Home
sestos d1s
Contents
1. CU50 PT100 e Character TSEN 0 1800 E 50 150 200 600 Contact output D1S 2R AC 250V 3A Resistive load NO NC Alarm 1 AC250V 3A Resistive load NO NC 12V Alarm 1 AC250V 3A Resistive load NO NC Mechanical 10 000 000 operations min Electrical 100 000 operations min Sampling period 0 58 e SSR DIS VR Life expectancy Indication accuracy 0 2 FS_ 0 1 C under 1000 C 1 C over 1000 C e Data storage 10 years Temperature compensating 0 50 C e Cutout size 45X45 mm Mounting Method Flush mounting and screw terminals Weight Approx 140 e Ambient temperature Operating 10 55 C with no icing or condensation Storage 25 65 C with no icing or condensation e Ambient humidity 35 85 RH E Nomenclature SESTOS TEMPERATURE OUT Output AL1 Alarm 1 AL2 Alarm 2 RUN Manual SET Setting key Move Auto adjustment y Down key A Up key PV Present value SV Set value Setting and function description SET Function HIAL LoAL dHAL dLAL dF CtrL M50 P t Ctl Sn dIP dIL dIH oP1 oPL oPH ALP CF Addr Baud dl run Loc EPI EP2 EP3 EP4 EPS EP6 EP7 Ep8 Description Absolute value upper limit Absolute value lower limit Upper limit deviation Lower limit deviation Hysteresis Control output Integral Differential Hysteresis time Control period Input sensor Decimal point position in
2. abandon Auto adjustment 4 If successful the first Auto adjustment can not use AT key for Auto adjustment again It need change function setting Ctrl to 2 to operated again 5 Auto adjustment needs from few second to few hour Suggestions 1 Ifuse SSR or SCR for control part setting control period prefer 4 second or shorter 2 Ifuse relay for control part setting control period prefer 20 second or longer for extend the relay life E Dimensions with Flush Mounting Adapter Dimensions Flush Mounting Adapter Panel Cutouts TT Min 60 O ee l 3 A ji e Min 63 y 45 3 O 4 49 45th Sel 8 e 74 89 XAll units are in millimeters unless otherwise indicated Flush mounting adapter YX Y 1 Provided E Terminal Arrangement D1S VR WE Precautions Separate the input signal cables from the power line e Short connecting wire from the sensor to the product is the best if not please using shield cable e Use and store the product within the ratings specified for temperature and humidity Specifications and design subject to modifications without notice SESTOS H K ELECTRONICS CO http www sestos hk com E mail sestos sestos hk com MN DIS EN
3. SESTOS Digital Temperature Controller E Features DIN 48X48mm Temperature Controller Support multi sensor input K S Wre T E J B N CU5S0 PT100 e Wide control range 50 1300 C K sensor Indication and control accuracy 0 1 C high measurement accuracy 0 2 FS e PID and ON OFF control mode Output and alarm format can be set by user Built in digital filter reduce interfere e Self calibration technology keep stabilization e 0 39 height LED prevent dazzle highly visible display e Switching power supply and low consumption Thank you very much for selecting SESTOS products Please read and understand this MANUAL before using this unit W Safety Precautions This product must be mounted on the panel avoid electric shock When the power is turned on is not connecting the terminal avoid electric shock e Ensure the product within the specification e Never disassemble repair or modify the product if needed please contact agent or us e Do not use the product in locations subject to gases dust vibration corrosive direct sunlight water and oil strong EMI Specification Power and input Voltage Ordering The power supply and input circuit are isolated AC 100 240V 10 50 60Hz lt S5VA AC DC 12 24V 10 lt 4VA PV 4 digital 9 9mm height high light red LED SV 4 digital 8 0mm height high light green LED Unit C Range Oo Kk s W _ T E E 50 1700 mesu 2000 350 0 1000
4. put lower limit display input upper limit display Sensor calibration Output method Output lower limit Output upper limit Alarm function System function Input digital filter Run mode Range 1999 9999 1999 9999 0 9999 0 9999 0 200 0 C 0 ON OFF 3 PID 2 Auto adjustment 0 9999 Remarks 0 cancel Factory setting 9999 1999 9999 9999 0 3 ee ee ee ee ee ei es ee ie i ee 1999 9999 1999 9999 199 199 0 Time duty 1 digital 1 digital 0 1 C 2 ALI together with OUT 0 31 2 Heater 3 Cooler 0 20 0 Maunal 1 Automatic 2 inhibit manual PV PV SC See T1 Filter effect Alarm function table T1 Upper limit output AL1 Dee Upper limit alarm A12 Lower limit output AL er Lower limit alarm Al2 Upper limit deviation output ALI a a Upper limit deviation output A12 Lower limit deviation output ALI C Lower limit deviation output A12 B Note Can set alarm in combination format choice the requirement functions and sum of the value setting in ALP Operation Procedures 1 Press SET key 2 second into the function mode after return to the operation mode If no any change after 10 second automatic return 2 For temperature setting press the UP or Down key change the value after 10 second operate the new setting 3 First operate the Auto adjustment press AT key 2 second SV display blink AT finally into PID control mode Press the AT key 2 second to
Download Pdf Manuals
Related Search
Related Contents
PREVAIL - Lexmark In Win Z670 computer case S`enraciner, explorer ses cieux et réaliser son rêve DELL PowerEdge T110 II Copyright © All rights reserved.
Failed to retrieve file