team B19 2 points ratio GUEST team B20 3 points ratio GUEST team B21 2 and 3 points ratio GUEST team field B22 Number of fouls GUEST team B23 Name of the team exchanging player s B24 Penalty1 HOME in format PP mm ss PP player number mm minutes ss seconds B25 Penalty2 HOME in format PP mm ss PP player number mm minutes ss seconds B26 Penalty1 GUEST in format PP mm ss PP player number mm minutes ss seconds B27 Penalty2 GUEST in format PP mm ss PP player number mm minutes ss seconds Misconduct penalty HOME in format MPP mm ss M sign for misconduct PP player number mm minutes ss sekonds Misconduct penalty GUEST in format MPP mm ss M sign for misconduct PP player number mm minutes ss sekonds Score HOME in 1 time period Score GUEST in 1 time perio
10. lication either in full or in part requires the prior written consent of the copyright holder Page 2 of 12 D RTNMxxxx D Idxxx D GDxxx Table of Content TV WAGGA secu ssndcestentee goat aninstnianeteacrencesadentadinsnazansegonysnenantecesduvtsdaesronGaesdeshnenopraneaesseentaiieses 4 2 OONAN CHONG siniraan ie ee ere ee ean oe ee ee eee 4 3 GOOO esn EEE O EEE EE EE 4 3 1 NetWork COnNeC HONcode EAE EAE 4 3 2 Paa O r E E E ee eee ee 4 3 2 1 Network Device Toolkit cccccecccsseccceeeeceeeeceesecceeeeseeeeceeeessueeeseeeeseeeeseseessaeeess 5 A Control with ALGE devices aiicscdncsnngseesacencedectewadelwasdunece snhnde ed astmdnooverenccesextbedsudsscusedacaseauel 7 4 1 Variables for TIMING devices cccccsecccceseccceeseecceneecceueeecaueeeesensesseaeeessueseeseueeesaaeees 7 4 2 Variables for Multisport usage cccccsseecceseeeceeseecceeeeceeeeeeceusesseaeeesseeeeeseeeeessaaess 8 Ascend Loading Ol SLAM NSS eanes aaen E aE a aaia E 10 4 3 ge lalel we de foe F212 e E EE E E E eee 10 5 Technical Data ceccccseseccceececceneeccseeeecceeeecsuneccsaueeesauseesseeesseeesseueeessueeessegeeesseeeessaeeeess 11 O Paila POCO EE E E O 11 Adju stmentoiinpu utvoltage crssseatineeikn e a E i Eiana 11 Copyright by ALGE TIMING GmbH Rotkreuzstrasse 39 A 6890 Lustenau Telefon 43 5577 85966 Fax 43 5577 85966 4 e Mail office alge timing com Internet http Awww alge timing com Version 100930
11. ogramm kennen oder dem Herausgeber trauen Wann sollte die Spenung eines Programms aufgehoben werden If you fail to do so Network Device Toolkit and DisplayStudio cannot communicate with the displayboard This release can also be subsequently set at your computer At System control Safety center Window Firewall you can adjust the necessary changes Please also refer to the manual of your operation system 4 Control with ALGE devices The D RTNM display systems possess an internal storage and an interface which allow tim ing devices as TDC8001 Timy or Multisport console D CKN to change lists and to display running times scores fouls start numbers ranks and names to the start numbers The lay out of the displayboard can be programmed freely with the help of variables The below described variables are added as text to a list and will then show the requested data at the corresponding positions 4 1 Variables for Timing devices Variable Describtion Describtion S O Current time from timing device automatic format hh mm ss th D200 Nation of current bib D201 Club of current bib s000 Name of bib 001 999 sA00 Nationality of bib A00 A99 000 099 B00 B99 100 199 sa00 nn Club of bib a00 a99 000 099 b00 b99 100 199 nn length of field in characters max 10 D000 D194 Byte from data string Page 7 of 12 A IGE D RTNMxxxx D Idxxx D GDxxx Example 4 2 Variables for Mult
12. ole N Lorenz Milos OTPDVS wl co 1 2 J 4 5 E r g g 1 0 T Alex 11 G Ludwig 12 H Bernh 13 A Felis 14 R Arthur 15 Emma 16 bl Christ 4 3 Change of display lists You can switch the active display list by indicating special start numbers In the DisplayStu dio under tools parameter you can find the item serial communication the adjustment for special startnumbers Beginning at this start number you can add or activate up to 32 lists Recommandation List 1 for programming timing List 2 for advertisement List 3 for advertisement etc If you add start number 902 at the TdC the list 2 will be played once afterwards the display will jump back to the list active before 903 is list 3 etc If you would like to activate the list permanently you have to indicate start number 932 Page 10 of 12 D RTNMXxxxx D Idxxx D GDxxx ALGE 5 Technical data Here you can find a list of the most popular technical data of the different models If your displayboard is not listed please contact ALGE TIMING for the technical data in detail i Horizontal Vertical Horizontal oe n o a Length Height Depth f f Pixelpitch Pixelpitch Pixel Pixel mm mm mm mm mm D RTNM P3 16x96 2200 500 3500 500 Additionally we have the following Pixelpitches for customized applications available ae LED Vertical Horizontal D RTNM P1V1 D RTNM P1V2 D
13. program E NodEm Utility Suite Fie Device Management Setup Test View Help ae tbe se SN 2C68 IM24 IP 192 168 4 100 e Ifthe IP address appears in red like in the example above you have to change the address If several P addresses are found several displayboards are connected to the network The displayboards can be distinguished from each other by the figures in front of the IP address This is the internal unique serial number For this click on button call Page 5 of 12 A IGE D RTNMxxxx D Idxxx D GDxxx e Configuration window to set the local IP address for displayboard D xxx opens NodEm Setup 192 168 4 100 X Host IF Configuration Computer Name IBM ROMAN IP address of the computer Host IF Address 192 168 1 114 Net mask only filters suitable addresses In Host Subnet Mask 295 205 295 U the example the first 3 figures of all con nected computers must correspond if the Host Gateway 192 168 1 253 a network is to work 192 168 1 xxx ModE m IF Configuration Ethernet ddress 00 06 55 01 11 L2 IP Address ao Present IP address of displayboard Subnet Mask 2565 255 255 0 Present net mask Gateway 192 168 1 253 Pa Present adjusted gateway Remarks for red framed boxes here the first three lines of figures have to correspond in order to guarantee a communication between computer and display board In the above example the figure 4 would have to be replaced by a 1 in the lower