Home
Installation and Operation Manual
Contents
1. Turn OFF Tone Acknowledgment except for the answer and correct access code BLEEP prompts Hang Up Firmware version number The following commands can only be entered in the LOCAL MODE Normal Operation Default PROGRAMMING e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 9992 NOTE 9993 DC 8 Plus Installation and Operation Manual Radio Network program back up mode The DC 8 Plus is connected to the Silence Monitor III SM III When the Silence Monitor III detects a loss of audio or white noise the DC 8 Plus dials the networks auto coupler and back feeds programming over the phone line The DC 8 Plus also controls a 2x1 switcher which in turn switches from the Satellite feed to the backup phone line feed via the DC 8 Plus When normal Satellite programming is restored the DC 8 Plus waits 60 seconds then hangs up and switches audio back to the Satellite This mode should disallow Relay 1 to be controlled on an initiated dial out Remote broadcast recording RECORD When key 1 is released the double acknowledgment beep is sent K1 closes for 1 2 second No tone is recorded STOP When key 2 is released K2 closes for 1 2 second and then the double acknowledgment beep is sent Note A good number of systems stop the record process if a short period of silence is detected Therefore we suggest that when using this command it is wise to wait two seconds after finishing
2. com voice 360 854 9559 fax 866 783 1742 WEBSITE Visit our web site for product updates and additional information C Broadcast T BROADCAST t oO M Innovative Problen Product Listings Hot New Products AVR onse Welcome to Broadcast Tools sir News amp Reviews Download our Short Form Catalog PROGRAMMING SPECIFICATIONS Send Input Level Auxiliary Input Level Receive Output Levels Logic Relays OC DC 8 Plus Installation and Operation Manual Adjustable Max 24dbu balanced 20 K Q bridging Input to Phone line Adjustable Max 24dbu balanced 20 KQ bridging Input to DTMF detector Adjustable Off to 4 dbu 100 Q balanced output Receive from phone line Microprocessor non volatile memory high performance DTMF transceiver Sealed relays 6 SPDT 2 2PDT Bifurcated Crossbar silver alloy with gold overlay contacts 30 vdc 750 ma Open collector Ground Sink 24 vdc 100 ma NOTE For safety do NOT connect 120VAC circuits to the relays Status Busy Connectors FCC registration Ringer equivalence Power Requirements Size Weight Compatible with CMOS TTL open collector or contact closures Active low Max logic voltage 5 vdc Screw style wire captive terminals Modular RJ 11C W telephone and phone line 1 Modular cable supplied Complies with FCC parts 15 amp 68 Reg BRDUSA 3604
3. era eee eae es 14 bourg nM rr EERTIMBBT 15 Connection Example ou ud ucuuoreE 3 oe x atas nd ae Rn Appendix e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DC 8 Plus Installation and Operation Manual INTRODUCTION Thank you for your purchase of a Broadcast Tools Inc DC 8 Plus Dial up Remote Control We re confident that this product will give you many years of dependable service This manual is intended to give you all the information needed to install and operate the unit SAFETY INFORMATION Only qualified personnel should install Broadcast Tools products Incorrect or inappropriate use and or installation could result in a hazardous condition WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your distributor from whom you purchased this equipment If you would like more information about Broadcast Tools products you may reach us at Broadcast Tools Inc 131 State Street Sedro Woolley WA 98284 USA Voice 360 854 9559 Fax 866 783 1742 Internet Home Page www broadcasttools com E mail support broadcasttools com THANK YOU FOR CHOOSING BROADCAST TOOLS BRAND PRODUCTS Assembled in the USA by American Workers e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 CAUTION Broadcast Tools Products as with any electronic device can fail without warning Do not use this
4. product in applications where a life threatening condition could result due to failure amp NOTE This manual should be read thoroughly before installation and operation WEBSITE Visit our web site for product updates and additional information C Broadcast T BROADCAST too M Product Listings gt Hi Innovative Problen Welcome to Broadcast Tools ls Inc ETT specialize affordable and inne led controllers and intercom systems Founded in 1987 and ied in Sedro W Washington our products have a strong for durability and reliability and can be o top distributors across the United States worldwide INTRODUCTION DC 8 Plus Installation and Operation Manual FCC NOTICE TO THE USERS 1 UPON REQUEST ONLY you must provide the following data to your telephone utility company 2 a Notice of intention to install or permanently remove an FCC Part 68 registered device syste and the FCC Registration Number SEE page 14 of this manual b The Ringer Equivalence Number SEE page 14 of this manual Note that if several devices are connected to the same line the REN s must not add up to more than 4 0 A or B This REN figure is important to your telephone utility company c The USOC jack type to be provided by the telephone utility company e NOTE Typically this will be RJ 11C W for single lines Items above flagged 3 This device may not b
5. the recording before pressing this key eliminating the tone being recorded PLAY When key 3 is released the double acknowledgment beep is sent Send phone audio is turned on and K3 is closed for 1 2 second The unit stays here until 1 minute has elapsed without a key entry or any other key has been pressed except Keys 1 2 which turns OFF the play function Pressing Keys 4 6 during this function closes their respective relays for 1 2 second REWIND Key 4 Same as PLAY function except K4 FAST FORWARD Key 6 Same as PLAY function except K6 9994 9995 Future 9096xxxxxxxx Master Access code Default 9999 Software Version NOTE Be sure to terminate all commands on this page with a star PROGRAMMING e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DC 8 Plus Installation and Operation Manual To use the DC 8 Plus as a DTMF tone decoder for tones 1 through 8 follow the listed steps below Jumper Status inputs one and two to the DGND terminals Connect the audio output of the device to be monitored to the AUX input terminals Connection to the phone line and telephone are NOT required for this option Put the OPERATE LOCAL switch into the LOCAL position IN Adjust the rear panel AUX IN level control to accommodate proper tone detection NOTE Overloading the send or aux audio input may cause erratic DTMF operation e mail support broadcasttools
6. the relay is open Follow the format provided with the DC 8 Plus COMMAND GRID NOTE During a power outage when power is returned latched relays will return to their pre power outage position POLLING THE STATUS INPUTS In order to check the status of any STATUS PAGER ALERT input simply press the star key followed by the TWO DIGIT status number and then the star key In the event the status input condition is in a gt 2 5 vdc high condition a high tone will be heard In a low ground status condition a low tone will be heard After each command a double bleep will acknowledge completion of the command If an error tone three warbles is received re enter the command Follow the format provided with the DC 8 Plus COMMAND GRID e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 WEBSITE Visit our web site for product updates and additional information too M Innovative Problen Welcome to Broadcast Tools Bro ir OPERATION DC 8 Plus Installation and Operation Manual BUSY INPUT The busy input allows a user to remotely disable the DC 8 Plus from answering a call By asserting this input low no calls will be answered PAGER ALERT The DC 8 Plus includes the ability to call up to THREE outside telephone pager numbers in the event any or all status inputs go LOW for 2 seconds or longer As shown in the DC 8 Plus Command Grid the Pager Aler
7. time the ring signal is detected NOTE The call will be answered after the user programmed number of rings At this time the HOOK LED will light and the rear panel HOOK open collector will go low NOTE The DC 8 Plus will hang up if the following conditions occur 1 If more than minute has elapsed before a correct access code is entered 2 If no commands are detected for 1 minute CPC defeated 3 If the calling party hangs up 4 If command 99 star is entered CONTROLLING OR POLLING THE RELAYS Relays may be selected by entering the appropriate relay number This command will produce a relay action for as long as the key is held If you prefer a latching contact closure enter the 7 pound key the relay number followed by the star key Performing this function will latch the relay into the on mode To unlatch a relay contact enter the star key relay number and the star key Performing this function will return the appropriate relay to an off or unlatched mode If you have selected the interlock mode only one relay may be latched at any one time After each command a double bleep will be heard acknowledging completion of the command If an error tone three warbles is received re enter the command In order to check the status of any relay simply press the pound key followed by the TWO DIGIT relay number and the star key A high tone will be heard if the relay is closed and a low tone if
8. 2 OT T 0 4B 16 to 18 Vac 600 ma 120 Vac wall transformer Supplied 240 Vac 50 60 hz optional 19 X 1 75 X 4 50 WHD 3 0 Ib SPECIFICATIONS e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 14 DC 8 Plus Installation and Operation Manual LIMITED WARRANTY The term Buyer as used in this document refers to and includes both but only a any person or entity who acquires such an item for the purpose of resale to others i e a dealer or distributor of an item and b the first person or entity who acquires such an item for such person s or entity s own use Broadcast Tools warrants to each Buyer of any item manufactured by Broadcast Tools that the item will be free from defects in materi als and workmanship at the time it is shipped by Broadcast Tools if the item is properly installed used and maintained EXCLUSIVE REMEDIES If Broadcast Tools is notified in writing of a failure of any item manufactured by Broadcast Tools to conform to the foregoing Limited Warranty within one 1 year following the date of the Buyer s acquisition of the item and if the item is returned to Broadcast Tools in accordance with Broadcast Tools instructions for confirmation by inspection of the defect which at Broadcast Tools election may include without limitation a requirement that the Buyer first obtain a Return Authorization number from Broadcast Tools that the Buyer furnish proof of purchase in the form o
9. 998 BROADCAST Mrs NI Installation and Operation Manual rs C 2 m 2 em Ou co z e P3 o DC 8 Plus Dial Up Remote Control Firmware version 2 12 and above Manual Update 07 12 2011 Due to the dynamic nature of product design the information contained in this document is subject to change without notice Broadcast Tools Inc assumes no responsibility for errors and or omissions contained in this document Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com for important product update information DC 8 Plus Installation and Operation Manual Table of Contents Section Title Page inge ieu CREER D 3 Safety Information m arch eere at eq a ee e RE dod ee wa eee 3 Who 10 Contact Tor Helps usse exe qp dm REGE S doi 3 FCG NOTICE cct 4 General DeSOFIDUDE ss d acu ibas aac 9a nd e mop eri RUE HI Ka E 5 Additional Features oy shine sicud ea eons oS RH HIC eh a abel 5 Typical Applicatlolis 2395293 seated cease E GS EEE AREE dort 5 Installing the DC 8 Plus nonna nannaa naa 6 Programming and Operation s ascece doe e nanne 7 Specifications esne s bra eae een ducto a
10. ADVISED OF THE POSSIBILITY OF SUCH DAMAGES HAVE ANY LIABILITY FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL EXEMPLARY OR PUNITIVE DAMAGES THIS LIMITATION OF LIABILITY APPLIES WHETHER A CLAIM IS ONE ALLEGING BREACH OF A CONTRACT OR WARRANTY NEGLIGENCE OR OTHER TORT FOR THE VIOLATION OF ANY STATUTORY DUTY THE FAILURE OF ANY LIMITED OR EXCLUSIVE REMEDY TO ACHIEVE ITS ESSENTIAL PURPOSE OR ANY OTHER CLAIM OF ANY NATURE BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THIS LIMITATION MAY NOT APPLY TO YOU Broadcast Tools Inc 131 State Street Sedro Woolley WA 98284 USA 360 854 9559 voice 866 783 1742 fax support broadcasttools com e mail www broadcasttools com website LIMITED WARRANTY e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 E A N I L TOOLS Sentinel TOOLS TOOLS Sentinel Broadcast Tools Connection suggestion when using listed equipment with DSL Telco Phone Lines APPENDIX RJ11 Modular Cable Ethernet DSL MODEM RJ11 Modular Cable DSL DC 8A DC 8 Plus Filter Site Sentinel 8 w Voice Required STA III STI II VAD 2 for proper VAD 2 Plus WVRC 4 operation WVRC 8 131 State Street Sedro Woolley WA 98284 1503 360 854 9559 Fax 866 783 1742 Visit us online at www broadcasttools com Modification Date 07 12 11 Copyright 1989 2011 by Broadcast Tools In
11. automation systems auxiliary control of broadcast transmitters STL s RPU s IFB monitoring intrusion alarm EAS con trol of remote cameras etc e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 WEBSITE Visit our web site for product updates and additional information C Broadcast T BROADCAST too BY Innovative Problen Welcome to Broadcast Tools ade coupled controllers and intercom systems Founded in 1987 and ied in Sedro W ashington our products have a strong for durability and reliability and can be o distributors actoss the United States worldwide DESCRIPTION DC 8 Plus Installation and Operation Manual INSTALLING THE DC 8 PLUS d Please examine your DC 8 Plus carefully for any damage that may have been sus CAUTION tained during shipping If any is noted please notify the shipper immediately and retain the packaging for inspection by the shipper The package should contain the DC 8 Plus 16 5 Vac 600 ma wall power transformer and this manual and modu lar cable For safety do NOT connect 120VAC cir cuits to the RELAYS Before permanently installing the DC 8 Plus we recommend that you connect the unit to the wall transformer telephone line and telephone set and become familiar with the operation of the unit Please refer to the programming and operation sec tion of this manual If the DC 8 Plus is to share the phone line wit
12. c All Rights Reserved
13. e used on telco operated coin phone lines or party lines and with are noted in this privately owned coin phones which are subject to local State regulatory policies manual and on the and possible additional State special requirements equipment s FCC Compliance label 4 The telephone utility company has the right to make changes to their network which may affect the operation of your equipment provided you are given adequate advance written notice to permit correct operation 5 In case of operational problems disconnect your unit by removing the modular plug from the telco jack If your regular phone or other device or system still works properly your DC 8 Plus has a problem and must remain disconnected and officially serviced or returned for repairs If upon the above disconnection your reg ular service still has problems notify your telephone utility company that they may have a problem Request prompt service at no cost to you the user If a problem is found in premises wiring not telco installed you are subject to a service charge If a fault is in telco installed wiring you may not be subject to a service charge 6 Unless otherwise noted in the User s Manual e g fuses etc user may not under any circumstances in or out of warranty attempt any service adjustments or repairs on this unit NO USER SERVICEABLE PARTS It must be returned to Broadcast Tools Inc for all such work Broadcast Tools Inc address and phone in
14. ection from the wall transformer is made on the far right hand side of the unit labeled P1 Connections on the DC 8 Plus are via screw style wire captive terminals located at the rear of the unit Connections to the screw style wire captive terminal should be made using 20 AWG or smaller solid or stranded wire Strip off approximately 7 16 insulation from the connection end of the wire insert the bare wire end into the opening of the desired terminal and tight en the locking screw with a small screw driver The relays are denoted as K1 through K8 K1 and K2 are 2PDT relays while K3 through K8 are SPDT JP1 is provided to tie K1 and K2 together The normally open contact is noted as NO The normally closed contact is labeled NC and the wiper common is denoted as CM This convention holds true for all eight relays The three open collector outputs ground sink are rated at 24 vdc 60 ma and are diode protected The collectors are available at each labeled terminal while the emitters are tied to DGND Visit our web site for product updates and additional information Innovative Problen Welcome to Broadcast Tools Bro ir NOTE For safety do NOT connect 120VAC circuits to the RELAYS e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 6 DC 8 Plus Installation and Operation Manual Each STATUS PAGER ALERT and BUSY input is provided with two terminals a ground terminal lab
15. eled DGND and input terminal labeled IN BUSY These terminals may be connected to any pair of switch contacts such as external relays switches open collector circuits or 5 volt logic signals All inputs have the same common This common is not connected to the power main ground since the AC wall transformer is isolated however the input common is internally connected to the circuit ground and the aluminum enclosure of the DC 8 Plus via a parallel 01 uf cap and 10 ohm resistor A chassis ground screw is pro vided at the rear far right side of the chassis Audio connections on the DC 8 Plus are labeled Out Out In In Aux Aux DL In and DL Out Shields may be tied to the EGND terminal The audio input is labeled TEL and TEL and is active balanced and accepts levels from 10 to 24dbu The send level may be adjusted from the front panel while this input may be turned on and off via touchtone commands The balanced output terminals are always active and labeled OUT and OUT The front panel level control has a range of 4 dbu to OFF The balanced Auxiliary input is labeled AUX and AUX and feeds the DTMF decoder directly and may be adjusted by the AUX control on the rear panel The telephone hybrid null control R23 is adjusted on the rear panel The terminals labeled DL IN and DL OUT are for the user supplied delay unit NOTE Overloading the send or aux audio inputs may cause er
16. f an invoice and or receipt and that the Buyer prepay all freight charges associated with any return of the item to Broadcast Tools using such freight service as Broadcast Tools reasonably may specify Broadcast Tools will repair or replace the defective item or will refund the purchase price paid by the Buyer for the item Broadcast Tools shall have the exclusive right to choose between these alternative remedies NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW BROADCAST TOOLS AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL ITY OR FITNESS FOR A PARTICULAR PURPOSE AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF ALL OTHER REMEDIES THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE JURISDICTION TO STATE JURISDICTION NO LIABILITY FOR CONSEQUENTIAL DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NEITHER BROADCAST TOOLS NOR ANY OF ITS SUPPLIERS SHALL HAVE ANY LIABILITY FOR ANY SPECIAL INCIDENTAL INDIRECT CONSEQUENTIAL OR PUNITIVE DAMAGES WHATSO EVER INCLUDING WITHOUT LIMITATION ANY DAMAGES FOR LOST PROFITS BUSINESS INTERRUPTION LOSS OF DATA OR INFORMATION COST OF CAPITAL CLAIMS OF CUSTOMERS OR ANY OTHER PECUNIARY LOSS ARISING OUT OF THE USE OF OR THE INABILITY TO USE ANY ITEM SUPPLIED BY BROADCAST TOOLS EVEN IF BROADCAST TOOLS HAS BEEN
17. formation is listed on page 3 of this manual 7 Special FCC rules apply to equipment connected behind a PBX or KTS FCC NOTICE e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DC 8 Plus Installation and Operation Manual GENERAL DESCRIPTION The DC 8 Plus Dial up Remote Control allows the user to control and monitor exter nal devices from any touch tone telephone When called the DC 8 Plus will answer the phone line after a user programmable number of rings up to 20 accept an access code none to eight digits and if valid allow the control of six SPDT two 2PDT relays and the monitoring of eight logic level status inputs The DC 8 Plus is equipped with an adjustable audio hybrid allowing the user to send and or receive external audio while controlling the unit additionally the unit is equipped with an auxiliary audio input and a mute circuit to add an optional delay unit for the removal of DTMF tones The pager alerts function allows the activation of up to three digi tal pagers by any or all of the status inputs allowing the display of a user s defined telephone number and which status input triggered the alarm All programming is performed with a standard touch tone telephone All functions may be programmed remotely except the recall of factory defaults and setting of the access code ADDITIONAL FEATURES e High Performance DTMF transceiver Single rack chassis e CPC control the unit hangs up
18. h a modem the purchase of a Voice Data switch may be in order The modem should be connected to the modem port while the DC 8 Plus should attach to the voice or TAD port These units are under 60 00 at Office Max Depot NOTE nstallation of the DC 8 Plus in high RF environments should be performed with care Shielded cable is suggested for all connections Shields and station ground should be tied to the CHASSIS GROUND screw located on the far right side of the DC 8 Plus as viewed from the rear It is recommended that all cables connected to the DC 8 Plus be looped through ferrite cores to suppress RF Surge protection with RF filtering such as the Tripp Lite ISOBAR or equivalent is also suggested for the power transformer while the Tripp Lite DTEL 2 is very effective for the tele phone line The purchase of an inexpensive uninterruptible power sup ply UPS will provide back up in case of power outages The connection of the DC 8 Plus to a standard telephone line or cellular telephone with the appropriate interface is through the RJ 11 jack located at the far left side of the unit as viewed from the rear This jack is labeled Line and should be con WEBSITE nected to the incoming phone line The recessed second RJ 11 jack labeled Phone is for the connection of a touch tone telephone used to program or operate the DC 8 Plus when in the LOCAL mode The DC 8 Plus is supplied with a 16 to 18 volt 600 ma AC wall style transformer conn
19. ratic DTMF operation PROGRAMMING AND OPERATION The Broadcast Tools DC 8 Plus may be operated and programmed either remotely via telephone or while the OPERATE LOCAL switch is depressed Either way all programming and operation is identical The DC 8 Plus Command Grid and Programming Commands may be found on pages 9 10 and 12 of this manual illus trating the programming and operational functions of the DC 8 Plus Let s take a brief run through of the operation of the DC 8 Plus Using a touch tone telephone dial into the telephone number attached to the DC 8 Plus After 3 rings the DC 8 Plus will answer the line and reply with a BLEEP Access to the DC 8 Plus status monitoring functions are possible after the access code has been entered Default access code 1234 If the correct access code has been entered the DC 8 Plus will reply with a DOUBLE BLEEP To control and monitor to DC 8 Plus the control must be entered Default access code NOTE 7he MONITORING ACCESS CODE is entered as follows STAR xxxxxxxx the factory default is 1234 OPERATION e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DC 8 Plus Installation and Operation Manual NOTE THE MASTER MONITORING and CONTROL ACCESS CODE is entered as follows STAR STAR xxxxxxxx The factory default is NOTE When the DC 8 Plus receives a call the red RING LED will light and the rear panel RING open collector will go low each
20. t function can be activated or deactivated by entering 951 star turns on function or 950 star turns off function The user may configure any or all of the eight status inputs to trigger a pager alert by inserting the desired status input numbers in program 954 i e 9541 star Status input one being asserted low will cause an alert In order to program the first call out telephone number enter 961 followed by the FIRST telephone number to a digital pager or other service Enter 962 followed by the SECOND telephone number to a digital pager or other service Enter 963 followed by the THIRD telephone number to a digital pager or other service Not all of the pager need be entered In the event you would like the call back number to be displayed on a digital pager enter 97 followed by the return call back number that will dis play on the pager The DC 8 Plus will place as the FIRST digit the FIRST STATUS PAGER ALERT input that caused the ALERT To provide added reliability the DC 8 Plus dials the pager number twice If your Telephone Company provides CALLER ID ANI this may be a simple way to replace the pager when using the pager alert NOTE Any programming EXCEPT THE ACCESS CODES and DEFAULT SETTINGS can be performed either in LOCAL mode OPERATE LOCAL button depressed or when connected via telephone Please remember to DISENGAGE the front panel OPERATE LOCAL switch when you are finished programming the DC 8 Pl
21. ts NOTE Can only be entered in the LOCAL MODE 951 Turns ON PAGER ALERT function Dials out twice for each pager PROGRAMMING e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 950 952 953 954x x 961x x 962x x 963x x 97x x NOTE 980 981 99 9999 NOTE 9991 DC 8 Plus Installation and Operation Manual Turns OFF PAGER ALERT function Default Turns OFF CPC Reverts back to a 30 second time out on hang up if no activity is detected Turns ON CPC function The DC 8 PLUS hangs up when the caller hangs up Default Pager Alert Status input configuration Enter the status input number s to trigger the alert i e 9541 3 turns on inputs 1 and 3 while 9541 turns on input 1 only The pound sign is used to separate more than one input Telephone number ONE to dial Up to 20 digits 7 1 second pause Default NO number Example 96112069384433 Telephone number TWO to dial Up to 20 digits 7 1 second pause Default NO number Example 96212069384433 Telephone number THREE to dial Up to 20 digits 1 second pause Default NO number Example 96312069384433 Telephone number to be displayed on a digital pager Up to 25 digits Default NO number Example 9712069974343 The first digit in the pager display will be the first status input causing the page alert Turn ON Tone Acknowledgment Default
22. us NOTE f the DC 8 Plus is left in LOCAL mode the DC 8 Plus will not answer incoming calls To hang up and return to the stand by mode either hang up or enter 99 followed by the star key DC 8 Plus COMMAND GRID This manual has provided many programming and operational functions of the Broadcast Tools DC 8 Plus Dial Up Remote Control By using the DC 8 Plus Command Grid additional programming and operation functions are available to customize the DC 8 Plus to fit many needs We hope that like many other users of Broadcast Tools products you too will encounter many years of reliable and versatile use OPERATION e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DC 8 Plus Installation and Operation Manual Latch Turn Send Audio Li 9 TT 09 09 d EE NN 04 O4 Lo O a Clear Error or Start Over PROGRAMMING COMMANDS 901 Auto Answer on first ring NO access code Audio ON Auto coupler mode 900 Mode 901 off Default 911 Turns relay INTERLOCK mode ON ONE latched relay ON at a time 910 Turns relay INTERLOCK mode OFF Default 92xx Number of rings to answer 00 Never Answer Default 3 rings Maximum of 20 93xxxxxxxx Program Access code Access code may be 0 to 8 digits followed by an asterisk NOTE Can only be changed in LOCAL MODE 941234 Resets all configuration information to factory defaul
23. when the caller hangs up may be defeated e User programmable tone acknowledgment defeat May be configured for stand alone DTMF tone decoding e On power loss and restoration all relays retain their prior state Each relay may be configured to close for as long as the associated key is pressed with rising or falling edge latching and interlocking mode Screw style wire captive terminals for easy connection Easily distinguishable tones indicate the high low or open closed status of the eight status inputs and relays Each status input and relay may be indi vidually polled by the user Front panel Indicator LED s display DTMF tone detec tion Hook line connected status ring signal and power Front panel OPER ATE LOCAL switch with LED Indicator Open collector outputs for remote Ring valid DTMF tone and Hook line connected tally Modular connectors for the tele phone line and touch tone telephone Front panel send and receive audio level con trols e Rear panel hybrid null control e Rear panel auxiliary audio level control e Busy input allowing the user to externally disable the DC 8 Plus from answering the telephone line TYPICAL APPLICATIONS The DC 8 Plus may be used in applications where remote control and logic moni toring is required These applications may be remote recorded on a digital hard disk system detection of DTMF tones from syndicated programs control of Satellite receiver controllers audio switchers routers